The relevance of very low energy ions for heavy-ion therapy.

Abstract:

:Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very low energy (<500 keV amu(-1)) ions, either as primary particles or originating from molecular and nuclear fragmentations. We show, however, that slow heavy ions with energies below 500 keV amu(-1) only play a negligible role in cancer treatments for several reasons. Their residual range is very small compared to the relevant length scale of treatment planning. Moreover, their relative frequency and also their relative dose distribution are insignificant, since energy loss and range straggling in ion slowing down processes as well as the necessary superposition of Bragg peaks wash out small-scale special effects. Additionally, we show that even a 1000 times larger biological damage of such slow ions would not result in a clinically relevant increase of the photon-equivalent dose. Therefore, neither a more precise physical description of ions in the very distal part of the Bragg peak nor the consideration of radiation damage induced by hyperthermal ions would result in a meaningful improvement of current models for heavy-ion treatment planning.

journal_name

Phys Med Biol

authors

Elsässer T,Gemmel A,Scholz M,Schardt D,Krämer M

doi

10.1088/0031-9155/54/7/N03

subject

Has Abstract

pub_date

2009-04-07 00:00:00

pages

N101-6

issue

7

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(09)03414-9

journal_volume

54

pub_type

杂志文章
  • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    abstract::A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/014

    authors: Lee SC,Kim HK,Chun IK,Cho MH,Lee SY,Cho MH

    更新日期:2003-12-21 00:00:00

  • Estimation of torque on mechanical heart valves due to magnetic resonance imaging including an estimation of the significance of the Lenz effect using a computational model.

    abstract::Mitral and aortic valve replacement is a procedure which is common in cardiac surgery. Some of these replacement valves are mechanical and contain moving metal parts. Should the patient in whom such a valve has been implanted be involved in magnetic resonance imaging, there is a possible dangerous interaction between ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/12/320

    authors: Robertson NM,Diaz-Gomez M,Condon B

    更新日期:2000-12-01 00:00:00

  • Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model.

    abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4364

    authors: Šarolić A,Živković Z,Reilly JP

    更新日期:2016-06-21 00:00:00

  • Reference dosimetry on TomoTherapy: an addendum to the 1990 UK MV dosimetry code of practice.

    abstract::The current UK code of practice for high-energy photon therapy dosimetry (Lillicrap et al 1990 Phys. Med. Biol. 35 1355-60) gives instructions for measuring absorbed dose to water under reference conditions for megavoltage photons. The reference conditions and the index used to specify beam quality require that a mach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/6/1339

    authors: Thomas SJ,Aspradakis MM,Byrne JP,Chalmers G,Duane S,Rogers J,Thomas RA,Tudor GS,Twyman N,IPEM Working Party.

    更新日期:2014-03-21 00:00:00

  • Reconsideration of the backscatter components in the intermediate cavity theory for photon beams.

    abstract::Cavity theories are used to relate the dose in a medium to the dose in a cavity. No satisfactory analytical approach exists for the case of intermediate cavities, such as TLDs, when interface effects are important. Burlin proposed a general cavity theory that accounts for the cavity size but which ignores interface ef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/320

    authors: Frujinoiu C

    更新日期:2001-04-01 00:00:00

  • Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

    abstract::In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/N209

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,Greer PB

    更新日期:2012-06-21 00:00:00

  • Beam angle optimization for intensity-modulated radiation therapy using a guided pattern search method.

    abstract::Generally, the inverse planning of radiation therapy consists mainly of the fluence optimization. The beam angle optimization (BAO) in intensity-modulated radiation therapy (IMRT) consists of selecting appropriate radiation incidence directions and may influence the quality of the IMRT plans, both to enhance better or...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2939

    authors: Rocha H,Dias JM,Ferreira BC,Lopes MC

    更新日期:2013-05-07 00:00:00

  • Comment on 'the use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics'.

    abstract::In this letter the authors highlight the presence of an error appearing in the discussion of the note 'The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics' previously published by them (Binzoni et al 2006 Phys. Med. Biol. 51 N313). In the light of this error, the discussion ...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/51/22/L01

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-11-21 00:00:00

  • A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements.

    abstract::Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its hea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/22/010

    authors: ten Have AG,Gijsen FJ,Wentzel JJ,Slager CJ,Serruys PW,van der Steen AF

    更新日期:2006-11-21 00:00:00

  • Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy.

    abstract::A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4141

    authors: Gianoli C,Kurz C,Riboldi M,Bauer J,Fontana G,Baroni G,Debus J,Parodi K

    更新日期:2016-06-07 00:00:00

  • Comparison of SAR and induced current densities in adults and children exposed to electromagnetic fields from electronic article surveillance devices.

    abstract::Electronic article surveillance (EAS) devices are widely used in most stores as anti-theft systems. In this work, the compliance with international guidelines in the human exposure to these devices is analysed by using the finite-difference time-domain (FDTD) method. Two sets of high resolution numerical phantoms of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/009

    authors: Martínez-Búrdalo M,Sanchis A,Martín A,Villar R

    更新日期:2010-02-21 00:00:00

  • The noise power spectrum of CT images.

    abstract::An expression for the noise power spectrum of images reconstructed by the discrete filtered backprojection algorithm has been derived. The formulation explicitly includes sampling within the projections, angular sampling, and the two-dimensional sampling implicit in the discrete representation of the image. The effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/5/003

    authors: Kijewski MF,Judy PF

    更新日期:1987-05-01 00:00:00

  • The unique determination of the primary current by MEG and EEG.

    abstract::In this paper, we use a more realistic head model with ovoid geometry for approximation of a human head. By inverting the Geselowitz equation, some analytic results on the inverse MEG problem are presented in homogenous ovoid geometry. On one hand, some information about the components of primary current is shown by t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/21/012

    authors: Peng L,Cheng J,Jin L

    更新日期:2006-11-07 00:00:00

  • Analytical description of dose profile behaviour in Gamma Knife radiosurgery.

    abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/003

    authors: Fenner J,Gwilliam M,Mehrem R,Bird A,Walton L

    更新日期:2008-04-21 00:00:00

  • A modular Geant4 model of Leksell Gamma Knife Perfexion™.

    abstract::This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase spa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/24/7609

    authors: Pipek J,Novotný J,Novotný J,Kozubíková P

    更新日期:2014-12-21 00:00:00

  • Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

    abstract::Nanocarriers offer a promising approach to significantly improve therapeutic delivery to solid tumors as well as limit the side effects associated with anti-cancer agents. However, their relatively large size can negatively affect their ability to efficiently penetrate into more interior tumor regions, ultimately redu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9705

    authors: Mohammadabadi A,Huynh RN,Wadajkar AS,Lapidus RG,Kim AJ,Raub CB,Frenkel V

    更新日期:2020-06-22 00:00:00

  • Improved dose-calculation accuracy in proton treatment planning using a simplified Monte Carlo method verified with three-dimensional measurements in an anthropomorphic phantom.

    abstract::Treatment planning for proton tumor therapy requires a fast and accurate dose-calculation method. We have implemented a simplified Monte Carlo (SMC) method in the treatment planning system of the National Cancer Center Hospital East for the double-scattering beam delivery scheme. The SMC method takes into account the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/018

    authors: Hotta K,Kohno R,Takada Y,Hara Y,Tansho R,Himukai T,Kameoka S,Matsuura T,Nishio T,Ogino T

    更新日期:2010-06-21 00:00:00

  • Non-uniform depth scanning for proton therapy systems employing active energy variation.

    abstract::In proton scanning systems that employ active energy variation for depth modulation, a switch of the particle energy might typically require 1-2 s. For plans comprising many energy slices, these seconds could sum up to a non-negligible fraction of the total treatment duration. We have applied the Nyquist-Shannon sampl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/N01

    authors: Kang JH,Wilkens JJ,Oelfke U

    更新日期:2008-05-07 00:00:00

  • An integrated platform for image-guided cardiac resynchronization therapy.

    abstract::Cardiac resynchronization therapy (CRT) is an effective procedure for patients with heart failure but 30% of patients do not respond. This may be due to sub-optimal placement of the left ventricular (LV) lead. It is hypothesized that the use of cardiac anatomy, myocardial scar distribution and dyssynchrony information...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/10/2953

    authors: Ma YL,Shetty AK,Duckett S,Etyngier P,Gijsbers G,Bullens R,Schaeffter T,Razavi R,Rinaldi CA,Rhode KS

    更新日期:2012-05-21 00:00:00

  • A method of improving the spatial resolution of treatments that involve a multileaf collimator.

    abstract::In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are deliv...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/304

    authors: Evans PM,Partridge M

    更新日期:2000-03-01 00:00:00

  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • Segmented attenuation correction using artificial neural networks in positron tomography.

    abstract::The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/10/024

    authors: Yu SK,Nahmias C

    更新日期:1996-10-01 00:00:00

  • A facility for biomedical experiments with thermal neutrons.

    abstract::The Studsvik thermal-neutron facility was originally designed for neutron capture radiography (NCR) at high thermal-neutron fluence and low fast-neutron contamination. It has now been modified to permit irradiation of living cells and animals without the need for stopping and restarting the R2-0 reactor. Previous calc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/8/006

    authors: Pettersson OA,Chiangmai SN,Grusell E,Larsson B

    更新日期:1993-08-01 00:00:00

  • The assessment of the non-equilibrium effect in the 'Patlak analysis' of Fdopa PET studies.

    abstract::'Patlak analysis' is a common approach used in Fdopa PET studies to calculate the uptake constant (Ki) of the tracer. It is assumed in the Patlak analysis that the reversible compartment of tissue radioactivity used is in effective equilibrium with the tracer in plasma. Therefore, using the data prior to equilibrium i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/7/007

    authors: Yu DC,Huang SC,Barrio JR,Phelps ME

    更新日期:1995-07-01 00:00:00

  • Evaluation of the induced electric field and compliance procedure for a wireless power transfer system in an electrical vehicle.

    abstract::In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/21/7583

    authors: Laakso I,Hirata A

    更新日期:2013-11-07 00:00:00

  • Reduction of scatter in breast CT yields improved microcalcification visibility.

    abstract::The inadequate visibility of microcalcifications-small calcium deposits that cue radiologists to early stages of cancer-is a major limitation in current designs of dedicated breast computed tomography (bCT). This limitation has previously been attributed to the constituent components, spatial resolution, and utilized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae07

    authors: Ghazi P

    更新日期:2020-12-04 00:00:00

  • A search for improved technique factors in paediatric fluoroscopy.

    abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/018

    authors: Tapiovaara MJ,Sandborg M,Dance DR

    更新日期:1999-02-01 00:00:00

  • Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction.

    abstract::Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3717

    authors: Schwemmer C,Rohkohl C,Lauritsch G,Müller K,Hornegger J

    更新日期:2013-06-07 00:00:00

  • Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures.

    abstract::Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/8087

    authors: Panayiotou M,Rhode KS,King AP,Ma Y,Cooklin M,O'Neill M,Gill J,Rinaldi CA,Housden RJ

    更新日期:2015-10-21 00:00:00

  • Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

    abstract::We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/5/1361

    authors: Hirano Y,Inadama N,Yoshida E,Nishikido F,Murayama H,Watanabe M,Yamaya T

    更新日期:2013-03-07 00:00:00