Conventional and ambulatory measurements of blood pressure in old patients with isolated systolic hypertension: baseline observations in the Syst-Eur trial.

Abstract:

:OBJECTIVES: To compare clinic and am measurements of blood pressure in old patients with isolated systolic hypertension and their reproducibilities. PATIENTS: In total 610 patients aged >/= 60 years with isolated systolic hypertension detected by clinic measurement were monitored during the placebo run-in phase of the Syst-Eur trial. METHODS: The time-weighted 24 h blood pressure, clock-time day and night blood pressures, the cumulative-sum-derived crest and trough blood pressures and the high and low blood pressure levels according to the square-wave model were computed. The daily alteration between the high and low spans of blood pressure was quantified using the day-night difference, the cumulative-sum-derived magnitude of circadian alteration, the Fourier amplitude and the difference between the high and low blood pressure levels of the square-wave model. RESULTS: The daytime am systolic blood pressure was, on average, 21 mmHg lower than the clinic systolic blood pressure, whereas diastolic pressure was, on average, similar with both techniques of measurement. Clinic levels of blood pressure in the 141 patients who underwent repeat measurements and the parameters describing the difference between the daily high and low spans of blood pressure were equally reproducible. However, both were less reproducible than the ambulatory blood pressure levels. The reproducibility coefficients, expressed as percentages of near maximum variation, were 49 and 50% for the clinic systolic and diastolic blood pressures, 30 and 32% for the mean 24 h systolic and diastolic blood pressures and 45-55% for the parameters describing the daily alteration between the high and low spans of blood pressure. CONCLUSION: Values of blood pressure in old patients with isolated systolic hypertension were more reproducible for ambulatory than they were for clinic measurements. Levels in patients selected because they have a high clinic blood pressure may be substantially higher with conventional than they are with daytime ambulatory measurement. The prognostic significance of this difference for the present patients is currently under investigation.

journal_name

Blood Press Monit

authors

Emelianov D,Thijs L,Staessen JA,Celis H,Clement D,Davidson C,Gasowski J,Gil-Extremera B,Fogari R,Jääskivi M,Lehtonen A,Nedogoda S,O'Brien E,Palatini P,Parati G,Salvetti A,Vanhanen H,Webster J,Fagard R

subject

Has Abstract

pub_date

1998-06-01 00:00:00

pages

173-180

issue

3

eissn

1359-5237

issn

1473-5725

journal_volume

3

pub_type

杂志文章
  • The Maxi Stabil 3: validation of an aneroid device according to a modified British Hypertension Society protocol.

    abstract:BACKGROUND:Measuring blood pressure with mercury-independent alternatives is rapidly gaining attention. Mercury will be phased out of clinical use as a result of environmental, health and safety concerns and it is of vital importance that any alternative to mercury has to be of a recognized standard. We assessed the ac...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200304000-00005

    authors: Reinders A,Jones CR,Cuckson AC,Shennan AH

    更新日期:2003-04-01 00:00:00

  • The effects of renal denervation on resistant hypertension patients: a meta-analysis.

    abstract::We carried out this meta-analysis to assess the effects of renal denervation (RDN) on resistant hypertension patients. According to the collaborative review group search strategy, we searched MEDLINE (1996 to 2015.10); EBCO (1996 to 2015.10) and CNKI. A meta-analysis was carried out using RevMan 5.0. We identified 11 ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/MBP.0000000000000177

    authors: Zhang X,Wu N,Yan W,Zhou C,Guo H

    更新日期:2016-08-01 00:00:00

  • Clinical test of a blood pressure measurement device with a wrist cuff.

    abstract::OBJECTIVE: To test a semi-automatic oscillometric blood pressure measurement device with a wrist cuff. METHODS: Two different test methods, partly based on European and American standards for clinical investigation of non-invasive sphygmomanometers, were worked out and compared. Mostly German guidelines were considere...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Wonka F,Thümmler M,Schöppe A

    更新日期:1996-08-01 00:00:00

  • Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor.

    abstract::OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various ar...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Baumgart P,Kamp J

    更新日期:1998-10-01 00:00:00

  • A strategy utilizing ambulatory monitoring and home and clinic blood pressure measurements to optimize the safety evaluation of noncardiovascular drugs with potential for hemodynamic effects: a report from the SYNERGY trial.

    abstract:OBJECTIVE:The aim of this study was to perform a blood pressure (BP) safety evaluation in patients with an overactive bladder receiving solifenacin (an antimuscarinic agent), mirabegron (a β3-adrenoceptor agonist), or both compared with placebo in the SYNERGY trial. PATIENTS AND METHODS:Patients were randomized to rec...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/MBP.0000000000000320

    authors: Weber MA,Chapple CR,Gratzke C,Herschorn S,Robinson D,Frankel JM,Ridder AM,Stoelzel M,Paireddy A,van Maanen R,White WB

    更新日期:2018-06-01 00:00:00

  • Endothelial dysfunction predicted increased left atrial volume index in newly diagnosed nondiabetic hypertensive patients.

    abstract:BACKGROUND:Arterial hypertension is associated with cardiovascular morbidity and mortality. It was previously shown that left atrium volume increase associated with mortality and atherosclerotic heart disease. The aim of the present study was to demonstrate the value of endothelial dysfunction in predicting left atrium...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000419

    authors: Çetin M,Erdoğan T,Kiriş T,Aykan AÇ,Çinier G,Emlek N,Durak H,Kalaycioğlu E,Yilmaz AS

    更新日期:2020-04-01 00:00:00

  • Repeatability of blood pressure measurements during treadmill exercise.

    abstract:OBJECTIVE:Blood pressure measurements during exercise are difficult to obtain but are used widely in clinical practice. The objective of this study was to investigate the repeatability of blood pressure measurements and gas exchange parameters during treadmill exercise. METHODS:Participants were 10 healthy and nonsmok...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e328351de5c

    authors: Instebø A,Helgheim V,Greve G

    更新日期:2012-04-01 00:00:00

  • Effects of race and sex on blood pressure and hemodynamic stress response as a function of the menstrual cycle.

    abstract::OBJECTIVE: To examine the influence of race and sex on responses to cardiovascular stress during two menstrual cycle phases. METHODS: Subjects were exposed to two stressors, a mirror star-tracing task and a speaking task. Blood pressure, heart rate, and impedance cardiography measures of reactivity were recorded. Wome...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Ahwal WN,Mills PJ,Kalshan DA,Nelesen RA

    更新日期:1997-08-01 00:00:00

  • The effect of crossing legs on blood pressure: a randomized single-blind cross-over study.

    abstract:BACKGROUND:Although there is a theoretical basis for crossing legs to increase blood pressure, there are no published data addressing this question. As a result guidelines for measurement of blood pressure are not consistent in recommending that patients legs should not be crossed during measurement. OBJECTIVE:To dete...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Peters GL,Binder SK,Campbell NR

    更新日期:1999-04-01 00:00:00

  • Effects of the angiotensin II receptor blockers telmisartan versus valsartan in combination with hydrochlorothiazide: a large, confirmatory trial.

    abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e3282f3859d

    authors: White WB,Murwin D,Chrysant SG,Koval SE,Davidai G,Guthrie R

    更新日期:2008-02-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

    abstract::Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary cont...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Burnier M

    更新日期:2000-01-01 00:00:00

  • The effect of crossing legs on blood pressure.

    abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3280b083a7

    authors: Adiyaman A,Tosun N,Elving LD,Deinum J,Lenders JW,Thien T

    更新日期:2007-06-01 00:00:00

  • Evaluation, management, and referral of elderly emergency department patients with elevated blood pressure.

    abstract:OBJECTIVES:To determine blood pressure (BP) reassessment rates and to describe the evaluation and outpatient referral rates of elderly emergency department (ED) patients with elevated BP. METHODS:This was a retrospective cohort of patients who were at least 60 years, presented with a systolic BP of at least 140 mmHg o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e328332fd40

    authors: Baumann BM,Cienki JJ,Cline DM,Egging D,Lehrmann JF,Tanabe P

    更新日期:2009-12-01 00:00:00

  • Propaq Neonatal monitor used with its own single- or with Critikon twin-hose cuffs: does it matter?.

    abstract::Some oscillometric non-invasive blood pressure (NIBP) monitors use twin-hose cuffs, whereas others use single-hose cuffs. The incompatibility hinders the transfer of patients from monitors using a single-hose cuff to monitors using twin-hose cuffs and vice versa. In particular, the Propaq Encore uses a single-hose cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Amoore JN

    更新日期:1997-12-01 00:00:00

  • Comparison of central blood pressure devices on the basis of a modified protocol of the European Society of Hypertension: application to the Centron cBP301.

    abstract:OBJECTIVES:Central blood pressure (cBP) and pulse pressure amplification (PPA) are receiving renewed interest with the increase in the availability of noninvasive techniques that enable its measurement. However, to date, there is no standardized protocol to validate their accuracy. Although invasive comparison seems in...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000028

    authors: Agnoletti D,Millasseau S,Topouchian J,Safar ME,Blacher J

    更新日期:2014-04-01 00:00:00

  • Aortic systolic pressure derived with different calibration methods: associations to brachial systolic pressure in the general population.

    abstract:BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of thi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000319

    authors: Wassertheurer S,Hametner B,Mayer CC,Hafez A,Negishi K,Papaioannou TG,Protogerou AD,Sharman JE,Weber T

    更新日期:2018-06-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

    abstract::Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early...

    journal_title:Blood pressure monitoring

    pub_type: 传,历史文章,杂志文章

    doi:10.1097/MBP.0b013e3283380e1e

    authors: Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

    更新日期:2010-04-01 00:00:00

  • Effect of fasting on 24-h blood pressure values of individuals with no previous history of hypertension.

    abstract:OBJECTIVE:We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. PATIENTS AND METHODS:This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage chang...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0000000000000244

    authors: Seker A,Demirci H,Ocakoglu G,Aydin U,Ucar H,Yildiz G,Yaman O

    更新日期:2017-10-01 00:00:00

  • Validation of the A&D UA-774 (UA-767Plus) device for self-measurement of blood pressure.

    abstract:OBJECTIVES:To determine the accuracy of the UA-774 (UA-767Plus) blood pressure monitor developed by the A&D Company. METHODS:Device evaluation was performed according to the modified British Hypertension Society (BHS) protocol released in 1993. Eighty-five subjects with characteristics outlined in the BHS protocol wer...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200408000-00008

    authors: Verdecchia P,Angeli F,Poeta F,Reboldi GP,Borgioni C,Pittavini L,Porcellati C

    更新日期:2004-08-01 00:00:00

  • Relationship between noninvasive and invasive blood pressure values in end-stage renal disease patients on dialysis.

    abstract:BACKGROUND:End-stage renal disease (ESRD) is complicated by high blood pressure (BP) and severe atherosclerosis, which may lead to different values of BP measured by invasive and noninvasive methods. However, the differences in BP values between these two methods and their possible mechanisms in ESRD have not been inve...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000026

    authors: Chen Y,Zhu Y,Chen C,Chen X,Pan H,Chen S,Tan X

    更新日期:2014-04-01 00:00:00

  • Blood pressure in acute ischemic stroke and mortality: a study with noninvasive blood pressure monitoring.

    abstract:BACKGROUND:In acute ischemic stroke, a transient elevation of blood pressure is common; its significance and its relationship with the neurological outcome are still unclear. METHODS:In 71 consecutive patients with acute ischemic stroke, aged 25-94 years, admitted to our unit, we investigated the relationships between...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209077.23084.93

    authors: Sartori M,Benetton V,Carraro AM,Calò LA,Macchini L,Giantin V,Tosato F,Pessina AC,Semplicini A

    更新日期:2006-08-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Do we undertreat hypertensive smokers? A comparison between smoking and non-smoking hypertensives.

    abstract::The acute effect of smoking is a rise in blood pressure and heart rate. Nevertheless, in several epidemiologic studies, smokers tend to have a slightly lower office blood pressure than non-smokers. We studied the 24 h ambulatory blood pressure consecutively in hypertensive smokers (> or = 10 cigarettes per day, n = 26...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200010000-00004

    authors: Bang LE,Buttenschøn L,Kristensen KS,Svendsen TL

    更新日期:2000-10-01 00:00:00

  • Hidden errors of aneroid sphygmomanometers.

    abstract:BACKGROUND:Measurement of blood pressure remains the most commonly performed screening test in medical practice. With the likely removal of mercury sphygmomanometers from the workplace alternative devices are required. Of these the aneroid sphygmomanometer is popular both in the community and hospital setting. We inves...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200212000-00003

    authors: Waugh JJ,Gupta M,Rushbrook J,Halligan A,Shennan AH

    更新日期:2002-12-01 00:00:00

  • Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32834b4431

    authors: Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C

    更新日期:2011-10-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • Reduction of morning blood pressure surge after treatment with nifedipine GITS at bedtime, but not upon awakening, in essential hypertension.

    abstract:OBJECTIVES:The extent of morning blood pressure (BP) surge upon wakening has been associated with increased incidence of stroke and cardiovascular mortality. This trial investigated the antihypertensive efficacy and effects on the morning BP surge of awakening versus bedtime administration of nifedipine in essential hy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e32832e0d80

    authors: Hermida RC,Ayala DE,Mojón A,Alonso I,Fernández JR

    更新日期:2009-08-01 00:00:00