Abstract:
:In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by combining DXA and heel thickness measurements. In the present study, 38 subjects were measured with DXL Calscan, Lunar PIXI and Lunar DPX-IQ DXA instruments and Hologic Sahara ultrasound instrument, and the performance and agreement of the instruments were analysed. Furthermore, numerical simulations on the effect of non-uniform fat-to-lean tissue ratio within soft tissue in heel were conducted. In vivo short-term precision (CV%, sCV%) of DXL Calscan (1.24%, 1.48%) was similar to that of Lunar PIXI (1.28%, 1.60%). Calcaneal areal bone mineral densities (BMD, g cm(-2)) measured using DXL Calscan and Lunar PIXI predicted equally well variations in BMD of femoral neck (r2 = 0.63 and 0.52, respectively) or lumbar spine (r2 = 0.61 and 0.64, respectively), determined with Lunar DPX-IQ. BMD values measured with DXL Calscan were, on average, 19% lower (p < 0.01) than those determined with Lunar PIXI. Interestingly, the difference in BMD values between instruments increased as a function of body mass index (BMI) (r2 = 0.17, p < 0.02) or heel thickness (r2 = 0.37, p < 0.01). Numerical simulations suggested that the spatial variation of soft tissue composition in heel can induce incontrollable inaccuracy in BMD when measured with the DXA technique. Theoretically, in contrast to DXA instruments, elimination of the effect of non-uniform soft tissue is possible with DXL Calscan.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Hakulinen MA,Saarakkala S,Töyräs J,Kröger H,Jurvelin JSdoi
10.1088/0031-9155/48/12/305subject
Has Abstractpub_date
2003-06-21 00:00:00pages
1741-52issue
12eissn
0031-9155issn
1361-6560journal_volume
48pub_type
杂志文章abstract::Data filtering is crucial for accurate relative stopping power (RSP) reconstruction in proton CT (pCT). In this work, we assess different filters and their performance for the US pCT collaboration prototype pCT system in Monte Carlo (MC) simulations. The potential of using the recently proposed [Formula: see text]-E f...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2671
更新日期:2019-08-01 00:00:00
abstract::Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/51/13/R02
更新日期:2006-07-07 00:00:00
abstract::The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/17/009
更新日期:2008-09-07 00:00:00
abstract::Dynamic modulation can be affected by inaccuracies when the required acceleration is larger than the highest allowed by the mechanical characteristics of the whole apparatus. In this study, inertia effects have been investigated with regard to the single absorber 1D modulation, analysing primarily how the acceleration...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/11/401
更新日期:1999-11-01 00:00:00
abstract::An open-ended coaxial probe is often used for investigating the dielectric properties of biological tissues. The present study indicates that in addition to the probe size, the penetration of the electromagnetic (EM) fields of an open-ended coaxial probe in contact with the skin is dependent on the applied frequency b...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/7/404
更新日期:1999-07-01 00:00:00
abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/021
更新日期:1998-05-01 00:00:00
abstract::We have shown that irradiation changes the dielectric properties of human skin at radiofrequencies. Both the dielectric constant and the conductivity of the irradiated skin decrease, especially at low frequencies. The experimental data were analysed using two bioelectric models. Relevant dielectric parameters were det...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/6/001
更新日期:1994-06-01 00:00:00
abstract::Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional par...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/4/301
更新日期:2002-02-21 00:00:00
abstract::Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PB...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/5/1147
更新日期:2012-03-07 00:00:00
abstract::Respiratory research with mice using micro-computed tomography (micro-CT) has been predominantly hindered by the limited resolution and signal-to-noise ratio (SNR) as a result of respiratory motion artefacts. In this study, we develop a novel technique for capturing the lung microstructure in vivo using micro-CT, thro...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/23/008
更新日期:2006-12-07 00:00:00
abstract::We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the proce...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/1/011
更新日期:1998-01-01 00:00:00
abstract::Radiation dose distributions have been calculated for 188Re and 32P activity on a coronary artery stent. The doses have been calculated both as a function of position along the stent and of depth into the artery wall. Comparisons of the dose from identical activities of 188Re and 32P on the stent show that the major d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/12/310
更新日期:2000-12-01 00:00:00
abstract::Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain variations using flat-panel detectors, and may lead to structured non-uniformities and deterioration of image quality. The purpose of this study is to propose a method of general ring artifact removal in CBCT images. This method is ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa7017
更新日期:2017-07-07 00:00:00
abstract::An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) fo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/13/4643
更新日期:2013-07-07 00:00:00
abstract::For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of det...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/19/002
更新日期:2008-10-07 00:00:00
abstract::DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA s...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/7/1789
更新日期:2014-04-07 00:00:00
abstract::Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an ac...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/18/311
更新日期:2002-09-21 00:00:00
abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/11/014
更新日期:2005-06-07 00:00:00
abstract::Clinical cerebral blood flow (CBF) maps generated through dynamic- susceptibility contrast (DSC) magnetic resonance (MR) perfusion imaging are currently cross-calibrated with PET studies. The cross-calibration is achieved by rescaling the MR CBF values so that normal white matter CBF corresponds to 22 ml/100 g/min. Ex...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/6/014
更新日期:2005-03-21 00:00:00
abstract::State of the art point-spread function (PSF) corrections implemented in positron emission tomography/computed tomography (PET/CT) reconstruction improved image quality and diagnostic performance but caused an increase in the standardized uptake value (SUV) compared to a conventional OSEM reconstruction system. The EAN...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaee27
更新日期:2018-11-26 00:00:00
abstract::Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/10/N03
更新日期:2007-05-21 00:00:00
abstract::Computed tomography images have been acquired using an experimental (low atomic number (Z) insert) megavoltage cone-beam imaging system. These images have been compared with standard megavoltage and kilovoltage imaging systems. The experimental system requires a simple modification to the 4 MeV electron beam from an E...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/14/014
更新日期:2011-07-21 00:00:00
abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/17/4961
更新日期:2014-09-07 00:00:00
abstract::Spectral x-ray imaging using novel photon counting x-ray detectors (PCDs) with energy resolving abilities is capable of providing energy-selective images. PCDs have energy thresholds, enabling the classification of photons into multiple energy bins. The extra energy information provided may allow materials such as iod...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/18/012
更新日期:2011-09-21 00:00:00
abstract::Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9774
更新日期:2020-08-31 00:00:00
abstract::Avoiding toxicities in radiotherapy requires the knowledge of tolerable organ doses. For new, experimental fractionation schemes (e.g. hypofractionation) these are typically derived from traditional schedules using the biologically effective dose (BED) model. In this report we investigate the difficulties of establish...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa9836
更新日期:2018-02-05 00:00:00
abstract::It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the v...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5b72
更新日期:2017-03-21 00:00:00
abstract::In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been common practice for efficient operation, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. Treatments are usually fractionated and treatment plans are ev...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/3/1062
更新日期:2017-02-07 00:00:00
abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac09a
更新日期:2018-05-17 00:00:00
abstract::An in vivo method for the determination of Cd levels in human kidney and liver has been developed. The method allows detection of absolute quantities of Cd in the left kidney and Cd concentration in the liver. The limit of detection of cadmium is 2.5 mg for the left kidney and 1.8 microgram/g (wet weight) for the live...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/22/6/003
更新日期:1977-11-01 00:00:00