Assessment of antihypertensive efficacy by non-invasive ambulatory blood pressure monitoring.

Abstract:

:The session devoted to the usefulness of non-invasive ambulatory blood pressure monitoring (ABPM) in the evaluation of antihypertensive therapy allowed us to discuss a number of important issues. ABPM emerged as a widely accepted technique to measure blood pressure in clinical trials. Actually, it was generally considered to provide more valuable information than do conventional blood pressure readings obtained sporadically by a doctor. However, still debated was the way of analysing ABPM recordings. This was particularly true with respect to the proposal of considering separately responders and non-responders when assessing the quality of blood pressure control achieved during treatment.

journal_name

Blood Press Monit

authors

Asmar R,Waeber B

subject

Has Abstract

pub_date

1996-06-01 00:00:00

pages

307

issue

3

eissn

1359-5237

issn

1473-5725

journal_volume

1

pub_type

杂志文章
  • Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards

    abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328330c873

    authors: Polo Friz H,Facchetti R,Primitz L,Beltrame L,Galbiati V,Ricioppo A,Bombelli M,Sega R

    更新日期:2009-10-01 00:00:00

  • Reliability of home blood pressure monitoring: in the context of validation and accuracy.

    abstract:OBJECTIVE:Home blood pressure (BP) monitoring offers clinically relevant information enriched with more abundant data. However, there are few studies addressing the reliability of home BP devices and the quality of its data. This study aimed to evaluate the current status of home BP devices in terms of validation and a...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000121

    authors: Jung MH,Kim GH,Kim JH,Moon KW,Yoo KD,Rho TH,Kim CM

    更新日期:2015-08-01 00:00:00

  • Relationship of vitamin D and parathyroid hormone with the nocturnal blood pressure decline in hypertension.

    abstract:OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated h...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000286

    authors: Karadag MK,Secen O

    更新日期:2017-12-01 00:00:00

  • Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review.

    abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000344

    authors: Sprague E,Padwal RS

    更新日期:2018-10-01 00:00:00

  • Which is the correct term for blood pressure measurements taken at home?

    abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200308000-00007

    authors: Stergiou GS

    更新日期:2003-08-01 00:00:00

  • 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?

    abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200110000-00005

    authors: Enström IE,Pennert KM

    更新日期:2001-10-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

    abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200502000-00005

    authors: Højgaard MV,Holstein-Rathlou NH,Agner E,Kanters JK

    更新日期:2005-02-01 00:00:00

  • Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect.

    abstract:OBJECTIVES:BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpT...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000189794.36230.a7

    authors: Culleton BF,McKay DW,Campbell NR

    更新日期:2006-02-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • A short standardized protocol for measuring the QKD interval: comparison with 24 h monitoring and reproducibility.

    abstract::BACKGROUND: Ambulatory measurement for the QKD interval is a new method for evaluation of the rigidity of large arterial trunks. Reliable indices of arterial rigidity can be distilled from the large number of measurements (usually around 100) obtained during 24 h monitoring. OBJECTIVE: To describe a shorter standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Mas D,Gosse P,Julien V V,Jarnier P,Lemetayer P,Clementy J

    更新日期:1998-08-01 00:00:00

  • Clinical features, anthropometric characteristics, and racial influences on the 'white-coat effect' in a single-centre cohort of 1553 consecutive subjects undergoing routine ambulatory blood pressure monitoring.

    abstract:BACKGROUND:Patients with high office blood pressures but relatively normal readings during daytime ambulatory monitoring have been the subject of much investigation and debate. This clinical finding in part depends on an alerting reaction to the circumstances of the clinical measurement, often described as the 'white-c...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Gualdiero P,Niebauer J,Addison C,Clark SJ,Coats AJ

    更新日期:2000-04-01 00:00:00

  • Rationale and design of HOMED-BP Study: hypertension objective treatment based on measurement by electrical devices of blood pressure study.

    abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00126097-200202000-00016

    authors: Fujiwara T,Nishimura T,Ohkuko T,Imai Y,HOMED-BP Study Group.

    更新日期:2002-02-01 00:00:00

  • The Maxi Stabil 3: validation of an aneroid device according to a modified British Hypertension Society protocol.

    abstract:BACKGROUND:Measuring blood pressure with mercury-independent alternatives is rapidly gaining attention. Mercury will be phased out of clinical use as a result of environmental, health and safety concerns and it is of vital importance that any alternative to mercury has to be of a recognized standard. We assessed the ac...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200304000-00005

    authors: Reinders A,Jones CR,Cuckson AC,Shennan AH

    更新日期:2003-04-01 00:00:00

  • Reduction of morning blood pressure surge after treatment with nifedipine GITS at bedtime, but not upon awakening, in essential hypertension.

    abstract:OBJECTIVES:The extent of morning blood pressure (BP) surge upon wakening has been associated with increased incidence of stroke and cardiovascular mortality. This trial investigated the antihypertensive efficacy and effects on the morning BP surge of awakening versus bedtime administration of nifedipine in essential hy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e32832e0d80

    authors: Hermida RC,Ayala DE,Mojón A,Alonso I,Fernández JR

    更新日期:2009-08-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Serum copeptin levels in predicting nondippers in newly diagnosed hypertension.

    abstract:OBJECTIVES:The nondipper pattern in hypertension is associated with worse cardiovascular outcomes. In this study, we hypothesized that high copeptin levels could predict nondippers among hypertensive patients and investigated the associations between copeptin levels and nondipper pattern in newly diagnosed hypertensive...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000123

    authors: Uzun F,Biyik I,Akturk IF,Yalcin AA,Erturk M,Oner E,Kalkan AK,Yalcin B,Atmaca H

    更新日期:2015-08-01 00:00:00

  • A novel predictor of radial spasm: arterial stiffness.

    abstract:OBJECTIVE:In this study, we aimed to assess the relationship between radial artery spasm (RAS) and arterial stiffness (AS) measured by the oscillometric method. MATERIALS AND METHODS:A total of 123 consecutive patients scheduled for elective coronary angiography in a single default radial center were enrolled for the ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000340

    authors: Omaygenc MO,Karaca IO,Ibisoglu E,Günes HM,Kizilirmak F,Cakal B,Guler E,Barutcu I,Boztosun B

    更新日期:2018-10-01 00:00:00

  • Clinical test of a blood pressure measurement device with a wrist cuff.

    abstract::OBJECTIVE: To test a semi-automatic oscillometric blood pressure measurement device with a wrist cuff. METHODS: Two different test methods, partly based on European and American standards for clinical investigation of non-invasive sphygmomanometers, were worked out and compared. Mostly German guidelines were considere...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Wonka F,Thümmler M,Schöppe A

    更新日期:1996-08-01 00:00:00

  • Prognostic value of average real variability of systolic blood pressure in elderly treated hypertensive patients.

    abstract:OBJECTIVE:The independent prognostic significance of ambulatory blood pressure variability in the elderly is incompletely clear. We investigated the prognostic value of average real variability of 24-hour blood pressure in elderly treated hypertensive patients. METHODS:The occurrence of a combined end-point including ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000381

    authors: Coccina F,Pierdomenico AM,Cuccurullo C,Pierdomenico SD

    更新日期:2019-08-01 00:00:00

  • Development of a simulator for the validation of noninvasive blood pressure-monitoring devices.

    abstract::This research aimed to develop a simulator capable of oscillometric pressure pulses recorded from the participants for the validation of oscillometric noninvasive blood pressure (NIBP) devices. The simulator generates the pressure pulses to the cuff connected to NIBP devices depending on the oscillometric waveforms ob...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000174

    authors: Doh I,Lim HK,Ahn B

    更新日期:2016-06-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

    abstract::Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary cont...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Burnier M

    更新日期:2000-01-01 00:00:00

  • The effect of Ramadan fasting on ambulatory blood pressure in treated hypertensive patients using diuretics.

    abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000451

    authors: Aslan S,Riza Demir A,Kahraman S,Memiç K,Avci Y,Gürbak İ,Karabulut E,Ertürk M

    更新日期:2020-08-01 00:00:00

  • The effects of renal denervation on resistant hypertension patients: a meta-analysis.

    abstract::We carried out this meta-analysis to assess the effects of renal denervation (RDN) on resistant hypertension patients. According to the collaborative review group search strategy, we searched MEDLINE (1996 to 2015.10); EBCO (1996 to 2015.10) and CNKI. A meta-analysis was carried out using RevMan 5.0. We identified 11 ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/MBP.0000000000000177

    authors: Zhang X,Wu N,Yan W,Zhou C,Guo H

    更新日期:2016-08-01 00:00:00

  • Effects of salt loading and potassium supplement on the circadian blood pressure profile in salt-sensitive Chinese patients.

    abstract:BACKGROUND AND OBJECTIVE:Salt-sensitive (SS) patients more frequently showed a nondipper blood pressure pattern and were associated with more serious target organ damage than non-SS patients. We aimed to investigate whether potassium supplement can improve the blunted nocturnal blood pressure fall in SS patients expose...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000276

    authors: Guo TS,Dai Y,Ren KY,Mu JJ,Ren J,Wang D,Wang Y,Chu C,Li Y,Yuan ZY

    更新日期:2017-12-01 00:00:00

  • An extended validation of the ScottCare 320 ambulatory blood pressure monitor: recommendations for clinical application.

    abstract:OBJECTIVES:The purpose of this study was to validate the ScottCare 320 ambulatory blood pressure monitor (ABPM) using both group-level and individual-level validation procedures. The group-level validation followed a modified protocol of the European Hypertension Society's validation protocol. The individual-level vali...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e32835f4fc7

    authors: Zawadzki MJ,Vandekar L,Smyth JM,Haas D,Gerin W

    更新日期:2013-06-01 00:00:00

  • Clinical use of ambulatory blood pressure monitoring in a Veteran's Medical Center.

    abstract::BACKGROUND: The lack of prospective data on the relative value of ambulatory blood pressure compared with office blood pressure as well as concern about increased costs have led to cautious endorsement of such monitoring in the clinical arena. Several consensus bodies have reviewed the scientific evidence and have sug...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Mansoor GA

    更新日期:1997-10-01 00:00:00

  • Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    abstract:OBJECTIVE:To evaluate the accuracy of the YuWell YE680B oscillometric upper-arm blood pressure monitor for clinic and home blood pressure measurements in adults according to the American National Standards Institute/the Association for the Advancement of Medical Instrumentation/International Organization for Standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000405

    authors: Huang JF,Zhang W,Li Y,Wang JG

    更新日期:2019-12-01 00:00:00

  • Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians.

    abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000130223.80658.3d

    authors: Staal EM,Nygård OK,Omvik P,Gerdts E

    更新日期:2004-06-01 00:00:00