Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system.

Abstract:

:The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measurements by combining the Si-PM-based PET and the 0.15 T permanent MRI to test the interferences between the Si-PM-based PET and an MRI. When the Si-PM was inside the MRI and installed around the radio frequency (RF) coil of the MRI, significant noise from the RF sequence of the MRI was observed in the analog signals of the PET detectors. However, we did not observe any artifacts in the PET images; fluctuation increased in the count rate of the Si-PM-based PET system. On the MRI side, there was significant degradation of the signal-to-noise ratio (S/N) in the MRI images compared with those without PET. By applying noise reduction procedures, the degradation of the S/N was reduced. With this condition, simultaneous measurements of a rat brain using a Si-PM-based PET and an MRI were made with some degradation in the MRI images. We conclude that simultaneous measurements are possible using Si-PM-based PET and MRI.

journal_name

Phys Med Biol

authors

Yamamoto S,Watabe T,Watabe H,Aoki M,Sugiyama E,Imaizumi M,Kanai Y,Shimosegawa E,Hatazawa J

doi

10.1088/0031-9155/57/2/N1

subject

Has Abstract

pub_date

2012-01-21 00:00:00

pages

N1-13

issue

2

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • On MEG forward modelling using multipolar expansions.

    abstract::Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/4/301

    authors: Jerbi K,Mosher JC,Baillet S,Leahy RM

    更新日期:2002-02-21 00:00:00

  • Mathematical modelling of the human cardiovascular system in the presence of stenosis.

    abstract::This paper reports a theoretical study on the distribution of blood flow in the human cardiovascular system when one or more blood vessels are affected by stenosis. The analysis employs a mathematical model of the entire system based on the finite element method. The arterial-venous network is represented by a large n...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/3/004

    authors: Sud VK,Srinivasan RS,Charles JB,Bungo MW

    更新日期:1993-03-01 00:00:00

  • A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes.

    abstract::Prompt gamma (PG) imaging is widely investigated for spot-by-spot in vivo range verification for proton therapy. Previous studies pointed out that the accuracy of prompt gamma imaging is affected by the statistics (number of protons delivered per pencil beam) of the proton beams and the conformity between prompt gamma...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7d15

    authors: Tian L,Landry G,Dedes G,Pinto M,Kamp F,Belka C,Parodi K

    更新日期:2020-04-29 00:00:00

  • 4D image reconstruction for emission tomography.

    abstract::An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/22/R371

    authors: Reader AJ,Verhaeghe J

    更新日期:2014-11-21 00:00:00

  • Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa58c9

    authors: Wang Y,Peng B,Jiang J

    更新日期:2017-03-07 00:00:00

  • Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition.

    abstract::Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R(ST) value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R(ST) concept depends on the mas...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/9/013

    authors: Wang Z,Heymsfield SB,Chen Z,Zhu S,Pierson RN

    更新日期:2010-05-07 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Iterative image-domain ring artifact removal in cone-beam CT.

    abstract::Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain variations using flat-panel detectors, and may lead to structured non-uniformities and deterioration of image quality. The purpose of this study is to propose a method of general ring artifact removal in CBCT images. This method is ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7017

    authors: Liang X,Zhang Z,Niu T,Yu S,Wu S,Li Z,Zhang H,Xie Y

    更新日期:2017-07-07 00:00:00

  • Fibre-optic sensors in health care.

    abstract::Biomedical fibre-optic sensors are attractive for the measurement of physical, chemical and biochemical parameters and for spectral measurements directly performed on the patient. An overview of fibre-optic sensors for in vivo monitoring is given, with particular attention paid to the advantages that these sensors are...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/42/5/015

    authors: Mignani AG,Baldini F

    更新日期:1997-05-01 00:00:00

  • Conical beam geometry intensity-modulated radiation therapy.

    abstract::Most commonly in radiation therapy, treatments are delivered in a co-planar geometry. Numerous advantages have been reported of adding non-coplanar beams to the treatment plan. The aim of this study was to compare current state-of-the-art VMAT and CyberKnife treatment plans to that of a novel linac design developed at...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab246f

    authors: Schüler E,Wang L,Loo BW,Maxim PG

    更新日期:2019-06-20 00:00:00

  • Impact of high dose volumetric CT on PTV margin reduction in VMAT prostate radiotherapy.

    abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab050f

    authors: Cho YB,Alasti H,Kong V,Catton C,Berlin A,Chung P,Bayley A,Jaffray D

    更新日期:2019-03-14 00:00:00

  • The response of cells in culture to fractionated radiation: a theoretical approach.

    abstract::A mathematical model has been constructed to simulate the response of cells in vitro to fractionated doses of radiation. The model is capable of describing most of the radiobiological functions that are commonly studied. Input data are measurable cell properties. The details of the model and methods of acquiring the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/5/011

    authors: Niederer J,Cunningham JR

    更新日期:1976-09-01 00:00:00

  • 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.

    abstract::When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is compl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/020

    authors: Paganetti H,Jiang H,Trofimov A

    更新日期:2005-03-07 00:00:00

  • Non-uniform depth scanning for proton therapy systems employing active energy variation.

    abstract::In proton scanning systems that employ active energy variation for depth modulation, a switch of the particle energy might typically require 1-2 s. For plans comprising many energy slices, these seconds could sum up to a non-negligible fraction of the total treatment duration. We have applied the Nyquist-Shannon sampl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/N01

    authors: Kang JH,Wilkens JJ,Oelfke U

    更新日期:2008-05-07 00:00:00

  • NEMA NU 4-2008 validation and applications of the PET-SORTEO Monte Carlo simulations platform for the geometry of the Inveon PET preclinical scanner.

    abstract::Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6749

    authors: Boisson F,Wimberley CJ,Lehnert W,Zahra D,Pham T,Perkins G,Hamze H,Gregoire MC,Reilhac A

    更新日期:2013-10-07 00:00:00

  • Development and implementation in the Monte Carlo code PENELOPE of a new virtual source model for radiotherapy photon beams and portal image calculation.

    abstract::This work aims at developing a generic virtual source model (VSM) preserving all existing correlations between variables stored in a Monte Carlo pre-computed phase space (PS) file, for dose calculation and high-resolution portal image prediction. The reference PS file was calculated using the PENELOPE code, after the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/14/5215

    authors: Chabert I,Barat E,Dautremer T,Montagu T,Agelou M,Croc de Suray A,Garcia-Hernandez JC,Gempp S,Benkreira M,de Carlan L,Lazaro D

    更新日期:2016-07-21 00:00:00

  • Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples.

    abstract::The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/020

    authors: O'Hagan JJ,Samani A

    更新日期:2009-04-21 00:00:00

  • Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

    abstract::Nanocarriers offer a promising approach to significantly improve therapeutic delivery to solid tumors as well as limit the side effects associated with anti-cancer agents. However, their relatively large size can negatively affect their ability to efficiently penetrate into more interior tumor regions, ultimately redu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9705

    authors: Mohammadabadi A,Huynh RN,Wadajkar AS,Lapidus RG,Kim AJ,Raub CB,Frenkel V

    更新日期:2020-06-22 00:00:00

  • New materials for dielectric simulation of tissues.

    abstract::Two novel materials have been developed to simulate the dielectric properties of human muscle and fat at 1000 MHz. These materials, which are based on ethanediol set with gelatine, are easily made and have good mechanical properties. The complex permittivity, epsilon *, of each material was measured with an open-ended...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/12/002

    authors: Robinson MP,Richardson MJ,Green JL,Preece AW

    更新日期:1991-12-01 00:00:00

  • Comment on 'Proton beam monitor chamber calibration'.

    abstract::We comment on a recent article (Gomà et al 2014 Phys. Med. Biol. 59 4961-71) which compares different routes of reference dosimetry for the energy dependent beam monitor calibration in scanned proton beams. In this article, a 3% discrepancy is reported between a Faraday cup and a plane-parallel ionization chamber in t...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/0031-9155/61/17/6585

    authors: Palmans H,Vatnitsky SM

    更新日期:2016-09-07 00:00:00

  • A high-sensitivity small animal SPECT system.

    abstract::Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) sy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/013

    authors: Mitchell GS,Cherry SR

    更新日期:2009-03-07 00:00:00

  • Computed temperature distributions around ectatic capillaries exposed to yellow (578 nm) laser light.

    abstract::We have numerically modelled the thermal effects of yellow (577 or 578 nm) light illumination on the ectatic blood vessels of port wine stains. We investigated the effect of the laser treatment parameters of light irradiance and illumination time on the extent of coagulation (coagulation thickness) of the endothelial ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/9/010

    authors: Pickering JW,Butler PH,Ring BJ,Walker EP

    更新日期:1989-09-01 00:00:00

  • Monitor unit calculation on the beam axis of open and wedged asymmetric high-energy photon beams.

    abstract::An ESTRO booklet and a report of the Netherlands Commission on Radiation Dosimetry have been published recently describing empirical methods for monitor unit (MU) calculations in symmetrical high-energy photon beams. Both documents support the same basic ideas; firstly the separation of head scatter and volume scatter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/12/310

    authors: Georg D

    更新日期:1999-12-01 00:00:00

  • Computational dosimetry in embryos exposed to electromagnetic plane waves over the frequency range of 10 MHz-1.5 GHz.

    abstract::This paper presents calculated specific absorption rate (SAR) dosimetry in 4 and 8 week Japanese pregnant-woman models exposed to plane waves over the frequency range of 10 MHz-1.5 GHz. Two types of 2 mm spatial-resolution pregnant-woman models comprised a woman model, which is similar to the average-sized Japanese ad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/N01

    authors: Kawai H,Nagaoka T,Watanabe S,Saito K,Takahashi M,Ito K

    更新日期:2010-01-07 00:00:00

  • Blood irradiation with accelerator produced electron beams.

    abstract::Blood and blood products are irradiated with gamma rays to reduce the risk of graft versus host disease (GVHD). A simple technique using electron beams produced by a medical linear accelerator has been studied to evaluate irradiation of blood and blood products. Variations in applied doses for a single field 20 MeV el...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/401

    authors: Butson MJ,Cheung T,Yu PK,Stokes MJ

    更新日期:2000-11-01 00:00:00

  • An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

    abstract::In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/10/010

    authors: Huang Q,Zeng GL,You J,Gullberg GT

    更新日期:2005-05-21 00:00:00

  • Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy.

    abstract::We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/8/2491

    authors: Marcatili S,Pettinato C,Daniels S,Lewis G,Edwards P,Fanti S,Spezi E

    更新日期:2013-04-21 00:00:00

  • An investigation and explanation of the fall-off of x-ray tube current during an exposure.

    abstract::It was observed that the radiation output of x-ray tubes falls off exponentially during an exposure with a time constant of about 120 ms. The equilibrium value is approximately 15% lower than that at the beginning of the exposure. The clinically noticeable consequences are discrepancies in x-ray generator calibration,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/2/004

    authors: Brezovich IA,Barnes GT

    更新日期:1980-03-01 00:00:00

  • Numerical considerations for interface reflections in medical ultrasound.

    abstract::The original concept of the echo mechanism in diagnostic medical ultrasound--of step impedance discontinuities--is investigated in terms of the numerical implications of more refined models. The effect of a discontinuity in the attenuation coefficients is found to have as much significance as the impedance discontinui...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/001

    authors: Chivers RC,Santosa F

    更新日期:1986-08-01 00:00:00

  • Dosimetric characterization of a new miniature multileaf collimator.

    abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/12/402

    authors: Hartmann GH,Föhlisch F

    更新日期:2002-06-21 00:00:00