Interindividual and intraindividual variation in pulse wave velocity measurements in a male population.

Abstract:

OBJECTIVE:Pulse wave velocity (PWV) is a measure of arterial stiffness and a marker for cardiovascular disease. Although commonly used, there are only a few reports investigating the intersession and intrasession variability in PWV measurements, the determination of which is important in a mixed population when using PWV as a clinical marker. Therefore, the aim of this study was to investigate the variability in PWV measurements and factors that may influence PWV variability. METHODS:A male population (n=8, age 30.9 ± 9.0 years; BMI 25.1 ± 4.0 kg/m(2)) underwent measurements of PWV and blood pressure several times in a single study visit and during six study visits over a 4-6-week period. During these study visits, experiments were performed at rest and following acute exercise and feeding. RESULTS:Intersession coefficients of variation (CVs) were 5.3 and 4.5% for radial-carotid (R-C) and carotid-femoral (C-F) PWVs, respectively, whereas intrasession CVs were 9.3 and 6.9% for R-C and C-F PWVs, respectively. Good reproducibility in PWV measurements was demonstrated by individual responses in the data; two of eight participants had significant differences in C-F PWV over time (P=0.05). There were significant increases in systolic blood pressure following acute exercise (P<0.0001) and feeding (P=0.05), but there were no consistent changes in PWV measurements. CONCLUSION:These data demonstrate the reproducibility of PWV and that PWV measurements are not acutely influenced by the metabolic state. This has implications for the use of PWV in human intervention trials where a mixed population is being investigated.

journal_name

Blood Press Monit

authors

Tripkovic L,Hart KH,Frost GS,Lodge JK

doi

10.1097/MBP.0000000000000052

subject

Has Abstract

pub_date

2014-08-01 00:00:00

pages

233-41

issue

4

eissn

1359-5237

issn

1473-5725

journal_volume

19

pub_type

临床试验,杂志文章
  • Circadian variation of blood pressure and the assessment of antihypertensive therapy.

    abstract::The inherent variability of activity and the awake-sleep cycle creates changes in hemodynamics that may influence the outcome of a variety of cardiovascular disorders. Recently, data suggest that increased variability of blood pressure may promote excessive hypertensive target organ disease. Several epidemiologic stud...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: White WB

    更新日期:1999-01-01 00:00:00

  • The effect of crossing legs on blood pressure: a randomized single-blind cross-over study.

    abstract:BACKGROUND:Although there is a theoretical basis for crossing legs to increase blood pressure, there are no published data addressing this question. As a result guidelines for measurement of blood pressure are not consistent in recommending that patients legs should not be crossed during measurement. OBJECTIVE:To dete...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Peters GL,Binder SK,Campbell NR

    更新日期:1999-04-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Brachial or wrist blood pressure in obese patients: which is the best?

    abstract:OBJECTIVE:Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS:We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mann...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3282fd16e3

    authors: de Senarclens O,Feihl F,Giusti V,Engelberger RP,Rodieux F,Gomez P,Liaudet L,Waeber B

    更新日期:2008-06-01 00:00:00

  • A novel predictor of radial spasm: arterial stiffness.

    abstract:OBJECTIVE:In this study, we aimed to assess the relationship between radial artery spasm (RAS) and arterial stiffness (AS) measured by the oscillometric method. MATERIALS AND METHODS:A total of 123 consecutive patients scheduled for elective coronary angiography in a single default radial center were enrolled for the ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000340

    authors: Omaygenc MO,Karaca IO,Ibisoglu E,Günes HM,Kizilirmak F,Cakal B,Guler E,Barutcu I,Boztosun B

    更新日期:2018-10-01 00:00:00

  • High-intensity handgrip training lowers blood pressure and increases heart rate complexity among postmenopausal women: a pilot study.

    abstract:OBJECTIVE:Handgrip exercise is an emerging strategy for resting blood pressure (BP) reduction requiring minimal time and exercise effort. However, the research literature is currently limited to handgrip protocol designs predominantly prescribing sustained grip contractions, with little assessment of alternative option...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000313

    authors: Bentley DC,Nguyen CHP,Thomas SG

    更新日期:2018-04-01 00:00:00

  • The effect of Ramadan fasting on ambulatory blood pressure in treated hypertensive patients using diuretics.

    abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000451

    authors: Aslan S,Riza Demir A,Kahraman S,Memiç K,Avci Y,Gürbak İ,Karabulut E,Ertürk M

    更新日期:2020-08-01 00:00:00

  • Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT.

    abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200306000-00006

    authors: El Assaad MA,Topouchian JA,Asmar RG

    更新日期:2003-06-01 00:00:00

  • Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS:Systolic and diastolic b...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000261

    authors: Kang YY,Chen Q,Liu CY,Li Y,Wang JG

    更新日期:2017-08-01 00:00:00

  • Cardiovascular triggers and morning events.

    abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Chasen C,Muller JE

    更新日期:1998-02-01 00:00:00

  • Accuracy of the Microlife large-extra large-sized cuff (32-52 cm) coupled to an automatic oscillometric device.

    abstract::To determine the accuracy of the large-extra large-sized (L-XL) cuff (32-52 cm) coupled to a Microlife WatchBP Office ABI blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The L-XL cuff tested in this study is designed to provide...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328344c73c

    authors: Masiero S,Saladini F,Benetti E,Palatini P

    更新日期:2011-04-01 00:00:00

  • 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?

    abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200110000-00005

    authors: Enström IE,Pennert KM

    更新日期:2001-10-01 00:00:00

  • Identification of subjects with white-coat hypertension and persistently normal ambulatory blood pressure.

    abstract::OBJECTIVE: To assess the spontaneous changes in clinic blood pressure, ambulatory blood pressure (ABP) and left ventricular structure in untreated subjects with white-coat hypertension (WCH). DESIGN: A prospective observational study. PATIENTS AND METHODS: In 83 untreated subjects with WCH, 24 h non-invasive ABP monit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Verdecchia P,Schillaci G,Borgioni C,Ciucci A,Gattobigio R,Sacchi N,Guerrieri M,Comparato E,Porcellati C

    更新日期:1996-06-01 00:00:00

  • Morning hypertension in chronic kidney disease is sustained type, but not surge type.

    abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32835026c6

    authors: Mizuno M,Fukuda M,Miura T,Wakamatsu T,Naito T,Sato R,Togawa H,Sasakawa Y,Tomonari T,Ono M,Kato Y,Ichikawa T,Shirasawa Y,Ito A,Yoshida A,Kimura G

    更新日期:2012-02-01 00:00:00

  • Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

    abstract::Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary cont...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Burnier M

    更新日期:2000-01-01 00:00:00

  • Automated office blood pressure - being alone and not location is what matters most.

    abstract:OBJECTIVE:Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impract...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000133

    authors: Armstrong D,Matangi M,Brouillard D,Myers MG

    更新日期:2015-08-01 00:00:00

  • Ambulatory blood pressure monitoring of chronically dialyzed pediatric patients.

    abstract:BACKGROUND:Background Ambulatory blood pressure monitoring (ABPM) has been shown to be more representative of blood pressure levels in adult patients than are casual measurements of blood pressure. OBJECTIVE:To evaluate, by means of ABPM, the behavior of blood pressure in children with chronic renal failure submitted ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Koch VH,Furusawa EA,Ignes E,Okay Y,Mion Junior D

    更新日期:1999-10-01 00:00:00

  • The effect of crossing legs on blood pressure.

    abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3280b083a7

    authors: Adiyaman A,Tosun N,Elving LD,Deinum J,Lenders JW,Thien T

    更新日期:2007-06-01 00:00:00

  • Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use.

    abstract:BACKGROUND:We have developed a new blood pressure (BP)-measuring device with a double-cuff, and evaluated its accuracy and applicability for practical use. DESIGN:The double-cuff method features a small cuff placed in the centre of the compression cuff to detect the oscillation of arterial pulsation, by which algorith...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00126097-200310000-00005

    authors: Tochikubo O,Nishijima K,Ohshige K,Kimura K

    更新日期:2003-10-01 00:00:00

  • Ambulatory blood pressure variability: a conceptual review.

    abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000230

    authors: Zawadzki MJ,Small AK,Gerin W

    更新日期:2017-04-01 00:00:00

  • Sensitivity, specificity, and predictive values of a forearm blood pressure measurement method in severe obesity.

    abstract::For blood pressure assessment, it has been reported that forearm blood pressure measurement appears to be as valid as an upper-arm blood pressure measurement method in individuals with severe obesity when correlated to the intra-arterial method, considered as the gold standard. Sensitivity, specificity, and predictive...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000097

    authors: Leblanc MÈ,Cloutier L,Poirier P

    更新日期:2015-04-01 00:00:00

  • Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346d715

    authors: Yi J,Wan Y,Pan F,Yu X,Zhao H,Shang F,Xu Y

    更新日期:2011-08-01 00:00:00

  • The application of generalizability theory to blood pressure resting levels and mental stress responses.

    abstract::BACKGROUND: Blood pressure measurements taken in the clinic or laboratory are assumed to generalize to the world outside. This is true both of casual blood pressure measurements and of changes in blood pressure responses to stress. Such generalizability is crucial to the usefulness of blood pressure measurements as pr...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Gerin W,Christenfeld N,Pieper C

    更新日期:1996-12-01 00:00:00

  • Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    abstract:OBJECTIVE:To evaluate the accuracy of the YuWell YE680B oscillometric upper-arm blood pressure monitor for clinic and home blood pressure measurements in adults according to the American National Standards Institute/the Association for the Advancement of Medical Instrumentation/International Organization for Standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000405

    authors: Huang JF,Zhang W,Li Y,Wang JG

    更新日期:2019-12-01 00:00:00

  • The effects of renal denervation on resistant hypertension patients: a meta-analysis.

    abstract::We carried out this meta-analysis to assess the effects of renal denervation (RDN) on resistant hypertension patients. According to the collaborative review group search strategy, we searched MEDLINE (1996 to 2015.10); EBCO (1996 to 2015.10) and CNKI. A meta-analysis was carried out using RevMan 5.0. We identified 11 ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/MBP.0000000000000177

    authors: Zhang X,Wu N,Yan W,Zhou C,Guo H

    更新日期:2016-08-01 00:00:00

  • 'Diagnostic mode' improves adherence to the home blood pressure measurement schedule.

    abstract:BACKGROUND:The accuracy of home blood pressure measurement (HBPM) depends on adherence to the measurement schedule. We investigated the number of deviations from the requested schedule using an HBPM device equipped with a diagnostic mode that only allows patients to take a fixed number of BP readings at preset times. ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e328357352a

    authors: Wessel SE,van der Hoeven NV,Cammenga M,van Montfrans GA,van den Born BJ

    更新日期:2012-10-01 00:00:00

  • Acute effects of moderate-intensity and high-intensity exercise on hemodynamic and autonomic reactivity to the cold pressor test in young adults with excess body weight.

    abstract:OBJECTIVE:To investigate the effects of a single session of moderate-intensity and high-intensity interval exercise in cardiovascular reactivity to the cold pressor test in young adults with excess body weight. METHODS:Twenty-two subjects with excess body weight (23 ± 2 years; 30.0 ± 3.4 kg·m) performed three sessions...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000422

    authors: Meireles K,Peçanha T,Dias ARL,Souza KA,Araújo JA,Silva JS,Rezende DAN,Santos RJ,Cambri LT,Arsa G

    更新日期:2020-04-01 00:00:00

  • Propaq Neonatal monitor used with its own single- or with Critikon twin-hose cuffs: does it matter?.

    abstract::Some oscillometric non-invasive blood pressure (NIBP) monitors use twin-hose cuffs, whereas others use single-hose cuffs. The incompatibility hinders the transfer of patients from monitors using a single-hose cuff to monitors using twin-hose cuffs and vice versa. In particular, the Propaq Encore uses a single-hose cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Amoore JN

    更新日期:1997-12-01 00:00:00

  • Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians.

    abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000130223.80658.3d

    authors: Staal EM,Nygård OK,Omvik P,Gerdts E

    更新日期:2004-06-01 00:00:00

  • A strategy utilizing ambulatory monitoring and home and clinic blood pressure measurements to optimize the safety evaluation of noncardiovascular drugs with potential for hemodynamic effects: a report from the SYNERGY trial.

    abstract:OBJECTIVE:The aim of this study was to perform a blood pressure (BP) safety evaluation in patients with an overactive bladder receiving solifenacin (an antimuscarinic agent), mirabegron (a β3-adrenoceptor agonist), or both compared with placebo in the SYNERGY trial. PATIENTS AND METHODS:Patients were randomized to rec...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/MBP.0000000000000320

    authors: Weber MA,Chapple CR,Gratzke C,Herschorn S,Robinson D,Frankel JM,Ridder AM,Stoelzel M,Paireddy A,van Maanen R,White WB

    更新日期:2018-06-01 00:00:00