Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs.

Abstract:

:Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national survey BP protocols: a standard mercury sphygmomanometer and an oscillometric device, Datascope Accutorr Plus, each with specific manufacturer-provided cuffs and cuff-selection rules. A sample of 105 adults were subjected to alternate same-arm BP measurements according to the principles of the International Protocol revision 2010 for the validation of BP-measuring devices in adults of the European Society of Hypertension. In all, 315 BP measurement pairs were obtained. The mean systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher by the standard mercury old protocol and increased with BP, age, and pulse pressure, and were associated with the ratios of the cuff width to the arm circumference. The mean systolic difference (datascope new protocol-standard mercury old protocol) in participants with old protocol: for SBP<120 was -3.5 ± 4.9 mmHg (n=162), for SBP 120-139 (n=108) was -6.4 ± 5.8 mmHg, and for SBP ≥ 140 (n=45) was -11.9 ± 7.2 mmHg. For DBP<80/80-89/≥ 90 in 230/67/18 participants, the differences were -1.9 ± 5.0/-6.8 ± 5.9/-7.6 ± 5.2 mmHg. A calibration formula for SBP derived from linear regression modeling includes SBP, sex, age, pulse pressure, and the difference in the cuff-width to arm-circumference ratios for the two devices (for DBP without age). Our study suggests that even in a highly standardized national survey environment, reported agreement from validation studies may not be replicable and comparisons in the specific clinical or research setting can be useful before replacing the mercury device completely.

journal_name

Blood Press Monit

authors

Neuhauser HK,Ellert U,Thamm M,Adler C

doi

10.1097/MBP.0000000000000081

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

39-42

issue

1

eissn

1359-5237

issn

1473-5725

journal_volume

20

pub_type

杂志文章
  • Angiotensin II receptor blockers following intravenous nicardipine administration to lower blood pressure in patients with hypertensive intracerebral hemorrhage: a prospective randomized study.

    abstract:BACKGROUND AND OBJECTIVE:In patients with hypertensive intracerebral hemorrhage (HICH), intravenous nicardipine is primarily used to lower blood pressure (BP). However, there are few studies investigating the role of oral antihypertensives administered after intravenous nicardipine to prevent BP from rising. Angiotensi...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000225

    authors: Inamasu J,Nakae S,Adachi K,Hirose Y

    更新日期:2017-02-01 00:00:00

  • Blood pressure control in anticoagulated hypertensive patients.

    abstract:OBJECTIVE:To compare the methods of office blood pressure (BP) measurement and ambulatory blood pressure monitoring (ABPM) to ensure optimal BP control in hypertensive anticoagulated patients. PATIENTS AND METHODS:Seventy-eight patients who were receiving antihypertensive drugs and warfarin in a dose-adjusted approach...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000084

    authors: Guzet F,Bitigen A,Karabay CY,Cimen AO,Teyfik N

    更新日期:2015-02-01 00:00:00

  • Assessment of antihypertensive efficacy by non-invasive ambulatory blood pressure monitoring.

    abstract::The session devoted to the usefulness of non-invasive ambulatory blood pressure monitoring (ABPM) in the evaluation of antihypertensive therapy allowed us to discuss a number of important issues. ABPM emerged as a widely accepted technique to measure blood pressure in clinical trials. Actually, it was generally consid...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Asmar R,Waeber B

    更新日期:1996-06-01 00:00:00

  • Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS:Systolic and diastolic b...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000261

    authors: Kang YY,Chen Q,Liu CY,Li Y,Wang JG

    更新日期:2017-08-01 00:00:00

  • Comparison of the effects of two different teaching methods in blood pressure measurement training: a randomized controlled study.

    abstract:OBJECTIVE:To compare the effects of a high-fidelity simulator and conventional teaching model used during blood pressure measurement training on students' self-confidence, self-efficacy and anxiety levels. METHODS:A randomized controlled trial design was used. The study was conducted on 59 first-year nursing students ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000401

    authors: Terzi B,Topbaş E,Bingöl G,Mavi Aydoğdu SG

    更新日期:2019-12-01 00:00:00

  • Hypertension in psoriasis patients: based on office and ambulatory blood pressure measurement.

    abstract:OBJECTIVE:Psoriasis is a chronic inflammatory disorder, which is associated with high risk of metabolic comorbidities. Hypertension (HTN) is among the most common and serious associations. In this study, we aimed to evaluate HTN in psoriatic patients through office and ambulatory blood pressure monitoring (ABPM). MATE...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000489

    authors: Abedini R,Najafi MT,Azizpour A,Nasimi M,Darreshiri M,Teymourpour A

    更新日期:2020-12-01 00:00:00

  • Frequency domain of heart rate and blood pressure variability in essential hypertensive patients during sleep: differences between dippers and non-dippers.

    abstract::METHODS: Autonomic nervous function was evaluated by means of power spectral analysis of heart rate and blood pressure variability in dipper (n = 10) and non-dipper (n = 9) essential hypertensive subjects during sleep. The non-dipper subjects were defined as those in whom the nocturnal decrease in blood pressure was <...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Frisina N,Pedullà M,Mento G,Lanuzza B

    更新日期:1996-10-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT.

    abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200306000-00006

    authors: El Assaad MA,Topouchian JA,Asmar RG

    更新日期:2003-06-01 00:00:00

  • Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

    abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200502000-00005

    authors: Højgaard MV,Holstein-Rathlou NH,Agner E,Kanters JK

    更新日期:2005-02-01 00:00:00

  • Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review.

    abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000344

    authors: Sprague E,Padwal RS

    更新日期:2018-10-01 00:00:00

  • Which is the correct term for blood pressure measurements taken at home?

    abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200308000-00007

    authors: Stergiou GS

    更新日期:2003-08-01 00:00:00

  • Frequency of spontaneous fist clenching during routine blood pressure measurements and its effect on measurement accuracy.

    abstract:BACKGROUND:Guidelines for office blood pressure reading techniques do not warn us about the possibility that patients may clench their fist during cuff-inflation. It is unknown how often patients do this, and what effect it has on measured blood pressure readings. DESIGN AND METHODS:We registered double blood pressure...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200206000-00001

    authors: Smulders YM,Godfried MH,van Montfrans GA

    更新日期:2002-06-01 00:00:00

  • Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards

    abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328330c873

    authors: Polo Friz H,Facchetti R,Primitz L,Beltrame L,Galbiati V,Ricioppo A,Bombelli M,Sega R

    更新日期:2009-10-01 00:00:00

  • The impact of the day of the week on home blood pressure: the Finn-Home study.

    abstract:OBJECTIVE:The impact of the day of the week on home blood pressure (BP) level and day-to-day BP profile is unknown. Our objectives were to examine (i) how the initial measurement day of the week affects 3-day and 7-day mean home BP and (ii) the BP variation between different days of the week. PARTICIPANTS AND METHODS:...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000156

    authors: Juhanoja EP,Puukka PJ,Johansson JK,Niiranen TJ,Jula AM

    更新日期:2016-04-01 00:00:00

  • Repeatability of blood pressure measurements during treadmill exercise.

    abstract:OBJECTIVE:Blood pressure measurements during exercise are difficult to obtain but are used widely in clinical practice. The objective of this study was to investigate the repeatability of blood pressure measurements and gas exchange parameters during treadmill exercise. METHODS:Participants were 10 healthy and nonsmok...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e328351de5c

    authors: Instebø A,Helgheim V,Greve G

    更新日期:2012-04-01 00:00:00

  • Potential hypotensive effects of Umezu polyphenols: a 14-week community-based, double-masked and placebo-controlled trial.

    abstract:OBJECTIVE:To evaluate blood pressure (BP)-lowering effects of Umezu polyphenols, polyphenols contained in Japanese plums, in a community-based sample by double-masked and placebo-controlled design. METHODS:Seventy-two Japanese community-dwellers who were interested in prevention or control of their BP (preferably high...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000476

    authors: Takemura S,Yoshimasu K,Tsuno K,Kuroda M,Kishida K,Mitani T,Miyashita K

    更新日期:2020-12-01 00:00:00

  • Reproducibility of ambulatory blood pressure measurements in essential hypertension.

    abstract:BACKGROUND:Data on the reproducibility of serial measurements of ambulatory blood pressure in hypertensive patients are lacking. The purpose of this study was to examine (1) the reproducibility of four consecutive ambulatory blood pressure measurements, and (2) the reproducibility of nocturnal falls in blood pressure i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200102000-00007

    authors: Zakopoulos NA,Nanas SN,Lekakis JP,Vemmos KN,Kotsis VT,Pitiriga VC,Stamatelopoulos SF,Moulopoulos SD

    更新日期:2001-02-01 00:00:00

  • Feasibility of oscillometric aortic pressure and stiffness assessment using the VaSera VS-1500: comparison with a common tonometric method.

    abstract:OBJECTIVES:A number of operator-independent oscillometric devices to measure hemodynamics and arterial stiffness became available recently, but some and in particular VaSera VS-1500 do not provide estimates of aortic pressures and aortic pulse wave velocity (aPWV). The aim of this work was the retrospective application...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000137

    authors: Endes S,Bachler M,Li Y,Mayer C,Hanssen H,Hametner B,Schmidt-Trucksäss A,Wassertheurer S

    更新日期:2015-10-01 00:00:00

  • Nocturnal blood pressure nondipping in obese African-Americans.

    abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346a871

    authors: Napan S,Kwagyan J,Randall OS,Xu S,Ketete M,Maqbool AR

    更新日期:2011-06-01 00:00:00

  • The effects of renal denervation on resistant hypertension patients: a meta-analysis.

    abstract::We carried out this meta-analysis to assess the effects of renal denervation (RDN) on resistant hypertension patients. According to the collaborative review group search strategy, we searched MEDLINE (1996 to 2015.10); EBCO (1996 to 2015.10) and CNKI. A meta-analysis was carried out using RevMan 5.0. We identified 11 ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/MBP.0000000000000177

    authors: Zhang X,Wu N,Yan W,Zhou C,Guo H

    更新日期:2016-08-01 00:00:00

  • Rationale and design of HOMED-BP Study: hypertension objective treatment based on measurement by electrical devices of blood pressure study.

    abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00126097-200202000-00016

    authors: Fujiwara T,Nishimura T,Ohkuko T,Imai Y,HOMED-BP Study Group.

    更新日期:2002-02-01 00:00:00

  • Is blunted heart rate decrease at night associated with prevalent organ damage in essential hypertension?

    abstract:AIM:The association between a blunted decrease in day–night heart rate and subclinical organ damage has not been investigated earlier in human hypertension. Therefore, we assessed such an association in a cohort of 658 untreated essential hypertensive patients. METHODS:All patients underwent procedures including cardi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/mbp.0b013e32834331fe

    authors: Cuspidi C,Meani S,Negri F,Valerio C,Sala C,Mancia G

    更新日期:2011-02-01 00:00:00

  • Validation of TM-2655 oscillometric device for blood pressure measurement.

    abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000200484.49540.12

    authors: Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

    更新日期:2006-04-01 00:00:00

  • Sympathetic peripheral vasoconstriction may be measured using an artifact of the Finapres volume clamp technique.

    abstract:OBJECTIVES:The objective of this work was to test the hypothesis that the Finapres underestimates blood pressure during sympathetic peripheral vasoconstriction. METHODS:Measurements were made simultaneously with two Finapres devices and one radial artery tonometer during the onset of periodic lower body negative press...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e3282c9acc3

    authors: Birch AA

    更新日期:2007-10-01 00:00:00

  • Determination of accuracy in neonates for non-invasive blood pressure device using an improved algorithm.

    abstract:BACKGROUND:New software (SuperSTAT(R) algorithm) with enhancements aimed at shorter determination times was developed for a non-invasive blood pressure (NIBP) device and a clinical evaluation was conducted to verify accuracy. OBJECTIVE:To determine the accuracy of the new algorithm according to ANSI/AAMI SP10-1992 and...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200204000-00006

    authors: Nelson RM,Stebor AD,Groh CM,Timoney PM,Theobald KS,Friedman BA

    更新日期:2002-04-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Comparison of central blood pressure devices on the basis of a modified protocol of the European Society of Hypertension: application to the Centron cBP301.

    abstract:OBJECTIVES:Central blood pressure (cBP) and pulse pressure amplification (PPA) are receiving renewed interest with the increase in the availability of noninvasive techniques that enable its measurement. However, to date, there is no standardized protocol to validate their accuracy. Although invasive comparison seems in...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000028

    authors: Agnoletti D,Millasseau S,Topouchian J,Safar ME,Blacher J

    更新日期:2014-04-01 00:00:00

  • Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension.

    abstract:OBJECTIVE:The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution. METHODS:Blood pressure indices, blood pressure loads and standard deviation scores were c...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32832ce11e

    authors: Jones DP,Richey PA,Alpert BS

    更新日期:2009-06-01 00:00:00

  • Characteristics of conventional blood pressure in studies on the predictive power of ambulatory blood pressure.

    abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析

    doi:10.1097/00126097-200202000-00006

    authors: Fagard RH,Staessen JA

    更新日期:2002-02-01 00:00:00