Potential applications of the quantitative susceptibility mapping (QSM) in MR-guided radiation therapy.

Abstract:

:Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR-invisible' metal-based devices. In this study, the feasibility of quantitative susceptibility mapping (QSM) for visualization of some MR-invisible radiation therapy devices was studied. Our recently proposed QSM-based algorithm for brachytherapy seed visualization was modified and the feasibility of the optimized algorithm for visualization of different devices including: brachytherapy seeds, plastic interstitial needles, CT-markers and obturators, and different types of fiducial markers in agar, prostate and meat phantoms were studied. All phantoms were scanned using 3T MR scanner with a 3D multi-echo gradient recalled echo (ME-GRE) pulse sequence. The QSM results in all phantoms were compared to CT images for spatial accuracy of the QSM. The applied post-processing algorithm was found to be insensitive to the seeds' type; also, presence of nearby calcifications had no effect on seed visualization. QSM successfully generated positive contrast for both types of investigated fiducial markers with high spatial accuracy compared to CT. Interstitial needles containing both aluminum-based CT-maker and titanium-based obturators were accurately depicted on the QSM. The proposed QSM-based technique relies on the standard MR pulse sequences and visualize the conventional MR-invisible metallic devices with CT-like positive contrast solely through post-processing. Upon in vivo validation of the technique, QSM may have the potential to replace CT for an MR-only guided radiation therapy.

journal_name

Phys Med Biol

authors

Nosrati R,Paudel M,Ravi A,Pejovic-Milic A,Morton G,Stanisz GJ

doi

10.1088/1361-6560/ab2623

subject

Has Abstract

pub_date

2019-07-16 00:00:00

pages

145013

issue

14

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy.

    abstract::To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa845

    authors: Yepes P,Adair A,Grosshans D,Mirkovic D,Poenisch F,Titt U,Wang Q,Mohan R

    更新日期:2018-02-09 00:00:00

  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • Exact analytic reconstruction in x-ray fluorescence CT and approximated versions.

    abstract::X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Rivière (2004 Phys. Med. Biol. 49 2391-405) presented an appr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/007

    authors: Miqueles EX,De Pierro AR

    更新日期:2010-02-21 00:00:00

  • CyberArc: a non-coplanar-arc optimization algorithm for CyberKnife.

    abstract::The goal of this study is to demonstrate the feasibility of a novel non-coplanar-arc optimization algorithm (CyberArc). This method aims to reduce the delivery time of conventional CyberKnife treatments by allowing for continuous beam delivery. CyberArc uses a 4 step optimization strategy, in which nodes, beams, and c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6f92

    authors: Kearney V,Cheung JP,McGuinness C,Solberg TD

    更新日期:2017-06-26 00:00:00

  • Monte Carlo aided room scatter studies in the primary air kerma strength standardization of a remote afterloading 192Ir HDR source.

    abstract::Corrections for room scatter, [ksc(d, H)]RM, were derived using Monte Carlo methods for rooms of various sizes, including the brachytherapy treatment room, in which primary air kerma strength standardization of a remote afterloading microSelectron 192Ir HDR source was carried out, using a 60 cm3 spherical graphite ion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/9/303

    authors: Selvam TP,Rajan KN,Nagarajan PS,Sethulakshmi P,Bhatt BC

    更新日期:2001-09-01 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • Dose evaluation of boron neutron capture synovectomy using the THOR epithermal neutron beam: a feasibility study.

    abstract::Rheumatoid arthritis is one of the most common epidemic diseases in the world. For some patients, the treatment with steroids or nonsteroidal anti-inflammatory drugs is not effective, thus necessitating physical removal of the inflamed synovium. Alternative approaches other than surgery will provide appropriate diseas...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/6/014

    authors: Wu J,Chang SJ,Chuang KS,Hsueh YW,Yeh KC,Wang JN,Tsai WP

    更新日期:2007-03-21 00:00:00

  • Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system.

    abstract::The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measureme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/N1

    authors: Yamamoto S,Watabe T,Watabe H,Aoki M,Sugiyama E,Imaizumi M,Kanai Y,Shimosegawa E,Hatazawa J

    更新日期:2012-01-21 00:00:00

  • An analysis of the accuracy of magnetic resonance flip angle measurement methods.

    abstract::Several methods of flip angle mapping for magnetic resonance imaging have been proposed. We evaluated the accuracy of five methods of flip angle measurement in the presence of measurement noise. Our analysis was performed in a closed form by propagation of probability density functions (PDFs). The flip angle mapping m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/20/008

    authors: Morrell GR,Schabel MC

    更新日期:2010-10-21 00:00:00

  • An analytical reconstruction model of the spread-out Bragg peak using laser-accelerated proton beams.

    abstract::With the development of laser technology, laser-driven proton acceleration provides a new method for proton tumor therapy. However, it has not been applied in practice because of the wide and decreasing energy spectrum of laser-accelerated proton beams. In this paper, we propose an analytical model to reconstruct the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6fce

    authors: Tao L,Zhu K,Zhu J,Xu X,Lin C,Ma W,Lu H,Zhao Y,Lu Y,Chen JE,Yan X

    更新日期:2017-07-07 00:00:00

  • Dosimetry of 106Ru eye applicators with a p-type silicon detector.

    abstract::Beta emitting 106Ru-applicators are used to treat choroidal melanoma. In order to improve the accuracy and simplify the dosimetry of these applicators, the suitability of using a p-type silicon semiconductor detector has been investigated. The detector is calibrated in a low energy electron beam. An important property...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/7/005

    authors: Lax I

    更新日期:1991-07-01 00:00:00

  • A model for the accurate computation of the lateral scattering of protons in water.

    abstract::A pencil beam model for the calculation of the lateral scattering in water of protons for any therapeutic energy and depth is presented. It is based on the full Molière theory, taking into account the energy loss and the effects of mixtures and compounds. Concerning the electromagnetic part, the model has no free para...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/N102

    authors: Bellinzona EV,Ciocca M,Embriaco A,Ferrari A,Fontana A,Mairani A,Parodi K,Rotondi A,Sala P,Tessonnier T

    更新日期:2016-02-21 00:00:00

  • PBS machine interlocks using EWMA.

    abstract::Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could incr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/400

    authors: Clasie BM,Kooy HM,Flanz JB

    更新日期:2016-01-07 00:00:00

  • Transport calculations of depth-dose distributions for gadolinium neutron capture therapy.

    abstract::Depth-dose distributions were calculated for thermal and epithermal neutron fluence and capture gamma ray dose rates using a two-dimensional neutron-coupled gamma-ray transport code (DOT 3.5) for gadolinium neutron capture therapy. The results show that (i) a capture gamma-ray dose rate of 10 Gy h-1 was obtained with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/1/010

    authors: Matsumoto T

    更新日期:1992-01-01 00:00:00

  • 4D cone beam CT-based dose assessment for SBRT lung cancer treatment.

    abstract::The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/554

    authors: Cai W,Dhou S,Cifter F,Myronakis M,Hurwitz MH,Williams CL,Berbeco RI,Seco J,Lewis JH

    更新日期:2016-01-21 00:00:00

  • Analysis of quality control data of eight modern radiotherapy linear accelerators: the short- and long-term behaviours of the outputs and the reproducibility of quality control measurements.

    abstract::Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/14/020

    authors: Kapanen M,Tenhunen M,Hämäläinen T,Sipilä P,Parkkinen R,Järvinen H

    更新日期:2006-07-21 00:00:00

  • Is it necessary to plan with safety margins for actively scanned proton therapy?

    abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/011

    authors: Albertini F,Hug EB,Lomax AJ

    更新日期:2011-07-21 00:00:00

  • Improving mass detection using combined feature representations from projection views and reconstructed volume of DBT and boosting based classification with feature selection.

    abstract::In digital breast tomosynthesis (DBT), image characteristics of projection views and reconstructed volume are different and both have the advantage of detecting breast masses, e.g. reconstructed volume mitigates a tissue overlap, while projection views have less reconstruction blur artifacts. In this paper, an improve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/22/8809

    authors: Kim DH,Kim ST,Ro YM

    更新日期:2015-11-21 00:00:00

  • The relevance of very low energy ions for heavy-ion therapy.

    abstract::Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/N03

    authors: Elsässer T,Gemmel A,Scholz M,Schardt D,Krämer M

    更新日期:2009-04-07 00:00:00

  • Task-based measures of image quality and their relation to radiation dose and patient risk.

    abstract::The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/60/2/R1

    authors: Barrett HH,Myers KJ,Hoeschen C,Kupinski MA,Little MP

    更新日期:2015-01-21 00:00:00

  • An automatic algorithm to exploit the symmetries of the system response matrix in positron emission tomography iterative reconstruction.

    abstract::Positron emission tomography (PET) iterative 3D reconstruction is a very computational demanding task. One of the main issues of the iterative reconstruction concerns the management of the system response matrix (SRM). The SRM models the relationship between the projection and the voxel space and its memory footprint ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae12b

    authors: Camarlinghi N,Sportelli G,Guerra AD,Belcari N

    更新日期:2018-09-28 00:00:00

  • Optimisation of field flatness and depth-dose for therapy electron beams.

    abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/007

    authors: Marbach JR,Almond PR

    更新日期:1981-05-01 00:00:00

  • Monte Carlo modelling of electron beams from medical accelerators.

    abstract::Monte Carlo simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development of computer technology, Monte Carlo based treatment planning for radiation therapy is becoming practical. A basic requirement for Monte Carlo treatment pl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/12/201

    authors: Ma CM,Jiang SB

    更新日期:1999-12-01 00:00:00

  • Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization.

    abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2838

    authors: Gao H

    更新日期:2016-04-07 00:00:00

  • Radiofrequency heating effects around resonant lengths of wire in MRI.

    abstract::Several recent reports agree that the potentially dangerous heating around extended wires or coaxial cables inside the bodycoil of a magnetic resonance imager is related to resonant effects. No quantitative description of this idea has been given so far. We analyse a simplified situation, where a straight metallic wir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/16/312

    authors: Pictet J,Meuli R,Wicky S,van der Klink JJ

    更新日期:2002-08-21 00:00:00

  • Kill painting of hypoxic tumors with multiple ion beams.

    abstract::We report on a novel method for simultaneous biological optimization of treatment plans for hypoxic tumors using multiple ion species. Our previously introduced kill painting approach, where the overall cell killing is optimized on biologically heterogeneous targets, was expanded with the capability of handling differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafe40

    authors: Sokol O,Krämer M,Hild S,Durante M,Scifoni E

    更新日期:2019-02-08 00:00:00

  • Treatment plan modification using voxel-based weighting factors/dose prescription.

    abstract::Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/315

    authors: Wu C,Olivera GH,Jeraj R,Keller H,Mackie TR

    更新日期:2003-08-07 00:00:00

  • Positioning of a plane-parallel ionization chamber in clinical electron beams and the impact on perturbation factors.

    abstract::Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/011

    authors: Zink K,Wulff J

    更新日期:2009-04-21 00:00:00

  • Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

    abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1325

    authors: Anizan N,Wang H,Zhou XC,Wahl RL,Frey EC

    更新日期:2015-02-07 00:00:00

  • Dual energy x-ray laser measurement of calcaneal bone mineral density.

    abstract::In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/305

    authors: Hakulinen MA,Saarakkala S,Töyräs J,Kröger H,Jurvelin JS

    更新日期:2003-06-21 00:00:00