Blood pressure cuff comparability study.

Abstract:

BACKGROUND:Manufacturer-supplied blood pressure (BP) cuffs are part of the automatic oscillometric BP devices algorithm. MATERIALS AND METHODS:This study assessed the differences in BP values using the Omron HEM 907-XL (Omron) device with two types of cuffs: the Baum cuff (BC) and the supplied Omron cuff (OC). A sample of 102 adults participated in the study, 34 per cuff size (adult, large, and extra-large). After a 5-min resting period, three pairs of BP determinations (systolic and diastolic) were taken simultaneously on both arms. One arm was cuffed with a BC and the other arm was cuffed with an OC. The cuffs were switched to opposite arms after 5 min of rest. The order was decided randomly as to which cuff was applied to which arm first. RESULTS:The BP readings were highly correlated between the cuffs (systolic BP, r=0.98; diastolic BP, r=0.98). The overall mean differences (BC-OC) were 2.66 mmHg (SD=3.9 mmHg) for systolic BP (P<0.05) and 0.33 mmHg (SD=2.03 mmHg) for diastolic BP (P>0.05). Increased cuff size corresponded to increased differences in systolic BP values (adult: 1.51 mmHg; large: 2.56 mmHg; and extra-large: 3.9 mmHg; P<0.05). For diastolic BP values, a statistically significant difference was observed only for adult cuff size (difference=1.31 mmHg, SD=1.34 mmHg, P<0.05). CONCLUSION:Using a BC with the Omron could result in higher systolic BP readings and higher diastolic BP readings with the adult cuff size.

journal_name

Blood Press Monit

authors

Ostchega Y,Nwankwo T,Zhang G,Chiappa M

doi

10.1097/MBP.0000000000000208

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

345-351

issue

6

eissn

1359-5237

issn

1473-5725

journal_volume

21

pub_type

杂志文章,随机对照试验
  • Accuracy of oscillometric blood pressure algorithms in healthy adults and in adults with cardiovascular risk factors.

    abstract:BACKGROUND:Fixed-ratio and slope-based algorithms are used to derive oscillometric blood pressure (BP). However, a paucity of published data exists assessing the accuracy of these methods. Our objective was to determine the accuracy of fixed-ratio and slope-based algorithms in healthy adults and in adults with cardiova...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000356

    authors: Padwal R,Jalali A,McLean D,Anwar S,Smith K,Raggi P,Ringrose JS

    更新日期:2019-02-01 00:00:00

  • Masked hypertension, a review of the literature.

    abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/mbp.0b013e3280fb2792

    authors: Verberk WJ,Thien T,de Leeuw PW

    更新日期:2007-08-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Reliability of home blood pressure monitoring: in the context of validation and accuracy.

    abstract:OBJECTIVE:Home blood pressure (BP) monitoring offers clinically relevant information enriched with more abundant data. However, there are few studies addressing the reliability of home BP devices and the quality of its data. This study aimed to evaluate the current status of home BP devices in terms of validation and a...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000121

    authors: Jung MH,Kim GH,Kim JH,Moon KW,Yoo KD,Rho TH,Kim CM

    更新日期:2015-08-01 00:00:00

  • Assessment of antihypertensive efficacy by non-invasive ambulatory blood pressure monitoring.

    abstract::The session devoted to the usefulness of non-invasive ambulatory blood pressure monitoring (ABPM) in the evaluation of antihypertensive therapy allowed us to discuss a number of important issues. ABPM emerged as a widely accepted technique to measure blood pressure in clinical trials. Actually, it was generally consid...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Asmar R,Waeber B

    更新日期:1996-06-01 00:00:00

  • Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use.

    abstract:BACKGROUND:We have developed a new blood pressure (BP)-measuring device with a double-cuff, and evaluated its accuracy and applicability for practical use. DESIGN:The double-cuff method features a small cuff placed in the centre of the compression cuff to detect the oscillation of arterial pulsation, by which algorith...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00126097-200310000-00005

    authors: Tochikubo O,Nishijima K,Ohshige K,Kimura K

    更新日期:2003-10-01 00:00:00

  • Influence of multiple blood pressure measurements on the estimation of the ankle-brachial index and the consequent diagnosis of peripheral artery disease.

    abstract:OBJECTIVE:The ankle-brachial index (ABI) is the most useful and efficient tool for assessing the presence of peripheral artery disease (PAD). The aim of this study was to evaluate the effect of multiple sequential blood pressure (BP) measurements on the estimation of the ABI and the consequent diagnosis of PAD in a hig...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e328351de79

    authors: Real de Asúa D,Puchades R,García-Polo I,Suárez C

    更新日期:2012-04-01 00:00:00

  • Effects of the angiotensin II receptor blockers telmisartan versus valsartan in combination with hydrochlorothiazide: a large, confirmatory trial.

    abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e3282f3859d

    authors: White WB,Murwin D,Chrysant SG,Koval SE,Davidai G,Guthrie R

    更新日期:2008-02-01 00:00:00

  • Frequency domain of heart rate and blood pressure variability in essential hypertensive patients during sleep: differences between dippers and non-dippers.

    abstract::METHODS: Autonomic nervous function was evaluated by means of power spectral analysis of heart rate and blood pressure variability in dipper (n = 10) and non-dipper (n = 9) essential hypertensive subjects during sleep. The non-dipper subjects were defined as those in whom the nocturnal decrease in blood pressure was <...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Frisina N,Pedullà M,Mento G,Lanuzza B

    更新日期:1996-10-01 00:00:00

  • Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016.

    abstract:BACKGROUND:Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC). OBJECTIVE:To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems. PATIENTS...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000349

    authors: Ostchega Y,Hughes JP,Nwankwo T,Zhang G

    更新日期:2018-12-01 00:00:00

  • Validation protocols for blood pressure-measuring devices: status quo and development needs.

    abstract::Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000150

    authors: Beime B,Deutsch C,Gomez T,Zwingers T,Mengden T,Bramlage P

    更新日期:2016-02-01 00:00:00

  • Oscillometric sphygmomanometers: a critical appraisal of current technology.

    abstract:AIM:Blood pressure (BP), a key vital sign, monitors general health. Oscillometric devices are increasingly used for measurement, although their accuracy continues to be critically debated. A functional block diagram is used to review the components that affect accuracy. METHODS:A block diagram is presented covering th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0b013e32835026b0

    authors: Amoore JN

    更新日期:2012-04-01 00:00:00

  • Morning hypertension in chronic kidney disease is sustained type, but not surge type.

    abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32835026c6

    authors: Mizuno M,Fukuda M,Miura T,Wakamatsu T,Naito T,Sato R,Togawa H,Sasakawa Y,Tomonari T,Ono M,Kato Y,Ichikawa T,Shirasawa Y,Ito A,Yoshida A,Kimura G

    更新日期:2012-02-01 00:00:00

  • Automated office blood pressure - being alone and not location is what matters most.

    abstract:OBJECTIVE:Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impract...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000133

    authors: Armstrong D,Matangi M,Brouillard D,Myers MG

    更新日期:2015-08-01 00:00:00

  • Hidden errors of aneroid sphygmomanometers.

    abstract:BACKGROUND:Measurement of blood pressure remains the most commonly performed screening test in medical practice. With the likely removal of mercury sphygmomanometers from the workplace alternative devices are required. Of these the aneroid sphygmomanometer is popular both in the community and hospital setting. We inves...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200212000-00003

    authors: Waugh JJ,Gupta M,Rushbrook J,Halligan A,Shennan AH

    更新日期:2002-12-01 00:00:00

  • The choice of threshold limits for pediatric ambulatory blood pressure monitoring influences clinical decisions.

    abstract:OBJECTIVES:Hypertension in children may be defined by blood pressure elevated above the 95th percentile according to sex and age. Population data for ambulatory blood pressure provide different age-related and sex-related threshold limits to office-derived data. We sought to determine whether, when using ambulatory blo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209085.55364.73

    authors: Kennedy SE,Mackie FE,Craig E,Kainer G

    更新日期:2006-06-01 00:00:00

  • Blood pressure in acute ischemic stroke and mortality: a study with noninvasive blood pressure monitoring.

    abstract:BACKGROUND:In acute ischemic stroke, a transient elevation of blood pressure is common; its significance and its relationship with the neurological outcome are still unclear. METHODS:In 71 consecutive patients with acute ischemic stroke, aged 25-94 years, admitted to our unit, we investigated the relationships between...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209077.23084.93

    authors: Sartori M,Benetton V,Carraro AM,Calò LA,Macchini L,Giantin V,Tosato F,Pessina AC,Semplicini A

    更新日期:2006-08-01 00:00:00

  • Validation of TM-2655 oscillometric device for blood pressure measurement.

    abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000200484.49540.12

    authors: Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

    更新日期:2006-04-01 00:00:00

  • Endothelial dysfunction predicted increased left atrial volume index in newly diagnosed nondiabetic hypertensive patients.

    abstract:BACKGROUND:Arterial hypertension is associated with cardiovascular morbidity and mortality. It was previously shown that left atrium volume increase associated with mortality and atherosclerotic heart disease. The aim of the present study was to demonstrate the value of endothelial dysfunction in predicting left atrium...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000419

    authors: Çetin M,Erdoğan T,Kiriş T,Aykan AÇ,Çinier G,Emlek N,Durak H,Kalaycioğlu E,Yilmaz AS

    更新日期:2020-04-01 00:00:00

  • From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

    abstract::Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early...

    journal_title:Blood pressure monitoring

    pub_type: 传,历史文章,杂志文章

    doi:10.1097/MBP.0b013e3283380e1e

    authors: Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

    更新日期:2010-04-01 00:00:00

  • Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review.

    abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000344

    authors: Sprague E,Padwal RS

    更新日期:2018-10-01 00:00:00

  • The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    abstract:OBJECTIVE:To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. PARTICIPANTS AND METHODS:This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000141

    authors: Shangguan Q,Wu Y,Xu J,Su H,Li J,Hong K,Cheng X

    更新日期:2015-12-01 00:00:00

  • Effects of salt loading and potassium supplement on the circadian blood pressure profile in salt-sensitive Chinese patients.

    abstract:BACKGROUND AND OBJECTIVE:Salt-sensitive (SS) patients more frequently showed a nondipper blood pressure pattern and were associated with more serious target organ damage than non-SS patients. We aimed to investigate whether potassium supplement can improve the blunted nocturnal blood pressure fall in SS patients expose...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000276

    authors: Guo TS,Dai Y,Ren KY,Mu JJ,Ren J,Wang D,Wang Y,Chu C,Li Y,Yuan ZY

    更新日期:2017-12-01 00:00:00

  • Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards

    abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328330c873

    authors: Polo Friz H,Facchetti R,Primitz L,Beltrame L,Galbiati V,Ricioppo A,Bombelli M,Sega R

    更新日期:2009-10-01 00:00:00

  • High-intensity handgrip training lowers blood pressure and increases heart rate complexity among postmenopausal women: a pilot study.

    abstract:OBJECTIVE:Handgrip exercise is an emerging strategy for resting blood pressure (BP) reduction requiring minimal time and exercise effort. However, the research literature is currently limited to handgrip protocol designs predominantly prescribing sustained grip contractions, with little assessment of alternative option...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000313

    authors: Bentley DC,Nguyen CHP,Thomas SG

    更新日期:2018-04-01 00:00:00

  • A novel predictor of radial spasm: arterial stiffness.

    abstract:OBJECTIVE:In this study, we aimed to assess the relationship between radial artery spasm (RAS) and arterial stiffness (AS) measured by the oscillometric method. MATERIALS AND METHODS:A total of 123 consecutive patients scheduled for elective coronary angiography in a single default radial center were enrolled for the ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000340

    authors: Omaygenc MO,Karaca IO,Ibisoglu E,Günes HM,Kizilirmak F,Cakal B,Guler E,Barutcu I,Boztosun B

    更新日期:2018-10-01 00:00:00

  • Accuracy of the Microlife large-extra large-sized cuff (32-52 cm) coupled to an automatic oscillometric device.

    abstract::To determine the accuracy of the large-extra large-sized (L-XL) cuff (32-52 cm) coupled to a Microlife WatchBP Office ABI blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The L-XL cuff tested in this study is designed to provide...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328344c73c

    authors: Masiero S,Saladini F,Benetti E,Palatini P

    更新日期:2011-04-01 00:00:00

  • Clinical test of a blood pressure measurement device with a wrist cuff.

    abstract::OBJECTIVE: To test a semi-automatic oscillometric blood pressure measurement device with a wrist cuff. METHODS: Two different test methods, partly based on European and American standards for clinical investigation of non-invasive sphygmomanometers, were worked out and compared. Mostly German guidelines were considere...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Wonka F,Thümmler M,Schöppe A

    更新日期:1996-08-01 00:00:00

  • Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

    abstract::Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary cont...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Burnier M

    更新日期:2000-01-01 00:00:00

  • Validation of the A&D wrist-cuff UB-511 (UB-512) device for self-measurement of blood pressure.

    abstract:OBJECTIVES:To determine the accuracy of the A&D UB-511 (UB-512) oscillometric wrist-cuff device for self-measurement of blood pressure, the only difference between the two devices being the size of storage memory. METHODS:Device evaluation was performed according to the modified British Hypertension Society protocol r...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/01.mbp.0000217995.12215.f2

    authors: Angeli F,Sardone M,Angeli E,Repaci S,Gattobigio R,Verdecchia P

    更新日期:2006-12-01 00:00:00