Comparison of two automated sphygmomanometers for use in the office setting.

Abstract:

OBJECTIVE:To compare readings obtained using two automated blood pressure (BP) recording devices, BpTRU and Omron 907, in a clinical setting. METHODS:Two series of 50 patients attending a hypertension unit for 24-h ambulatory BP monitoring had BP recorded either every 1 or every 2 min using BpTRU and Omron 907 devices with the order of the measurements being randomized. RESULTS:No significant differences for systolic BP between the mean readings taken using the BpTRU or Omron 907 recorders at either 1 or 2 min were observed. Diastolic BP readings were similar using the 1-min interval setting but were 5.0 mmHg lower for the Omron 907 (P<0.001) when readings were taken at 2-min intervals. CONCLUSION:BP measurements can be made in the clinical setting using either the BpTRU or Omron 907 automated sphygmomanometers.

journal_name

Blood Press Monit

authors

Myers MG,Valdivieso M,Kiss A,Tobe SW

doi

10.1097/MBP.0b013e32831e314f

subject

Has Abstract

pub_date

2009-02-01 00:00:00

pages

45-7

issue

1

eissn

1359-5237

issn

1473-5725

journal_volume

14

pub_type

杂志文章
  • Differential effects of antihypertensive drugs on circadian rhythm in blood pressure from the chronobiological point of view.

    abstract::REVIEW IN DEPTH: The cardiovascular system is well organized in time. The blood pressure normally displays a circadian rhythm characterized by a nightly drop which, however, can be disturbed by disease. The 24 h blood pressure and its mechanisms of regulation are very dynamic and rhythmic processes. Ambulatory blood p...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Lemmer B

    更新日期:1996-04-01 00:00:00

  • Prevalence and determinants of masked hypertension among obese individuals at the Yaoundé Central Hospital: a cross-sectional study in sub-Saharan Africa.

    abstract:OBJECTIVES:The aim of this study was to investigate the prevalence and associated factors of masked hypertension in obese patients in Yaounde. METHODS:We carried out a cross-sectional study from January to September 2017 at the National Obesity Center of the Yaounde Central Hospital. Masked hypertension was defined wh...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000457

    authors: Hamadou B,Amougou SN,Tchuendem Y,Nganou-Gnindjio CN,Mfeukeu-Kuate L,Foka AJ,Tankeu AT,Jingi AM,Menanga AP,Kingue S

    更新日期:2020-08-01 00:00:00

  • Characteristics of conventional blood pressure in studies on the predictive power of ambulatory blood pressure.

    abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析

    doi:10.1097/00126097-200202000-00006

    authors: Fagard RH,Staessen JA

    更新日期:2002-02-01 00:00:00

  • Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect.

    abstract:OBJECTIVES:BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpT...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000189794.36230.a7

    authors: Culleton BF,McKay DW,Campbell NR

    更新日期:2006-02-01 00:00:00

  • A novel predictor of radial spasm: arterial stiffness.

    abstract:OBJECTIVE:In this study, we aimed to assess the relationship between radial artery spasm (RAS) and arterial stiffness (AS) measured by the oscillometric method. MATERIALS AND METHODS:A total of 123 consecutive patients scheduled for elective coronary angiography in a single default radial center were enrolled for the ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000340

    authors: Omaygenc MO,Karaca IO,Ibisoglu E,Günes HM,Kizilirmak F,Cakal B,Guler E,Barutcu I,Boztosun B

    更新日期:2018-10-01 00:00:00

  • Blood pressure monitoring in sleep: time to wake up.

    abstract::Hypertension is a highly common condition with well-established adverse consequences. Ambulatory blood pressure monitoring has repeatedly been shown to better predict cardiovascular outcomes and mortality, compared to single office visit blood pressure. Non-dipping of sleep-time blood pressure is an independent marker...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000426

    authors: Kwon Y,Stafford PL,Lim DC,Park S,Kim SH,Berry RB,Calhoun DA

    更新日期:2020-04-01 00:00:00

  • High-intensity handgrip training lowers blood pressure and increases heart rate complexity among postmenopausal women: a pilot study.

    abstract:OBJECTIVE:Handgrip exercise is an emerging strategy for resting blood pressure (BP) reduction requiring minimal time and exercise effort. However, the research literature is currently limited to handgrip protocol designs predominantly prescribing sustained grip contractions, with little assessment of alternative option...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000313

    authors: Bentley DC,Nguyen CHP,Thomas SG

    更新日期:2018-04-01 00:00:00

  • Reproducibility of ambulatory blood pressure measurements in essential hypertension.

    abstract:BACKGROUND:Data on the reproducibility of serial measurements of ambulatory blood pressure in hypertensive patients are lacking. The purpose of this study was to examine (1) the reproducibility of four consecutive ambulatory blood pressure measurements, and (2) the reproducibility of nocturnal falls in blood pressure i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200102000-00007

    authors: Zakopoulos NA,Nanas SN,Lekakis JP,Vemmos KN,Kotsis VT,Pitiriga VC,Stamatelopoulos SF,Moulopoulos SD

    更新日期:2001-02-01 00:00:00

  • Does the mean 24-h pulse rate from ambulatory blood pressure monitoring reflect the mean 24-h ventricular rate from Holter electrocardiogram in atrial fibrillation patients?

    abstract:BACKGROUND:Ambulatory blood pressure monitoring (ABPM) on the oscillometric method is applicable in patients with atrial fibrillation, but the mean pulse rate is or not similar to the ventricular rate from the Holter in atrial fibrillation patients remains unknown. METHODS:This study included 228 persistent atrial fib...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000481

    authors: Tong HY,Yu JH,Hong K,Chen J,Liu HY,Su H

    更新日期:2020-12-01 00:00:00

  • 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?

    abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200110000-00005

    authors: Enström IE,Pennert KM

    更新日期:2001-10-01 00:00:00

  • A short standardized protocol for measuring the QKD interval: comparison with 24 h monitoring and reproducibility.

    abstract::BACKGROUND: Ambulatory measurement for the QKD interval is a new method for evaluation of the rigidity of large arterial trunks. Reliable indices of arterial rigidity can be distilled from the large number of measurements (usually around 100) obtained during 24 h monitoring. OBJECTIVE: To describe a shorter standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Mas D,Gosse P,Julien V V,Jarnier P,Lemetayer P,Clementy J

    更新日期:1998-08-01 00:00:00

  • Ambulatory blood pressure variation in normotensive subjects in relation to the sitting or standing position.

    abstract:OBJECTIVE:To evaluate the physiological variations in arterial blood pressure in normotensive subjects during activity and in relation to the sitting or lying position. METHODS:The subjects were 30 healthy volunteers who were normotensive and receiving no treatment. Blood pressure was measured using the validated moni...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200006000-00005

    authors: Mallion JM,Mouret S,Baguet JP,Maître A,Quesada JL,De Gaudemaris R

    更新日期:2000-06-01 00:00:00

  • Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review.

    abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000344

    authors: Sprague E,Padwal RS

    更新日期:2018-10-01 00:00:00

  • Ambulatory blood pressure variability: a conceptual review.

    abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000230

    authors: Zawadzki MJ,Small AK,Gerin W

    更新日期:2017-04-01 00:00:00

  • Angiotensin II receptor blockers following intravenous nicardipine administration to lower blood pressure in patients with hypertensive intracerebral hemorrhage: a prospective randomized study.

    abstract:BACKGROUND AND OBJECTIVE:In patients with hypertensive intracerebral hemorrhage (HICH), intravenous nicardipine is primarily used to lower blood pressure (BP). However, there are few studies investigating the role of oral antihypertensives administered after intravenous nicardipine to prevent BP from rising. Angiotensi...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000225

    authors: Inamasu J,Nakae S,Adachi K,Hirose Y

    更新日期:2017-02-01 00:00:00

  • Blood pressure control in anticoagulated hypertensive patients.

    abstract:OBJECTIVE:To compare the methods of office blood pressure (BP) measurement and ambulatory blood pressure monitoring (ABPM) to ensure optimal BP control in hypertensive anticoagulated patients. PATIENTS AND METHODS:Seventy-eight patients who were receiving antihypertensive drugs and warfarin in a dose-adjusted approach...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000084

    authors: Guzet F,Bitigen A,Karabay CY,Cimen AO,Teyfik N

    更新日期:2015-02-01 00:00:00

  • Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT.

    abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200306000-00006

    authors: El Assaad MA,Topouchian JA,Asmar RG

    更新日期:2003-06-01 00:00:00

  • Cardiovascular triggers and morning events.

    abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Chasen C,Muller JE

    更新日期:1998-02-01 00:00:00

  • Rationale and design of HOMED-BP Study: hypertension objective treatment based on measurement by electrical devices of blood pressure study.

    abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00126097-200202000-00016

    authors: Fujiwara T,Nishimura T,Ohkuko T,Imai Y,HOMED-BP Study Group.

    更新日期:2002-02-01 00:00:00

  • Use of feedback on medium-term blood pressure measurement skills in medical students: a randomized controlled trial.

    abstract:BACKGROUND:The objective of this study was to assess the effect of feedback on medium-term blood pressure (BP) measurement skills in medical students versus a control group. METHODS:A randomized controlled trial in first-year medical students was conducted. After theoretical-practical training on measuring BP, the stu...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000433

    authors: Bastos E Castro MA,Lucchetti ALG,Tibiriçá SHC,da Silva Ezequiel O,Lucchetti G

    更新日期:2020-06-01 00:00:00

  • Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use.

    abstract:BACKGROUND:We have developed a new blood pressure (BP)-measuring device with a double-cuff, and evaluated its accuracy and applicability for practical use. DESIGN:The double-cuff method features a small cuff placed in the centre of the compression cuff to detect the oscillation of arterial pulsation, by which algorith...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00126097-200310000-00005

    authors: Tochikubo O,Nishijima K,Ohshige K,Kimura K

    更新日期:2003-10-01 00:00:00

  • The importance of the sympathetic nervous system and systolic hypertension in patients with hypertension: benefits in treating patients with increased cardiovascular risk.

    abstract::The sympathetic nervous system is intimately involved in both the origin and the perpetuation of the hypertensive state, although there is some debate as to its precise contribution to the long-term hypertensive condition. Catecholamines are leading candidates to be both the pressor mechanism that initiates the rise i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200010002-00005

    authors: Sica DA

    更新日期:2000-01-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • Reduction of morning blood pressure surge after treatment with nifedipine GITS at bedtime, but not upon awakening, in essential hypertension.

    abstract:OBJECTIVES:The extent of morning blood pressure (BP) surge upon wakening has been associated with increased incidence of stroke and cardiovascular mortality. This trial investigated the antihypertensive efficacy and effects on the morning BP surge of awakening versus bedtime administration of nifedipine in essential hy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e32832e0d80

    authors: Hermida RC,Ayala DE,Mojón A,Alonso I,Fernández JR

    更新日期:2009-08-01 00:00:00

  • Prognostic significance of self-measurements of blood pressure.

    abstract:BACKGROUND:Self-measurements of blood pressure may offer some advantage in diagnostic and therapeutic evaluation and in management of patients. However, the most important limitation of self-measurement is that there are limited data available about the prognostic value of this information. RESULTS:Authors of several ...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Imai Y,Poncelet P,DeBuyzere M,Padfield PL,Van Montfrans GA

    更新日期:2000-04-01 00:00:00

  • Effect of fasting on 24-h blood pressure values of individuals with no previous history of hypertension.

    abstract:OBJECTIVE:We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. PATIENTS AND METHODS:This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage chang...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0000000000000244

    authors: Seker A,Demirci H,Ocakoglu G,Aydin U,Ucar H,Yildiz G,Yaman O

    更新日期:2017-10-01 00:00:00

  • Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards

    abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328330c873

    authors: Polo Friz H,Facchetti R,Primitz L,Beltrame L,Galbiati V,Ricioppo A,Bombelli M,Sega R

    更新日期:2009-10-01 00:00:00

  • Validation of the Omron HEM-907 device for blood pressure measurement.

    abstract:BACKGROUND:The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. DESIGN:The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200208000-00006

    authors: El Assaad MA,Topouchian JA,Darné BM,Asmar RG

    更新日期:2002-08-01 00:00:00

  • Determination of accuracies of 10 models of home blood pressure monitors using an oscillometric simulator.

    abstract:BACKGROUND:Patients and doctors often use home blood pressure monitoring (HBPM) to assess the control of hypertension. Despite its popularity there has always been some uncertainty with regard to its accuracy, reliability, reproducibility, and comparability. Although there are pre-market HBPM standards of accuracy, the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-199904010-00007

    authors: Yarows SA,Amerena JV

    更新日期:1999-02-01 00:00:00

  • A psychophysiologic reaction to application of ambulatory blood pressure monitor: fact or artifact?

    abstract:BACKGROUND:The study investigated the clinical significance of relatively high blood pressure (BP) elevations during the calibration of the ambulatory blood pressure monitor (ABPM). METHODS:Inferences were drawn from the analysis of differences between 'M', the average of five manually triggered responses, and 'W', th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328340ff51

    authors: Yanovski A,Townsend RR,Virginia F,Michael C

    更新日期:2011-02-01 00:00:00