Abstract:
BACKGROUND:Patients and doctors often use home blood pressure monitoring (HBPM) to assess the control of hypertension. Despite its popularity there has always been some uncertainty with regard to its accuracy, reliability, reproducibility, and comparability. Although there are pre-market HBPM standards of accuracy, there are no standards to assure accuracy of individual HBPM units after they have been brought home. OBJECTIVE:Determination of reliability, reproducibility, and comparability of 10 models of home blood pressure monitors. METHODS:We used a Biotek BP Pump as an oscillometric simulator of systolic and diastolic blood pressures to determine reliability, reproducibility, and comparability of 10 devices. RESULTS:All of the units tested, except the Pollonex BP1000, produced reproducible readings with the pooled SD of four blood pressure settings less than 3.10 mmHg both for systolic and for diastolic measurements. The oscillometric blood pressure pump method was found to be very reproducible, with pooled differences of less than 2 mmHg and SD of less than 0.5 mmHg for a repeated series of measurements using the same monitor. Different machines of the same model were also very comparable, with pooled differences of less than 3.6 mmHg and pooled SD less than 0.7 mmHg both for systolic and for diastolic readings. There were 11-14 mmHg differences between models for all of the simulated blood pressure readings except that a 27 mmHg difference was measured at the 200 mmHg systolic blood pressure level. These differences will not necessarily be the same for measurements with humans instead of oscillometric signal generation. A system for grading the accuracy of the tested HBPM that defines accuracy of HBPM as within +/-2 SD of the average of 85 measurements is described. CONCLUSION:All models of home blood pressure monitors tested, with the exceptions of the Pollonex BP1000, produced reproducible readings and different machines of the same model were comparable.
journal_name
Blood Press Monitjournal_title
Blood pressure monitoringauthors
Yarows SA,Amerena JVdoi
10.1097/00126097-199904010-00007subject
Has Abstractpub_date
1999-02-01 00:00:00pages
45-52issue
1eissn
1359-5237issn
1473-5725journal_volume
4pub_type
杂志文章abstract:OBJECTIVES:The aim of this study was to investigate the prevalence and associated factors of masked hypertension in obese patients in Yaounde. METHODS:We carried out a cross-sectional study from January to September 2017 at the National Obesity Center of the Yaounde Central Hospital. Masked hypertension was defined wh...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000457
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVE:To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. PARTICIPANTS AND METHODS:This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000141
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVE:Pulse wave velocity (PWV) is a measure of arterial stiffness and a marker for cardiovascular disease. Although commonly used, there are only a few reports investigating the intersession and intrasession variability in PWV measurements, the determination of which is important in a mixed population when using P...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000052
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e32834b4431
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND:Patients with high office blood pressures but relatively normal readings during daytime ambulatory monitoring have been the subject of much investigation and debate. This clinical finding in part depends on an alerting reaction to the circumstances of the clinical measurement, often described as the 'white-c...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:2000-04-01 00:00:00
abstract:BACKGROUND:Waist circumference (WC) and related anthropometric indices have been recognized as useful measures of abdominal obesity. However, little is known about the association of waist-to-sitting-height ratio (WSHtR) with obesity and elevated blood pressure (BP). PARTICIPANTS AND METHODS:Data for this study were o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000154
更新日期:2016-02-01 00:00:00
abstract::Hypertension is highly prevalent in pediatric patients with end-stage renal disease (ESRD). Ambulatory blood pressure monitoring (ABPM) has been used to characterize the altered circadian blood pressure patterns in ESRD in order to improve our understanding of the blood pressure dysregulation that occurs in these chil...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:
更新日期:1999-06-01 00:00:00
abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000053
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:Blood pressure measurements during exercise are difficult to obtain but are used widely in clinical practice. The objective of this study was to investigate the repeatability of blood pressure measurements and gas exchange parameters during treadmill exercise. METHODS:Participants were 10 healthy and nonsmok...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0b013e328351de5c
更新日期:2012-04-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to test whether the auscultatory method and Finapres provide similar readings for blood pressure response during two resistance exercise protocols of different intensities, and to gain some insight into whether auscultation can be used to monitor cardiovascular stress during r...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e32809ef9f1
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3280b083a7
更新日期:2007-06-01 00:00:00
abstract::The aim of this study was to determine the accuracy of the A&D BP UA-651 device coupled to a wide-range cuff for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. The device was evaluated in 33 patients. The mean age of the patients was 56.5±15.1 year...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000100
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND:Ambulatory blood pressure monitoring allows characterization of the patient's average blood pressure load as well as various profiles of blood pressure. Results from clinical studies suggest that dippers (patients whose blood pressures decrease during night-time) have a lower risk of cardiovascular events th...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200002000-00004
更新日期:2000-02-01 00:00:00
abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200306000-00006
更新日期:2003-06-01 00:00:00
abstract:OBJECTIVES:To determine the accuracy of the A&D UB-511 (UB-512) oscillometric wrist-cuff device for self-measurement of blood pressure, the only difference between the two devices being the size of storage memory. METHODS:Device evaluation was performed according to the modified British Hypertension Society protocol r...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/01.mbp.0000217995.12215.f2
更新日期:2006-12-01 00:00:00
abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00126097-200202000-00016
更新日期:2002-02-01 00:00:00
abstract:BACKGROUND:Fixed-ratio and slope-based algorithms are used to derive oscillometric blood pressure (BP). However, a paucity of published data exists assessing the accuracy of these methods. Our objective was to determine the accuracy of fixed-ratio and slope-based algorithms in healthy adults and in adults with cardiova...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000356
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVE:Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impract...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000133
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/01.mbp.0000200484.49540.12
更新日期:2006-04-01 00:00:00
abstract:BACKGROUND:The objective of this study was to assess the effect of feedback on medium-term blood pressure (BP) measurement skills in medical students versus a control group. METHODS:A randomized controlled trial in first-year medical students was conducted. After theoretical-practical training on measuring BP, the stu...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0000000000000433
更新日期:2020-06-01 00:00:00
abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0b013e3282f3859d
更新日期:2008-02-01 00:00:00
abstract:OBJECTIVES:In young and middle age, women have higher orthostatic intolerance (OI) than men, and hemodynamic differences have been found supporting this finding. In older people, these sex differences are less studied. Our aim was to contribute evidence. METHODS:Two hundred and twenty-four community-dwelling older par...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3283353199
更新日期:2010-02-01 00:00:00
abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/mbp.0b013e3280fb2792
更新日期:2007-08-01 00:00:00
abstract:OBJECTIVES:To determine blood pressure (BP) reassessment rates and to describe the evaluation and outpatient referral rates of elderly emergency department (ED) patients with elevated BP. METHODS:This was a retrospective cohort of patients who were at least 60 years, presented with a systolic BP of at least 140 mmHg o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,多中心研究
doi:10.1097/MBP.0b013e328332fd40
更新日期:2009-12-01 00:00:00
abstract::We performed this study to elucidate the role of nighttime versus daytime ambulatory blood pressure in predicting stroke and cardiac events. The International Collaborative Study of the Prognostic Utility of ABPM, which includes prospective cohort studies of ambulatory blood pressure monitoring (ABPM) from seven sites...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,多中心研究
doi:10.1097/MBP.0b013e3282411a12
更新日期:2007-12-01 00:00:00
abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200106000-00008
更新日期:2001-06-01 00:00:00
abstract:BACKGROUND:We have developed a new blood pressure (BP)-measuring device with a double-cuff, and evaluated its accuracy and applicability for practical use. DESIGN:The double-cuff method features a small cuff placed in the centre of the compression cuff to detect the oscillation of arterial pulsation, by which algorith...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/00126097-200310000-00005
更新日期:2003-10-01 00:00:00
abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000451
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328346d715
更新日期:2011-08-01 00:00:00
abstract:OBJECTIVE:To compare readings obtained using two automated blood pressure (BP) recording devices, BpTRU and Omron 907, in a clinical setting. METHODS:Two series of 50 patients attending a hypertension unit for 24-h ambulatory BP monitoring had BP recorded either every 1 or every 2 min using BpTRU and Omron 907 devices...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e32831e314f
更新日期:2009-02-01 00:00:00