Accuracy of automated auscultatory blood pressure measurement during supine exercise and treadmill stress electrocardiogram-testing.

Abstract:

OBJECTIVES:Monitoring of brachial blood pressure during exercise-electrocardiogram (ECG) testing is mandatory and changes in blood pressure (BP) can provide critical management evidence. Patient movement, mechanical vibration, artifactual sounds and observer variability make standard manual techniques problematic. This was an investigator-initiated study to assess an automated auscultatory technique of BP assessment [Tango exercise blood pressure monitor (SunTech Medical Instruments, NC, USA)] to adequately measure BP during stress-ECG testing. METHODS:Initially five fit young male volunteers underwent invasive right brachial artery BP recording using a low-compliance fluid-filled catheter with simultaneous manual and automated assessment. Secondarily, during exercise-ECG testing, the system was assessed against beat-to-beat brachial blood pressures obtained from a catheter-tip solid-state pressure manometer positioned in the ipsilateral brachial artery. RESULTS:In the supine study overall mean difference (+/-SEM) between invasive and manual blood pressures was 3.26 (1.53) and 3.89 (1.90) mmHg for diastolic BP (DBP) and systolic BP (SBP) respectively. Corresponding differences between invasive and automated results, and manual and automated were 3.68 (0.84) and -7.31 (1.83) mmHg, and -0.64 (+/-1.43) and -11.42 (+/-1.59) mmHg. During treadmill exercise-ECG testing the combined mean difference (+/-SEM) between invasive and automated SBP and DBP was 4.79 (+/-0.14) and 6.33 (+/-0.10) mmHg, respectively. CONCLUSION:Automated BP assessment during exercise-ECG testing is feasible with the use of appropriate automatic devices likely to be at least as accurate as manual BP registration. The Tango device is tolerant to exercise and provides reliable automatic BP assessment with absolute differences within an acceptable clinical range.

journal_name

Blood Press Monit

authors

Cameron JD,Stevenson I,Reed E,McGrath BP,Dart AM,Kingwell BA

doi

10.1097/00126097-200410000-00007

subject

Has Abstract

pub_date

2004-10-01 00:00:00

pages

269-75

issue

5

eissn

1359-5237

issn

1473-5725

pii

00126097-200410000-00007

journal_volume

9

pub_type

杂志文章
  • Validation of the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor to the ISO Standard and BHS protocol.

    abstract:OBJECTIVE:We evaluated the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor accuracy by both the International Standards Organization (ISO) Standard and the British Hypertension Society (BHS) protocol. METHODS:We tested children, adolescents, and adults. The requirements for both ISO and BHS were completed f...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32833c8b39

    authors: Alpert BS

    更新日期:2010-10-01 00:00:00

  • Effects of the angiotensin II receptor blockers telmisartan versus valsartan in combination with hydrochlorothiazide: a large, confirmatory trial.

    abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e3282f3859d

    authors: White WB,Murwin D,Chrysant SG,Koval SE,Davidai G,Guthrie R

    更新日期:2008-02-01 00:00:00

  • Reproducibility of ambulatory blood pressure monitoring.

    abstract::OBJECTIVE: To investigate whether blood pressure monitoring is reproducible. DESIGN: Reproducibility of ambulatory blood pressure monitoring data was assessed by means of traditional and relatively new statistical methods, namely correlation coefficients, regression analysis and agreement analysis. METHODS: Ninety-one...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Musso NR,Lotti G

    更新日期:1996-04-01 00:00:00

  • Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor.

    abstract::OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various ar...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Baumgart P,Kamp J

    更新日期:1998-10-01 00:00:00

  • Morning hypertension in chronic kidney disease is sustained type, but not surge type.

    abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32835026c6

    authors: Mizuno M,Fukuda M,Miura T,Wakamatsu T,Naito T,Sato R,Togawa H,Sasakawa Y,Tomonari T,Ono M,Kato Y,Ichikawa T,Shirasawa Y,Ito A,Yoshida A,Kimura G

    更新日期:2012-02-01 00:00:00

  • Ambulatory blood pressure monitoring of chronically dialyzed pediatric patients.

    abstract:BACKGROUND:Background Ambulatory blood pressure monitoring (ABPM) has been shown to be more representative of blood pressure levels in adult patients than are casual measurements of blood pressure. OBJECTIVE:To evaluate, by means of ABPM, the behavior of blood pressure in children with chronic renal failure submitted ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Koch VH,Furusawa EA,Ignes E,Okay Y,Mion Junior D

    更新日期:1999-10-01 00:00:00

  • Potential hypotensive effects of Umezu polyphenols: a 14-week community-based, double-masked and placebo-controlled trial.

    abstract:OBJECTIVE:To evaluate blood pressure (BP)-lowering effects of Umezu polyphenols, polyphenols contained in Japanese plums, in a community-based sample by double-masked and placebo-controlled design. METHODS:Seventy-two Japanese community-dwellers who were interested in prevention or control of their BP (preferably high...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000476

    authors: Takemura S,Yoshimasu K,Tsuno K,Kuroda M,Kishida K,Mitani T,Miyashita K

    更新日期:2020-12-01 00:00:00

  • Clinical use of ambulatory blood pressure monitoring in a Veteran's Medical Center.

    abstract::BACKGROUND: The lack of prospective data on the relative value of ambulatory blood pressure compared with office blood pressure as well as concern about increased costs have led to cautious endorsement of such monitoring in the clinical arena. Several consensus bodies have reviewed the scientific evidence and have sug...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Mansoor GA

    更新日期:1997-10-01 00:00:00

  • Validation of the A&D wrist-cuff UB-511 (UB-512) device for self-measurement of blood pressure.

    abstract:OBJECTIVES:To determine the accuracy of the A&D UB-511 (UB-512) oscillometric wrist-cuff device for self-measurement of blood pressure, the only difference between the two devices being the size of storage memory. METHODS:Device evaluation was performed according to the modified British Hypertension Society protocol r...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/01.mbp.0000217995.12215.f2

    authors: Angeli F,Sardone M,Angeli E,Repaci S,Gattobigio R,Verdecchia P

    更新日期:2006-12-01 00:00:00

  • Validation of the TM-2564G device for in-hospital blood pressure measurement.

    abstract:OBJECTIVE:To perform clinical validation of the TM-2564G device for in-hospital blood pressure measurement according to the British Hypertension Society protocol. METHODS:The tests were carried out on 85 patients aged 19-82 years (41 male patients, mean age 50+/-19 years) with systolic blood pressure 75-219 mmHg and d...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200512000-00009

    authors: Kobalava ZD,Kotovskaya YV,Rodionov EV,Moiseev VS

    更新日期:2005-12-01 00:00:00

  • Effects of race and sex on blood pressure and hemodynamic stress response as a function of the menstrual cycle.

    abstract::OBJECTIVE: To examine the influence of race and sex on responses to cardiovascular stress during two menstrual cycle phases. METHODS: Subjects were exposed to two stressors, a mirror star-tracing task and a speaking task. Blood pressure, heart rate, and impedance cardiography measures of reactivity were recorded. Wome...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Ahwal WN,Mills PJ,Kalshan DA,Nelesen RA

    更新日期:1997-08-01 00:00:00

  • Interindividual and intraindividual variation in pulse wave velocity measurements in a male population.

    abstract:OBJECTIVE:Pulse wave velocity (PWV) is a measure of arterial stiffness and a marker for cardiovascular disease. Although commonly used, there are only a few reports investigating the intersession and intrasession variability in PWV measurements, the determination of which is important in a mixed population when using P...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000052

    authors: Tripkovic L,Hart KH,Frost GS,Lodge JK

    更新日期:2014-08-01 00:00:00

  • The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    abstract:OBJECTIVE:To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. PARTICIPANTS AND METHODS:This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000141

    authors: Shangguan Q,Wu Y,Xu J,Su H,Li J,Hong K,Cheng X

    更新日期:2015-12-01 00:00:00

  • Reproducibility of ambulatory blood pressure measurements in essential hypertension.

    abstract:BACKGROUND:Data on the reproducibility of serial measurements of ambulatory blood pressure in hypertensive patients are lacking. The purpose of this study was to examine (1) the reproducibility of four consecutive ambulatory blood pressure measurements, and (2) the reproducibility of nocturnal falls in blood pressure i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200102000-00007

    authors: Zakopoulos NA,Nanas SN,Lekakis JP,Vemmos KN,Kotsis VT,Pitiriga VC,Stamatelopoulos SF,Moulopoulos SD

    更新日期:2001-02-01 00:00:00

  • Ambulatory blood pressure monitoring in end-stage renal disease.

    abstract::BACKGROUND: Hypertension is responsible for substantial morbidity in end-stage renal disease. Ambulatory blood pressure monitoring has been used to understand the behavior of blood pressure in renal failure, especially during the interdialytic period for patients on hemodialysis. OBJECTIVE: To review the published dat...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Peixoto AJ,Sica DA

    更新日期:1997-12-01 00:00:00

  • The importance of the sympathetic nervous system and systolic hypertension in patients with hypertension: benefits in treating patients with increased cardiovascular risk.

    abstract::The sympathetic nervous system is intimately involved in both the origin and the perpetuation of the hypertensive state, although there is some debate as to its precise contribution to the long-term hypertensive condition. Catecholamines are leading candidates to be both the pressor mechanism that initiates the rise i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200010002-00005

    authors: Sica DA

    更新日期:2000-01-01 00:00:00

  • Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS:Systolic and diastolic b...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000261

    authors: Kang YY,Chen Q,Liu CY,Li Y,Wang JG

    更新日期:2017-08-01 00:00:00

  • Validation of the A&D BP UA-651 device with a wide-range cuff for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    abstract::The aim of this study was to determine the accuracy of the A&D BP UA-651 device coupled to a wide-range cuff for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. The device was evaluated in 33 patients. The mean age of the patients was 56.5±15.1 year...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000100

    authors: Benetti E,Fania C,Palatini P

    更新日期:2015-06-01 00:00:00

  • Prediction of strokes versus cardiac events by ambulatory monitoring of blood pressure: results from an international database.

    abstract::We performed this study to elucidate the role of nighttime versus daytime ambulatory blood pressure in predicting stroke and cardiac events. The International Collaborative Study of the Prognostic Utility of ABPM, which includes prospective cohort studies of ambulatory blood pressure monitoring (ABPM) from seven sites...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e3282411a12

    authors: Pickering T,Schwartz J,Verdecchia P,Imai Y,Kario K,Eguchi K,Pierdomenico S,Ohkubo T,Wing L

    更新日期:2007-12-01 00:00:00

  • The effect of Ramadan fasting on ambulatory blood pressure in treated hypertensive patients using diuretics.

    abstract:OBJECTIVE:The influence of the Ramadan fasting on blood pressure (BP) in patients taking diuretics therapy has not been addressed specifically yet. The aim of this study was to examine the effect of long Ramadan fasting on BP with ambulatory BP monitoring in hypertensive patients using diuretics. METHODS:This prospect...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000451

    authors: Aslan S,Riza Demir A,Kahraman S,Memiç K,Avci Y,Gürbak İ,Karabulut E,Ertürk M

    更新日期:2020-08-01 00:00:00

  • Beneficial response of blood pressure to short-term continuous positive airway pressure in Chinese patients with obstructive sleep apnea-hypopnea syndrome.

    abstract:BACKGROUND:Obstructive sleep apnea-hypopnea syndrome (OSAHS) is common in people with hypertension and cardiac rhythm disorder. The objectives of this study were to determine the effect of short-term continuous positive airway pressure (CPAP) on blood pressure (BP) and cardiac rhythm in Chinese patients with moderate t...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000324

    authors: Wang X,Qiu J,Wang Y,Cai Z,Lu X,Li T

    更新日期:2018-08-01 00:00:00

  • Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use.

    abstract:BACKGROUND:We have developed a new blood pressure (BP)-measuring device with a double-cuff, and evaluated its accuracy and applicability for practical use. DESIGN:The double-cuff method features a small cuff placed in the centre of the compression cuff to detect the oscillation of arterial pulsation, by which algorith...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00126097-200310000-00005

    authors: Tochikubo O,Nishijima K,Ohshige K,Kimura K

    更新日期:2003-10-01 00:00:00

  • Blood pressure cuff comparability study.

    abstract:BACKGROUND:Manufacturer-supplied blood pressure (BP) cuffs are part of the automatic oscillometric BP devices algorithm. MATERIALS AND METHODS:This study assessed the differences in BP values using the Omron HEM 907-XL (Omron) device with two types of cuffs: the Baum cuff (BC) and the supplied Omron cuff (OC). A sampl...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000208

    authors: Ostchega Y,Nwankwo T,Zhang G,Chiappa M

    更新日期:2016-12-01 00:00:00

  • The application of generalizability theory to blood pressure resting levels and mental stress responses.

    abstract::BACKGROUND: Blood pressure measurements taken in the clinic or laboratory are assumed to generalize to the world outside. This is true both of casual blood pressure measurements and of changes in blood pressure responses to stress. Such generalizability is crucial to the usefulness of blood pressure measurements as pr...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Gerin W,Christenfeld N,Pieper C

    更新日期:1996-12-01 00:00:00

  • Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). PATIENTS AND METHODS:In 33 patients aged 32-79 years, BP measurements were performed alternately u...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000216

    authors: Beime B,Deutsch C,Krüger R,Zimmermann E,Bramlage P

    更新日期:2016-12-01 00:00:00

  • Taking blood pressure -- no laughing matter!

    abstract:BACKGROUND:Humour is used commonly to relax subjects when their blood pressure is being measured. However the short-term effect of laughter on blood pressure is not described. METHODS:Sixteen normotensive volunteers had blood pressure measured using a validated automated oscillometric sphygmomanometric device (Omron 7...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200504000-00010

    authors: McMahon C,Mahmud A,Feely J

    更新日期:2005-04-01 00:00:00

  • Validation protocols for blood pressure-measuring devices: status quo and development needs.

    abstract::Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000150

    authors: Beime B,Deutsch C,Gomez T,Zwingers T,Mengden T,Bramlage P

    更新日期:2016-02-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • The impact of the day of the week on home blood pressure: the Finn-Home study.

    abstract:OBJECTIVE:The impact of the day of the week on home blood pressure (BP) level and day-to-day BP profile is unknown. Our objectives were to examine (i) how the initial measurement day of the week affects 3-day and 7-day mean home BP and (ii) the BP variation between different days of the week. PARTICIPANTS AND METHODS:...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000156

    authors: Juhanoja EP,Puukka PJ,Johansson JK,Niiranen TJ,Jula AM

    更新日期:2016-04-01 00:00:00

  • The Maxi Stabil 3: validation of an aneroid device according to a modified British Hypertension Society protocol.

    abstract:BACKGROUND:Measuring blood pressure with mercury-independent alternatives is rapidly gaining attention. Mercury will be phased out of clinical use as a result of environmental, health and safety concerns and it is of vital importance that any alternative to mercury has to be of a recognized standard. We assessed the ac...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200304000-00005

    authors: Reinders A,Jones CR,Cuckson AC,Shennan AH

    更新日期:2003-04-01 00:00:00