Blood pressure assessment during resistance exercise: comparison between auscultation and Finapres.

Abstract:

OBJECTIVES:The objective of this study was to test whether the auscultatory method and Finapres provide similar readings for blood pressure response during two resistance exercise protocols of different intensities, and to gain some insight into whether auscultation can be used to monitor cardiovascular stress during resistance exercise. METHODS:Fourteen patients performed six and 15 maximum repetitions (six and 15, respectively) of one-leg knee extension on different days. Blood pressure (BP) was measured simultaneously with the two methods at rest and during the last repetition of the protocols. RESULTS:Neither the systolic blood pressure (SBP) nor the diastolic blood pressure (DBP) differed between methods, both at rest and at six maximum repetitions. Conversely, Finapres recorded higher systolic blood pressure at 15 maximum repetitions (168.8+/-21.7 mmHg) than auscultation (147.0+/-14.5 mmHg; P<0.001). In addition, the blood pressure values obtained by both methods in each exercise protocol (six and 15 maximum repetitions, respectively) were ranked in tertiles and also treated by the gamma (gamma) nonparametric correlation. We observed a high probability for patients to be ranked on the same tertile regardless of the method used, at both six maximum repetitions (SBP=0.80, DBP=0.97) and 15 maximum repetitions (SBP=0.88, DBP=0.92). High association between methods was also observed by simple regression when measurements taken at rest and at each intensity were analyzed altogether for both SBP (r=0.95, r adjusted=0.89) and DBP (r=0.79, r adjusted=0.62). CONCLUSION:Auscultation provides lower BP values than Finapres, especially at the end of a set including 15 maximum repetitions. The former, however, seems appropriate to assess the relative cardiovascular stress imposed by different protocols of resistance exercise.

journal_name

Blood Press Monit

authors

Polito MD,Farinatti PT,Lira VA,Nobrega AC

doi

10.1097/MBP.0b013e32809ef9f1

subject

Has Abstract

pub_date

2007-04-01 00:00:00

pages

81-6

issue

2

eissn

1359-5237

issn

1473-5725

pii

00126097-200704000-00004

journal_volume

12

pub_type

杂志文章
  • Acute effects of moderate-intensity and high-intensity exercise on hemodynamic and autonomic reactivity to the cold pressor test in young adults with excess body weight.

    abstract:OBJECTIVE:To investigate the effects of a single session of moderate-intensity and high-intensity interval exercise in cardiovascular reactivity to the cold pressor test in young adults with excess body weight. METHODS:Twenty-two subjects with excess body weight (23 ± 2 years; 30.0 ± 3.4 kg·m) performed three sessions...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000422

    authors: Meireles K,Peçanha T,Dias ARL,Souza KA,Araújo JA,Silva JS,Rezende DAN,Santos RJ,Cambri LT,Arsa G

    更新日期:2020-04-01 00:00:00

  • Quality of blood pressure phenotype in the Nigerian Population Research on Environment Gene and Health.

    abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000053

    authors: Odili AN,Ameh VO,Ogedengbe JO,Staessen JA

    更新日期:2014-08-01 00:00:00

  • Which is the correct term for blood pressure measurements taken at home?

    abstract::The terms 'self-blood pressure' and 'home blood pressure' are being used to describe measurements of blood pressure taken by the patients at home. However, home measurements are not always self-measurements, because these are often taken by the patients' relatives. There is little evidence on the effect of self-measur...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200308000-00007

    authors: Stergiou GS

    更新日期:2003-08-01 00:00:00

  • Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor.

    abstract::OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various ar...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Baumgart P,Kamp J

    更新日期:1998-10-01 00:00:00

  • Determination of accuracy in neonates for non-invasive blood pressure device using an improved algorithm.

    abstract:BACKGROUND:New software (SuperSTAT(R) algorithm) with enhancements aimed at shorter determination times was developed for a non-invasive blood pressure (NIBP) device and a clinical evaluation was conducted to verify accuracy. OBJECTIVE:To determine the accuracy of the new algorithm according to ANSI/AAMI SP10-1992 and...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200204000-00006

    authors: Nelson RM,Stebor AD,Groh CM,Timoney PM,Theobald KS,Friedman BA

    更新日期:2002-04-01 00:00:00

  • Masked hypertension, a review of the literature.

    abstract::Masked hypertension (blood pressure that is normal in the physicians' office but elevated elsewhere) is a common phenomenon as prevalence among studies varies from 8 to 45% and is seen at all ages. large discrepancies, however, exist between studies that have dealt with masked hypertension. It is of high clinical impo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/mbp.0b013e3280fb2792

    authors: Verberk WJ,Thien T,de Leeuw PW

    更新日期:2007-08-01 00:00:00

  • Determination of accuracies of 10 models of home blood pressure monitors using an oscillometric simulator.

    abstract:BACKGROUND:Patients and doctors often use home blood pressure monitoring (HBPM) to assess the control of hypertension. Despite its popularity there has always been some uncertainty with regard to its accuracy, reliability, reproducibility, and comparability. Although there are pre-market HBPM standards of accuracy, the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-199904010-00007

    authors: Yarows SA,Amerena JV

    更新日期:1999-02-01 00:00:00

  • Comparison of two automated sphygmomanometers for use in the office setting.

    abstract:OBJECTIVE:To compare readings obtained using two automated blood pressure (BP) recording devices, BpTRU and Omron 907, in a clinical setting. METHODS:Two series of 50 patients attending a hypertension unit for 24-h ambulatory BP monitoring had BP recorded either every 1 or every 2 min using BpTRU and Omron 907 devices...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32831e314f

    authors: Myers MG,Valdivieso M,Kiss A,Tobe SW

    更新日期:2009-02-01 00:00:00

  • Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). PATIENTS AND METHODS:In 33 patients aged 32-79 years, BP measurements were performed alternately u...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000216

    authors: Beime B,Deutsch C,Krüger R,Zimmermann E,Bramlage P

    更新日期:2016-12-01 00:00:00

  • Morning hypertension in chronic kidney disease is sustained type, but not surge type.

    abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32835026c6

    authors: Mizuno M,Fukuda M,Miura T,Wakamatsu T,Naito T,Sato R,Togawa H,Sasakawa Y,Tomonari T,Ono M,Kato Y,Ichikawa T,Shirasawa Y,Ito A,Yoshida A,Kimura G

    更新日期:2012-02-01 00:00:00

  • The application of generalizability theory to blood pressure resting levels and mental stress responses.

    abstract::BACKGROUND: Blood pressure measurements taken in the clinic or laboratory are assumed to generalize to the world outside. This is true both of casual blood pressure measurements and of changes in blood pressure responses to stress. Such generalizability is crucial to the usefulness of blood pressure measurements as pr...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Gerin W,Christenfeld N,Pieper C

    更新日期:1996-12-01 00:00:00

  • Cardiovascular triggers and morning events.

    abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Chasen C,Muller JE

    更新日期:1998-02-01 00:00:00

  • Conventional and ambulatory measurements of blood pressure in old patients with isolated systolic hypertension: baseline observations in the Syst-Eur trial.

    abstract::OBJECTIVES: To compare clinic and am measurements of blood pressure in old patients with isolated systolic hypertension and their reproducibilities. PATIENTS: In total 610 patients aged >/= 60 years with isolated systolic hypertension detected by clinic measurement were monitored during the placebo run-in phase of the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Emelianov D,Thijs L,Staessen JA,Celis H,Clement D,Davidson C,Gasowski J,Gil-Extremera B,Fogari R,Jääskivi M,Lehtonen A,Nedogoda S,O'Brien E,Palatini P,Parati G,Salvetti A,Vanhanen H,Webster J,Fagard R

    更新日期:1998-06-01 00:00:00

  • Ambulatory blood pressure variability: a conceptual review.

    abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000230

    authors: Zawadzki MJ,Small AK,Gerin W

    更新日期:2017-04-01 00:00:00

  • Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    abstract:BACKGROUND:To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN:Raw pulse wave and cuff pressure data were stored electronic...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200106000-00008

    authors: Wright JM,Mattu GS,Perry TL Jr,Gelferc ME,Strange KD,Zorn A,Chen Y

    更新日期:2001-06-01 00:00:00

  • Effect of fasting on 24-h blood pressure values of individuals with no previous history of hypertension.

    abstract:OBJECTIVE:We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. PATIENTS AND METHODS:This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage chang...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/MBP.0000000000000244

    authors: Seker A,Demirci H,Ocakoglu G,Aydin U,Ucar H,Yildiz G,Yaman O

    更新日期:2017-10-01 00:00:00

  • 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?

    abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200110000-00005

    authors: Enström IE,Pennert KM

    更新日期:2001-10-01 00:00:00

  • The effect of crossing legs on blood pressure.

    abstract:OBJECTIVE:To determine whether crossing of the legs at the knee or at the ankles during blood pressure measurement in sitting position has an effect on blood pressure. METHODS:One hundred and eleven patients, 60 women, mean age 52+/-17 years (19-80): 49 chronically treated hypertensives, 28 treated diabetics and 34 no...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e3280b083a7

    authors: Adiyaman A,Tosun N,Elving LD,Deinum J,Lenders JW,Thien T

    更新日期:2007-06-01 00:00:00

  • Is blunted heart rate decrease at night associated with prevalent organ damage in essential hypertension?

    abstract:AIM:The association between a blunted decrease in day–night heart rate and subclinical organ damage has not been investigated earlier in human hypertension. Therefore, we assessed such an association in a cohort of 658 untreated essential hypertensive patients. METHODS:All patients underwent procedures including cardi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/mbp.0b013e32834331fe

    authors: Cuspidi C,Meani S,Negri F,Valerio C,Sala C,Mancia G

    更新日期:2011-02-01 00:00:00

  • Blood pressure in acute ischemic stroke and mortality: a study with noninvasive blood pressure monitoring.

    abstract:BACKGROUND:In acute ischemic stroke, a transient elevation of blood pressure is common; its significance and its relationship with the neurological outcome are still unclear. METHODS:In 71 consecutive patients with acute ischemic stroke, aged 25-94 years, admitted to our unit, we investigated the relationships between...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000209077.23084.93

    authors: Sartori M,Benetton V,Carraro AM,Calò LA,Macchini L,Giantin V,Tosato F,Pessina AC,Semplicini A

    更新日期:2006-08-01 00:00:00

  • Validation of TM-2655 oscillometric device for blood pressure measurement.

    abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000200484.49540.12

    authors: Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

    更新日期:2006-04-01 00:00:00

  • Reduction of morning blood pressure surge after treatment with nifedipine GITS at bedtime, but not upon awakening, in essential hypertension.

    abstract:OBJECTIVES:The extent of morning blood pressure (BP) surge upon wakening has been associated with increased incidence of stroke and cardiovascular mortality. This trial investigated the antihypertensive efficacy and effects on the morning BP surge of awakening versus bedtime administration of nifedipine in essential hy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e32832e0d80

    authors: Hermida RC,Ayala DE,Mojón A,Alonso I,Fernández JR

    更新日期:2009-08-01 00:00:00

  • Ambulatory blood pressure monitoring in pediatric end-stage renal disease: chronic dialysis and transplantation.

    abstract::Hypertension is highly prevalent in pediatric patients with end-stage renal disease (ESRD). Ambulatory blood pressure monitoring (ABPM) has been used to characterize the altered circadian blood pressure patterns in ESRD in order to improve our understanding of the blood pressure dysregulation that occurs in these chil...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:

    authors: Sorof JM

    更新日期:1999-06-01 00:00:00

  • Identification of subjects with white-coat hypertension and persistently normal ambulatory blood pressure.

    abstract::OBJECTIVE: To assess the spontaneous changes in clinic blood pressure, ambulatory blood pressure (ABP) and left ventricular structure in untreated subjects with white-coat hypertension (WCH). DESIGN: A prospective observational study. PATIENTS AND METHODS: In 83 untreated subjects with WCH, 24 h non-invasive ABP monit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Verdecchia P,Schillaci G,Borgioni C,Ciucci A,Gattobigio R,Sacchi N,Guerrieri M,Comparato E,Porcellati C

    更新日期:1996-06-01 00:00:00

  • Relationship of vitamin D and parathyroid hormone with the nocturnal blood pressure decline in hypertension.

    abstract:OBJECTIVES:Vitamin D deficiency and high parathyroid hormone (PTH) levels have been linked with hypertension. Nondipper hypertension is associated with increased morbidity and mortality. We aimed to investigate the relationship of vitamin D and PTH levels with nondipper hypertension and nocturnal decline in untreated h...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000286

    authors: Karadag MK,Secen O

    更新日期:2017-12-01 00:00:00

  • Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016.

    abstract:BACKGROUND:Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC). OBJECTIVE:To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems. PATIENTS...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000349

    authors: Ostchega Y,Hughes JP,Nwankwo T,Zhang G

    更新日期:2018-12-01 00:00:00

  • Ambulatory blood pressure variation in normotensive subjects in relation to the sitting or standing position.

    abstract:OBJECTIVE:To evaluate the physiological variations in arterial blood pressure in normotensive subjects during activity and in relation to the sitting or lying position. METHODS:The subjects were 30 healthy volunteers who were normotensive and receiving no treatment. Blood pressure was measured using the validated moni...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200006000-00005

    authors: Mallion JM,Mouret S,Baguet JP,Maître A,Quesada JL,De Gaudemaris R

    更新日期:2000-06-01 00:00:00

  • Sensitivity, specificity, and predictive values of a forearm blood pressure measurement method in severe obesity.

    abstract::For blood pressure assessment, it has been reported that forearm blood pressure measurement appears to be as valid as an upper-arm blood pressure measurement method in individuals with severe obesity when correlated to the intra-arterial method, considered as the gold standard. Sensitivity, specificity, and predictive...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000097

    authors: Leblanc MÈ,Cloutier L,Poirier P

    更新日期:2015-04-01 00:00:00

  • Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians.

    abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000130223.80658.3d

    authors: Staal EM,Nygård OK,Omvik P,Gerdts E

    更新日期:2004-06-01 00:00:00

  • Characteristics of conventional blood pressure in studies on the predictive power of ambulatory blood pressure.

    abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,meta分析

    doi:10.1097/00126097-200202000-00006

    authors: Fagard RH,Staessen JA

    更新日期:2002-02-01 00:00:00