Repeatability of blood pressure measurements during treadmill exercise.

Abstract:

OBJECTIVE:Blood pressure measurements during exercise are difficult to obtain but are used widely in clinical practice. The objective of this study was to investigate the repeatability of blood pressure measurements and gas exchange parameters during treadmill exercise. METHODS:Participants were 10 healthy and nonsmoking men (age: 26.1 ± 3.6 years). Each participant performed two identical treadmill tests until exhaustion. The blood pressure was measured in the right arm before, at 4-min intervals during and just after the exercise test. Oxygen consumption, carbon dioxide production and ventilation were measured continuously breath-by-breath. Blood lactic acid concentration was measured repeatedly. RESULTS:We found that blood pressure measurements during treadmill exercise are difficult to obtain. Systolic blood pressure increases with the exercise time. Diastolic blood pressure remains constant throughout the incrementing exercise test. Systolic blood pressure measurements are more repeatable than those of diastolic blood pressure measurements. We found that maximal oxygen consumption, obtained by an incrementing treadmill test, is highly repeatable and more repeatable than submaximal exercise parameters. CONCLUSION:Blood pressure monitoring during exercise testing may provide important clinical information that could aid in identifying patients at risk of developing chronic hypertension.

journal_name

Blood Press Monit

authors

Instebø A,Helgheim V,Greve G

doi

10.1097/MBP.0b013e328351de5c

subject

Has Abstract

pub_date

2012-04-01 00:00:00

pages

69-72

issue

2

eissn

1359-5237

issn

1473-5725

journal_volume

17

pub_type

临床试验,杂志文章
  • Do we undertreat hypertensive smokers? A comparison between smoking and non-smoking hypertensives.

    abstract::The acute effect of smoking is a rise in blood pressure and heart rate. Nevertheless, in several epidemiologic studies, smokers tend to have a slightly lower office blood pressure than non-smokers. We studied the 24 h ambulatory blood pressure consecutively in hypertensive smokers (> or = 10 cigarettes per day, n = 26...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200010000-00004

    authors: Bang LE,Buttenschøn L,Kristensen KS,Svendsen TL

    更新日期:2000-10-01 00:00:00

  • Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension.

    abstract:OBJECTIVE:The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution. METHODS:Blood pressure indices, blood pressure loads and standard deviation scores were c...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32832ce11e

    authors: Jones DP,Richey PA,Alpert BS

    更新日期:2009-06-01 00:00:00

  • Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346d715

    authors: Yi J,Wan Y,Pan F,Yu X,Zhao H,Shang F,Xu Y

    更新日期:2011-08-01 00:00:00

  • Effects of salt loading and potassium supplement on the circadian blood pressure profile in salt-sensitive Chinese patients.

    abstract:BACKGROUND AND OBJECTIVE:Salt-sensitive (SS) patients more frequently showed a nondipper blood pressure pattern and were associated with more serious target organ damage than non-SS patients. We aimed to investigate whether potassium supplement can improve the blunted nocturnal blood pressure fall in SS patients expose...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000276

    authors: Guo TS,Dai Y,Ren KY,Mu JJ,Ren J,Wang D,Wang Y,Chu C,Li Y,Yuan ZY

    更新日期:2017-12-01 00:00:00

  • Relationship between waking-sleep blood pressure and catecholamine changes in African-American and European-American women.

    abstract:BACKGROUND:A blunted decline in waking to sleep blood pressure (BP) is more common in African-American (AA) than European-American (EA) women. The causes of reduced BP 'dipping' in AA women are not known, although several factors including ethnic differences in catecholamine sensitivity have been suggested. The purpose...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3283078f45

    authors: van Berge-Landry HM,Bovbjerg DH,James GD

    更新日期:2008-10-01 00:00:00

  • The effect of crossing legs on blood pressure.

    abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3280b083a7

    authors: Adiyaman A,Tosun N,Elving LD,Deinum J,Lenders JW,Thien T

    更新日期:2007-06-01 00:00:00

  • Effect of fasting on 24-h blood pressure values of individuals with no previous history of hypertension.

    abstract:OBJECTIVE:We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. PATIENTS AND METHODS:This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage chang...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0000000000000244

    authors: Seker A,Demirci H,Ocakoglu G,Aydin U,Ucar H,Yildiz G,Yaman O

    更新日期:2017-10-01 00:00:00

  • Masked hypertension, a review of the literature.

    abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/mbp.0b013e3280fb2792

    authors: Verberk WJ,Thien T,de Leeuw PW

    更新日期:2007-08-01 00:00:00

  • Ambulatory blood pressure monitoring in pediatric end-stage renal disease: chronic dialysis and transplantation.

    abstract::Hypertension is highly prevalent in pediatric patients with end-stage renal disease (ESRD). Ambulatory blood pressure monitoring (ABPM) has been used to characterize the altered circadian blood pressure patterns in ESRD in order to improve our understanding of the blood pressure dysregulation that occurs in these chil...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Sorof JM

    更新日期:1999-06-01 00:00:00

  • Identification of subjects with white-coat hypertension and persistently normal ambulatory blood pressure.

    abstract::OBJECTIVE: To assess the spontaneous changes in clinic blood pressure, ambulatory blood pressure (ABP) and left ventricular structure in untreated subjects with white-coat hypertension (WCH). DESIGN: A prospective observational study. PATIENTS AND METHODS: In 83 untreated subjects with WCH, 24 h non-invasive ABP monit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Verdecchia P,Schillaci G,Borgioni C,Ciucci A,Gattobigio R,Sacchi N,Guerrieri M,Comparato E,Porcellati C

    更新日期:1996-06-01 00:00:00

  • Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians.

    abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000130223.80658.3d

    authors: Staal EM,Nygård OK,Omvik P,Gerdts E

    更新日期:2004-06-01 00:00:00

  • Sensitivity, specificity, and predictive values of a forearm blood pressure measurement method in severe obesity.

    abstract::For blood pressure assessment, it has been reported that forearm blood pressure measurement appears to be as valid as an upper-arm blood pressure measurement method in individuals with severe obesity when correlated to the intra-arterial method, considered as the gold standard. Sensitivity, specificity, and predictive...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000097

    authors: Leblanc MÈ,Cloutier L,Poirier P

    更新日期:2015-04-01 00:00:00

  • The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    abstract:OBJECTIVE:To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. PARTICIPANTS AND METHODS:This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000141

    authors: Shangguan Q,Wu Y,Xu J,Su H,Li J,Hong K,Cheng X

    更新日期:2015-12-01 00:00:00

  • Reproducibility of ambulatory blood pressure measurements in essential hypertension.

    abstract:BACKGROUND:Data on the reproducibility of serial measurements of ambulatory blood pressure in hypertensive patients are lacking. The purpose of this study was to examine (1) the reproducibility of four consecutive ambulatory blood pressure measurements, and (2) the reproducibility of nocturnal falls in blood pressure i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200102000-00007

    authors: Zakopoulos NA,Nanas SN,Lekakis JP,Vemmos KN,Kotsis VT,Pitiriga VC,Stamatelopoulos SF,Moulopoulos SD

    更新日期:2001-02-01 00:00:00

  • Serum copeptin levels in predicting nondippers in newly diagnosed hypertension.

    abstract:OBJECTIVES:The nondipper pattern in hypertension is associated with worse cardiovascular outcomes. In this study, we hypothesized that high copeptin levels could predict nondippers among hypertensive patients and investigated the associations between copeptin levels and nondipper pattern in newly diagnosed hypertensive...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000123

    authors: Uzun F,Biyik I,Akturk IF,Yalcin AA,Erturk M,Oner E,Kalkan AK,Yalcin B,Atmaca H

    更新日期:2015-08-01 00:00:00

  • The effects of various definitions of dipping and daytime and night-time on the characterization of 24 h profiles of blood pressure.

    abstract:BACKGROUND:Ambulatory blood pressure monitoring allows characterization of the patient's average blood pressure load as well as various profiles of blood pressure. Results from clinical studies suggest that dippers (patients whose blood pressures decrease during night-time) have a lower risk of cardiovascular events th...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200002000-00004

    authors: Butkevich A,Phillips RA,Sheinart KF,Tuhrim S

    更新日期:2000-02-01 00:00:00

  • Dialysis-induced hypotension is associated with impaired aortic elasticity in patients undergoing chronic hemodialysis.

    abstract:BACKGROUND:The pathogenesis of dialysis-induced hypotension (DIH) is multifactorial and may include increased aortic stiffness. This study was undertaken to determine aortic elastic properties in patients undergoing hemodialysis with and without DIH, and to assess the effects of DIH on mortality. METHODS:Aortic stiffn...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e3282f13f75

    authors: Duman D,Demirtunc R,Erdogan B,Sahin GM,Karadag B

    更新日期:2008-04-01 00:00:00

  • Circadian variation of blood pressure and the assessment of antihypertensive therapy.

    abstract::The inherent variability of activity and the awake-sleep cycle creates changes in hemodynamics that may influence the outcome of a variety of cardiovascular disorders. Recently, data suggest that increased variability of blood pressure may promote excessive hypertensive target organ disease. Several epidemiologic stud...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: White WB

    更新日期:1999-01-01 00:00:00

  • Prognostic significance of self-measurements of blood pressure.

    abstract:BACKGROUND:Self-measurements of blood pressure may offer some advantage in diagnostic and therapeutic evaluation and in management of patients. However, the most important limitation of self-measurement is that there are limited data available about the prognostic value of this information. RESULTS:Authors of several ...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Imai Y,Poncelet P,DeBuyzere M,Padfield PL,Van Montfrans GA

    更新日期:2000-04-01 00:00:00

  • Prediction of strokes versus cardiac events by ambulatory monitoring of blood pressure: results from an international database.

    abstract::We performed this study to elucidate the role of nighttime versus daytime ambulatory blood pressure in predicting stroke and cardiac events. The International Collaborative Study of the Prognostic Utility of ABPM, which includes prospective cohort studies of ambulatory blood pressure monitoring (ABPM) from seven sites...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e3282411a12

    authors: Pickering T,Schwartz J,Verdecchia P,Imai Y,Kario K,Eguchi K,Pierdomenico S,Ohkubo T,Wing L

    更新日期:2007-12-01 00:00:00

  • Impact of choosing the closest rather than the mean auscultatory blood pressure value on the European Society of Hypertension International Protocol device validation results.

    abstract:OBJECTIVE:When calculating the difference between alternating auscultatory reference standard (ARS) and the automated device-under-test (DUT) blood pressure (BP) measurements, the European Society of Hypertension International Protocol (ESH-IP) allows investigators to choose the closest ARS value to the DUT value, rath...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000454

    authors: Padwal R,Wood PW,McLean D,Ringrose JS

    更新日期:2020-08-01 00:00:00

  • Ambulatory blood pressure variation in normotensive subjects in relation to the sitting or standing position.

    abstract:OBJECTIVE:To evaluate the physiological variations in arterial blood pressure in normotensive subjects during activity and in relation to the sitting or lying position. METHODS:The subjects were 30 healthy volunteers who were normotensive and receiving no treatment. Blood pressure was measured using the validated moni...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200006000-00005

    authors: Mallion JM,Mouret S,Baguet JP,Maître A,Quesada JL,De Gaudemaris R

    更新日期:2000-06-01 00:00:00

  • Sympathetic peripheral vasoconstriction may be measured using an artifact of the Finapres volume clamp technique.

    abstract:OBJECTIVES:The objective of this work was to test the hypothesis that the Finapres underestimates blood pressure during sympathetic peripheral vasoconstriction. METHODS:Measurements were made simultaneously with two Finapres devices and one radial artery tonometer during the onset of periodic lower body negative press...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e3282c9acc3

    authors: Birch AA

    更新日期:2007-10-01 00:00:00

  • Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards

    abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328330c873

    authors: Polo Friz H,Facchetti R,Primitz L,Beltrame L,Galbiati V,Ricioppo A,Bombelli M,Sega R

    更新日期:2009-10-01 00:00:00

  • Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32834b4431

    authors: Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C

    更新日期:2011-10-01 00:00:00

  • Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing.

    abstract:OBJECTIVE:The Welch Allyn Pro BP 2000, an automated sphygmomanometer, was subjected to ANSI/AAMI/ISO testing. PATIENTS AND METHODS:The protocol used was the same-arm sequential procedure described in the ANSI/AAMI/ISO 2013 Standard. Eight-eight (53 adults and 35 children aged 3-12 years old) patients completed testing...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000350

    authors: Alpert BS

    更新日期:2018-12-01 00:00:00

  • Accuracy of the WatchBP O3 device for ambulatory blood pressure monitoring according to the new criteria of the ISO81060-2 2018 protocol.

    abstract:OBJECTIVE:The aim of the study was to determine the accuracy of the Microlife WatchBP O3 monitor for ambulatory blood pressure (BP) measurement according to the new ISO81060-2 2018 protocol. METHODS:The WatchBP O3 was first tested in 97 subjects from the general population (mean age, 71.3 years; 48 men) using four cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000459

    authors: Fania C,Lazzaretto I,Fontana U,Palatini P

    更新日期:2020-10-01 00:00:00

  • Rationale and design of HOMED-BP Study: hypertension objective treatment based on measurement by electrical devices of blood pressure study.

    abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00126097-200202000-00016

    authors: Fujiwara T,Nishimura T,Ohkuko T,Imai Y,HOMED-BP Study Group.

    更新日期:2002-02-01 00:00:00

  • Percentiles of waist-to-sitting-height ratio and its relationship with obesity and elevated blood pressure among children and adolescents in Shandong, China.

    abstract:BACKGROUND:Waist circumference (WC) and related anthropometric indices have been recognized as useful measures of abdominal obesity. However, little is known about the association of waist-to-sitting-height ratio (WSHtR) with obesity and elevated blood pressure (BP). PARTICIPANTS AND METHODS:Data for this study were o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000154

    authors: Zhang YX,Zhao JS,Chu ZH

    更新日期:2016-02-01 00:00:00

  • Brachial or wrist blood pressure in obese patients: which is the best?

    abstract:OBJECTIVE:Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS:We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mann...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3282fd16e3

    authors: de Senarclens O,Feihl F,Giusti V,Engelberger RP,Rodieux F,Gomez P,Liaudet L,Waeber B

    更新日期:2008-06-01 00:00:00