Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

Abstract:

:Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary contributors to the large numbers of patients with uncontrolled hypertension. A behaviour that can affect all patients, noncompliance is perplexing because it remains largely unrecognized in clinical practice. Several types of noncompliance exist, the 'drug holiday' being the most common. Good communication with the patient and the entire health care team is essential to improving patient compliance. Long-acting medications that provide good control of blood pressure beyond the 24 h dosing period should be considered as the drugs of choice in noncompliant hypertensive patients. This article discusses different types of compliance, methods of measuring compliance, and the clinical consequences of noncompliance in hypertension.

journal_name

Blood Press Monit

authors

Burnier M

subject

Has Abstract

pub_date

2000-01-01 00:00:00

pages

S31-4

eissn

1359-5237

issn

1473-5725

journal_volume

5 Suppl 1

pub_type

杂志文章,评审
  • Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS:Systolic and diastolic b...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000261

    authors: Kang YY,Chen Q,Liu CY,Li Y,Wang JG

    更新日期:2017-08-01 00:00:00

  • Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

    abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200502000-00005

    authors: Højgaard MV,Holstein-Rathlou NH,Agner E,Kanters JK

    更新日期:2005-02-01 00:00:00

  • Effects of race and sex on blood pressure and hemodynamic stress response as a function of the menstrual cycle.

    abstract::OBJECTIVE: To examine the influence of race and sex on responses to cardiovascular stress during two menstrual cycle phases. METHODS: Subjects were exposed to two stressors, a mirror star-tracing task and a speaking task. Blood pressure, heart rate, and impedance cardiography measures of reactivity were recorded. Wome...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Ahwal WN,Mills PJ,Kalshan DA,Nelesen RA

    更新日期:1997-08-01 00:00:00

  • White coat hypertension in children.

    abstract::Ambulatory blood pressure monitoring (ABPM) has become more widely used in the assessment of elevated blood pressure in children. The accurate diagnosis of white coat hypertension (WCH) is particularly important in children because detection of elevated blood pressure often results in expensive and invasive diagnostic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200008000-00001

    authors: Sorof JM

    更新日期:2000-08-01 00:00:00

  • Comparison of two automated sphygmomanometers for use in the office setting.

    abstract:OBJECTIVE:To compare readings obtained using two automated blood pressure (BP) recording devices, BpTRU and Omron 907, in a clinical setting. METHODS:Two series of 50 patients attending a hypertension unit for 24-h ambulatory BP monitoring had BP recorded either every 1 or every 2 min using BpTRU and Omron 907 devices...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32831e314f

    authors: Myers MG,Valdivieso M,Kiss A,Tobe SW

    更新日期:2009-02-01 00:00:00

  • Comparison of central blood pressure devices on the basis of a modified protocol of the European Society of Hypertension: application to the Centron cBP301.

    abstract:OBJECTIVES:Central blood pressure (cBP) and pulse pressure amplification (PPA) are receiving renewed interest with the increase in the availability of noninvasive techniques that enable its measurement. However, to date, there is no standardized protocol to validate their accuracy. Although invasive comparison seems in...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000028

    authors: Agnoletti D,Millasseau S,Topouchian J,Safar ME,Blacher J

    更新日期:2014-04-01 00:00:00

  • Prevalence and determinants of masked hypertension among obese individuals at the Yaoundé Central Hospital: a cross-sectional study in sub-Saharan Africa.

    abstract:OBJECTIVES:The aim of this study was to investigate the prevalence and associated factors of masked hypertension in obese patients in Yaounde. METHODS:We carried out a cross-sectional study from January to September 2017 at the National Obesity Center of the Yaounde Central Hospital. Masked hypertension was defined wh...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000457

    authors: Hamadou B,Amougou SN,Tchuendem Y,Nganou-Gnindjio CN,Mfeukeu-Kuate L,Foka AJ,Tankeu AT,Jingi AM,Menanga AP,Kingue S

    更新日期:2020-08-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200106000-00008

    authors: Wright JM,Mattu GS,Perry TL Jr,Gelferc ME,Strange KD,Zorn A,Chen Y

    更新日期:2001-06-01 00:00:00

  • Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect.

    abstract:OBJECTIVES:BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpT...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000189794.36230.a7

    authors: Culleton BF,McKay DW,Campbell NR

    更新日期:2006-02-01 00:00:00

  • Accuracy of the Microlife large-extra large-sized cuff (32-52 cm) coupled to an automatic oscillometric device.

    abstract::To determine the accuracy of the large-extra large-sized (L-XL) cuff (32-52 cm) coupled to a Microlife WatchBP Office ABI blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The L-XL cuff tested in this study is designed to provide...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328344c73c

    authors: Masiero S,Saladini F,Benetti E,Palatini P

    更新日期:2011-04-01 00:00:00

  • Blood pressure control in anticoagulated hypertensive patients.

    abstract:OBJECTIVE:To compare the methods of office blood pressure (BP) measurement and ambulatory blood pressure monitoring (ABPM) to ensure optimal BP control in hypertensive anticoagulated patients. PATIENTS AND METHODS:Seventy-eight patients who were receiving antihypertensive drugs and warfarin in a dose-adjusted approach...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000084

    authors: Guzet F,Bitigen A,Karabay CY,Cimen AO,Teyfik N

    更新日期:2015-02-01 00:00:00

  • Relationship between noninvasive and invasive blood pressure values in end-stage renal disease patients on dialysis.

    abstract:BACKGROUND:End-stage renal disease (ESRD) is complicated by high blood pressure (BP) and severe atherosclerosis, which may lead to different values of BP measured by invasive and noninvasive methods. However, the differences in BP values between these two methods and their possible mechanisms in ESRD have not been inve...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000026

    authors: Chen Y,Zhu Y,Chen C,Chen X,Pan H,Chen S,Tan X

    更新日期:2014-04-01 00:00:00

  • Assessment of antihypertensive efficacy by non-invasive ambulatory blood pressure monitoring.

    abstract::The session devoted to the usefulness of non-invasive ambulatory blood pressure monitoring (ABPM) in the evaluation of antihypertensive therapy allowed us to discuss a number of important issues. ABPM emerged as a widely accepted technique to measure blood pressure in clinical trials. Actually, it was generally consid...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Asmar R,Waeber B

    更新日期:1996-06-01 00:00:00

  • Validation of the A&D BP UA-651 device with a wide-range cuff for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    abstract::The aim of this study was to determine the accuracy of the A&D BP UA-651 device coupled to a wide-range cuff for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. The device was evaluated in 33 patients. The mean age of the patients was 56.5±15.1 year...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000100

    authors: Benetti E,Fania C,Palatini P

    更新日期:2015-06-01 00:00:00

  • Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs.

    abstract::Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national s...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000081

    authors: Neuhauser HK,Ellert U,Thamm M,Adler C

    更新日期:2015-02-01 00:00:00

  • Cardiovascular triggers and morning events.

    abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Chasen C,Muller JE

    更新日期:1998-02-01 00:00:00

  • Aortic systolic pressure derived with different calibration methods: associations to brachial systolic pressure in the general population.

    abstract:BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of thi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000319

    authors: Wassertheurer S,Hametner B,Mayer CC,Hafez A,Negishi K,Papaioannou TG,Protogerou AD,Sharman JE,Weber T

    更新日期:2018-06-01 00:00:00

  • Does the mean 24-h pulse rate from ambulatory blood pressure monitoring reflect the mean 24-h ventricular rate from Holter electrocardiogram in atrial fibrillation patients?

    abstract:BACKGROUND:Ambulatory blood pressure monitoring (ABPM) on the oscillometric method is applicable in patients with atrial fibrillation, but the mean pulse rate is or not similar to the ventricular rate from the Holter in atrial fibrillation patients remains unknown. METHODS:This study included 228 persistent atrial fib...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000481

    authors: Tong HY,Yu JH,Hong K,Chen J,Liu HY,Su H

    更新日期:2020-12-01 00:00:00

  • 'Diagnostic mode' improves adherence to the home blood pressure measurement schedule.

    abstract:BACKGROUND:The accuracy of home blood pressure measurement (HBPM) depends on adherence to the measurement schedule. We investigated the number of deviations from the requested schedule using an HBPM device equipped with a diagnostic mode that only allows patients to take a fixed number of BP readings at preset times. ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e328357352a

    authors: Wessel SE,van der Hoeven NV,Cammenga M,van Montfrans GA,van den Born BJ

    更新日期:2012-10-01 00:00:00

  • Validation of the TM-2564G device for in-hospital blood pressure measurement.

    abstract:OBJECTIVE:To perform clinical validation of the TM-2564G device for in-hospital blood pressure measurement according to the British Hypertension Society protocol. METHODS:The tests were carried out on 85 patients aged 19-82 years (41 male patients, mean age 50+/-19 years) with systolic blood pressure 75-219 mmHg and d...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200512000-00009

    authors: Kobalava ZD,Kotovskaya YV,Rodionov EV,Moiseev VS

    更新日期:2005-12-01 00:00:00

  • Nocturnal blood pressure nondipping in obese African-Americans.

    abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346a871

    authors: Napan S,Kwagyan J,Randall OS,Xu S,Ketete M,Maqbool AR

    更新日期:2011-06-01 00:00:00

  • Relationship of vitamin D and parathyroid hormone with the nocturnal blood pressure decline in hypertension.

    abstract:OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated h...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000286

    authors: Karadag MK,Secen O

    更新日期:2017-12-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Taking blood pressure -- no laughing matter!

    abstract:BACKGROUND:Humour is used commonly to relax subjects when their blood pressure is being measured. However the short-term effect of laughter on blood pressure is not described. METHODS:Sixteen normotensive volunteers had blood pressure measured using a validated automated oscillometric sphygmomanometric device (Omron 7...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200504000-00010

    authors: McMahon C,Mahmud A,Feely J

    更新日期:2005-04-01 00:00:00

  • Reproducibility of ambulatory blood pressure monitoring.

    abstract::OBJECTIVE: To investigate whether blood pressure monitoring is reproducible. DESIGN: Reproducibility of ambulatory blood pressure monitoring data was assessed by means of traditional and relatively new statistical methods, namely correlation coefficients, regression analysis and agreement analysis. METHODS: Ninety-one...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Musso NR,Lotti G

    更新日期:1996-04-01 00:00:00

  • The effect of Ramadan fasting on ambulatory blood pressure in treated hypertensive patients using diuretics.

    abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000451

    authors: Aslan S,Riza Demir A,Kahraman S,Memiç K,Avci Y,Gürbak İ,Karabulut E,Ertürk M

    更新日期:2020-08-01 00:00:00

  • Oscillometric sphygmomanometers: a critical appraisal of current technology.

    abstract:AIM:Blood pressure (BP), a key vital sign, monitors general health. Oscillometric devices are increasingly used for measurement, although their accuracy continues to be critically debated. A functional block diagram is used to review the components that affect accuracy. METHODS:A block diagram is presented covering th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0b013e32835026b0

    authors: Amoore JN

    更新日期:2012-04-01 00:00:00

  • Determination of accuracies of 10 models of home blood pressure monitors using an oscillometric simulator.

    abstract:BACKGROUND:Patients and doctors often use home blood pressure monitoring (HBPM) to assess the control of hypertension. Despite its popularity there has always been some uncertainty with regard to its accuracy, reliability, reproducibility, and comparability. Although there are pre-market HBPM standards of accuracy, the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-199904010-00007

    authors: Yarows SA,Amerena JV

    更新日期:1999-02-01 00:00:00

  • Dialysis-induced hypotension is associated with impaired aortic elasticity in patients undergoing chronic hemodialysis.

    abstract:BACKGROUND:The pathogenesis of dialysis-induced hypotension (DIH) is multifactorial and may include increased aortic stiffness. This study was undertaken to determine aortic elastic properties in patients undergoing hemodialysis with and without DIH, and to assess the effects of DIH on mortality. METHODS:Aortic stiffn...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e3282f13f75

    authors: Duman D,Demirtunc R,Erdogan B,Sahin GM,Karadag B

    更新日期:2008-04-01 00:00:00