A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes.

Abstract:

:Prompt gamma (PG) imaging is widely investigated for spot-by-spot in vivo range verification for proton therapy. Previous studies pointed out that the accuracy of prompt gamma imaging is affected by the statistics (number of protons delivered per pencil beam) of the proton beams and the conformity between prompt gamma and dose distribution (PG-dose correlation). Recently a novel approach to re-optimize conventional treatment plans by boosting a few pencil beams with good PG-dose correlation above the statistics limit for reliable PG detectability was proposed. However, up to now, only PG-dose correlation on the planning computed tomography (CT) was considered, not accounting for the fact that the robustness of the PG-dose correlation is not guaranteed in the cases of interfractional anatomical changes. In this work, this approach is further explored with respect to the robustness of the PG-dose correlation of each pencil beam in the case of interfractional anatomical changes. A research computational platform, combining Monte Carlo pre-calculated pencil beams with the analytical Matlab-based treatment planning system (TPS) CERR, is used for treatment planning. Geant4 is used for realistic simulation of the dose delivery and PG generation for all individual pencil beams in the heterogeneous patient anatomy using multiple CT images for representative patient cases (in this work, CTs of one prostate and one head and neck cancer patient are used). First, a Monte Carlo treatment plan is created using CERR. Thereby the PG emission and dose distribution for each individual spot is obtained. Second, PG-dose correlation is quantified using the originally proposed approach as well as a new indicator, which accounts for the sensitivity of individual spots to heterogeneities in the 3D dose distribution. This is accomplished by using a 2D distal surface (dose surface) derived from the 3D dose distribution for each spot. A few pencil beams are selected for each treatment field, based on their PG-dose correlation and dose surface, and then boosted in the new re-optimized treatment plan. All treatment plans are then fully re-calculated with Monte Carlo on the CT scans of the corresponding patient at three different time points. The result shows that all treatment plans are comparable in terms of dose distribution and dose averaged LET distributions. The spots recommended by our indicators maintain good PG-dose correlation in the cases of interfractional anatomical changes, thus ensuring that the proton range shift due to anatomical changes can be monitored. Compared to another proposed spots aggregation approach, our approach shows advantages in terms of the detectability and reliability of PG, especially in presence of heterogeneities.

journal_name

Phys Med Biol

authors

Tian L,Landry G,Dedes G,Pinto M,Kamp F,Belka C,Parodi K

doi

10.1088/1361-6560/ab7d15

subject

Has Abstract

pub_date

2020-04-29 00:00:00

pages

095005

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

65

pub_type

杂志文章
  • Experimental assessment of CT-based thermometry during laser ablation of porcine pancreas.

    abstract::Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/16/5705

    authors: Schena E,Saccomandi P,Giurazza F,Caponero MA,Mortato L,Di Matteo FM,Panzera F,Del Vescovo R,Beomonte Zobel B,Silvestri S

    更新日期:2013-08-21 00:00:00

  • The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy.

    abstract::The reproducibility of polyacrylamide gel (PAG) dosimetry has been evaluated when used to verify two radiotherapy treatment plans of increasing complexity. The plans investigated were a three-field coplanar arrangement, using the linac jaws for field shaping, and a four-field, conformal, non-coplanar plan using precis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/309

    authors: Cosgrove VP,Murphy PS,McJury M,Adams EJ,Warrington AP,Leach MO,Webb S

    更新日期:2000-05-01 00:00:00

  • Comparison of in vivo scintillation probes and gamma cameras for detection of small, deep tumours.

    abstract::An in vivo probe was compared with a gamma camera for the task of detecting radiolabelled tumour models in a water phantom. The probe, which contained a 1 cm diameter NaI(T1) detector, was designed and used by us for surgical staging studies of gynaecological patients. Tumours were spherical sources of different sizes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/6/008

    authors: Barber HB,Barrett HH,Woolfenden JM,Myers KJ,Hickernell TS

    更新日期:1989-06-01 00:00:00

  • Quantitative analysis of synchrotron radiation intravenous angiographic images.

    abstract::A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-st...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/50/4/011

    authors: Sarnelli A,Nemoz C,Elleaume H,Estève F,Bertrand B,Bravin A

    更新日期:2005-02-21 00:00:00

  • THz time domain spectroscopy of biomolecular conformational modes.

    abstract::We discuss the use of terahertz time domain spectroscopy for studies of conformational flexibility and conformational change in biomolecules. Protein structural dynamics are vital to biological function with protein flexibility affecting enzymatic reaction rates and sensory transduction cycling times. Conformational m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/318

    authors: Markelz A,Whitmire S,Hillebrecht J,Birge R

    更新日期:2002-11-07 00:00:00

  • A biological approach to the platelet survival curve with criticism of previous interpretations.

    abstract::The biological mechanisms of platelet destruction must be correctly identified before platelet survival curves can be interpreted. This report develops a theory of platelet destruction which is compared with experiments performed on platelets labelled with the radioactive isotope 51Cr. Platelet destruction rate is a c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/001

    authors: Trowbridge EA,Martin JF

    更新日期:1983-12-01 00:00:00

  • Real-time motion-adaptive-optimization (MAO) in TomoTherapy.

    abstract::IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/14/003

    authors: Lu W,Chen M,Ruchala KJ,Chen Q,Langen KM,Kupelian PA,Olivera GH

    更新日期:2009-07-21 00:00:00

  • Multiline 3D beamforming using micro-beamformed datasets for pediatric transesophageal echocardiography.

    abstract::Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab45e

    authors: Bera D,Raghunathan SB,Chen C,Chen Z,Pertijs MAP,Verweij MD,Daeichin V,Vos HJ,van der Steen AFW,de Jong N,Bosch JG

    更新日期:2018-03-29 00:00:00

  • A phantom for the testing and calibration of near infra-red spectrometers.

    abstract::This note describes a simple phantom which can be used to check the long term stability and accuracy of relative attenuation measurements made by near infra-red (NIR) spectrometers. The phantom has been calibrated, and the results of the calibration are shown to agree with theoretical predictions of the relative atten...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/015

    authors: Firbank M,Delpy DT

    更新日期:1994-09-01 00:00:00

  • Substituting gelatine with Pluronic F-127 matrix in 3D polymer gel dosimeters can improve nuclear magnetic resonance, thermal and optical properties.

    abstract::This work discusses the substitution of a gelatine physical gel matrix with a matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127) in five 3D radiotherapy polymer gel dosimeters: MAGAT, PAGAT, NIPAM, VIPARnd (VIP) and VIPARCT (VIC). The current research outcomes s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9d5

    authors: Jaszczak M,Wach R,Maras P,Dudek M,Kozicki M

    更新日期:2018-09-06 00:00:00

  • Analytical description of dose profile behaviour in Gamma Knife radiosurgery.

    abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/003

    authors: Fenner J,Gwilliam M,Mehrem R,Bird A,Walton L

    更新日期:2008-04-21 00:00:00

  • Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.

    abstract::109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/9/313

    authors: McNeill FE,Stokes L,Chettle DR,Kaye WE

    更新日期:1999-09-01 00:00:00

  • Evaluating attenuation correction strategies in a dedicated, single-gantry breast PET-tomosynthesis scanner.

    abstract::We are developing a dedicated, combined breast positron emission tomography (PET)-tomosynthesis scanner. Both the PET and digital breast tomosynthesis (DBT) scanners are integrated in a single gantry to provide spatially co-registered 3D PET-tomosynthesis images. The DBT image will be used to identify the breast bound...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5a8

    authors: Krishnamoorthy S,Vent T,Barufaldi B,Maidment ADA,Karp JS,Surti S

    更新日期:2020-10-28 00:00:00

  • Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT.

    abstract::Optimization-based algorithms for image reconstruction in multispectral (or photon-counting) computed tomography (MCT) remains a topic of active research. The challenge of optimization-based image reconstruction in MCT stems from the inherently non-linear data model that can lead to a non-convex optimization program f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a4b

    authors: Chen B,Zhang Z,Sidky EY,Xia D,Pan X

    更新日期:2017-11-02 00:00:00

  • Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization.

    abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2838

    authors: Gao H

    更新日期:2016-04-07 00:00:00

  • Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films.

    abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8bf3

    authors: Kawashima M,Matsumura A,Souda H,Tashiro M

    更新日期:2020-06-15 00:00:00

  • The biomechanics of simple steatosis and steatohepatitis.

    abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac09a

    authors: Parker KJ,Ormachea J,Drage MG,Kim H,Hah Z

    更新日期:2018-05-17 00:00:00

  • Accuracy of quantitative reconstructions in SPECT/CT imaging.

    abstract::The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/009

    authors: Shcherbinin S,Celler A,Belhocine T,Vanderwerf R,Driedger A

    更新日期:2008-09-07 00:00:00

  • GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.

    abstract::In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/4987

    authors: Lemaréchal Y,Bert J,Falconnet C,Després P,Valeri A,Schick U,Pradier O,Garcia MP,Boussion N,Visvikis D

    更新日期:2015-07-07 00:00:00

  • Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

    abstract::Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa26

    authors: Giger AT,Krieger M,Jud C,Duetschler A,Salomir R,Bieri O,Bauman G,Nguyen D,Weber DC,Lomax AJ,Zhang Y,Cattin PC

    更新日期:2020-07-28 00:00:00

  • Potential applications of the quantitative susceptibility mapping (QSM) in MR-guided radiation therapy.

    abstract::Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2623

    authors: Nosrati R,Paudel M,Ravi A,Pejovic-Milic A,Morton G,Stanisz GJ

    更新日期:2019-07-16 00:00:00

  • Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

    abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1325

    authors: Anizan N,Wang H,Zhou XC,Wahl RL,Frey EC

    更新日期:2015-02-07 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • Spectral characterization of local magnetic field inhomogeneities.

    abstract::The purpose of this study was the characterization of local magnetic susceptibility deviations by spectral analysis of their induced magnetic field inhomogeneities. Magnetic resonance spectra and related signal decay curves of local susceptibility deviations were simulated for different volume fractions and compositio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/2/013

    authors: Seppenwoolde JH,van Zijtveld M,Bakker CJ

    更新日期:2005-01-21 00:00:00

  • Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT.

    abstract::A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4476

    authors: Salas-Ramirez M,Tran-Gia J,Gbureck U,Kosmala A,Lassmann M

    更新日期:2019-10-16 00:00:00

  • Monte Carlo simulation to evaluate the contamination in an energy modulated carbon ion beam for hadron therapy delivered by cyclotron.

    abstract::Protons and carbon ion beams for hadron therapy can be delivered by cyclotrons with a fixed energy. In order to treat patients, an energy degrader along the beam line will be used to match the particle range with the target depth. Fragmentation reactions of carbon ions inside the degrader material could introduce a sm...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/21/010

    authors: Morone MC,Calabretta L,Cuttone G,Fiorini F

    更新日期:2008-11-07 00:00:00

  • Effects of injected dose, BMI and scanner type on NECR and image noise in PET imaging.

    abstract::Noise equivalent count rate (NECR) and image noise are two different but related metrics that have been used to predict and assess image quality, respectively. The aim of this study is to investigate, using patient studies, the relationships between injected dose (ID), body mass index (BMI) and scanner type on NECR an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/013

    authors: Chang T,Chang G,Kohlmyer S,Clark JW,Rohren E,Mawlawi OR

    更新日期:2011-08-21 00:00:00

  • Beam characterisation of the 1.5 T MRI-linac.

    abstract::As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab566

    authors: Woodings SJ,Bluemink JJ,de Vries JHW,Niatsetski Y,van Veelen B,Schillings J,Kok JGM,Wolthaus JWH,Hackett SL,van Asselen B,van Zijp HM,Pencea S,Roberts DA,Lagendijk JJW,Raaymakers BW

    更新日期:2018-04-19 00:00:00

  • Inverse planning for functional image-guided intensity-modulated radiation therapy.

    abstract::Radiation therapy is an image-guided process whose success critically depends on the imaging modality used for treatment planning and the level of integration of the available imaging information. In this work, we establish a dose optimization framework for incorporating metabolic information from functional imaging m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/20/301

    authors: Xing L,Cotrutz C,Hunjan S,Boyer AL,Adalsteinsson E,Spielman D

    更新日期:2002-10-21 00:00:00

  • Effective energy resolution and scatter rejection in nuclear medicine.

    abstract::All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/1/008

    authors: Wirth V

    更新日期:1989-01-01 00:00:00