Abstract:
BACKGROUND:The accuracy of home blood pressure measurement (HBPM) depends on adherence to the measurement schedule. We investigated the number of deviations from the requested schedule using an HBPM device equipped with a diagnostic mode that only allows patients to take a fixed number of BP readings at preset times. METHODS:We randomized patients to measure their BP as recommended by the European Society of Hypertension guideline in either the usual mode or the diagnostic mode. RESULTS:A total of 135 patients were included, mean age 54.4 ± 13.6 years, 57 (42.2%) men, with a mean systolic BP of 147.0 ± 18.4 mmHg and a mean diastolic BP of 88.0 ± 10.3 mmHg. In 66 patients, BP was measured in the diagnostic mode, whereas in 69 patients BP was measured in the usual mode. In the diagnostic mode, 40% of patients showed full adherence to the measurement schedule, compared with 23% of patients in the usual mode (P = 0.02). Unscheduled measurements were performed by 55% of patients measuring BP in the usual mode and none in the diagnostic mode. The number of patients who omitted readings was similar in the diagnostic and the usual mode (P = 0.9). Compared with scheduled readings only, 12% of patients measuring BP in the usual mode fell into a different BP category, whereas reclassification did not occur in patients using the diagnostic mode (P = 0.03). CONCLUSION:HBPM in the diagnostic mode almost doubled the number of patients with full adherence to the measurement schedule and eliminated the number of patients who were reclassified in a different BP category.
journal_name
Blood Press Monitjournal_title
Blood pressure monitoringauthors
Wessel SE,van der Hoeven NV,Cammenga M,van Montfrans GA,van den Born BJdoi
10.1097/MBP.0b013e328357352asubject
Has Abstractpub_date
2012-10-01 00:00:00pages
214-9issue
5eissn
1359-5237issn
1473-5725journal_volume
17pub_type
杂志文章,随机对照试验abstract:BACKGROUND:Although there is a theoretical basis for crossing legs to increase blood pressure, there are no published data addressing this question. As a result guidelines for measurement of blood pressure are not consistent in recommending that patients legs should not be crossed during measurement. OBJECTIVE:To dete...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:1999-04-01 00:00:00
abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000053
更新日期:2014-08-01 00:00:00
abstract:BACKGROUND:Ambulatory blood pressure monitoring (ABPM) on the oscillometric method is applicable in patients with atrial fibrillation, but the mean pulse rate is or not similar to the ventricular rate from the Holter in atrial fibrillation patients remains unknown. METHODS:This study included 228 persistent atrial fib...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000481
更新日期:2020-12-01 00:00:00
abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract:OBJECTIVE:Blood pressure measurements during exercise are difficult to obtain but are used widely in clinical practice. The objective of this study was to investigate the repeatability of blood pressure measurements and gas exchange parameters during treadmill exercise. METHODS:Participants were 10 healthy and nonsmok...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0b013e328351de5c
更新日期:2012-04-01 00:00:00
abstract:BACKGROUND:Patients with high office blood pressures but relatively normal readings during daytime ambulatory monitoring have been the subject of much investigation and debate. This clinical finding in part depends on an alerting reaction to the circumstances of the clinical measurement, often described as the 'white-c...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:2000-04-01 00:00:00
abstract:OBJECTIVE:The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). PATIENTS AND METHODS:In 33 patients aged 32-79 years, BP measurements were performed alternately u...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000216
更新日期:2016-12-01 00:00:00
abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-02-01 00:00:00
abstract:OBJECTIVES:Hypertension in children may be defined by blood pressure elevated above the 95th percentile according to sex and age. Population data for ambulatory blood pressure provide different age-related and sex-related threshold limits to office-derived data. We sought to determine whether, when using ambulatory blo...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/01.mbp.0000209085.55364.73
更新日期:2006-06-01 00:00:00
abstract::The acute effect of smoking is a rise in blood pressure and heart rate. Nevertheless, in several epidemiologic studies, smokers tend to have a slightly lower office blood pressure than non-smokers. We studied the 24 h ambulatory blood pressure consecutively in hypertensive smokers (> or = 10 cigarettes per day, n = 26...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200010000-00004
更新日期:2000-10-01 00:00:00
abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000451
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVE:There is a growing tendency for physicians to prescribe exercise in accordance with the 'exercise is medicine' global health initiative. However, the exercise-pharmacologic interactions for controlling blood pressure are not well described. Our purpose was to study whether angiotensin II receptor type 1 block...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0000000000000328
更新日期:2018-10-01 00:00:00
abstract::OBJECTIVE: To investigate whether blood pressure monitoring is reproducible. DESIGN: Reproducibility of ambulatory blood pressure monitoring data was assessed by means of traditional and relatively new statistical methods, namely correlation coefficients, regression analysis and agreement analysis. METHODS: Ninety-one...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-04-01 00:00:00
abstract:BACKGROUND:The study investigated the clinical significance of relatively high blood pressure (BP) elevations during the calibration of the ambulatory blood pressure monitor (ABPM). METHODS:Inferences were drawn from the analysis of differences between 'M', the average of five manually triggered responses, and 'W', th...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328340ff51
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVE:The impact of the day of the week on home blood pressure (BP) level and day-to-day BP profile is unknown. Our objectives were to examine (i) how the initial measurement day of the week affects 3-day and 7-day mean home BP and (ii) the BP variation between different days of the week. PARTICIPANTS AND METHODS:...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000156
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated h...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000286
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200110000-00005
更新日期:2001-10-01 00:00:00
abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1097/00126097-200104000-00005
更新日期:2001-04-01 00:00:00
abstract:OBJECTIVE:The German Hypertension League (Deutsche Hochdruckliga) established a program to assess the accuracy and reliability of blood pressure (BP)-measuring devices in 1999 (Quality Seal Protocol). Here, we report on the results of a testing series of 105 devices designed for BP self-measurement. METHODS:The test p...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000186
更新日期:2016-08-01 00:00:00
abstract:OBJECTIVES:Monitoring of brachial blood pressure during exercise-electrocardiogram (ECG) testing is mandatory and changes in blood pressure (BP) can provide critical management evidence. Patient movement, mechanical vibration, artifactual sounds and observer variability make standard manual techniques problematic. This...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200410000-00007
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:Pulse wave velocity (PWV) is a measure of arterial stiffness and a marker for cardiovascular disease. Although commonly used, there are only a few reports investigating the intersession and intrasession variability in PWV measurements, the determination of which is important in a mixed population when using P...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000052
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e32835026c6
更新日期:2012-02-01 00:00:00
abstract:OBJECTIVE:The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS:Systolic and diastolic b...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000261
更新日期:2017-08-01 00:00:00
abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200306000-00006
更新日期:2003-06-01 00:00:00
abstract::Hypertension is highly prevalent in pediatric patients with end-stage renal disease (ESRD). Ambulatory blood pressure monitoring (ABPM) has been used to characterize the altered circadian blood pressure patterns in ESRD in order to improve our understanding of the blood pressure dysregulation that occurs in these chil...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:
更新日期:1999-06-01 00:00:00
abstract:BACKGROUND:Arterial hypertension is associated with cardiovascular morbidity and mortality. It was previously shown that left atrium volume increase associated with mortality and atherosclerotic heart disease. The aim of the present study was to demonstrate the value of endothelial dysfunction in predicting left atrium...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000419
更新日期:2020-04-01 00:00:00
abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0b013e3282f3859d
更新日期:2008-02-01 00:00:00
abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,meta分析
doi:10.1097/00126097-200202000-00006
更新日期:2002-02-01 00:00:00
abstract:OBJECTIVE:When calculating the difference between alternating auscultatory reference standard (ARS) and the automated device-under-test (DUT) blood pressure (BP) measurements, the European Society of Hypertension International Protocol (ESH-IP) allows investigators to choose the closest ARS value to the DUT value, rath...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000454
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVE:Current guidelines for office blood pressure (BP) measurement recommend mercury devices, both arms measurement in the initial assessment and at least duplicate measurements at follow-up visits. This study presents the design and a pilot application study of an automated device that fulfils American, European,...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3283057a84
更新日期:2008-08-01 00:00:00