Effective energy resolution and scatter rejection in nuclear medicine.

Abstract:

:All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's intrinsic energy resolution would reduce the amount of detected scattered radiation as well. A simple model was developed in order to simulate the influence of the energy resolution on the camera response. It is shown that improvement of the energy resolution and scatter correction schemes have a similar effect on the point spread function. On this basis, it is suggested that 'effective energy resolution' be used as a new measure for the effectiveness of scatter correction schemes. As an example, this is done for energy-weighted acquisition (EWA), a scheme wherein each event contributes imaging information according to a real-valued, energy-indexed weighting function.

journal_name

Phys Med Biol

authors

Wirth V

doi

10.1088/0031-9155/34/1/008

subject

Has Abstract

pub_date

1989-01-01 00:00:00

pages

85-90

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

34

pub_type

杂志文章
  • Influence of source parameters on large-field electron beam profiles calculated using Monte Carlo methods.

    abstract::The purpose of this paper was to study the source model for a Monte Carlo simulation of electron beams from a medical linear accelerator. In a prior study, a non-divergent Gaussian source with a full-width at half-maximum (FWHM) of 0.15 cm was successful in predicting relative dose distributions for electron beams wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/007

    authors: Weinberg R,Antolak JA,Starkschall G,Kudchadker RJ,White RA,Hogstrom KR

    更新日期:2009-01-07 00:00:00

  • Computed temperature distributions around ectatic capillaries exposed to yellow (578 nm) laser light.

    abstract::We have numerically modelled the thermal effects of yellow (577 or 578 nm) light illumination on the ectatic blood vessels of port wine stains. We investigated the effect of the laser treatment parameters of light irradiance and illumination time on the extent of coagulation (coagulation thickness) of the endothelial ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/9/010

    authors: Pickering JW,Butler PH,Ring BJ,Walker EP

    更新日期:1989-09-01 00:00:00

  • Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancer.

    abstract::Image-guided radiation therapy using implanted fiducial markers is a common solution for prostate localization to improve targeting accuracy. However, fiducials that are typically used for conventional photon radiotherapy cause large dose perturbations in patients who receive proton radiotherapy. A proposed solution h...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/S13

    authors: Cheung J,Kudchadker RJ,Zhu XR,Lee AK,Newhauser WD

    更新日期:2010-12-07 00:00:00

  • Simulations of a micro-PET system based on liquid xenon.

    abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/6/1685

    authors: Miceli A,Glister J,Andreyev A,Bryman D,Kurchaninov L,Lu P,Muennich A,Retiere F,Sossi V

    更新日期:2012-03-21 00:00:00

  • The Fokker-Planck equation for coupled Brown-Néel-rotation.

    abstract::Calculating the dynamic properties of magnetization of single-domain particles is of great importance for the tomographic imaging modality known as magnetic particle imaging (MPI). Although the assumption of instantaneous thermodynamic equilibrium (Langevin function) after application of time-dependent magnetic fields...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa186

    authors: Weizenecker J

    更新日期:2018-01-22 00:00:00

  • Treatment plan modification using voxel-based weighting factors/dose prescription.

    abstract::Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/315

    authors: Wu C,Olivera GH,Jeraj R,Keller H,Mackie TR

    更新日期:2003-08-07 00:00:00

  • Elastography--the movement begins.

    abstract::The advent of real-time ultrasound in the 1970s, together with a growing interest in tissue characterization, led to a number of investigators using the nature of tissue motion to distinguish healthy from diseased tissue. Our group at the (then) Ultrasonics Institute demonstrated the use of phase methods for detecting...

    journal_title:Physics in medicine and biology

    pub_type: 历史文章,杂志文章

    doi:10.1088/0031-9155/45/6/301

    authors: Wilson LS,Robinson DE,Dadd MJ

    更新日期:2000-06-01 00:00:00

  • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.

    abstract::The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast. The conversion factors currently used were obtained by computer simulation of a model breast with a composition of 50% adipose and 50% glandular tissues by ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/308

    authors: Dance DR,Skinner CL,Young KC,Beckett JR,Kotre CJ

    更新日期:2000-11-01 00:00:00

  • Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method.

    abstract::Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories throu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/013

    authors: Bodammer NC,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2009-02-21 00:00:00

  • Impact of the displacement current on low-frequency electromagnetic fields computed using high-resolution anatomy models.

    abstract::We present a comparison of simulated low-frequency electromagnetic fields in the human body, calculated by means of the electro-quasistatic formulation. The geometrical data in these simulations were provided by an anatomically realistic, high-resolution human body model, while the dielectric properties of the various...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/N02

    authors: Barchanski A,De Gersem H,Gjonaj E,Weiland T

    更新日期:2005-10-07 00:00:00

  • Dual energy x-ray laser measurement of calcaneal bone mineral density.

    abstract::In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/305

    authors: Hakulinen MA,Saarakkala S,Töyräs J,Kröger H,Jurvelin JS

    更新日期:2003-06-21 00:00:00

  • The dosimetric impact of dental implants on head-and-neck volumetric modulated arc therapy.

    abstract::This work aims to investigate the dosimetric impact of dental implants on volumetric modulated arc therapy (VMAT) for head-and-neck patients and to evaluate the effectiveness of using the material's electron-density ratio for the correction. An in-house Monte Carlo (MC) code was utilized for the dose calculation to ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1027

    authors: Lin MH,Li J,Price RA Jr,Wang L,Lee CC,Ma CM

    更新日期:2013-02-21 00:00:00

  • Variability among polysulphone calibration curves.

    abstract::Within an epidemiological study regarding the correlation between skin pathologies and personal ultraviolet (UV) exposure due to solar radiation, 14 field campaigns using polysulphone (PS) dosemeters were carried out at three different Italian sites (urban, semi-rural and rural) in every season of the year. A polysulp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/019

    authors: Casale GR,Borra M,Colosimo A,Colucci M,Militello A,Siani AM,Sisto R

    更新日期:2006-09-07 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • Verification of the super-omni wedge concept.

    abstract::This study verifies the concept of the super-omni wedge by validating its equations for effective wedge orientation and wedge angle and by comparing the dose distributions it produces with those produced by other wedge techniques. To validate the equations, we calculated dose distributions for 20 combinations of wedge...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/9/313

    authors: Dai J,Zhu Y,Wu X

    更新日期:2001-09-01 00:00:00

  • Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.

    abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/013

    authors: Edwards CR,Mountford PJ,Moloney AJ

    更新日期:2006-12-21 00:00:00

  • Quantitative evaluation of regularized phase retrieval algorithms on bone scaffolds seeded with bone cells.

    abstract::In the field of regenerative medicine, there has been a growing interest in studying the combination of bone scaffolds and cells that can maximize newly formed bone. In-line phase-contrast x-ray tomography was used to image porous bone scaffolds (Skelite(©)), seeded with bone forming cells. This technique allows the q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/9/N215

    authors: Weber L,Langer M,Tavella S,Ruggiu A,Peyrin F

    更新日期:2016-05-07 00:00:00

  • The energy-dependent electron loss model for pencil beam dose kernels.

    abstract::The 'monoenergetic' electron loss model was derived in a previous work to account for pathlength straggling in the Fermi-Eyges pencil beam problem. In this paper, we extend this model to account for energy-loss straggling and secondary knock-on electron transport in order to adequately predict a depth dose curve. To m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/313

    authors: Chvetsov AV,Sandison GA,Yeboah C

    更新日期:2000-10-01 00:00:00

  • Real-time prediction and gating of respiratory motion using an extended Kalman filter and Gaussian process regression.

    abstract::Motion-adaptive radiotherapy aims to deliver a conformal dose to the target tumour with minimal normal tissue exposure by compensating for tumour motion in real time. The prediction as well as the gating of respiratory motion have received much attention over the last two decades for reducing the targeting error of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/233

    authors: Bukhari W,Hong SM

    更新日期:2015-01-07 00:00:00

  • Dictionary learning for data recovery in positron emission tomography.

    abstract::Compressed sensing (CS) aims to recover images from fewer measurements than that governed by the Nyquist sampling theorem. Most CS methods use analytical predefined sparsifying domains such as total variation, wavelets, curvelets, and finite transforms to perform this task. In this study, we evaluated the use of dicti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/15/5853

    authors: Valiollahzadeh S,Clark JW,Mawlawi O

    更新日期:2015-08-07 00:00:00

  • The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

    abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/313

    authors: Wolf M,Keel M,Dietz V,von Siebenthal K,Bucher HU,Baenziger O

    更新日期:1999-07-01 00:00:00

  • Mathematical modelling of the human cardiovascular system in the presence of stenosis.

    abstract::This paper reports a theoretical study on the distribution of blood flow in the human cardiovascular system when one or more blood vessels are affected by stenosis. The analysis employs a mathematical model of the entire system based on the finite element method. The arterial-venous network is represented by a large n...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/3/004

    authors: Sud VK,Srinivasan RS,Charles JB,Bungo MW

    更新日期:1993-03-01 00:00:00

  • Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine.

    abstract::In this paper we present the results of a dosimetric evaluation of a 2D ionization chamber array with the objective of its implementation for quality assurance in clinical routine. The pixel ionization chamber MatriXX (Scanditronix Wellhofer, Germany) consists of 32x32 chambers with a distance of 7.6 mm between chambe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/023

    authors: Herzen J,Todorovic M,Cremers F,Platz V,Albers D,Bartels A,Schmidt R

    更新日期:2007-02-21 00:00:00

  • Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy.

    abstract::The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/006

    authors: Anderson JW,Symonds-Tayler R,Hartmann G,Echner G,Lang C,Schlegel W,Webb S

    更新日期:2006-04-07 00:00:00

  • A robust optimization method for weighted-layer-stacking proton beam therapy.

    abstract::The layer-stacking method can provide three-dimensional conformal dose distributions to the target based on a passive scattering method using mini-spread-out Bragg peak (SOBP). The purpose of this work is to demonstrate the effectiveness of a new weight optimization algorithm that can enhance the robustness of dose di...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9efd

    authors: Sakamoto Y,Maeda Y,Yamada Y,Ikeda M,Tameshige Y,Sasaki M,Shibata S,Yamamoto K

    更新日期:2020-09-28 00:00:00

  • Use of forward projection to correct patient motion during SPECT imaging.

    abstract::We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the proce...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/011

    authors: Lee KJ,Barber DC

    更新日期:1998-01-01 00:00:00

  • Characterization of diffraction-enhanced imaging contrast in breast cancer.

    abstract::Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that has been shown to enhance contrast between normal and cancerous breast tissues. In this study, diffraction-enhanced imaging in computed tomography (DEI-CT) mode was used to quantitatively characterize the refraction contrasts of the organized stru...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/019

    authors: Kao T,Connor D,Dilmanian FA,Faulconer L,Liu T,Parham C,Pisano ED,Zhong Z

    更新日期:2009-05-21 00:00:00

  • FBP-Net for direct reconstruction of dynamic PET images.

    abstract::Dynamic positron emission tomography (PET) imaging can provide information about metabolic changes over time, used for kinetic analysis and auxiliary diagnosis. Existing deep learning-based reconstruction methods have too many trainable parameters and poor generalization, and require mass data to train the neural netw...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc09d

    authors: Wang B,Liu H

    更新日期:2020-10-13 00:00:00

  • 19F MRI oximetry: simulation of perfluorocarbon distribution impact.

    abstract::In (19)F MRI oximetry, a method used to image tumour hypoxia, perfluorocarbons serve as oxygenation markers. The goal of this study is to evaluate the impact of perfluorocarbon distribution and concentration in (19)F MRI oximetry through a computer simulation. The simulation studies the correspondence between (19)F me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/013

    authors: Baete SH,Vandecasteele J,De Deene Y

    更新日期:2011-04-21 00:00:00

  • Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.

    abstract::Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/N02

    authors: Klüter S,Sroka-Perez G,Schubert K,Debus J

    更新日期:2011-01-21 00:00:00