From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

Abstract:

:Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early publications of Pickering on diurnal BP variability and on the clinical application of self-measured BP. Pickering's work inspired many investigators worldwide and constituted a solid basis for further research. Pickering's original ideas led to algorithms for risk stratification involving white-coat hypertension and masked hypertension, diurnal BP variability, and self-measured BP. Recent studies validated Pickering's observations in terms of cardiovascular outcome and bridged the path from concept to application in clinical practice.

journal_name

Blood Press Monit

authors

Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

doi

10.1097/MBP.0b013e3283380e1e

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

72-81

issue

2

eissn

1359-5237

issn

1473-5725

pii

00126097-201004000-00003

journal_volume

15

pub_type

传,历史文章,杂志文章
  • Evaluation, management, and referral of elderly emergency department patients with elevated blood pressure.

    abstract:OBJECTIVES:To determine blood pressure (BP) reassessment rates and to describe the evaluation and outpatient referral rates of elderly emergency department (ED) patients with elevated BP. METHODS:This was a retrospective cohort of patients who were at least 60 years, presented with a systolic BP of at least 140 mmHg o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e328332fd40

    authors: Baumann BM,Cienki JJ,Cline DM,Egging D,Lehrmann JF,Tanabe P

    更新日期:2009-12-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Effect of fasting on 24-h blood pressure values of individuals with no previous history of hypertension.

    abstract:OBJECTIVE:We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. PATIENTS AND METHODS:This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage chang...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0000000000000244

    authors: Seker A,Demirci H,Ocakoglu G,Aydin U,Ucar H,Yildiz G,Yaman O

    更新日期:2017-10-01 00:00:00

  • Oscillometric sphygmomanometers: a critical appraisal of current technology.

    abstract:AIM:Blood pressure (BP), a key vital sign, monitors general health. Oscillometric devices are increasingly used for measurement, although their accuracy continues to be critically debated. A functional block diagram is used to review the components that affect accuracy. METHODS:A block diagram is presented covering th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0b013e32835026b0

    authors: Amoore JN

    更新日期:2012-04-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • Cardiovascular triggers and morning events.

    abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Chasen C,Muller JE

    更新日期:1998-02-01 00:00:00

  • Blood pressure control in anticoagulated hypertensive patients.

    abstract:OBJECTIVE:To compare the methods of office blood pressure (BP) measurement and ambulatory blood pressure monitoring (ABPM) to ensure optimal BP control in hypertensive anticoagulated patients. PATIENTS AND METHODS:Seventy-eight patients who were receiving antihypertensive drugs and warfarin in a dose-adjusted approach...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000084

    authors: Guzet F,Bitigen A,Karabay CY,Cimen AO,Teyfik N

    更新日期:2015-02-01 00:00:00

  • Relationship of vitamin D and parathyroid hormone with the nocturnal blood pressure decline in hypertension.

    abstract:OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated h...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000286

    authors: Karadag MK,Secen O

    更新日期:2017-12-01 00:00:00

  • An extended validation of the ScottCare 320 ambulatory blood pressure monitor: recommendations for clinical application.

    abstract:OBJECTIVES:The purpose of this study was to validate the ScottCare 320 ambulatory blood pressure monitor (ABPM) using both group-level and individual-level validation procedures. The group-level validation followed a modified protocol of the European Hypertension Society's validation protocol. The individual-level vali...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e32835f4fc7

    authors: Zawadzki MJ,Vandekar L,Smyth JM,Haas D,Gerin W

    更新日期:2013-06-01 00:00:00

  • Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    abstract:OBJECTIVE:To evaluate the accuracy of the YuWell YE680B oscillometric upper-arm blood pressure monitor for clinic and home blood pressure measurements in adults according to the American National Standards Institute/the Association for the Advancement of Medical Instrumentation/International Organization for Standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000405

    authors: Huang JF,Zhang W,Li Y,Wang JG

    更新日期:2019-12-01 00:00:00

  • Blood pressure measurement and the guidelines: a proposed new algorithm for the diagnosis of hypertension.

    abstract::Current hypertension guidelines continue to base management decisions on the office BP as recorded by mercury sphygmomanometry. The imminent disappearance of mercury from the workplace for environmental and safety reasons provides an opportunity to re-assess how a diagnosis of hypertension is made. There are now sever...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1097/00126097-200412000-00002

    authors: Myers MG

    更新日期:2004-12-01 00:00:00

  • Comparison of central blood pressure devices on the basis of a modified protocol of the European Society of Hypertension: application to the Centron cBP301.

    abstract:OBJECTIVES:Central blood pressure (cBP) and pulse pressure amplification (PPA) are receiving renewed interest with the increase in the availability of noninvasive techniques that enable its measurement. However, to date, there is no standardized protocol to validate their accuracy. Although invasive comparison seems in...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000028

    authors: Agnoletti D,Millasseau S,Topouchian J,Safar ME,Blacher J

    更新日期:2014-04-01 00:00:00

  • The choice of threshold limits for pediatric ambulatory blood pressure monitoring influences clinical decisions.

    abstract:OBJECTIVES:Hypertension in children may be defined by blood pressure elevated above the 95th percentile according to sex and age. Population data for ambulatory blood pressure provide different age-related and sex-related threshold limits to office-derived data. We sought to determine whether, when using ambulatory blo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209085.55364.73

    authors: Kennedy SE,Mackie FE,Craig E,Kainer G

    更新日期:2006-06-01 00:00:00

  • Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200106000-00008

    authors: Wright JM,Mattu GS,Perry TL Jr,Gelferc ME,Strange KD,Zorn A,Chen Y

    更新日期:2001-06-01 00:00:00

  • Ambulatory blood pressure variability: a conceptual review.

    abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000230

    authors: Zawadzki MJ,Small AK,Gerin W

    更新日期:2017-04-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs.

    abstract::Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national s...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000081

    authors: Neuhauser HK,Ellert U,Thamm M,Adler C

    更新日期:2015-02-01 00:00:00

  • Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32834b4431

    authors: Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C

    更新日期:2011-10-01 00:00:00

  • Effect of bedtime melatonin ingestion on blood pressure of normotensive subjects.

    abstract::OBJECTIVE: To determine whether the evening intake of 5 mg melatonin affects 24 h arterial blood pressure and heart-rate profiles. METHODS: Twenty-one young normotensive subjects were administered placebo or melatonin for 4 weeks, according to a cross-over double-blind design, and were subjected to ambulatory blood pr...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Lusardi P,Preti P,Savino S,Piazza E,Zoppi A,Fogari R

    更新日期:1997-04-01 00:00:00

  • The importance of the sympathetic nervous system and systolic hypertension in patients with hypertension: benefits in treating patients with increased cardiovascular risk.

    abstract::The sympathetic nervous system is intimately involved in both the origin and the perpetuation of the hypertensive state, although there is some debate as to its precise contribution to the long-term hypertensive condition. Catecholamines are leading candidates to be both the pressor mechanism that initiates the rise i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200010002-00005

    authors: Sica DA

    更新日期:2000-01-01 00:00:00

  • Quality of blood pressure phenotype in the Nigerian Population Research on Environment Gene and Health.

    abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000053

    authors: Odili AN,Ameh VO,Ogedengbe JO,Staessen JA

    更新日期:2014-08-01 00:00:00

  • The German Hypertension League (Deutsche Hochdruckliga) Quality Seal Protocol for blood pressure-measuring devices: 15-year experience and results from 105 devices for home blood pressure control.

    abstract:OBJECTIVE:The German Hypertension League (Deutsche Hochdruckliga) established a program to assess the accuracy and reliability of blood pressure (BP)-measuring devices in 1999 (Quality Seal Protocol). Here, we report on the results of a testing series of 105 devices designed for BP self-measurement. METHODS:The test p...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000186

    authors: Tholl U,Lüders S,Bramlage P,Dechend R,Eckert S,Mengden T,Nürnberger J,Sanner B,Anlauf M

    更新日期:2016-08-01 00:00:00

  • Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT.

    abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200306000-00006

    authors: El Assaad MA,Topouchian JA,Asmar RG

    更新日期:2003-06-01 00:00:00

  • Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing.

    abstract:OBJECTIVE:The Welch Allyn Pro BP 2000, an automated sphygmomanometer, was subjected to ANSI/AAMI/ISO testing. PATIENTS AND METHODS:The protocol used was the same-arm sequential procedure described in the ANSI/AAMI/ISO 2013 Standard. Eight-eight (53 adults and 35 children aged 3-12 years old) patients completed testing...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000350

    authors: Alpert BS

    更新日期:2018-12-01 00:00:00

  • Prognostic value of average real variability of systolic blood pressure in elderly treated hypertensive patients.

    abstract:OBJECTIVE:The independent prognostic significance of ambulatory blood pressure variability in the elderly is incompletely clear. We investigated the prognostic value of average real variability of 24-hour blood pressure in elderly treated hypertensive patients. METHODS:The occurrence of a combined end-point including ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000381

    authors: Coccina F,Pierdomenico AM,Cuccurullo C,Pierdomenico SD

    更新日期:2019-08-01 00:00:00

  • Blood pressure monitoring in sleep: time to wake up.

    abstract::Hypertension is a highly common condition with well-established adverse consequences. Ambulatory blood pressure monitoring has repeatedly been shown to better predict cardiovascular outcomes and mortality, compared to single office visit blood pressure. Non-dipping of sleep-time blood pressure is an independent marker...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000426

    authors: Kwon Y,Stafford PL,Lim DC,Park S,Kim SH,Berry RB,Calhoun DA

    更新日期:2020-04-01 00:00:00

  • Acute effects of moderate-intensity and high-intensity exercise on hemodynamic and autonomic reactivity to the cold pressor test in young adults with excess body weight.

    abstract:OBJECTIVE:To investigate the effects of a single session of moderate-intensity and high-intensity interval exercise in cardiovascular reactivity to the cold pressor test in young adults with excess body weight. METHODS:Twenty-two subjects with excess body weight (23 ± 2 years; 30.0 ± 3.4 kg·m) performed three sessions...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000422

    authors: Meireles K,Peçanha T,Dias ARL,Souza KA,Araújo JA,Silva JS,Rezende DAN,Santos RJ,Cambri LT,Arsa G

    更新日期:2020-04-01 00:00:00

  • Ambulatory blood pressure variation in normotensive subjects in relation to the sitting or standing position.

    abstract:OBJECTIVE:To evaluate the physiological variations in arterial blood pressure in normotensive subjects during activity and in relation to the sitting or lying position. METHODS:The subjects were 30 healthy volunteers who were normotensive and receiving no treatment. Blood pressure was measured using the validated moni...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200006000-00005

    authors: Mallion JM,Mouret S,Baguet JP,Maître A,Quesada JL,De Gaudemaris R

    更新日期:2000-06-01 00:00:00