Abstract:
OBJECTIVE:Because of the rapidly emerging SARS-CoV-2 pandemic and its wide public health challenges, rapid diagnosis is essential to decrease the spread. Antigen-based rapid detection tests are available; however, insufficient data about their performance are available. METHODS:The lateral-flow immunochromatographic BIOCREDIT COVID-19 antigen test was evaluated using nasopharyngeal swabs in a viral transport medium from patients with confirmed infection, contacts, and exposed healthcare professionals at Fayoum University Hospital in Egypt. Test performance was determined in comparison to the SARS-CoV-2 real-time reverse-transcription polymerase chain reaction (RT-PCR) test. RESULTS:Three hundred ten specimens from 3 categories-patients with confirmed diagnoses of COVID-19, contacts, and exposed healthcare professionals-were included; 188 specimens were RT-PCR-positive, from which 81 were detected by rapid antigen test. Overall sensitivity was 43.1%. Sensitivity was significantly higher in specimens with high viral loads. CONCLUSION:Poor sensitivity of the BIOCREDIT COVID-19 test does not permit its use for diagnosis, and it can only be used in conjunction with RT-PCR for screening.
journal_name
Lab Medjournal_title
Laboratory medicineauthors
Abdelrazik AM,Elshafie SM,Abdelaziz HMdoi
10.1093/labmed/lmaa104subject
Has Abstractpub_date
2020-12-07 00:00:00eissn
0007-5027issn
1943-7730pii
6025080pub_type
杂志文章abstract::Extremely low hemoglobin A1c (HbA1c) results below reference range are rare, and the causes and clinical implications associated with low HbA1c results are not well understood among clinical laboratorians. A case of extremely low HbA1c results was reported, in which liver cirrhosis, subacute hemorrhage and recent tran...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmw050
更新日期:2017-02-01 00:00:00
abstract::Antinuclear antibodies (ANAs) are autoantibodies that attack self-proteins within cell nucleus structures; their presence in serum may indicate an autoimmune disease. Also, positive ANA test results have been obtained in chronic infectious diseases, cancers, medication-related adverse events, and even healthy individu...
journal_title:Laboratory medicine
pub_type: 杂志文章,评审
doi:10.1093/labmed/lmy024
更新日期:2018-07-05 00:00:00
abstract::In the past few years, interest has increased in cell-derived microparticles (MPs), which are defined by their size of from 0.1 to 1 μm, and can be derived from various cell types, including endothelial cells, leukocytes, red blood cells (RBCs), and platelets. These MPs carry negatively charged phosphatidylserine (PS)...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmaa043
更新日期:2020-08-20 00:00:00
abstract::Cell-derived microparticles (MPs) are small fragments released from various cells when they are activated or undergo apoptosis. In the field of transfusion medicine, a number of studies have documented increased levels of MPs in blood products, which have been associated with multiple factors, including donor variabil...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz100
更新日期:2020-09-01 00:00:00
abstract:BACKGROUND:The production of 2 monoclonal proteins characterizes biclonal gammopathic manifestations (BGMs). The available medical literature from India is chiefly restricted to case reports. OBJECTIVE:To study the incidence of BGMs in a tertiary care center in Chandigarh, India, during a 4-year period. We evaluated t...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz006
更新日期:2019-10-10 00:00:00
abstract::Cording is a phenomenon in which acid fast bacilli grow in parallel and was previously used as a means of presumptive microscopic identification of Mycobacterium tuberculosis (TB). However, this process has been shown in multiple other nontuberculous mycobacterial (NTM) species. Here we present the case of an immunoco...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmaa082
更新日期:2020-09-21 00:00:00
abstract:Background:Thromboelastography (TEG) has become the standard of care in liver-transplant surgery to identify real-time abnormalities in the coagulation cascade. To our knowledge, no studies have been performed to measure the intrasubject reproducibility of TEG parameters in cirrhotic patients. Objective:To perform a v...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmx041
更新日期:2018-07-05 00:00:00
abstract:OBJECTIVE:To evaluate the association of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) in urine with chronic kidney disease (CKD). METHODS:Case-control study including 50 patients with CKD and 20 healthy volunteers. RESULTS:SAM level and SAM/SAH ratio in urine were significantly lower in patients than i...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz035
更新日期:2020-01-02 00:00:00
abstract:BACKGROUND:Single-vial fecal immunochemical testing (FIT) is an accepted method of colorectal cancer (CRC) screening. The available 3-vial FIT data set allows for comparison of colonoscopy results using various screening methods. OBJECTIVE:To determine the optimal number of vials for a strong FIT-screening program by ...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmy075
更新日期:2019-07-16 00:00:00
abstract::As new killer-cell immunoglobulin-like receptor (KIR) alleles are discovered, a challenge in KIR typing is maintaining sensitivity and specificity. A single nucleotide polymorphism assay can be used to type functional KIR2DL1 alleles. We improved recently on the earlier method by using a higher-specificity assay. The ...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/LMMN1K6SBRJCGD9J
更新日期:2015-07-01 00:00:00
abstract:OBJECTIVE:To analyze the performance characteristics, stability, and clinical value of lipoprotein-associated phospholipase A2 (Lp-PLA2) using an enzymatic kinetic method. METHODS:The performance characteristics included reference intervals, precision, and accuracy. We assessed Lp-PLA2 stability by comparing Lp-PLA2 c...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmy086
更新日期:2019-07-16 00:00:00
abstract::Storage pool deficiency (SPD) is a group of rare platelet disorders that result from deficiencies in α-granules, δ-granules, or both. One type of α-SPD is gray platelet syndrome (GPS), caused by mutations in the neurobeachin-like 2 (NBEAL2) gene that results in a bleeding diathesis, thrombocytopenia, splenomegaly, and...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz013
更新日期:2019-10-10 00:00:00
abstract:PATIENT:66-year-old ethnic Egyptian man. CHIEF COMPLAINT:Hematuria. HISTORY OF PRESENT ILLNESS:The patient had a history of multiple episodes of gross hematuria for the past 5 years. Because the hematuria usually resolved on its own, he did not seek medical attention during that time. Bladder cancer was suspected. P...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/LM96EJPPBYADIOVC
更新日期:2015-10-01 00:00:00
abstract:OBJECTIVE:Inflammation of the small intestine may occur in type 2 diabetes. This study aimed to investigate whether ATP-binding cassette transporter A1 (ABCA1) and G1 (ABCG1) were altered in chronic inflammation of the small intestine of type 2 diabetic rats. METHODS:Thirty-two male Sprague-Dawley rats were used. Eigh...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/lmo485spyxbqanxj
更新日期:2014-01-01 00:00:00
abstract:BACKGROUND:Multirules are often employed to monitor quality control (QC). The performance of multirules is usually determined by simulation and is difficult to predict. Previous studies have not provided computer code that would enable one to experiment with multirules. It would be helpful for analysts to have computer...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz038
更新日期:2020-01-02 00:00:00
abstract::Health systems face intense pressure to decrease costs and improve services as the health care delivery system in the United States undergoes tremendous change due to health care reform. As health systems grow, like any business, they are forced to explore standardization to realize and maintain efficient practices. C...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmw069
更新日期:2017-08-01 00:00:00
abstract:OBJECTIVE:To investigate the expression level and clinical significance of microRNA-155 (miR-155) in bladder cancer. METHODS:We collected 102 pairs of tissue specimens from patients with primary bladder cancer and adjacent normal bladder specimens between March 2008 and May 2013. Quantitative real-time polymerase chai...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/LMWR9CEA2K2XVSOX
更新日期:2015-04-01 00:00:00
abstract:Background:When unpredicted surgical blood loss occurs, it is essential that blood arrive from the blood bank in a timely manner. Objective:To evaluate the turnaround time (TAT) for red blood cells (RBCs) from the blood bank to the operating suite. Cases with delayed TATs were further analyzed to determine potential c...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmx016
更新日期:2017-08-01 00:00:00
abstract:PATIENT:78-year-old African-American man. PAST MEDICAL HISTORY:Chronic lymphocytic leukemia first diagnosed in 2003, with a subsequent relapse in 2006 and another in 2010. HISTORY OF PRESENT ILLNESS:In late 2011, the patient was admitted to the hospital for cholelithiasis, at which time his treating physician inciden...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/LMLWQDB2Q6LS7VQG
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVE:To determine whether K2-ethylenediaminetetraacetic acid (EDTA) and K3-EDTA Greiner tubes could be used interchangeably for glycosylated hemoglobin, type A1C (HbA1c) measurement via the Abbott Laboratories ARCHITECT chemiluminescent microparticle HbA1c assay on the ARCHITECT i2000SR immunoanalyzer at our unive...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmv016
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVE:Examination of urine sediment is crucial in acute kidney injury (AKI). In such renal injury, tubular epithelial cells, epithelial cell casts, and dysmorphic red cells may provide clues to etiology. The aim of this study was to compare automated urinalysis findings with manual microscopic analysis in AKI. MET...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmaa069
更新日期:2020-10-03 00:00:00
abstract:BACKGROUND:Oxidative stress has been associated with the progression of atherosclerosis and activation of genes that lead to increased deposition of proteins in the extracellular matrix. Bone sialoprotein (BSP) and osteonectin are proteins involved in the initiation and progression of vascular calcification. OBJECTIVE...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/LMUJWVQFW6CJMSOQ
更新日期:2014-10-01 00:00:00
abstract:Background:The misuse of statistical methods in diagnostic accuracy studies has been criticized in many publications. Objective:To assess the use and misuse of statistical methods in medical journal articles. Methods:We reviewed 141 original articles from 6 cytopathology journals published in 2014. Results:In total,...
journal_title:Laboratory medicine
pub_type: 杂志文章,评审
doi:10.1093/labmed/lmy036
更新日期:2019-01-01 00:00:00
abstract:BACKGROUND:Consanguineous marriage, a common practice in South India, increase the incidence of autosomal recessive diseases such as nonsyndromic hearing loss (NSHL) in offspring. This trend was noted in the children with hearing impairment (HI) who received cochlear implants (CI) at our University hospital in Porur, C...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz027
更新日期:2020-01-02 00:00:00
abstract:OBJECTIVES:To determine the effect of a modified request form on the total use of γ-glutamyl transferase (GGT) usage and the ratio of inappropriate testing. METHODS:We modified a test request form by moving GGT from the "Liver profile" to the "Other" section. The criteria for appropriate GGT ordering were developed ba...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1309/LM7E5LG6PWJYEFUJ
更新日期:2015-07-01 00:00:00
abstract::The COVID-19 pandemic has led to a major setback in both the health and economic sectors across the globe. The scale of the problem is enormous because we still do not have any specific anti-SARS-CoV-2 antiviral agent or vaccine. The human immune system has never been exposed to this novel virus, so the viral interact...
journal_title:Laboratory medicine
pub_type: 杂志文章,评审
doi:10.1093/labmed/lmaa049
更新日期:2021-01-04 00:00:00
abstract::Non-specific antibodies or antibodies of undetermined significance (AUS) often pose problems for a blood bank technologist and physician. It is well known that antibodies can weaken and evanesce over time, thus eluding detection by routine blood bank techniques. Special enhancement techniques exist (eg, ficin treatmen...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmw062
更新日期:2017-02-01 00:00:00
abstract:OBJECTIVE:To test a hybrid polyethylene glycol (PEG)/gel method, specifically to attempt to increase reaction strength of accidentally overdiluted anti-Cob and broadly for proof of concept. METHODS:Methods were divided into 2 basic steps: sensitization and antiglobulin (AHG) testing. Sensitization was performed with P...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmz015
更新日期:2020-03-10 00:00:00
abstract:Background:Interest in vitamin D has increased during the past 2 decades, with a corresponding increase in laboratory testing of 25-hydroxyvitamin D [25(OH)D]. The vast majority of specimens tested display normal or deficient levels of 25(OH)D; concentrations rarely fall in the potentially toxic range. Methods:We perf...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmx077
更新日期:2018-03-21 00:00:00
abstract:OBJECTIVE:Platelet counts generated by automated analyzers on blood specimens that contain platelet clumps are often inaccurate and require verification by blood-smear review. In this study, we assessed the reliability of the Sysmex XE-5000 instrument to detect platelet clumps. METHOD:We reviewed automated complete bl...
journal_title:Laboratory medicine
pub_type: 杂志文章
doi:10.1093/labmed/lmw016