Sensitivity, specificity, and predictive values of a forearm blood pressure measurement method in severe obesity.

Abstract:

:For blood pressure assessment, it has been reported that forearm blood pressure measurement appears to be as valid as an upper-arm blood pressure measurement method in individuals with severe obesity when correlated to the intra-arterial method, considered as the gold standard. Sensitivity, specificity, and predictive values for the presence of systemic hypertension in 25 severely obese patients from 352 blood pressure measurements were calculated. The sensitivity (0.98) and the positive predictive value (0.93) for hypertension on forearm blood pressure measurements are excellent, indicating that the forearm approach is a promising alternative to systemic hypertension diagnosis in severe obesity.

journal_name

Blood Press Monit

authors

Leblanc MÈ,Cloutier L,Poirier P

doi

10.1097/MBP.0000000000000097

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

79-82

issue

2

eissn

1359-5237

issn

1473-5725

pii

00126097-201504000-00005

journal_volume

20

pub_type

杂志文章
  • Effects of race and sex on blood pressure and hemodynamic stress response as a function of the menstrual cycle.

    abstract::OBJECTIVE: To examine the influence of race and sex on responses to cardiovascular stress during two menstrual cycle phases. METHODS: Subjects were exposed to two stressors, a mirror star-tracing task and a speaking task. Blood pressure, heart rate, and impedance cardiography measures of reactivity were recorded. Wome...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Ahwal WN,Mills PJ,Kalshan DA,Nelesen RA

    更新日期:1997-08-01 00:00:00

  • Circadian variation of blood pressure and the assessment of antihypertensive therapy.

    abstract::The inherent variability of activity and the awake-sleep cycle creates changes in hemodynamics that may influence the outcome of a variety of cardiovascular disorders. Recently, data suggest that increased variability of blood pressure may promote excessive hypertensive target organ disease. Several epidemiologic stud...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: White WB

    更新日期:1999-01-01 00:00:00

  • Ambulatory blood pressure monitoring in end-stage renal disease.

    abstract::BACKGROUND: Hypertension is responsible for substantial morbidity in end-stage renal disease. Ambulatory blood pressure monitoring has been used to understand the behavior of blood pressure in renal failure, especially during the interdialytic period for patients on hemodialysis. OBJECTIVE: To review the published dat...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Peixoto AJ,Sica DA

    更新日期:1997-12-01 00:00:00

  • Does the accuracy of blood pressure measurement correlate with hearing loss of the observer?

    abstract:OBJECTIVE:The auscultatory method is influenced by the hearing level of the observers. If the observer has hearing loss, it is possible to measure blood pressure inaccurately by misreading the Korotkoff sounds at systolic blood pressure (SBP) and diastolic blood pressure (DBP). Because of the potential clinical problem...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000016

    authors: Song S,Lee J,Chee Y,Jang DP,Kim IY

    更新日期:2014-02-01 00:00:00

  • White coat hypertension in children.

    abstract::Ambulatory blood pressure monitoring (ABPM) has become more widely used in the assessment of elevated blood pressure in children. The accurate diagnosis of white coat hypertension (WCH) is particularly important in children because detection of elevated blood pressure often results in expensive and invasive diagnostic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200008000-00001

    authors: Sorof JM

    更新日期:2000-08-01 00:00:00

  • Validation of TM-2655 oscillometric device for blood pressure measurement.

    abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000200484.49540.12

    authors: Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

    更新日期:2006-04-01 00:00:00

  • Beneficial response of blood pressure to short-term continuous positive airway pressure in Chinese patients with obstructive sleep apnea-hypopnea syndrome.

    abstract:BACKGROUND:Obstructive sleep apnea-hypopnea syndrome (OSAHS) is common in people with hypertension and cardiac rhythm disorder. The objectives of this study were to determine the effect of short-term continuous positive airway pressure (CPAP) on blood pressure (BP) and cardiac rhythm in Chinese patients with moderate t...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000324

    authors: Wang X,Qiu J,Wang Y,Cai Z,Lu X,Li T

    更新日期:2018-08-01 00:00:00

  • Automated office blood pressure - being alone and not location is what matters most.

    abstract:OBJECTIVE:Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impract...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000133

    authors: Armstrong D,Matangi M,Brouillard D,Myers MG

    更新日期:2015-08-01 00:00:00

  • Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

    abstract::Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary cont...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Burnier M

    更新日期:2000-01-01 00:00:00

  • Accuracy of the Microlife large-extra large-sized cuff (32-52 cm) coupled to an automatic oscillometric device.

    abstract::To determine the accuracy of the large-extra large-sized (L-XL) cuff (32-52 cm) coupled to a Microlife WatchBP Office ABI blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The L-XL cuff tested in this study is designed to provide...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328344c73c

    authors: Masiero S,Saladini F,Benetti E,Palatini P

    更新日期:2011-04-01 00:00:00

  • Frequency of spontaneous fist clenching during routine blood pressure measurements and its effect on measurement accuracy.

    abstract:BACKGROUND:Guidelines for office blood pressure reading techniques do not warn us about the possibility that patients may clench their fist during cuff-inflation. It is unknown how often patients do this, and what effect it has on measured blood pressure readings. DESIGN AND METHODS:We registered double blood pressure...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200206000-00001

    authors: Smulders YM,Godfried MH,van Montfrans GA

    更新日期:2002-06-01 00:00:00

  • Reliability of home blood pressure monitoring: in the context of validation and accuracy.

    abstract:OBJECTIVE:Home blood pressure (BP) monitoring offers clinically relevant information enriched with more abundant data. However, there are few studies addressing the reliability of home BP devices and the quality of its data. This study aimed to evaluate the current status of home BP devices in terms of validation and a...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000121

    authors: Jung MH,Kim GH,Kim JH,Moon KW,Yoo KD,Rho TH,Kim CM

    更新日期:2015-08-01 00:00:00

  • Feasibility of oscillometric aortic pressure and stiffness assessment using the VaSera VS-1500: comparison with a common tonometric method.

    abstract:OBJECTIVES:A number of operator-independent oscillometric devices to measure hemodynamics and arterial stiffness became available recently, but some and in particular VaSera VS-1500 do not provide estimates of aortic pressures and aortic pulse wave velocity (aPWV). The aim of this work was the retrospective application...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000137

    authors: Endes S,Bachler M,Li Y,Mayer C,Hanssen H,Hametner B,Schmidt-Trucksäss A,Wassertheurer S

    更新日期:2015-10-01 00:00:00

  • Effects of the angiotensin II receptor blockers telmisartan versus valsartan in combination with hydrochlorothiazide: a large, confirmatory trial.

    abstract::In 2004-2005, the antihypertensive effects of telmisartan 80 mg versus valsartan 160 mg combined with hydrochlorothiazide 25 mg were assessed in a large placebo-controlled trial in patients with stages 1 and 2 hypertension and demonstrated that both agents were highly effective in lowering blood pressure (BP) compared...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e3282f3859d

    authors: White WB,Murwin D,Chrysant SG,Koval SE,Davidai G,Guthrie R

    更新日期:2008-02-01 00:00:00

  • Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients: effect of continuous positive airway pressure.

    abstract:INTRODUCTION:Seventeen male patients with severe obstructive sleep apnea syndrome (OSAS; apnea-hypopnea index>30/h) were monitored by polysomnography in the sleep lab before and after about 8 weeks of continuous positive airway pressure (CPAP). Twelve of the patients were hypertensive, but treated by antihypertensive d...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000173

    authors: Lemmer B,Scholtze J,Schmitt J

    更新日期:2016-06-01 00:00:00

  • Evaluation, management, and referral of elderly emergency department patients with elevated blood pressure.

    abstract:OBJECTIVES:To determine blood pressure (BP) reassessment rates and to describe the evaluation and outpatient referral rates of elderly emergency department (ED) patients with elevated BP. METHODS:This was a retrospective cohort of patients who were at least 60 years, presented with a systolic BP of at least 140 mmHg o...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e328332fd40

    authors: Baumann BM,Cienki JJ,Cline DM,Egging D,Lehrmann JF,Tanabe P

    更新日期:2009-12-01 00:00:00

  • Ambulatory blood pressure monitoring in pediatric end-stage renal disease: chronic dialysis and transplantation.

    abstract::Hypertension is highly prevalent in pediatric patients with end-stage renal disease (ESRD). Ambulatory blood pressure monitoring (ABPM) has been used to characterize the altered circadian blood pressure patterns in ESRD in order to improve our understanding of the blood pressure dysregulation that occurs in these chil...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Sorof JM

    更新日期:1999-06-01 00:00:00

  • The Maxi Stabil 3: validation of an aneroid device according to a modified British Hypertension Society protocol.

    abstract:BACKGROUND:Measuring blood pressure with mercury-independent alternatives is rapidly gaining attention. Mercury will be phased out of clinical use as a result of environmental, health and safety concerns and it is of vital importance that any alternative to mercury has to be of a recognized standard. We assessed the ac...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200304000-00005

    authors: Reinders A,Jones CR,Cuckson AC,Shennan AH

    更新日期:2003-04-01 00:00:00

  • Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs.

    abstract::Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national s...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000081

    authors: Neuhauser HK,Ellert U,Thamm M,Adler C

    更新日期:2015-02-01 00:00:00

  • Intense aerobic exercise lowers blood pressure in individuals with metabolic syndrome taking antihypertensive medicine.

    abstract:OBJECTIVE:There is a growing tendency for physicians to prescribe exercise in accordance with the 'exercise is medicine' global health initiative. However, the exercise-pharmacologic interactions for controlling blood pressure are not well described. Our purpose was to study whether angiotensin II receptor type 1 block...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000328

    authors: Ramirez-Jimenez M,Fernandez-Elias V,Morales-Palomo F,Ortega JF,Mora-Rodriguez R

    更新日期:2018-10-01 00:00:00

  • Hypertension in psoriasis patients: based on office and ambulatory blood pressure measurement.

    abstract:OBJECTIVE:Psoriasis is a chronic inflammatory disorder, which is associated with high risk of metabolic comorbidities. Hypertension (HTN) is among the most common and serious associations. In this study, we aimed to evaluate HTN in psoriatic patients through office and ambulatory blood pressure monitoring (ABPM). MATE...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000489

    authors: Abedini R,Najafi MT,Azizpour A,Nasimi M,Darreshiri M,Teymourpour A

    更新日期:2020-12-01 00:00:00

  • Clinical features, anthropometric characteristics, and racial influences on the 'white-coat effect' in a single-centre cohort of 1553 consecutive subjects undergoing routine ambulatory blood pressure monitoring.

    abstract:BACKGROUND:Patients with high office blood pressures but relatively normal readings during daytime ambulatory monitoring have been the subject of much investigation and debate. This clinical finding in part depends on an alerting reaction to the circumstances of the clinical measurement, often described as the 'white-c...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Gualdiero P,Niebauer J,Addison C,Clark SJ,Coats AJ

    更新日期:2000-04-01 00:00:00

  • Effects of salt loading and potassium supplement on the circadian blood pressure profile in salt-sensitive Chinese patients.

    abstract:BACKGROUND AND OBJECTIVE:Salt-sensitive (SS) patients more frequently showed a nondipper blood pressure pattern and were associated with more serious target organ damage than non-SS patients. We aimed to investigate whether potassium supplement can improve the blunted nocturnal blood pressure fall in SS patients expose...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000276

    authors: Guo TS,Dai Y,Ren KY,Mu JJ,Ren J,Wang D,Wang Y,Chu C,Li Y,Yuan ZY

    更新日期:2017-12-01 00:00:00

  • Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS:Systolic and diastolic b...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000261

    authors: Kang YY,Chen Q,Liu CY,Li Y,Wang JG

    更新日期:2017-08-01 00:00:00

  • Masked hypertension, a review of the literature.

    abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/mbp.0b013e3280fb2792

    authors: Verberk WJ,Thien T,de Leeuw PW

    更新日期:2007-08-01 00:00:00

  • Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing.

    abstract:OBJECTIVE:The Welch Allyn Pro BP 2000, an automated sphygmomanometer, was subjected to ANSI/AAMI/ISO testing. PATIENTS AND METHODS:The protocol used was the same-arm sequential procedure described in the ANSI/AAMI/ISO 2013 Standard. Eight-eight (53 adults and 35 children aged 3-12 years old) patients completed testing...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000350

    authors: Alpert BS

    更新日期:2018-12-01 00:00:00

  • The effect of crossing legs on blood pressure.

    abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3280b083a7

    authors: Adiyaman A,Tosun N,Elving LD,Deinum J,Lenders JW,Thien T

    更新日期:2007-06-01 00:00:00

  • Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect.

    abstract:OBJECTIVES:BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpT...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000189794.36230.a7

    authors: Culleton BF,McKay DW,Campbell NR

    更新日期:2006-02-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • Blood pressure measurement and the guidelines: a proposed new algorithm for the diagnosis of hypertension.

    abstract::Current hypertension guidelines continue to base management decisions on the office BP as recorded by mercury sphygmomanometry. The imminent disappearance of mercury from the workplace for environmental and safety reasons provides an opportunity to re-assess how a diagnosis of hypertension is made. There are now sever...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1097/00126097-200412000-00002

    authors: Myers MG

    更新日期:2004-12-01 00:00:00