Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use.

Abstract:

BACKGROUND:We have developed a new blood pressure (BP)-measuring device with a double-cuff, and evaluated its accuracy and applicability for practical use. DESIGN:The double-cuff method features a small cuff placed in the centre of the compression cuff to detect the oscillation of arterial pulsation, by which algorithms for the determination of systolic BP (SBP) and diastolic BP (DBP) were rendered more objective than with the conventional oscillometric method. Algorithms for automatic BP determination were developed from the oscillation data taken with the small cuff from 217 men and 256 women, and then installed in the Terumo ES-H55 device (length: 17 cm, weight: 120 g). This ES-H55 device was tested on 87 subjects (65 hypertensives and 22 normotensives) to compare its accuracy with that of the auscultatory method according to the AAMI SP-10 protocol. RESULTS:Using Bland and Altman scatter plots, the difference in SBP between the ES-H55 device and the auscultatory method was within +/- 5 mmHg in 88% of subjects, and within +/- 10 mmHg in 97% (mean difference +/- SD: 0.2 +/- 3.9 mmHg). The difference in DBP was within +/- 5 mmHg in 80%, and within +/- 10 mmHg in 97% (difference: -0.1 +/- 4.6 mmHg). These results satisfied AAMI guidelines, and this device was easy to use. CONCLUSIONS:The ES-H55 device is compact and light, with clear algorithms for the determination of BP, and satisfies AAMI criteria, so that it is considered a useful BP-measuring device that could be used instead of a mercury sphygmomanometer by nurses and doctors in hospital wards.

journal_name

Blood Press Monit

authors

Tochikubo O,Nishijima K,Ohshige K,Kimura K

doi

10.1097/00126097-200310000-00005

subject

Has Abstract

pub_date

2003-10-01 00:00:00

pages

203-9

issue

5

eissn

1359-5237

issn

1473-5725

journal_volume

8

pub_type

临床试验,杂志文章
  • Ambulatory blood pressure monitoring in pediatric end-stage renal disease: chronic dialysis and transplantation.

    abstract::Hypertension is highly prevalent in pediatric patients with end-stage renal disease (ESRD). Ambulatory blood pressure monitoring (ABPM) has been used to characterize the altered circadian blood pressure patterns in ESRD in order to improve our understanding of the blood pressure dysregulation that occurs in these chil...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Sorof JM

    更新日期:1999-06-01 00:00:00

  • Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    abstract:OBJECTIVE:To evaluate the accuracy of the YuWell YE680B oscillometric upper-arm blood pressure monitor for clinic and home blood pressure measurements in adults according to the American National Standards Institute/the Association for the Advancement of Medical Instrumentation/International Organization for Standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000405

    authors: Huang JF,Zhang W,Li Y,Wang JG

    更新日期:2019-12-01 00:00:00

  • Hypertension in psoriasis patients: based on office and ambulatory blood pressure measurement.

    abstract:OBJECTIVE:Psoriasis is a chronic inflammatory disorder, which is associated with high risk of metabolic comorbidities. Hypertension (HTN) is among the most common and serious associations. In this study, we aimed to evaluate HTN in psoriatic patients through office and ambulatory blood pressure monitoring (ABPM). MATE...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000489

    authors: Abedini R,Najafi MT,Azizpour A,Nasimi M,Darreshiri M,Teymourpour A

    更新日期:2020-12-01 00:00:00

  • Interindividual and intraindividual variation in pulse wave velocity measurements in a male population.

    abstract:OBJECTIVE:Pulse wave velocity (PWV) is a measure of arterial stiffness and a marker for cardiovascular disease. Although commonly used, there are only a few reports investigating the intersession and intrasession variability in PWV measurements, the determination of which is important in a mixed population when using P...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000052

    authors: Tripkovic L,Hart KH,Frost GS,Lodge JK

    更新日期:2014-08-01 00:00:00

  • Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor.

    abstract::OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various ar...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Baumgart P,Kamp J

    更新日期:1998-10-01 00:00:00

  • Use of feedback on medium-term blood pressure measurement skills in medical students: a randomized controlled trial.

    abstract:BACKGROUND:The objective of this study was to assess the effect of feedback on medium-term blood pressure (BP) measurement skills in medical students versus a control group. METHODS:A randomized controlled trial in first-year medical students was conducted. After theoretical-practical training on measuring BP, the stu...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000433

    authors: Bastos E Castro MA,Lucchetti ALG,Tibiriçá SHC,da Silva Ezequiel O,Lucchetti G

    更新日期:2020-06-01 00:00:00

  • Nocturnal blood pressure nondipping in obese African-Americans.

    abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346a871

    authors: Napan S,Kwagyan J,Randall OS,Xu S,Ketete M,Maqbool AR

    更新日期:2011-06-01 00:00:00

  • Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect.

    abstract:OBJECTIVES:BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpT...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000189794.36230.a7

    authors: Culleton BF,McKay DW,Campbell NR

    更新日期:2006-02-01 00:00:00

  • Prognostic value of average real variability of systolic blood pressure in elderly treated hypertensive patients.

    abstract:OBJECTIVE:The independent prognostic significance of ambulatory blood pressure variability in the elderly is incompletely clear. We investigated the prognostic value of average real variability of 24-hour blood pressure in elderly treated hypertensive patients. METHODS:The occurrence of a combined end-point including ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000381

    authors: Coccina F,Pierdomenico AM,Cuccurullo C,Pierdomenico SD

    更新日期:2019-08-01 00:00:00

  • Validation protocols for blood pressure-measuring devices: status quo and development needs.

    abstract::Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000150

    authors: Beime B,Deutsch C,Gomez T,Zwingers T,Mengden T,Bramlage P

    更新日期:2016-02-01 00:00:00

  • Reduction of morning blood pressure surge after treatment with nifedipine GITS at bedtime, but not upon awakening, in essential hypertension.

    abstract:OBJECTIVES:The extent of morning blood pressure (BP) surge upon wakening has been associated with increased incidence of stroke and cardiovascular mortality. This trial investigated the antihypertensive efficacy and effects on the morning BP surge of awakening versus bedtime administration of nifedipine in essential hy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e32832e0d80

    authors: Hermida RC,Ayala DE,Mojón A,Alonso I,Fernández JR

    更新日期:2009-08-01 00:00:00

  • Association of vitamin D deficiency with arterial stiffness in newly diagnosed hypertension.

    abstract:OBJECTIVE:Vitamin D has beneficial effects on vascular endothelial function, blood pressure (BP) and arterial stiffness. Arterial stiffness increases in early-stage hypertensive patients and it is a strong predictor of cardiovascular morbidity and mortality. The purpose of this study was to assess the association betwe...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000497

    authors: Cakal S,Çakal B,Karaca O

    更新日期:2020-11-23 00:00:00

  • Ambulatory blood pressure variability: a conceptual review.

    abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000230

    authors: Zawadzki MJ,Small AK,Gerin W

    更新日期:2017-04-01 00:00:00

  • Effects of salt loading and potassium supplement on the circadian blood pressure profile in salt-sensitive Chinese patients.

    abstract:BACKGROUND AND OBJECTIVE:Salt-sensitive (SS) patients more frequently showed a nondipper blood pressure pattern and were associated with more serious target organ damage than non-SS patients. We aimed to investigate whether potassium supplement can improve the blunted nocturnal blood pressure fall in SS patients expose...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000276

    authors: Guo TS,Dai Y,Ren KY,Mu JJ,Ren J,Wang D,Wang Y,Chu C,Li Y,Yuan ZY

    更新日期:2017-12-01 00:00:00

  • Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32834b4431

    authors: Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C

    更新日期:2011-10-01 00:00:00

  • Blood pressure assessment during resistance exercise: comparison between auscultation and Finapres.

    abstract:OBJECTIVES:The objective of this study was to test whether the auscultatory method and Finapres provide similar readings for blood pressure response during two resistance exercise protocols of different intensities, and to gain some insight into whether auscultation can be used to monitor cardiovascular stress during r...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32809ef9f1

    authors: Polito MD,Farinatti PT,Lira VA,Nobrega AC

    更新日期:2007-04-01 00:00:00

  • Relationship of vitamin D and parathyroid hormone with the nocturnal blood pressure decline in hypertension.

    abstract:OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated h...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000286

    authors: Karadag MK,Secen O

    更新日期:2017-12-01 00:00:00

  • Identification of subjects with white-coat hypertension and persistently normal ambulatory blood pressure.

    abstract::OBJECTIVE: To assess the spontaneous changes in clinic blood pressure, ambulatory blood pressure (ABP) and left ventricular structure in untreated subjects with white-coat hypertension (WCH). DESIGN: A prospective observational study. PATIENTS AND METHODS: In 83 untreated subjects with WCH, 24 h non-invasive ABP monit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Verdecchia P,Schillaci G,Borgioni C,Ciucci A,Gattobigio R,Sacchi N,Guerrieri M,Comparato E,Porcellati C

    更新日期:1996-06-01 00:00:00

  • Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review.

    abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000344

    authors: Sprague E,Padwal RS

    更新日期:2018-10-01 00:00:00

  • Conventional and ambulatory measurements of blood pressure in old patients with isolated systolic hypertension: baseline observations in the Syst-Eur trial.

    abstract::OBJECTIVES: To compare clinic and am measurements of blood pressure in old patients with isolated systolic hypertension and their reproducibilities. PATIENTS: In total 610 patients aged >/= 60 years with isolated systolic hypertension detected by clinic measurement were monitored during the placebo run-in phase of the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Emelianov D,Thijs L,Staessen JA,Celis H,Clement D,Davidson C,Gasowski J,Gil-Extremera B,Fogari R,Jääskivi M,Lehtonen A,Nedogoda S,O'Brien E,Palatini P,Parati G,Salvetti A,Vanhanen H,Webster J,Fagard R

    更新日期:1998-06-01 00:00:00

  • Impact of choosing the closest rather than the mean auscultatory blood pressure value on the European Society of Hypertension International Protocol device validation results.

    abstract:OBJECTIVE:When calculating the difference between alternating auscultatory reference standard (ARS) and the automated device-under-test (DUT) blood pressure (BP) measurements, the European Society of Hypertension International Protocol (ESH-IP) allows investigators to choose the closest ARS value to the DUT value, rath...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000454

    authors: Padwal R,Wood PW,McLean D,Ringrose JS

    更新日期:2020-08-01 00:00:00

  • Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards

    abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328330c873

    authors: Polo Friz H,Facchetti R,Primitz L,Beltrame L,Galbiati V,Ricioppo A,Bombelli M,Sega R

    更新日期:2009-10-01 00:00:00

  • Morning hypertension in chronic kidney disease is sustained type, but not surge type.

    abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32835026c6

    authors: Mizuno M,Fukuda M,Miura T,Wakamatsu T,Naito T,Sato R,Togawa H,Sasakawa Y,Tomonari T,Ono M,Kato Y,Ichikawa T,Shirasawa Y,Ito A,Yoshida A,Kimura G

    更新日期:2012-02-01 00:00:00

  • The effects of various definitions of dipping and daytime and night-time on the characterization of 24 h profiles of blood pressure.

    abstract:BACKGROUND:Ambulatory blood pressure monitoring allows characterization of the patient's average blood pressure load as well as various profiles of blood pressure. Results from clinical studies suggest that dippers (patients whose blood pressures decrease during night-time) have a lower risk of cardiovascular events th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200002000-00004

    authors: Butkevich A,Phillips RA,Sheinart KF,Tuhrim S

    更新日期:2000-02-01 00:00:00

  • The German Hypertension League (Deutsche Hochdruckliga) Quality Seal Protocol for blood pressure-measuring devices: 15-year experience and results from 105 devices for home blood pressure control.

    abstract:OBJECTIVE:The German Hypertension League (Deutsche Hochdruckliga) established a program to assess the accuracy and reliability of blood pressure (BP)-measuring devices in 1999 (Quality Seal Protocol). Here, we report on the results of a testing series of 105 devices designed for BP self-measurement. METHODS:The test p...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000186

    authors: Tholl U,Lüders S,Bramlage P,Dechend R,Eckert S,Mengden T,Nürnberger J,Sanner B,Anlauf M

    更新日期:2016-08-01 00:00:00

  • Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

    abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200502000-00005

    authors: Højgaard MV,Holstein-Rathlou NH,Agner E,Kanters JK

    更新日期:2005-02-01 00:00:00

  • Blood pressure measurement and the guidelines: a proposed new algorithm for the diagnosis of hypertension.

    abstract::Current hypertension guidelines continue to base management decisions on the office BP as recorded by mercury sphygmomanometry. The imminent disappearance of mercury from the workplace for environmental and safety reasons provides an opportunity to re-assess how a diagnosis of hypertension is made. There are now sever...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1097/00126097-200412000-00002

    authors: Myers MG

    更新日期:2004-12-01 00:00:00

  • Aortic systolic pressure derived with different calibration methods: associations to brachial systolic pressure in the general population.

    abstract:BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of thi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000319

    authors: Wassertheurer S,Hametner B,Mayer CC,Hafez A,Negishi K,Papaioannou TG,Protogerou AD,Sharman JE,Weber T

    更新日期:2018-06-01 00:00:00

  • Blood pressure control in anticoagulated hypertensive patients.

    abstract:OBJECTIVE:To compare the methods of office blood pressure (BP) measurement and ambulatory blood pressure monitoring (ABPM) to ensure optimal BP control in hypertensive anticoagulated patients. PATIENTS AND METHODS:Seventy-eight patients who were receiving antihypertensive drugs and warfarin in a dose-adjusted approach...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000084

    authors: Guzet F,Bitigen A,Karabay CY,Cimen AO,Teyfik N

    更新日期:2015-02-01 00:00:00

  • Frequency of spontaneous fist clenching during routine blood pressure measurements and its effect on measurement accuracy.

    abstract:BACKGROUND:Guidelines for office blood pressure reading techniques do not warn us about the possibility that patients may clench their fist during cuff-inflation. It is unknown how often patients do this, and what effect it has on measured blood pressure readings. DESIGN AND METHODS:We registered double blood pressure...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200206000-00001

    authors: Smulders YM,Godfried MH,van Montfrans GA

    更新日期:2002-06-01 00:00:00