Validation of TM-2655 oscillometric device for blood pressure measurement.

Abstract:

OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, systolic blood pressure range was 84-208 mmHg and diastolic blood pressure range was 48-120 mmHg. For each participant, three readings of TM-2655 were compared with sequential auscultatory measurements by two trained independent observers. The observers used a calibrated mercury sphygmomanometer and dual stethoscope. The results were graded according to the British Hypertension Society protocol 1993. RESULTS:The average difference between mercury sphygmomanometer and TM-2655 readings for systolic blood pressure was -1.0+5.2 mmHg (mean+/-SD) and for diastolic blood pressure -0.9+/-4.7 mmHg. The proportions of values agreeing to within 5, 10 and 15 mmHg were 72.5, 93.7 and 99.6% for systolic blood pressure and 78.8, 96.9 and 100% for diastolic blood pressure between the observers and the device (A/A British Hypertension Society grade). CONCLUSIONS:The TM-2655 device achieved British Hypertension Society grade A/A and therefore can be recommended for blood pressure measurement in an adult population.

journal_name

Blood Press Monit

authors

Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

doi

10.1097/01.mbp.0000200484.49540.12

subject

Has Abstract

pub_date

2006-04-01 00:00:00

pages

87-90

issue

2

eissn

1359-5237

issn

1473-5725

pii

00126097-200604000-00007

journal_volume

11

pub_type

杂志文章
  • Prognostic significance of self-measurements of blood pressure.

    abstract:BACKGROUND:Self-measurements of blood pressure may offer some advantage in diagnostic and therapeutic evaluation and in management of patients. However, the most important limitation of self-measurement is that there are limited data available about the prognostic value of this information. RESULTS:Authors of several ...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Imai Y,Poncelet P,DeBuyzere M,Padfield PL,Van Montfrans GA

    更新日期:2000-04-01 00:00:00

  • Is blunted heart rate decrease at night associated with prevalent organ damage in essential hypertension?

    abstract:AIM:The association between a blunted decrease in day–night heart rate and subclinical organ damage has not been investigated earlier in human hypertension. Therefore, we assessed such an association in a cohort of 658 untreated essential hypertensive patients. METHODS:All patients underwent procedures including cardi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/mbp.0b013e32834331fe

    authors: Cuspidi C,Meani S,Negri F,Valerio C,Sala C,Mancia G

    更新日期:2011-02-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • Long-term compliance with antihypertensive therapy: another facet of chronotherapeutics in hypertension.

    abstract::Despite improvements in the management of hypertension in the past several years and the numerous efficacious antihypertensive agents available to today's physician, nearly 70% of patients do not have their hypertension adequately controlled. Noncompliance with prescribed regimens appears to be one of the primary cont...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Burnier M

    更新日期:2000-01-01 00:00:00

  • An extended validation of the ScottCare 320 ambulatory blood pressure monitor: recommendations for clinical application.

    abstract:OBJECTIVES:The purpose of this study was to validate the ScottCare 320 ambulatory blood pressure monitor (ABPM) using both group-level and individual-level validation procedures. The group-level validation followed a modified protocol of the European Hypertension Society's validation protocol. The individual-level vali...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e32835f4fc7

    authors: Zawadzki MJ,Vandekar L,Smyth JM,Haas D,Gerin W

    更新日期:2013-06-01 00:00:00

  • Frequency of spontaneous fist clenching during routine blood pressure measurements and its effect on measurement accuracy.

    abstract:BACKGROUND:Guidelines for office blood pressure reading techniques do not warn us about the possibility that patients may clench their fist during cuff-inflation. It is unknown how often patients do this, and what effect it has on measured blood pressure readings. DESIGN AND METHODS:We registered double blood pressure...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200206000-00001

    authors: Smulders YM,Godfried MH,van Montfrans GA

    更新日期:2002-06-01 00:00:00

  • Aortic systolic pressure derived with different calibration methods: associations to brachial systolic pressure in the general population.

    abstract:BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of thi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000319

    authors: Wassertheurer S,Hametner B,Mayer CC,Hafez A,Negishi K,Papaioannou TG,Protogerou AD,Sharman JE,Weber T

    更新日期:2018-06-01 00:00:00

  • From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy.

    abstract::Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we highlighted the early...

    journal_title:Blood pressure monitoring

    pub_type: 传,历史文章,杂志文章

    doi:10.1097/MBP.0b013e3283380e1e

    authors: Stolarz-Skrzypek K,Thijs L,Wizner B,Richart T,Ogedegbe G,Li Y,Hansen TW,Boggia J,Kikuya M,Kuznetsova T,Wang J,Lurbe E,Imai Y,Kawecka-Jaszcz K,Staessen JA

    更新日期:2010-04-01 00:00:00

  • Accuracy of oscillometric blood pressure algorithms in healthy adults and in adults with cardiovascular risk factors.

    abstract:BACKGROUND:Fixed-ratio and slope-based algorithms are used to derive oscillometric blood pressure (BP). However, a paucity of published data exists assessing the accuracy of these methods. Our objective was to determine the accuracy of fixed-ratio and slope-based algorithms in healthy adults and in adults with cardiova...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000356

    authors: Padwal R,Jalali A,McLean D,Anwar S,Smith K,Raggi P,Ringrose JS

    更新日期:2019-02-01 00:00:00

  • Benazepril versus felodipine as supplement to bendroflumethiazide: evaluation by office and ambulatory blood pressure.

    abstract::OBJECTIVE: To compare a combination of a thiazide diuretic and an angiotensin converting enzyme inhibitor with a thiazide diuretic and a calcium antagonist. DESIGN: A double-blind randomized trial with subjects in two parallel groups administered either 10-20 mg benazepril once daily or 5-10 mg extended-release felodi...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Kristensen KS,Wiinberg N,Høegholm A,Kornerup HJ,Svendsen TL,Mølby L,Pindborg T,Nielsen PE

    更新日期:1998-04-01 00:00:00

  • Accuracy of the WatchBP O3 device for ambulatory blood pressure monitoring according to the new criteria of the ISO81060-2 2018 protocol.

    abstract:OBJECTIVE:The aim of the study was to determine the accuracy of the Microlife WatchBP O3 monitor for ambulatory blood pressure (BP) measurement according to the new ISO81060-2 2018 protocol. METHODS:The WatchBP O3 was first tested in 97 subjects from the general population (mean age, 71.3 years; 48 men) using four cuf...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000459

    authors: Fania C,Lazzaretto I,Fontana U,Palatini P

    更新日期:2020-10-01 00:00:00

  • Left ventricular hypertrophy and preclinical impaired glucose tolerance and diabetes mellitus contribute to abnormal left ventricular diastolic function in hypertensive patients.

    abstract:BACKGROUND:Impaired left ventricular diastolic function is not uncommon in patients with either diabetes mellitus or hypertension. This study was carried out to assess the contribution of left ventricular hypertrophy, high blood pressure, preclinical impaired glucose tolerance and diabetes mellitus to left ventricular ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000172710.82287.36

    authors: Salmasi AM,Rawlins S,Dancy M

    更新日期:2005-10-01 00:00:00

  • Ambulatory blood pressure monitoring in end-stage renal disease.

    abstract::BACKGROUND: Hypertension is responsible for substantial morbidity in end-stage renal disease. Ambulatory blood pressure monitoring has been used to understand the behavior of blood pressure in renal failure, especially during the interdialytic period for patients on hemodialysis. OBJECTIVE: To review the published dat...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Peixoto AJ,Sica DA

    更新日期:1997-12-01 00:00:00

  • Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    abstract:OBJECTIVE:To evaluate the accuracy of the YuWell YE680B oscillometric upper-arm blood pressure monitor for clinic and home blood pressure measurements in adults according to the American National Standards Institute/the Association for the Advancement of Medical Instrumentation/International Organization for Standardiz...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000405

    authors: Huang JF,Zhang W,Li Y,Wang JG

    更新日期:2019-12-01 00:00:00

  • Circadian variation of blood pressure and the assessment of antihypertensive therapy.

    abstract::The inherent variability of activity and the awake-sleep cycle creates changes in hemodynamics that may influence the outcome of a variety of cardiovascular disorders. Recently, data suggest that increased variability of blood pressure may promote excessive hypertensive target organ disease. Several epidemiologic stud...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: White WB

    更新日期:1999-01-01 00:00:00

  • Prediction of strokes versus cardiac events by ambulatory monitoring of blood pressure: results from an international database.

    abstract::We performed this study to elucidate the role of nighttime versus daytime ambulatory blood pressure in predicting stroke and cardiac events. The International Collaborative Study of the Prognostic Utility of ABPM, which includes prospective cohort studies of ambulatory blood pressure monitoring (ABPM) from seven sites...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0b013e3282411a12

    authors: Pickering T,Schwartz J,Verdecchia P,Imai Y,Kario K,Eguchi K,Pierdomenico S,Ohkubo T,Wing L

    更新日期:2007-12-01 00:00:00

  • Endothelial dysfunction predicted increased left atrial volume index in newly diagnosed nondiabetic hypertensive patients.

    abstract:BACKGROUND:Arterial hypertension is associated with cardiovascular morbidity and mortality. It was previously shown that left atrium volume increase associated with mortality and atherosclerotic heart disease. The aim of the present study was to demonstrate the value of endothelial dysfunction in predicting left atrium...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000419

    authors: Çetin M,Erdoğan T,Kiriş T,Aykan AÇ,Çinier G,Emlek N,Durak H,Kalaycioğlu E,Yilmaz AS

    更新日期:2020-04-01 00:00:00

  • Blood pressure measurement and the guidelines: a proposed new algorithm for the diagnosis of hypertension.

    abstract::Current hypertension guidelines continue to base management decisions on the office BP as recorded by mercury sphygmomanometry. The imminent disappearance of mercury from the workplace for environmental and safety reasons provides an opportunity to re-assess how a diagnosis of hypertension is made. There are now sever...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1097/00126097-200412000-00002

    authors: Myers MG

    更新日期:2004-12-01 00:00:00

  • Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200106000-00008

    authors: Wright JM,Mattu GS,Perry TL Jr,Gelferc ME,Strange KD,Zorn A,Chen Y

    更新日期:2001-06-01 00:00:00

  • Potential hypotensive effects of Umezu polyphenols: a 14-week community-based, double-masked and placebo-controlled trial.

    abstract:OBJECTIVE:To evaluate blood pressure (BP)-lowering effects of Umezu polyphenols, polyphenols contained in Japanese plums, in a community-based sample by double-masked and placebo-controlled design. METHODS:Seventy-two Japanese community-dwellers who were interested in prevention or control of their BP (preferably high...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000476

    authors: Takemura S,Yoshimasu K,Tsuno K,Kuroda M,Kishida K,Mitani T,Miyashita K

    更新日期:2020-12-01 00:00:00

  • The importance of the sympathetic nervous system and systolic hypertension in patients with hypertension: benefits in treating patients with increased cardiovascular risk.

    abstract::The sympathetic nervous system is intimately involved in both the origin and the perpetuation of the hypertensive state, although there is some debate as to its precise contribution to the long-term hypertensive condition. Catecholamines are leading candidates to be both the pressor mechanism that initiates the rise i...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200010002-00005

    authors: Sica DA

    更新日期:2000-01-01 00:00:00

  • A strategy utilizing ambulatory monitoring and home and clinic blood pressure measurements to optimize the safety evaluation of noncardiovascular drugs with potential for hemodynamic effects: a report from the SYNERGY trial.

    abstract:OBJECTIVE:The aim of this study was to perform a blood pressure (BP) safety evaluation in patients with an overactive bladder receiving solifenacin (an antimuscarinic agent), mirabegron (a β3-adrenoceptor agonist), or both compared with placebo in the SYNERGY trial. PATIENTS AND METHODS:Patients were randomized to rec...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/MBP.0000000000000320

    authors: Weber MA,Chapple CR,Gratzke C,Herschorn S,Robinson D,Frankel JM,Ridder AM,Stoelzel M,Paireddy A,van Maanen R,White WB

    更新日期:2018-06-01 00:00:00

  • Masked hypertension, a review of the literature.

    abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/mbp.0b013e3280fb2792

    authors: Verberk WJ,Thien T,de Leeuw PW

    更新日期:2007-08-01 00:00:00

  • Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    abstract:OBJECTIVE:Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pre...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32834b4431

    authors: Sipkens LM,Treskes K,Ariese-Beldman K,Veerman DP,Boer C

    更新日期:2011-10-01 00:00:00

  • Ambulatory blood pressure variation in normotensive subjects in relation to the sitting or standing position.

    abstract:OBJECTIVE:To evaluate the physiological variations in arterial blood pressure in normotensive subjects during activity and in relation to the sitting or lying position. METHODS:The subjects were 30 healthy volunteers who were normotensive and receiving no treatment. Blood pressure was measured using the validated moni...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200006000-00005

    authors: Mallion JM,Mouret S,Baguet JP,Maître A,Quesada JL,De Gaudemaris R

    更新日期:2000-06-01 00:00:00

  • 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?

    abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200110000-00005

    authors: Enström IE,Pennert KM

    更新日期:2001-10-01 00:00:00

  • A novel predictor of radial spasm: arterial stiffness.

    abstract:OBJECTIVE:In this study, we aimed to assess the relationship between radial artery spasm (RAS) and arterial stiffness (AS) measured by the oscillometric method. MATERIALS AND METHODS:A total of 123 consecutive patients scheduled for elective coronary angiography in a single default radial center were enrolled for the ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000340

    authors: Omaygenc MO,Karaca IO,Ibisoglu E,Günes HM,Kizilirmak F,Cakal B,Guler E,Barutcu I,Boztosun B

    更新日期:2018-10-01 00:00:00

  • The choice of threshold limits for pediatric ambulatory blood pressure monitoring influences clinical decisions.

    abstract:OBJECTIVES:Hypertension in children may be defined by blood pressure elevated above the 95th percentile according to sex and age. Population data for ambulatory blood pressure provide different age-related and sex-related threshold limits to office-derived data. We sought to determine whether, when using ambulatory blo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209085.55364.73

    authors: Kennedy SE,Mackie FE,Craig E,Kainer G

    更新日期:2006-06-01 00:00:00

  • Blood pressure in acute ischemic stroke and mortality: a study with noninvasive blood pressure monitoring.

    abstract:BACKGROUND:In acute ischemic stroke, a transient elevation of blood pressure is common; its significance and its relationship with the neurological outcome are still unclear. METHODS:In 71 consecutive patients with acute ischemic stroke, aged 25-94 years, admitted to our unit, we investigated the relationships between...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209077.23084.93

    authors: Sartori M,Benetton V,Carraro AM,Calò LA,Macchini L,Giantin V,Tosato F,Pessina AC,Semplicini A

    更新日期:2006-08-01 00:00:00

  • Rationale and design of HOMED-BP Study: hypertension objective treatment based on measurement by electrical devices of blood pressure study.

    abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00126097-200202000-00016

    authors: Fujiwara T,Nishimura T,Ohkuko T,Imai Y,HOMED-BP Study Group.

    更新日期:2002-02-01 00:00:00