Abstract:
:Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the morning and an additional two in the evening for at least 3 working days) have been suggested as the upper-normal reference limits. Unfortunately, these values have received limited support because only one study, the Ohasama study, examined the prognostic value of self-measured home blood pressure. For non-invasive 24 h ambulatory blood pressure, there are at least 11 reports of prospective outcome studies from independent centres that have examined the prognostic values of ambulatory blood pressure, but not all have attempted to define reference values. Currently, an average daytime blood pressure of less that 135 mmHg systolic and less than 85 mmHg diastolic is generally considered to be normal, and a level below 130/80 mmHg may be considered optimal. A reduction in blood pressure of less than 10% from day to night identifies subjects with an increased cardiovascular risk. There is some evidence that cardiovascular risk is further increased when night-time blood pressure is higher than daytime blood pressure. An average 24 h pulse pressure of over 53 mmHg identifies subjects with a raised cardiovascular risk.
journal_name
Blood Press Monitjournal_title
Blood pressure monitoringauthors
Verdecchia Pdoi
10.1097/00126097-200112000-00011subject
Has Abstractpub_date
2001-12-01 00:00:00pages
323-7issue
6eissn
1359-5237issn
1473-5725journal_volume
6pub_type
杂志文章,评审abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/00126097-200308000-00007
更新日期:2003-08-01 00:00:00
abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0b013e3282f3859d
更新日期:2008-02-01 00:00:00
abstract:BACKGROUND:Data on the reproducibility of serial measurements of ambulatory blood pressure in hypertensive patients are lacking. The purpose of this study was to examine (1) the reproducibility of four consecutive ambulatory blood pressure measurements, and (2) the reproducibility of nocturnal falls in blood pressure i...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200102000-00007
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328346d715
更新日期:2011-08-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to validate the ScottCare 320 ambulatory blood pressure monitor (ABPM) using both group-level and individual-level validation procedures. The group-level validation followed a modified protocol of the European Hypertension Society's validation protocol. The individual-level vali...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0b013e32835f4fc7
更新日期:2013-06-01 00:00:00
abstract::Some oscillometric non-invasive blood pressure (NIBP) monitors use twin-hose cuffs, whereas others use single-hose cuffs. The incompatibility hinders the transfer of patients from monitors using a single-hose cuff to monitors using twin-hose cuffs and vice versa. In particular, the Propaq Encore uses a single-hose cuf...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00
abstract::Ambulatory blood pressure monitoring (ABPM) has become more widely used in the assessment of elevated blood pressure in children. The accurate diagnosis of white coat hypertension (WCH) is particularly important in children because detection of elevated blood pressure often results in expensive and invasive diagnostic...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/00126097-200008000-00001
更新日期:2000-08-01 00:00:00
abstract::OBJECTIVES: To compare clinic and am measurements of blood pressure in old patients with isolated systolic hypertension and their reproducibilities. PATIENTS: In total 610 patients aged >/= 60 years with isolated systolic hypertension detected by clinic measurement were monitored during the placebo run-in phase of the...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract:BACKGROUND:New software (SuperSTAT(R) algorithm) with enhancements aimed at shorter determination times was developed for a non-invasive blood pressure (NIBP) device and a clinical evaluation was conducted to verify accuracy. OBJECTIVE:To determine the accuracy of the new algorithm according to ANSI/AAMI SP10-1992 and...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200204000-00006
更新日期:2002-04-01 00:00:00
abstract::BACKGROUND: Blood pressure measurements taken in the clinic or laboratory are assumed to generalize to the world outside. This is true both of casual blood pressure measurements and of changes in blood pressure responses to stress. Such generalizability is crucial to the usefulness of blood pressure measurements as pr...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-12-01 00:00:00
abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/MBP.0000000000000230
更新日期:2017-04-01 00:00:00
abstract:OBJECTIVE:The ankle-brachial index (ABI) is the most useful and efficient tool for assessing the presence of peripheral artery disease (PAD). The aim of this study was to evaluate the effect of multiple sequential blood pressure (BP) measurements on the estimation of the ABI and the consequent diagnosis of PAD in a hig...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0b013e328351de79
更新日期:2012-04-01 00:00:00
abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3280b083a7
更新日期:2007-06-01 00:00:00
abstract:OBJECTIVES:Hypertension in children may be defined by blood pressure elevated above the 95th percentile according to sex and age. Population data for ambulatory blood pressure provide different age-related and sex-related threshold limits to office-derived data. We sought to determine whether, when using ambulatory blo...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/01.mbp.0000209085.55364.73
更新日期:2006-06-01 00:00:00
abstract:BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of thi...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000319
更新日期:2018-06-01 00:00:00
abstract:OBJECTIVE:To compare readings obtained using two automated blood pressure (BP) recording devices, BpTRU and Omron 907, in a clinical setting. METHODS:Two series of 50 patients attending a hypertension unit for 24-h ambulatory BP monitoring had BP recorded either every 1 or every 2 min using BpTRU and Omron 907 devices...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e32831e314f
更新日期:2009-02-01 00:00:00
abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200106000-00008
更新日期:2001-06-01 00:00:00
abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/01.mbp.0000130223.80658.3d
更新日期:2004-06-01 00:00:00
abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328346a871
更新日期:2011-06-01 00:00:00
abstract::We performed this study to elucidate the role of nighttime versus daytime ambulatory blood pressure in predicting stroke and cardiac events. The International Collaborative Study of the Prognostic Utility of ABPM, which includes prospective cohort studies of ambulatory blood pressure monitoring (ABPM) from seven sites...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,多中心研究
doi:10.1097/MBP.0b013e3282411a12
更新日期:2007-12-01 00:00:00
abstract:OBJECTIVE:To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. PARTICIPANTS AND METHODS:This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000141
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVES:In young and middle age, women have higher orthostatic intolerance (OI) than men, and hemodynamic differences have been found supporting this finding. In older people, these sex differences are less studied. Our aim was to contribute evidence. METHODS:Two hundred and twenty-four community-dwelling older par...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3283353199
更新日期:2010-02-01 00:00:00
abstract:OBJECTIVE:To compare the effects of a high-fidelity simulator and conventional teaching model used during blood pressure measurement training on students' self-confidence, self-efficacy and anxiety levels. METHODS:A randomized controlled trial design was used. The study was conducted on 59 first-year nursing students ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0000000000000401
更新日期:2019-12-01 00:00:00
abstract:OBJECTIVE:Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS:We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mann...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3282fd16e3
更新日期:2008-06-01 00:00:00
abstract:BACKGROUND:Measurement of blood pressure remains the most commonly performed screening test in medical practice. With the likely removal of mercury sphygmomanometers from the workplace alternative devices are required. Of these the aneroid sphygmomanometer is popular both in the community and hospital setting. We inves...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200212000-00003
更新日期:2002-12-01 00:00:00
abstract:OBJECTIVE:Psoriasis is a chronic inflammatory disorder, which is associated with high risk of metabolic comorbidities. Hypertension (HTN) is among the most common and serious associations. In this study, we aimed to evaluate HTN in psoriatic patients through office and ambulatory blood pressure monitoring (ABPM). MATE...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000489
更新日期:2020-12-01 00:00:00
abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000053
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200110000-00005
更新日期:2001-10-01 00:00:00
abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200306000-00006
更新日期:2003-06-01 00:00:00
abstract::BACKGROUND: Hypertension is responsible for substantial morbidity in end-stage renal disease. Ambulatory blood pressure monitoring has been used to understand the behavior of blood pressure in renal failure, especially during the interdialytic period for patients on hemodialysis. OBJECTIVE: To review the published dat...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00