Performance Evaluation and Comparison of the Fully Automated Urinalysis Analyzers UX-2000 and Cobas 6500.

Abstract:

OBJECTIVE:To evaluate and compare the performances of the automated urinalysis devices UX-2000 and Cobas 6500. METHOD:A total of 258 urine specimens were collected from the routine specimen workload. We analyzed all specimens on both automated instruments and recorded the turnaround time from each method. Physical, chemical, and sedimentary urine components were compared between the automated and the manual method for each analyzer. RESULTS:The correlation of urine physical/chemical properties between the 2 instruments was excellent. The Cobas 6500 instrument demonstrated a higher level of agreement for red blood cells (Cobas 6500:R= 0.94; UX-2000:R= 0.78) and white blood cells (Cobas 6500:R= 0.95; UX-2000:R= 0.85). The UX-2000 demonstrated higher sensitivity for small round cells, hyaline casts, pathological casts, and bacteria. The median turnaround time was 1.5 minutes and 8.5 minutes for the Cobas 6500 and UX-2000, respectively. CONCLUSIONS:The 2 devices showed similar performance in technical evaluation; they each reduce workload and increase time saving. However, manual examination by technicians is recommended for pathological specimens.

journal_name

Lab Med

journal_title

Laboratory medicine

authors

Wesarachkitti B,Khejonnit V,Pratumvinit B,Reesukumal K,Meepanya S,Pattanavin C,Wongkrajang P

doi

10.1093/labmed/lmw002

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

124-33

issue

2

eissn

0007-5027

issn

1943-7730

pii

lmw002

journal_volume

47

pub_type

杂志文章
  • Comparison Between a Manual Squamous Cell Carcinoma Antigen Assay and an Automated Assay in a Clinical Setting.

    abstract:Objective:To compare a manual squamous cell carcinoma antigen (SCCA) assay and an automated SCCA assay in a clinical setting. Methods:We included, in this study, a total of 158 specimens that had been tested using the manual SCCA assay. The CanAg SCC EIA assay and the Elecsys SCC were compared for their clinical setti...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmy003

    authors: Lee S,Kim J,Uh Y,Kim HS,Lee JH

    更新日期:2018-07-05 00:00:00

  • Demystifying Biclonal Gammopathy: A Pathologist's Perspective.

    abstract:BACKGROUND:The production of 2 monoclonal proteins characterizes biclonal gammopathic manifestations (BGMs). The available medical literature from India is chiefly restricted to case reports. OBJECTIVE:To study the incidence of BGMs in a tertiary care center in Chandigarh, India, during a 4-year period. We evaluated t...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz006

    authors: Sharma S,Gupta P,Aggarwal R,Malhotra P,Minz RW,Bansal F

    更新日期:2019-10-10 00:00:00

  • Potential Use of Antigen-Based Rapid Test for SARS-CoV-2 in Respiratory Specimens in Low-Resource Settings in Egypt for Symptomatic Patients and High-Risk Contacts.

    abstract:OBJECTIVE:Because of the rapidly emerging SARS-CoV-2 pandemic and its wide public health challenges, rapid diagnosis is essential to decrease the spread. Antigen-based rapid detection tests are available; however, insufficient data about their performance are available. METHODS:The lateral-flow immunochromatographic B...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmaa104

    authors: Abdelrazik AM,Elshafie SM,Abdelaziz HM

    更新日期:2020-12-07 00:00:00

  • Accidental diagnosis: Aeromonas infection leading to discovery of acute myeloid leukemia with meylodysplastic syndrome.

    abstract:PATIENT:47-year-old African American man. CHIEF COMPLAINT:Initially, serious finger abscess. The patient reported severe pain that was localized to that finger only. HISTORY OF PRESENT ILLNESS:His finger had become sore and then progressively more painful and swollen. PAST MEDICAL HISTORY:A few weeks earlier, the pa...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1309/LMX711TANCVDHZJJ

    authors: Rausch S

    更新日期:2014-07-01 00:00:00

  • Cording in Disseminated Mycobacterium chelonae Infection in an Immunocompromised Patient.

    abstract::Cording is a phenomenon in which acid fast bacilli grow in parallel and was previously used as a means of presumptive microscopic identification of Mycobacterium tuberculosis (TB). However, this process has been shown in multiple other nontuberculous mycobacterial (NTM) species. Here we present the case of an immunoco...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmaa082

    authors: Olson G,McNulty MC,Mullane K,Beavis KG,Tesic V

    更新日期:2020-09-21 00:00:00

  • Establishing the Cause of Anemia in a Premature Newborn Infant.

    abstract::The three major causes of anemia in neonates are blood loss, decreased red blood cell production, and increased degradation of erythrocytes. Establishing the cause of anemia in a neonate born prematurely can be challenging. Clinically, fetomaternal hemorrhage (FMH) can be difficult to diagnose-the condition often pres...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmy026

    authors: den Besten G,van der Weide K,Schuerman FABA,Michael Cotten C,Rondeel JMM

    更新日期:2018-07-05 00:00:00

  • Sterility Testing of Stem Cell Products by Broad-Range Bacterial 16S Ribosomal DNA Polymerase Chain Reaction.

    abstract:OBJECTIVE:To evaluate broad-range 16S ribosomal DNA (rDNA) polymerase chain reaction (PCR) as a rapid screening tool to detect bacterial contamination of stem-cell products. METHODS:We performed the evaluation using whole blood spiked with serially diluted bacterial-type strains. Detection sensitivity was defined as t...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1309/LMKT4P9FFI2BBSIU

    authors: Tokuno O,Hayakawa A,Yanai T,Mori T,Ohnuma K,Tani A,Minami H,Sugimoto T

    更新日期:2015-01-01 00:00:00

  • Persistent Rivaroxaban Effect Due to Impaired Renal Clearance and Medication Effects.

    abstract::Rivaroxaban (Xarelto; Johnson & Johnson Services, Inc) is a direct oral anticoagulant (DOAC) that works by directly inhibiting the active site of factor Xa (FXa). Rivaroxaban is metabolized and cleared via the kidney and liver. The results of various studies have shown that patients with severe renal impairment should...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz044

    authors: Milito C,McRae H,Victor A,Refaai MA,Schmidt AE

    更新日期:2020-03-10 00:00:00

  • Hypoxia-Induced TGFBI as a Serum Biomarker for Laboratory Diagnosis and Prognosis in Patients with Pancreatic Ductal Adenocarcinoma.

    abstract:OBJECTIVE:To explore novel biomarkers for patients with pancreatic ductal adenocarcinoma (PDAC), from the perspective of tumor hypoxia. METHODS:We screened 29 differentially expressed and hypoxia-upregulated genes from the Oncomine database. A total of 12 secretory proteins that interact with hypoxia-inducible factor ...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz063

    authors: Yang L,Cui R,Li Y,Liang K,Ni M,Gu Y

    更新日期:2020-07-08 00:00:00

  • Iron Overload in an HFE Heterozygous Carrier: A Case Report and Literature Review.

    abstract::Hereditary hemochromatosis (HH) is an autosomal recessive disorder of iron metabolism characterized by increased iron absorption and tissue deposition. Three loss-of-function mutations in the hemochromatosis gene (HFE), namely, C282Y (c.845G>A), H63D (c.187C>G), and S65C (c.193A>T), account for the vast majority of HH...

    journal_title:Laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1093/labmed/lmy065

    authors: Turbiville D,Du X,Yo J,Jana BR,Dong J

    更新日期:2019-04-08 00:00:00

  • Assessment of the Reliability of the Sysmex XE-5000 Analyzer to Detect Platelet Clumps.

    abstract:OBJECTIVE:Platelet counts generated by automated analyzers on blood specimens that contain platelet clumps are often inaccurate and require verification by blood-smear review. In this study, we assessed the reliability of the Sysmex XE-5000 instrument to detect platelet clumps. METHOD:We reviewed automated complete bl...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmw016

    authors: Hawkins J,Gulati G,Uppal G,Gong J

    更新日期:2016-08-01 00:00:00

  • Mesenchymal Stem Cells in COVID-19: A Journey from Bench to Bedside.

    abstract::The COVID-19 pandemic has led to a major setback in both the health and economic sectors across the globe. The scale of the problem is enormous because we still do not have any specific anti-SARS-CoV-2 antiviral agent or vaccine. The human immune system has never been exposed to this novel virus, so the viral interact...

    journal_title:Laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1093/labmed/lmaa049

    authors: Sahu KK,Siddiqui AD,Cerny J

    更新日期:2021-01-04 00:00:00

  • Effects of Cell-Derived Microparticles on Immune Cells and Potential Implications in Clinical Medicine.

    abstract::In the past few years, interest has increased in cell-derived microparticles (MPs), which are defined by their size of from 0.1 to 1 μm, and can be derived from various cell types, including endothelial cells, leukocytes, red blood cells (RBCs), and platelets. These MPs carry negatively charged phosphatidylserine (PS)...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmaa043

    authors: Noulsri E

    更新日期:2020-08-20 00:00:00

  • Low S-adenosylmethionine/ S-adenosylhomocysteine Ratio in Urine is Associated with Chronic Kidney Disease.

    abstract:OBJECTIVE:To evaluate the association of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) in urine with chronic kidney disease (CKD). METHODS:Case-control study including 50 patients with CKD and 20 healthy volunteers. RESULTS:SAM level and SAM/SAH ratio in urine were significantly lower in patients than i...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz035

    authors: Kruglova MP,Grachev SV,Bulgakova PO,Ivanov AV,Virus ED,Nikiforova KA,Fedoseev AN,Savina GD,Kubatiev AA

    更新日期:2020-01-02 00:00:00

  • Reproducibility of TEG Parameters in Stable Cirrhotics.

    abstract:Background:Thromboelastography (TEG) has become the standard of care in liver-transplant surgery to identify real-time abnormalities in the coagulation cascade. To our knowledge, no studies have been performed to measure the intrasubject reproducibility of TEG parameters in cirrhotic patients. Objective:To perform a v...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmx041

    authors: George G,Manatasahit W,Balasubramanian M,Navarro V

    更新日期:2018-07-05 00:00:00

  • Standardizing Phlebotomy Job Descriptions.

    abstract:BACKGROUND:The University of Maryland Medical System, like all other medical systems, is faced with providing the highest quality care in an environment of increased demands and competition for resources. Some responses to this pressure include improved integration, coordination, and efficiency. Laboratory integration ...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmw051

    authors: Cook J

    更新日期:2017-02-01 00:00:00

  • Schistosoma haematobium Infection That Mimics Bladder Cancer in a 66-Year-Old Ethnic Egyptian Man.

    abstract:PATIENT:66-year-old ethnic Egyptian man. CHIEF COMPLAINT:Hematuria. HISTORY OF PRESENT ILLNESS:The patient had a history of multiple episodes of gross hematuria for the past 5 years. Because the hematuria usually resolved on its own, he did not seek medical attention during that time. Bladder cancer was suspected. P...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1309/LM96EJPPBYADIOVC

    authors: Zepeda CM,Coffey KH

    更新日期:2015-10-01 00:00:00

  • A 13-question approach to resolving serological discrepancies in the transfusion medicine laboratory.

    abstract::Laboratory professionals, consultants, and treating physicians may encounter discrepancies in serological testing results for numerous reasons; identifying the reason(s) for the presence of an unexpected antibody or antigen can be challenging. A question-based approach can be useful in identifying the underlying cause...

    journal_title:Laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1309/LMEWVSNT2F3O5JDN

    authors: Yudin J,Heddle NM

    更新日期:2014-07-01 00:00:00

  • Correlation between Osteoprotegerin Levels and Antiphospholipid Syndrome Parameters.

    abstract:OBJECTIVE:To identify the osteoprotegerin (OPG) correlates with antiphospholipid syndrome (APS) parameters. METHODS:Our cohort included 40 patients with primary APS disease associated with systemic lupus erythematosus (SLE) (mean age, 43.7 years; 87% female). Data on cardiovascular risk factors and specific clinical e...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz051

    authors: Caraiola S,Dima A,Jurcut C,Jurcut R,Baicus C,Baicus A

    更新日期:2020-03-10 00:00:00

  • Detection Rate of Colorectal Cancer or Precancer Adenoma by Colonoscopy After 1, 2, or 3 Positive Results via Fecal Immunochemical Testing.

    abstract:BACKGROUND:Single-vial fecal immunochemical testing (FIT) is an accepted method of colorectal cancer (CRC) screening. The available 3-vial FIT data set allows for comparison of colonoscopy results using various screening methods. OBJECTIVE:To determine the optimal number of vials for a strong FIT-screening program by ...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmy075

    authors: Hancock JA,Palmer GA

    更新日期:2019-07-16 00:00:00

  • Comparison of 2 Anti-PLA2R Immunoassays for the Diagnosis of Primary Membranous Nephropathy.

    abstract:Background:Anti-phospholipase A2 receptor (anti-PLA2R) is a promising biomarker for diagnosis, activity evaluation, therapy monitoring, and prognostic estimation of primary membranous neuropathy (pMN). Difference in methodology may be one cause of the discrepancy in anti-PLA2R-positive percentages in reported studies. ...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmy016

    authors: Li W,Guo Y,Zhang Z,Zhang F,Liu X,Ji X,Liu L,Wang H

    更新日期:2018-10-11 00:00:00

  • A Survey of Knowledge and Practices of Transfusion Medicine Among Post Intern Doctors in Specialized Hospital in Sri Lanka.

    abstract:BACKGROUND:Knowledge of transfusion medicine is the key element of better transfusion practices. This deficit observed at the blood bank end on daily basis exposing the patients for redundant risk. We assessed the knowledge of transfusion medicine among post intern doctors. OBJECTIVE:To assess the knowledge of transfu...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmw056

    authors: Kumarage S,Fernando R,Gunasekara L

    更新日期:2017-02-01 00:00:00

  • Quantitation of Cell-Derived Microparticles in Blood Products and Its Potential Applications in Transfusion Laboratories.

    abstract::Cell-derived microparticles (MPs) are small fragments released from various cells when they are activated or undergo apoptosis. In the field of transfusion medicine, a number of studies have documented increased levels of MPs in blood products, which have been associated with multiple factors, including donor variabil...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz100

    authors: Noulsri E

    更新日期:2020-09-01 00:00:00

  • Mutation Analysis Using Multiplex Ligation-Dependent Probe Amplification in Consanguineous Families in South India with a Child with Profound Hearing Impairment.

    abstract:BACKGROUND:Consanguineous marriage, a common practice in South India, increase the incidence of autosomal recessive diseases such as nonsyndromic hearing loss (NSHL) in offspring. This trend was noted in the children with hearing impairment (HI) who received cochlear implants (CI) at our University hospital in Porur, C...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz027

    authors: Arunachalam RK,Koshy T,Venkatesan V,Dawson GP,Franklin Durairaj Paul S,George P

    更新日期:2020-01-02 00:00:00

  • Correlation of Increased Expression of MicroRNA-155 in Bladder Cancer and Prognosis.

    abstract:OBJECTIVE:To investigate the expression level and clinical significance of microRNA-155 (miR-155) in bladder cancer. METHODS:We collected 102 pairs of tissue specimens from patients with primary bladder cancer and adjacent normal bladder specimens between March 2008 and May 2013. Quantitative real-time polymerase chai...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1309/LMWR9CEA2K2XVSOX

    authors: Wang H,Men CP

    更新日期:2015-04-01 00:00:00

  • The Use and Misuse of Statistical Methods in Cytopathology Studies: Review of 6 Journals.

    abstract:Background:The misuse of statistical methods in diagnostic accuracy studies has been criticized in many publications. Objective:To assess the use and misuse of statistical methods in medical journal articles. Methods:We reviewed 141 original articles from 6 cytopathology journals published in 2014. Results:In total,...

    journal_title:Laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1093/labmed/lmy036

    authors: Bahar B,Pambuccian SE,Barkan GA,Akdas Y

    更新日期:2019-01-01 00:00:00

  • Tacrolimus: A Review of Laboratory Detection Methods and Indications for Use.

    abstract::Tacrolimus (Tac) is an immunosuppressive drug that is used in preventing organ and tissue rejection in patients after transplantation. Tac administration requires frequent and diligent monitoring by physicians to ensure proper dosage and to limit the potential for harmful adverse effects, which can include renal damag...

    journal_title:Laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1093/labmed/lmx056

    authors: Kalt DA

    更新日期:2017-11-08 00:00:00

  • Ficin-Treated Red Cells Help Identify Clinically Significant Alloantibodies Masked as Reactions of Undetermined Specificity in Gel Microtubes.

    abstract::Non-specific antibodies or antibodies of undetermined significance (AUS) often pose problems for a blood bank technologist and physician. It is well known that antibodies can weaken and evanesce over time, thus eluding detection by routine blood bank techniques. Special enhancement techniques exist (eg, ficin treatmen...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmw062

    authors: Hill BC,Hanna CA,Adamski J,Pham HP,Marques MB,Williams LA 3rd

    更新日期:2017-02-01 00:00:00

  • ABCA1 and ABCG1 expression in the small intestine of type 2 diabetic rats.

    abstract:OBJECTIVE:Inflammation of the small intestine may occur in type 2 diabetes. This study aimed to investigate whether ATP-binding cassette transporter A1 (ABCA1) and G1 (ABCG1) were altered in chronic inflammation of the small intestine of type 2 diabetic rats. METHODS:Thirty-two male Sprague-Dawley rats were used. Eigh...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1309/lmo485spyxbqanxj

    authors: Lou J,Zhou H,Li C,Hu L,Lu X,Li J,Yao H,Li W,Zhang X,Xu M

    更新日期:2014-01-01 00:00:00

  • A Case of Chronic Thrombocytopenia in a 17-Year-Old Female.

    abstract::Storage pool deficiency (SPD) is a group of rare platelet disorders that result from deficiencies in α-granules, δ-granules, or both. One type of α-SPD is gray platelet syndrome (GPS), caused by mutations in the neurobeachin-like 2 (NBEAL2) gene that results in a bleeding diathesis, thrombocytopenia, splenomegaly, and...

    journal_title:Laboratory medicine

    pub_type: 杂志文章

    doi:10.1093/labmed/lmz013

    authors: Riley R,Khan A,Pai S,Warmke L,Winkler M,Gunning W

    更新日期:2019-10-10 00:00:00