Relationship of vitamin D and parathyroid hormone with the nocturnal blood pressure decline in hypertension.

Abstract:

OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated hypertensive patients. PATIENTS AND METHODS:This cross-sectional study included a total of 73 hypertensive and 34 normotensive participants. Each patient underwent 24-hour ambulatory blood pressure monitoring, routine biochemical tests, vitamin D, and PTH analysis. RESULTS:The study population was divided into three groups according to ambulatory blood pressure monitoring records: 40 nondippers (mean age; 59.8±10.8 years, 24 women and 16 men), 33 dipper hypertensives (mean age; 58±11.8 years, 13 women and 20 men), and 34 normotensives (mean age; 56.9±11.7 years, 19 women and 15 men). Nondipper hypertensives showed lower levels of vitamin D than dippers and normotensives (9.7±6.1 vs. 14.9±10.1 vs. 16.4±9.5 ng/ml, P=0.001, for both) and higher levels of PTH than dippers (74.8±34.7 vs. 53.3±19.9 ng/ml, P=0.001). A significant positive correlation was observed between vitamin D and nocturnal decline (r=0.34, P=0.001), whereas a significant negative correlation was present between PTH and nocturnal decline(r=-0.26, P=0.006). In multivariate analysis, PTH level was correlated independently with nocturnal decline (β=-0.07, 95% confidence interval: -0.114-0.025, P=0.003). CONCLUSION:In this study, vitamin D levels were significantly lower and PTH levels were significantly higher in nondippers. The vitamin D level was correlated positively and the PTH level was correlated negatively with nocturnal decline. In addition, PTH level was associated independently with nocturnal decline in hypertension.

journal_name

Blood Press Monit

authors

Karadag MK,Secen O

doi

10.1097/MBP.0000000000000286

subject

Has Abstract

pub_date

2017-12-01 00:00:00

pages

322-327

issue

6

eissn

1359-5237

issn

1473-5725

journal_volume

22

pub_type

杂志文章
  • Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32834b4431

    authors: Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C

    更新日期:2011-10-01 00:00:00

  • Quality of blood pressure phenotype in the Nigerian Population Research on Environment Gene and Health.

    abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000053

    authors: Odili AN,Ameh VO,Ogedengbe JO,Staessen JA

    更新日期:2014-08-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Validation of the Omron HEM-907 device for blood pressure measurement.

    abstract:BACKGROUND:The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. DESIGN:The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200208000-00006

    authors: El Assaad MA,Topouchian JA,Darné BM,Asmar RG

    更新日期:2002-08-01 00:00:00

  • Propaq Neonatal monitor used with its own single- or with Critikon twin-hose cuffs: does it matter?.

    abstract::Some oscillometric non-invasive blood pressure (NIBP) monitors use twin-hose cuffs, whereas others use single-hose cuffs. The incompatibility hinders the transfer of patients from monitors using a single-hose cuff to monitors using twin-hose cuffs and vice versa. In particular, the Propaq Encore uses a single-hose cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Amoore JN

    更新日期:1997-12-01 00:00:00

  • Characteristics of conventional blood pressure in studies on the predictive power of ambulatory blood pressure.

    abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析

    doi:10.1097/00126097-200202000-00006

    authors: Fagard RH,Staessen JA

    更新日期:2002-02-01 00:00:00

  • High-intensity handgrip training lowers blood pressure and increases heart rate complexity among postmenopausal women: a pilot study.

    abstract:OBJECTIVE:Handgrip exercise is an emerging strategy for resting blood pressure (BP) reduction requiring minimal time and exercise effort. However, the research literature is currently limited to handgrip protocol designs predominantly prescribing sustained grip contractions, with little assessment of alternative option...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000313

    authors: Bentley DC,Nguyen CHP,Thomas SG

    更新日期:2018-04-01 00:00:00

  • The effects of renal denervation on resistant hypertension patients: a meta-analysis.

    abstract::We carried out this meta-analysis to assess the effects of renal denervation (RDN) on resistant hypertension patients. According to the collaborative review group search strategy, we searched MEDLINE (1996 to 2015.10); EBCO (1996 to 2015.10) and CNKI. A meta-analysis was carried out using RevMan 5.0. We identified 11 ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/MBP.0000000000000177

    authors: Zhang X,Wu N,Yan W,Zhou C,Guo H

    更新日期:2016-08-01 00:00:00

  • From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

    abstract::Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early...

    journal_title:Blood pressure monitoring

    pub_type: 传,历史文章,杂志文章

    doi:10.1097/MBP.0b013e3283380e1e

    authors: Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

    更新日期:2010-04-01 00:00:00

  • Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    abstract:OBJECTIVE:To evaluate the accuracy of the YuWell YE680B oscillometric upper-arm blood pressure monitor for clinic and home blood pressure measurements in adults according to the American National Standards Institute/the Association for the Advancement of Medical Instrumentation/International Organization for Standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000405

    authors: Huang JF,Zhang W,Li Y,Wang JG

    更新日期:2019-12-01 00:00:00

  • Masked hypertension, a review of the literature.

    abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/mbp.0b013e3280fb2792

    authors: Verberk WJ,Thien T,de Leeuw PW

    更新日期:2007-08-01 00:00:00

  • Impact of choosing the closest rather than the mean auscultatory blood pressure value on the European Society of Hypertension International Protocol device validation results.

    abstract:OBJECTIVE:When calculating the difference between alternating auscultatory reference standard (ARS) and the automated device-under-test (DUT) blood pressure (BP) measurements, the European Society of Hypertension International Protocol (ESH-IP) allows investigators to choose the closest ARS value to the DUT value, rath...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000454

    authors: Padwal R,Wood PW,McLean D,Ringrose JS

    更新日期:2020-08-01 00:00:00

  • 'Diagnostic mode' improves adherence to the home blood pressure measurement schedule.

    abstract:BACKGROUND:The accuracy of home blood pressure measurement (HBPM) depends on adherence to the measurement schedule. We investigated the number of deviations from the requested schedule using an HBPM device equipped with a diagnostic mode that only allows patients to take a fixed number of BP readings at preset times. ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e328357352a

    authors: Wessel SE,van der Hoeven NV,Cammenga M,van Montfrans GA,van den Born BJ

    更新日期:2012-10-01 00:00:00

  • A short standardized protocol for measuring the QKD interval: comparison with 24 h monitoring and reproducibility.

    abstract::BACKGROUND: Ambulatory measurement for the QKD interval is a new method for evaluation of the rigidity of large arterial trunks. Reliable indices of arterial rigidity can be distilled from the large number of measurements (usually around 100) obtained during 24 h monitoring. OBJECTIVE: To describe a shorter standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Mas D,Gosse P,Julien V V,Jarnier P,Lemetayer P,Clementy J

    更新日期:1998-08-01 00:00:00

  • Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor.

    abstract::OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various ar...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Baumgart P,Kamp J

    更新日期:1998-10-01 00:00:00

  • Accuracy of the WatchBP O3 device for ambulatory blood pressure monitoring according to the new criteria of the ISO81060-2 2018 protocol.

    abstract:OBJECTIVE:The aim of the study was to determine the accuracy of the Microlife WatchBP O3 monitor for ambulatory blood pressure (BP) measurement according to the new ISO81060-2 2018 protocol. METHODS:The WatchBP O3 was first tested in 97 subjects from the general population (mean age, 71.3 years; 48 men) using four cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000459

    authors: Fania C,Lazzaretto I,Fontana U,Palatini P

    更新日期:2020-10-01 00:00:00

  • Brachial or wrist blood pressure in obese patients: which is the best?

    abstract:OBJECTIVE:Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS:We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mann...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3282fd16e3

    authors: de Senarclens O,Feihl F,Giusti V,Engelberger RP,Rodieux F,Gomez P,Liaudet L,Waeber B

    更新日期:2008-06-01 00:00:00

  • White coat hypertension in children.

    abstract::Ambulatory blood pressure monitoring (ABPM) has become more widely used in the assessment of elevated blood pressure in children. The accurate diagnosis of white coat hypertension (WCH) is particularly important in children because detection of elevated blood pressure often results in expensive and invasive diagnostic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200008000-00001

    authors: Sorof JM

    更新日期:2000-08-01 00:00:00

  • A psychophysiologic reaction to application of ambulatory blood pressure monitor: fact or artifact?

    abstract:BACKGROUND:The study investigated the clinical significance of relatively high blood pressure (BP) elevations during the calibration of the ambulatory blood pressure monitor (ABPM). METHODS:Inferences were drawn from the analysis of differences between 'M', the average of five manually triggered responses, and 'W', th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328340ff51

    authors: Yanovski A,Townsend RR,Virginia F,Michael C

    更新日期:2011-02-01 00:00:00

  • Unchanged 24 h ambulatory blood pressure during shjort-term salt restriction and salt repletion in normotensive volunteers.

    abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Raeder H,Aaberg M,Omvik P

    更新日期:1996-02-01 00:00:00

  • Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200106000-00008

    authors: Wright JM,Mattu GS,Perry TL Jr,Gelferc ME,Strange KD,Zorn A,Chen Y

    更新日期:2001-06-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • Accuracy of oscillometric blood pressure algorithms in healthy adults and in adults with cardiovascular risk factors.

    abstract:BACKGROUND:Fixed-ratio and slope-based algorithms are used to derive oscillometric blood pressure (BP). However, a paucity of published data exists assessing the accuracy of these methods. Our objective was to determine the accuracy of fixed-ratio and slope-based algorithms in healthy adults and in adults with cardiova...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000356

    authors: Padwal R,Jalali A,McLean D,Anwar S,Smith K,Raggi P,Ringrose JS

    更新日期:2019-02-01 00:00:00

  • Relationship between noninvasive and invasive blood pressure values in end-stage renal disease patients on dialysis.

    abstract:BACKGROUND:End-stage renal disease (ESRD) is complicated by high blood pressure (BP) and severe atherosclerosis, which may lead to different values of BP measured by invasive and noninvasive methods. However, the differences in BP values between these two methods and their possible mechanisms in ESRD have not been inve...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000026

    authors: Chen Y,Zhu Y,Chen C,Chen X,Pan H,Chen S,Tan X

    更新日期:2014-04-01 00:00:00

  • Determination of accuracy in neonates for non-invasive blood pressure device using an improved algorithm.

    abstract:BACKGROUND:New software (SuperSTAT(R) algorithm) with enhancements aimed at shorter determination times was developed for a non-invasive blood pressure (NIBP) device and a clinical evaluation was conducted to verify accuracy. OBJECTIVE:To determine the accuracy of the new algorithm according to ANSI/AAMI SP10-1992 and...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200204000-00006

    authors: Nelson RM,Stebor AD,Groh CM,Timoney PM,Theobald KS,Friedman BA

    更新日期:2002-04-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

    abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200502000-00005

    authors: Højgaard MV,Holstein-Rathlou NH,Agner E,Kanters JK

    更新日期:2005-02-01 00:00:00

  • Reliability of home blood pressure monitoring: in the context of validation and accuracy.

    abstract:OBJECTIVE:Home blood pressure (BP) monitoring offers clinically relevant information enriched with more abundant data. However, there are few studies addressing the reliability of home BP devices and the quality of its data. This study aimed to evaluate the current status of home BP devices in terms of validation and a...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000121

    authors: Jung MH,Kim GH,Kim JH,Moon KW,Yoo KD,Rho TH,Kim CM

    更新日期:2015-08-01 00:00:00

  • Hidden errors of aneroid sphygmomanometers.

    abstract:BACKGROUND:Measurement of blood pressure remains the most commonly performed screening test in medical practice. With the likely removal of mercury sphygmomanometers from the workplace alternative devices are required. Of these the aneroid sphygmomanometer is popular both in the community and hospital setting. We inves...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200212000-00003

    authors: Waugh JJ,Gupta M,Rushbrook J,Halligan A,Shennan AH

    更新日期:2002-12-01 00:00:00

  • Prediction of strokes versus cardiac events by ambulatory monitoring of blood pressure: results from an international database.

    abstract::We performed this study to elucidate the role of nighttime versus daytime ambulatory blood pressure in predicting stroke and cardiac events. The International Collaborative Study of the Prognostic Utility of ABPM, which includes prospective cohort studies of ambulatory blood pressure monitoring (ABPM) from seven sites...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e3282411a12

    authors: Pickering T,Schwartz J,Verdecchia P,Imai Y,Kario K,Eguchi K,Pierdomenico S,Ohkubo T,Wing L