Comparison of central blood pressure devices on the basis of a modified protocol of the European Society of Hypertension: application to the Centron cBP301.

Abstract:

OBJECTIVES:Central blood pressure (cBP) and pulse pressure amplification (PPA) are receiving renewed interest with the increase in the availability of noninvasive techniques that enable its measurement. However, to date, there is no standardized protocol to validate their accuracy. Although invasive comparison seems intellectually ideal, it will soon raise technical and ethical issues with the growing number of devices to be validated. We proposed a modified ESH-IP2010 protocol for electronic brachial devices to validate noninvasively systolic cBP and pulse pressure amplification, and used it to compare the newly commercialized Centron cBP301 device with radial tonometry SphygmoCor. METHODS:Radial tonometric SphygmoCor measurements were performed four times alternated with three Centron cBP301 measurements. Each Centron recording was compared with the most favourable SphygmoCor recordings performed immediately before or after and calibrated with Centron peripheral systolic and diastolic blood pressure measurements. RESULTS:Following protocol requirements, 33 individuals (21 men and 12 women) were recruited in the low, medium and high peripheral BP range. Systolic cBP varied from 88 to 188 and the difference between the devices was -0.33±3.28 mmHg (m±SD). It fell within the ESH-IP2010 pass requirements for the number of measurements within 5, 10 and 15 mmHg. The PPA varied from 1.13 to 2.09 and the difference between devices was -0.03±0.11, which showed good agreement for the PPA. CONCLUSION:The Centron cBP301 device was compared with the similarly calibrated SphygmoCor with a modified ESH-IP2010 protocol. It provided accurate measurements of systolic cBP and PPratio.

journal_name

Blood Press Monit

authors

Agnoletti D,Millasseau S,Topouchian J,Safar ME,Blacher J

doi

10.1097/MBP.0000000000000028

subject

Has Abstract

pub_date

2014-04-01 00:00:00

pages

103-8

issue

2

eissn

1359-5237

issn

1473-5725

journal_volume

19

pub_type

杂志文章
  • Nocturnal blood pressure nondipping in obese African-Americans.

    abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346a871

    authors: Napan S,Kwagyan J,Randall OS,Xu S,Ketete M,Maqbool AR

    更新日期:2011-06-01 00:00:00

  • Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing.

    abstract:OBJECTIVE:The Welch Allyn Pro BP 2000, an automated sphygmomanometer, was subjected to ANSI/AAMI/ISO testing. PATIENTS AND METHODS:The protocol used was the same-arm sequential procedure described in the ANSI/AAMI/ISO 2013 Standard. Eight-eight (53 adults and 35 children aged 3-12 years old) patients completed testing...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000350

    authors: Alpert BS

    更新日期:2018-12-01 00:00:00

  • Left ventricular hypertrophy and preclinical impaired glucose tolerance and diabetes mellitus contribute to abnormal left ventricular diastolic function in hypertensive patients.

    abstract:BACKGROUND:Impaired left ventricular diastolic function is not uncommon in patients with either diabetes mellitus or hypertension. This study was carried out to assess the contribution of left ventricular hypertrophy, high blood pressure, preclinical impaired glucose tolerance and diabetes mellitus to left ventricular ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000172710.82287.36

    authors: Salmasi AM,Rawlins S,Dancy M

    更新日期:2005-10-01 00:00:00

  • Quality of blood pressure phenotype in the Nigerian Population Research on Environment Gene and Health.

    abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000053

    authors: Odili AN,Ameh VO,Ogedengbe JO,Staessen JA

    更新日期:2014-08-01 00:00:00

  • An extended validation of the ScottCare 320 ambulatory blood pressure monitor: recommendations for clinical application.

    abstract:OBJECTIVES:The purpose of this study was to validate the ScottCare 320 ambulatory blood pressure monitor (ABPM) using both group-level and individual-level validation procedures. The group-level validation followed a modified protocol of the European Hypertension Society's validation protocol. The individual-level vali...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e32835f4fc7

    authors: Zawadzki MJ,Vandekar L,Smyth JM,Haas D,Gerin W

    更新日期:2013-06-01 00:00:00

  • Feasibility of oscillometric aortic pressure and stiffness assessment using the VaSera VS-1500: comparison with a common tonometric method.

    abstract:OBJECTIVES:A number of operator-independent oscillometric devices to measure hemodynamics and arterial stiffness became available recently, but some and in particular VaSera VS-1500 do not provide estimates of aortic pressures and aortic pulse wave velocity (aPWV). The aim of this work was the retrospective application...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000137

    authors: Endes S,Bachler M,Li Y,Mayer C,Hanssen H,Hametner B,Schmidt-Trucksäss A,Wassertheurer S

    更新日期:2015-10-01 00:00:00

  • A psychophysiologic reaction to application of ambulatory blood pressure monitor: fact or artifact?

    abstract:BACKGROUND:The study investigated the clinical significance of relatively high blood pressure (BP) elevations during the calibration of the ambulatory blood pressure monitor (ABPM). METHODS:Inferences were drawn from the analysis of differences between 'M', the average of five manually triggered responses, and 'W', th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328340ff51

    authors: Yanovski A,Townsend RR,Virginia F,Michael C

    更新日期:2011-02-01 00:00:00

  • From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

    abstract::Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early...

    journal_title:Blood pressure monitoring

    pub_type: 传,历史文章,杂志文章

    doi:10.1097/MBP.0b013e3283380e1e

    authors: Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

    更新日期:2010-04-01 00:00:00

  • Percentiles of waist-to-sitting-height ratio and its relationship with obesity and elevated blood pressure among children and adolescents in Shandong, China.

    abstract:BACKGROUND:Waist circumference (WC) and related anthropometric indices have been recognized as useful measures of abdominal obesity. However, little is known about the association of waist-to-sitting-height ratio (WSHtR) with obesity and elevated blood pressure (BP). PARTICIPANTS AND METHODS:Data for this study were o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000154

    authors: Zhang YX,Zhao JS,Chu ZH

    更新日期:2016-02-01 00:00:00

  • Blood pressure cuff comparability study.

    abstract:BACKGROUND:Manufacturer-supplied blood pressure (BP) cuffs are part of the automatic oscillometric BP devices algorithm. MATERIALS AND METHODS:This study assessed the differences in BP values using the Omron HEM 907-XL (Omron) device with two types of cuffs: the Baum cuff (BC) and the supplied Omron cuff (OC). A sampl...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000208

    authors: Ostchega Y,Nwankwo T,Zhang G,Chiappa M

    更新日期:2016-12-01 00:00:00

  • Blood pressure assessment during resistance exercise: comparison between auscultation and Finapres.

    abstract:OBJECTIVES:The objective of this study was to test whether the auscultatory method and Finapres provide similar readings for blood pressure response during two resistance exercise protocols of different intensities, and to gain some insight into whether auscultation can be used to monitor cardiovascular stress during r...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32809ef9f1

    authors: Polito MD,Farinatti PT,Lira VA,Nobrega AC

    更新日期:2007-04-01 00:00:00

  • Comparison of the effects of two different teaching methods in blood pressure measurement training: a randomized controlled study.

    abstract:OBJECTIVE:To compare the effects of a high-fidelity simulator and conventional teaching model used during blood pressure measurement training on students' self-confidence, self-efficacy and anxiety levels. METHODS:A randomized controlled trial design was used. The study was conducted on 59 first-year nursing students ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000401

    authors: Terzi B,Topbaş E,Bingöl G,Mavi Aydoğdu SG

    更新日期:2019-12-01 00:00:00

  • Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension.

    abstract:OBJECTIVE:The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution. METHODS:Blood pressure indices, blood pressure loads and standard deviation scores were c...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32832ce11e

    authors: Jones DP,Richey PA,Alpert BS

    更新日期:2009-06-01 00:00:00

  • Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016.

    abstract:BACKGROUND:Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC). OBJECTIVE:To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems. PATIENTS...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000349

    authors: Ostchega Y,Hughes JP,Nwankwo T,Zhang G

    更新日期:2018-12-01 00:00:00

  • Taking blood pressure -- no laughing matter!

    abstract:BACKGROUND:Humour is used commonly to relax subjects when their blood pressure is being measured. However the short-term effect of laughter on blood pressure is not described. METHODS:Sixteen normotensive volunteers had blood pressure measured using a validated automated oscillometric sphygmomanometric device (Omron 7...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200504000-00010

    authors: McMahon C,Mahmud A,Feely J

    更新日期:2005-04-01 00:00:00

  • Validation of the A&D BP UA-651 device with a wide-range cuff for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    abstract::The aim of this study was to determine the accuracy of the A&D BP UA-651 device coupled to a wide-range cuff for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. The device was evaluated in 33 patients. The mean age of the patients was 56.5±15.1 year...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000100

    authors: Benetti E,Fania C,Palatini P

    更新日期:2015-06-01 00:00:00

  • Conventional and ambulatory measurements of blood pressure in old patients with isolated systolic hypertension: baseline observations in the Syst-Eur trial.

    abstract::OBJECTIVES: To compare clinic and am measurements of blood pressure in old patients with isolated systolic hypertension and their reproducibilities. PATIENTS: In total 610 patients aged >/= 60 years with isolated systolic hypertension detected by clinic measurement were monitored during the placebo run-in phase of the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Emelianov D,Thijs L,Staessen JA,Celis H,Clement D,Davidson C,Gasowski J,Gil-Extremera B,Fogari R,Jääskivi M,Lehtonen A,Nedogoda S,O'Brien E,Palatini P,Parati G,Salvetti A,Vanhanen H,Webster J,Fagard R

    更新日期:1998-06-01 00:00:00

  • Determination of accuracy in neonates for non-invasive blood pressure device using an improved algorithm.

    abstract:BACKGROUND:New software (SuperSTAT(R) algorithm) with enhancements aimed at shorter determination times was developed for a non-invasive blood pressure (NIBP) device and a clinical evaluation was conducted to verify accuracy. OBJECTIVE:To determine the accuracy of the new algorithm according to ANSI/AAMI SP10-1992 and...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200204000-00006

    authors: Nelson RM,Stebor AD,Groh CM,Timoney PM,Theobald KS,Friedman BA

    更新日期:2002-04-01 00:00:00

  • Which is the correct term for blood pressure measurements taken at home?

    abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200308000-00007

    authors: Stergiou GS

    更新日期:2003-08-01 00:00:00

  • Validation of TM-2655 oscillometric device for blood pressure measurement.

    abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000200484.49540.12

    authors: Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

    更新日期:2006-04-01 00:00:00

  • Does the accuracy of blood pressure measurement correlate with hearing loss of the observer?

    abstract:OBJECTIVE:The auscultatory method is influenced by the hearing level of the observers. If the observer has hearing loss, it is possible to measure blood pressure inaccurately by misreading the Korotkoff sounds at systolic blood pressure (SBP) and diastolic blood pressure (DBP). Because of the potential clinical problem...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000016

    authors: Song S,Lee J,Chee Y,Jang DP,Kim IY

    更新日期:2014-02-01 00:00:00

  • Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians.

    abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000130223.80658.3d

    authors: Staal EM,Nygård OK,Omvik P,Gerdts E

    更新日期:2004-06-01 00:00:00

  • The importance of the sympathetic nervous system and systolic hypertension in patients with hypertension: benefits in treating patients with increased cardiovascular risk.

    abstract::The sympathetic nervous system is intimately involved in both the origin and the perpetuation of the hypertensive state, although there is some debate as to its precise contribution to the long-term hypertensive condition. Catecholamines are leading candidates to be both the pressor mechanism that initiates the rise i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200010002-00005

    authors: Sica DA

    更新日期:2000-01-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • A short standardized protocol for measuring the QKD interval: comparison with 24 h monitoring and reproducibility.

    abstract::BACKGROUND: Ambulatory measurement for the QKD interval is a new method for evaluation of the rigidity of large arterial trunks. Reliable indices of arterial rigidity can be distilled from the large number of measurements (usually around 100) obtained during 24 h monitoring. OBJECTIVE: To describe a shorter standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Mas D,Gosse P,Julien V V,Jarnier P,Lemetayer P,Clementy J

    更新日期:1998-08-01 00:00:00

  • The effect of Ramadan fasting on ambulatory blood pressure in treated hypertensive patients using diuretics.

    abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000451

    authors: Aslan S,Riza Demir A,Kahraman S,Memiç K,Avci Y,Gürbak İ,Karabulut E,Ertürk M

    更新日期:2020-08-01 00:00:00

  • Endothelial dysfunction predicted increased left atrial volume index in newly diagnosed nondiabetic hypertensive patients.

    abstract:BACKGROUND:Arterial hypertension is associated with cardiovascular morbidity and mortality. It was previously shown that left atrium volume increase associated with mortality and atherosclerotic heart disease. The aim of the present study was to demonstrate the value of endothelial dysfunction in predicting left atrium...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000419

    authors: Çetin M,Erdoğan T,Kiriş T,Aykan AÇ,Çinier G,Emlek N,Durak H,Kalaycioğlu E,Yilmaz AS

    更新日期:2020-04-01 00:00:00

  • Characteristics of conventional blood pressure in studies on the predictive power of ambulatory blood pressure.

    abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析

    doi:10.1097/00126097-200202000-00006

    authors: Fagard RH,Staessen JA

    更新日期:2002-02-01 00:00:00

  • Oscillometric sphygmomanometers: a critical appraisal of current technology.

    abstract:AIM:Blood pressure (BP), a key vital sign, monitors general health. Oscillometric devices are increasingly used for measurement, although their accuracy continues to be critically debated. A functional block diagram is used to review the components that affect accuracy. METHODS:A block diagram is presented covering th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0b013e32835026b0

    authors: Amoore JN

    更新日期:2012-04-01 00:00:00

  • The impact of the day of the week on home blood pressure: the Finn-Home study.

    abstract:OBJECTIVE:The impact of the day of the week on home blood pressure (BP) level and day-to-day BP profile is unknown. Our objectives were to examine (i) how the initial measurement day of the week affects 3-day and 7-day mean home BP and (ii) the BP variation between different days of the week. PARTICIPANTS AND METHODS:...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000156

    authors: Juhanoja EP,Puukka PJ,Johansson JK,Niiranen TJ,Jula AM

    更新日期:2016-04-01 00:00:00