Aortic systolic pressure derived with different calibration methods: associations to brachial systolic pressure in the general population.

Abstract:

BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of this study was to investigate associations between different methods of systolic pressure assessment in a large cohort and its comparison with recently published evidence. PARTICIPANTS AND METHODS:During a public health campaign, cardiovascular hemodynamic data were assessed using a validated oscillometric device in a pharmacy setting. The device measures bSBP, mean arterial pressure, and diastolic blood pressure (DBP), and records brachial waveforms at the DBP level. aSBP1 was derived using bSBP and DBP and aSBP2 using measured mean arterial pressure and DBP for waveform calibration. In addition to pressures, age, sex, and anthropometric data were recorded. Regression analysis was carried out to investigate associations. RESULTS:A total of 7409 (5133/2276, female/male) individuals with a median age of 54 years were sampled. aSBPs differed significantly from bSBP (126.0 mmHg) for aSBP1 (117.0 mmHg) and aSBP2 (127.5 mmHg, both P<0.0001). Regression analysis showed that aSBP2 (R=0.853) is significantly less associated with bSBP than aSBP1 (R=0.937) (Williams' test, P<0.001 for comparison). Subgroup analysis showed the major influence of sex and heart rate. The association between bSBP, aSBP1 (R=0.83), and aSBP2 (R=0.66), respectively, reduced significantly for borderline hypertensives (P<0.001 for comparison). CONCLUSION:In contrast to aSBP1, the association between bSBP and aSBP2 is significantly less dominant and therefore aSBP2 may have potential prognostic superiority over bSBP.

journal_name

Blood Press Monit

authors

Wassertheurer S,Hametner B,Mayer CC,Hafez A,Negishi K,Papaioannou TG,Protogerou AD,Sharman JE,Weber T

doi

10.1097/MBP.0000000000000319

subject

Has Abstract

pub_date

2018-06-01 00:00:00

pages

134-140

issue

3

eissn

1359-5237

issn

1473-5725

journal_volume

23

pub_type

临床试验,杂志文章
  • Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing.

    abstract:OBJECTIVE:The Welch Allyn Pro BP 2000, an automated sphygmomanometer, was subjected to ANSI/AAMI/ISO testing. PATIENTS AND METHODS:The protocol used was the same-arm sequential procedure described in the ANSI/AAMI/ISO 2013 Standard. Eight-eight (53 adults and 35 children aged 3-12 years old) patients completed testing...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000350

    authors: Alpert BS

    更新日期:2018-12-01 00:00:00

  • Influence of multiple blood pressure measurements on the estimation of the ankle-brachial index and the consequent diagnosis of peripheral artery disease.

    abstract:OBJECTIVE:The ankle-brachial index (ABI) is the most useful and efficient tool for assessing the presence of peripheral artery disease (PAD). The aim of this study was to evaluate the effect of multiple sequential blood pressure (BP) measurements on the estimation of the ABI and the consequent diagnosis of PAD in a hig...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e328351de79

    authors: Real de Asúa D,Puchades R,García-Polo I,Suárez C

    更新日期:2012-04-01 00:00:00

  • Effects of the angiotensin II receptor blockers telmisartan versus valsartan in combination with hydrochlorothiazide: a large, confirmatory trial.

    abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e3282f3859d

    authors: White WB,Murwin D,Chrysant SG,Koval SE,Davidai G,Guthrie R

    更新日期:2008-02-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • Validation of the Omron HEM-907 device for blood pressure measurement.

    abstract:BACKGROUND:The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. DESIGN:The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200208000-00006

    authors: El Assaad MA,Topouchian JA,Darné BM,Asmar RG

    更新日期:2002-08-01 00:00:00

  • The effect of crossing legs on blood pressure.

    abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3280b083a7

    authors: Adiyaman A,Tosun N,Elving LD,Deinum J,Lenders JW,Thien T

    更新日期:2007-06-01 00:00:00

  • Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346d715

    authors: Yi J,Wan Y,Pan F,Yu X,Zhao H,Shang F,Xu Y

    更新日期:2011-08-01 00:00:00

  • Effect of bedtime melatonin ingestion on blood pressure of normotensive subjects.

    abstract::OBJECTIVE: To determine whether the evening intake of 5 mg melatonin affects 24 h arterial blood pressure and heart-rate profiles. METHODS: Twenty-one young normotensive subjects were administered placebo or melatonin for 4 weeks, according to a cross-over double-blind design, and were subjected to ambulatory blood pr...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Lusardi P,Preti P,Savino S,Piazza E,Zoppi A,Fogari R

    更新日期:1997-04-01 00:00:00

  • The effect of Ramadan fasting on ambulatory blood pressure in treated hypertensive patients using diuretics.

    abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000451

    authors: Aslan S,Riza Demir A,Kahraman S,Memiç K,Avci Y,Gürbak İ,Karabulut E,Ertürk M

    更新日期:2020-08-01 00:00:00

  • Comparison of the effects of two different teaching methods in blood pressure measurement training: a randomized controlled study.

    abstract:OBJECTIVE:To compare the effects of a high-fidelity simulator and conventional teaching model used during blood pressure measurement training on students' self-confidence, self-efficacy and anxiety levels. METHODS:A randomized controlled trial design was used. The study was conducted on 59 first-year nursing students ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000401

    authors: Terzi B,Topbaş E,Bingöl G,Mavi Aydoğdu SG

    更新日期:2019-12-01 00:00:00

  • Which is the correct term for blood pressure measurements taken at home?

    abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200308000-00007

    authors: Stergiou GS

    更新日期:2003-08-01 00:00:00

  • Intense aerobic exercise lowers blood pressure in individuals with metabolic syndrome taking antihypertensive medicine.

    abstract:OBJECTIVE:There is a growing tendency for physicians to prescribe exercise in accordance with the 'exercise is medicine' global health initiative. However, the exercise-pharmacologic interactions for controlling blood pressure are not well described. Our purpose was to study whether angiotensin II receptor type 1 block...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000328

    authors: Ramirez-Jimenez M,Fernandez-Elias V,Morales-Palomo F,Ortega JF,Mora-Rodriguez R

    更新日期:2018-10-01 00:00:00

  • Feasibility of oscillometric aortic pressure and stiffness assessment using the VaSera VS-1500: comparison with a common tonometric method.

    abstract:OBJECTIVES:A number of operator-independent oscillometric devices to measure hemodynamics and arterial stiffness became available recently, but some and in particular VaSera VS-1500 do not provide estimates of aortic pressures and aortic pulse wave velocity (aPWV). The aim of this work was the retrospective application...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000137

    authors: Endes S,Bachler M,Li Y,Mayer C,Hanssen H,Hametner B,Schmidt-Trucksäss A,Wassertheurer S

    更新日期:2015-10-01 00:00:00

  • Validation protocols for blood pressure-measuring devices: status quo and development needs.

    abstract::Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000150

    authors: Beime B,Deutsch C,Gomez T,Zwingers T,Mengden T,Bramlage P

    更新日期:2016-02-01 00:00:00

  • From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

    abstract::Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early...

    journal_title:Blood pressure monitoring

    pub_type: 传,历史文章,杂志文章

    doi:10.1097/MBP.0b013e3283380e1e

    authors: Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

    更新日期:2010-04-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • Beneficial response of blood pressure to short-term continuous positive airway pressure in Chinese patients with obstructive sleep apnea-hypopnea syndrome.

    abstract:BACKGROUND:Obstructive sleep apnea-hypopnea syndrome (OSAHS) is common in people with hypertension and cardiac rhythm disorder. The objectives of this study were to determine the effect of short-term continuous positive airway pressure (CPAP) on blood pressure (BP) and cardiac rhythm in Chinese patients with moderate t...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000324

    authors: Wang X,Qiu J,Wang Y,Cai Z,Lu X,Li T

    更新日期:2018-08-01 00:00:00

  • High-intensity handgrip training lowers blood pressure and increases heart rate complexity among postmenopausal women: a pilot study.

    abstract:OBJECTIVE:Handgrip exercise is an emerging strategy for resting blood pressure (BP) reduction requiring minimal time and exercise effort. However, the research literature is currently limited to handgrip protocol designs predominantly prescribing sustained grip contractions, with little assessment of alternative option...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000313

    authors: Bentley DC,Nguyen CHP,Thomas SG

    更新日期:2018-04-01 00:00:00

  • Circadian variation of blood pressure and the assessment of antihypertensive therapy.

    abstract::The inherent variability of activity and the awake-sleep cycle creates changes in hemodynamics that may influence the outcome of a variety of cardiovascular disorders. Recently, data suggest that increased variability of blood pressure may promote excessive hypertensive target organ disease. Several epidemiologic stud...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: White WB

    更新日期:1999-01-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Sensitivity, specificity, and predictive values of a forearm blood pressure measurement method in severe obesity.

    abstract::For blood pressure assessment, it has been reported that forearm blood pressure measurement appears to be as valid as an upper-arm blood pressure measurement method in individuals with severe obesity when correlated to the intra-arterial method, considered as the gold standard. Sensitivity, specificity, and predictive...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000097

    authors: Leblanc MÈ,Cloutier L,Poirier P

    更新日期:2015-04-01 00:00:00

  • Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). PATIENTS AND METHODS:In 33 patients aged 32-79 years, BP measurements were performed alternately u...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000216

    authors: Beime B,Deutsch C,Krüger R,Zimmermann E,Bramlage P

    更新日期:2016-12-01 00:00:00

  • Propaq Neonatal monitor used with its own single- or with Critikon twin-hose cuffs: does it matter?.

    abstract::Some oscillometric non-invasive blood pressure (NIBP) monitors use twin-hose cuffs, whereas others use single-hose cuffs. The incompatibility hinders the transfer of patients from monitors using a single-hose cuff to monitors using twin-hose cuffs and vice versa. In particular, the Propaq Encore uses a single-hose cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Amoore JN

    更新日期:1997-12-01 00:00:00

  • Identification of subjects with white-coat hypertension and persistently normal ambulatory blood pressure.

    abstract::OBJECTIVE: To assess the spontaneous changes in clinic blood pressure, ambulatory blood pressure (ABP) and left ventricular structure in untreated subjects with white-coat hypertension (WCH). DESIGN: A prospective observational study. PATIENTS AND METHODS: In 83 untreated subjects with WCH, 24 h non-invasive ABP monit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Verdecchia P,Schillaci G,Borgioni C,Ciucci A,Gattobigio R,Sacchi N,Guerrieri M,Comparato E,Porcellati C

    更新日期:1996-06-01 00:00:00

  • Ambulatory blood pressure monitoring of chronically dialyzed pediatric patients.

    abstract:BACKGROUND:Background Ambulatory blood pressure monitoring (ABPM) has been shown to be more representative of blood pressure levels in adult patients than are casual measurements of blood pressure. OBJECTIVE:To evaluate, by means of ABPM, the behavior of blood pressure in children with chronic renal failure submitted ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Koch VH,Furusawa EA,Ignes E,Okay Y,Mion Junior D

    更新日期:1999-10-01 00:00:00

  • Sympathetic peripheral vasoconstriction may be measured using an artifact of the Finapres volume clamp technique.

    abstract:OBJECTIVES:The objective of this work was to test the hypothesis that the Finapres underestimates blood pressure during sympathetic peripheral vasoconstriction. METHODS:Measurements were made simultaneously with two Finapres devices and one radial artery tonometer during the onset of periodic lower body negative press...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e3282c9acc3

    authors: Birch AA

    更新日期:2007-10-01 00:00:00

  • Differential effects of antihypertensive drugs on circadian rhythm in blood pressure from the chronobiological point of view.

    abstract::REVIEW IN DEPTH: The cardiovascular system is well organized in time. The blood pressure normally displays a circadian rhythm characterized by a nightly drop which, however, can be disturbed by disease. The 24 h blood pressure and its mechanisms of regulation are very dynamic and rhythmic processes. Ambulatory blood p...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Lemmer B

    更新日期:1996-04-01 00:00:00

  • The application of generalizability theory to blood pressure resting levels and mental stress responses.

    abstract::BACKGROUND: Blood pressure measurements taken in the clinic or laboratory are assumed to generalize to the world outside. This is true both of casual blood pressure measurements and of changes in blood pressure responses to stress. Such generalizability is crucial to the usefulness of blood pressure measurements as pr...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Gerin W,Christenfeld N,Pieper C

    更新日期:1996-12-01 00:00:00

  • Reliability of home blood pressure monitoring: in the context of validation and accuracy.

    abstract:OBJECTIVE:Home blood pressure (BP) monitoring offers clinically relevant information enriched with more abundant data. However, there are few studies addressing the reliability of home BP devices and the quality of its data. This study aimed to evaluate the current status of home BP devices in terms of validation and a...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000121

    authors: Jung MH,Kim GH,Kim JH,Moon KW,Yoo KD,Rho TH,Kim CM

    更新日期:2015-08-01 00:00:00

  • Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT.

    abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200306000-00006

    authors: El Assaad MA,Topouchian JA,Asmar RG

    更新日期:2003-06-01 00:00:00