Abstract:
:OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various arm circumferences and ranges of blood pressure. Resting casual blood pressure was 135 +/- 24/76 +/- 14 mmHg (mean +/- SD). For each subject nine readings of the 90217 device were compared with auscultatory reference readings of two independent observers who used a dual stethoscope. The measurements were performed with subjects standing, sitting and supine. The manual reference readings were alternated with the 90217 monitor's readings. RESULTS: Average differences between manual (average of recordings by two clinicians) and automated readings were -5 +/- 4.3/0.6 +/- 4.6 mmHg (seated), 0.0 +/- 6.0/-1.8 +/- 4.7 mmHg (standing) and -1.6 +/- 5.1/-0.7 +/- 5.1 mmHg (supine).CONCLUSIONS: The device meets the Association for the Advancement of Medical Instrumentation's standard. Comparing the results with the modified BHS protocol, it was found that the device earned the highest BHS grade of 'A' both for systolic and for diastolic blood pressures.
journal_name
Blood Press Monitjournal_title
Blood pressure monitoringauthors
Baumgart P,Kamp Jsubject
Has Abstractpub_date
1998-10-01 00:00:00pages
303-307issue
5eissn
1359-5237issn
1473-5725journal_volume
3pub_type
杂志文章abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e3280b083a7
更新日期:2007-06-01 00:00:00
abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000344
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:To determine blood pressure (BP) reassessment rates and to describe the evaluation and outpatient referral rates of elderly emergency department (ED) patients with elevated BP. METHODS:This was a retrospective cohort of patients who were at least 60 years, presented with a systolic BP of at least 140 mmHg o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,多中心研究
doi:10.1097/MBP.0b013e328332fd40
更新日期:2009-12-01 00:00:00
abstract::BACKGROUND: The lack of significant correlation between sodium consumption and blood pressure in a population has tentatively been explained by individual differences in salt sensitivity. Previously we have shown that one-third of essential hypertensived patients respond to a salt load of 9 g daily for 5 days with an ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-02-01 00:00:00
abstract:BACKGROUND:Obstructive sleep apnea-hypopnea syndrome (OSAHS) is common in people with hypertension and cardiac rhythm disorder. The objectives of this study were to determine the effect of short-term continuous positive airway pressure (CPAP) on blood pressure (BP) and cardiac rhythm in Chinese patients with moderate t...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000324
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1097/00126097-200104000-00005
更新日期:2001-04-01 00:00:00
abstract:BACKGROUND:The pathogenesis of dialysis-induced hypotension (DIH) is multifactorial and may include increased aortic stiffness. This study was undertaken to determine aortic elastic properties in patients undergoing hemodialysis with and without DIH, and to assess the effects of DIH on mortality. METHODS:Aortic stiffn...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,多中心研究
doi:10.1097/MBP.0b013e3282f13f75
更新日期:2008-04-01 00:00:00
abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200110000-00005
更新日期:2001-10-01 00:00:00
abstract:BACKGROUND:Guidelines for office blood pressure reading techniques do not warn us about the possibility that patients may clench their fist during cuff-inflation. It is unknown how often patients do this, and what effect it has on measured blood pressure readings. DESIGN AND METHODS:We registered double blood pressure...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200206000-00001
更新日期:2002-06-01 00:00:00
abstract:BACKGROUND:Patients and doctors often use home blood pressure monitoring (HBPM) to assess the control of hypertension. Despite its popularity there has always been some uncertainty with regard to its accuracy, reliability, reproducibility, and comparability. Although there are pre-market HBPM standards of accuracy, the...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-199904010-00007
更新日期:1999-02-01 00:00:00
abstract::OBJECTIVES: To compare clinic and am measurements of blood pressure in old patients with isolated systolic hypertension and their reproducibilities. PATIENTS: In total 610 patients aged >/= 60 years with isolated systolic hypertension detected by clinic measurement were monitored during the placebo run-in phase of the...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/00126097-200308000-00007
更新日期:2003-08-01 00:00:00
abstract:BACKGROUND:Waist circumference (WC) and related anthropometric indices have been recognized as useful measures of abdominal obesity. However, little is known about the association of waist-to-sitting-height ratio (WSHtR) with obesity and elevated blood pressure (BP). PARTICIPANTS AND METHODS:Data for this study were o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000154
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. DESIGN:The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200208000-00006
更新日期:2002-08-01 00:00:00
abstract::Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/MBP.0000000000000150
更新日期:2016-02-01 00:00:00
abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/mbp.0b013e3280fb2792
更新日期:2007-08-01 00:00:00
abstract:OBJECTIVE:When calculating the difference between alternating auscultatory reference standard (ARS) and the automated device-under-test (DUT) blood pressure (BP) measurements, the European Society of Hypertension International Protocol (ESH-IP) allows investigators to choose the closest ARS value to the DUT value, rath...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000454
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVE:Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impract...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000133
更新日期:2015-08-01 00:00:00
abstract::Hypertension is a highly common condition with well-established adverse consequences. Ambulatory blood pressure monitoring has repeatedly been shown to better predict cardiovascular outcomes and mortality, compared to single office visit blood pressure. Non-dipping of sleep-time blood pressure is an independent marker...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/MBP.0000000000000426
更新日期:2020-04-01 00:00:00
abstract:AIM:Blood pressure (BP), a key vital sign, monitors general health. Oscillometric devices are increasingly used for measurement, although their accuracy continues to be critically debated. A functional block diagram is used to review the components that affect accuracy. METHODS:A block diagram is presented covering th...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/MBP.0b013e32835026b0
更新日期:2012-04-01 00:00:00
abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200306000-00006
更新日期:2003-06-01 00:00:00
abstract:OBJECTIVE:The impact of the day of the week on home blood pressure (BP) level and day-to-day BP profile is unknown. Our objectives were to examine (i) how the initial measurement day of the week affects 3-day and 7-day mean home BP and (ii) the BP variation between different days of the week. PARTICIPANTS AND METHODS:...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000156
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVE:The independent prognostic significance of ambulatory blood pressure variability in the elderly is incompletely clear. We investigated the prognostic value of average real variability of 24-hour blood pressure in elderly treated hypertensive patients. METHODS:The occurrence of a combined end-point including ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000381
更新日期:2019-08-01 00:00:00
abstract:BACKGROUND:Manufacturer-supplied blood pressure (BP) cuffs are part of the automatic oscillometric BP devices algorithm. MATERIALS AND METHODS:This study assessed the differences in BP values using the Omron HEM 907-XL (Omron) device with two types of cuffs: the Baum cuff (BC) and the supplied Omron cuff (OC). A sampl...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0000000000000208
更新日期:2016-12-01 00:00:00
abstract::Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national s...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000081
更新日期:2015-02-01 00:00:00
abstract::The inherent variability of activity and the awake-sleep cycle creates changes in hemodynamics that may influence the outcome of a variety of cardiovascular disorders. Recently, data suggest that increased variability of blood pressure may promote excessive hypertensive target organ disease. Several epidemiologic stud...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:
更新日期:1999-01-01 00:00:00
abstract:BACKGROUND:Background Ambulatory blood pressure monitoring (ABPM) has been shown to be more representative of blood pressure levels in adult patients than are casual measurements of blood pressure. OBJECTIVE:To evaluate, by means of ABPM, the behavior of blood pressure in children with chronic renal failure submitted ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1999-10-01 00:00:00
abstract::OBJECTIVE: To determine whether the evening intake of 5 mg melatonin affects 24 h arterial blood pressure and heart-rate profiles. METHODS: Twenty-one young normotensive subjects were administered placebo or melatonin for 4 weeks, according to a cross-over double-blind design, and were subjected to ambulatory blood pr...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1997-04-01 00:00:00
abstract::OBJECTIVE: To investigate whether blood pressure monitoring is reproducible. DESIGN: Reproducibility of ambulatory blood pressure monitoring data was assessed by means of traditional and relatively new statistical methods, namely correlation coefficients, regression analysis and agreement analysis. METHODS: Ninety-one...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-04-01 00:00:00
abstract::METHODS: Autonomic nervous function was evaluated by means of power spectral analysis of heart rate and blood pressure variability in dipper (n = 10) and non-dipper (n = 9) essential hypertensive subjects during sleep. The non-dipper subjects were defined as those in whom the nocturnal decrease in blood pressure was <...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1996-10-01 00:00:00