Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology.

Abstract:

:Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image transmission, most of which are included in a picture archiving and communication system (PACS). The content of this paper includes a short review of research and development in medical imaging science and technology, which covers (a) diagnostic imaging in the 1950s, (b) the importance of image quality and diagnostic performance, (c) MTF, Wiener spectrum, NEQ and DQE, (d) ROC analysis, (e) analogue imaging systems, (f) digital imaging systems, (g) image processing, (h) computer-aided diagnosis, (i) PACS, (j) 3D imaging and (k) future directions. Although some of the modalities are already very sophisticated, further improvements will be made in image quality for MRI, ultrasound and molecular imaging. The infrastructure of PACS is likely to be improved further in terms of its reliability, speed and capacity. However, CAD is currently still in its infancy, and is likely to be a subject of research for a long time.

journal_name

Phys Med Biol

authors

Doi K

doi

10.1088/0031-9155/51/13/R02

subject

Has Abstract

pub_date

2006-07-07 00:00:00

pages

R5-27

issue

13

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(06)96769-4

journal_volume

51

pub_type

杂志文章,评审
  • Infrasonic analysis of carotid vibration as a diagnostic method in carotid insufficiency syndrome.

    abstract::The infrasonic part of the spectrum of the carotid artery wall vibration in the neck was obtained. Differences between the spectral content and vibrational amplitude in normal and occluded carotids were found. The application of this technique in clinical practice could be useful in the detection of the carotid insuff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/011

    authors: Anastassiades AJ,Petounis AD

    更新日期:1976-01-01 00:00:00

  • Impedance magnetocardiogram.

    abstract::We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart--the so-called magnetocardiogram (MCG)--can be simultaneously detected by using this system. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/403

    authors: Kandori A,Miyashita T,Suzuki D,Yokosawa K,Tsukada K

    更新日期:2001-02-01 00:00:00

  • Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures.

    abstract::Our goal was to develop a method for generating high-resolution three-dimensional pulmonary compliance images in rodents from computed tomography (CT) images acquired at a series of constant pressures in ventilated animals. One rat and one mouse were used to demonstrate this technique. A pre-clinical GE flat panel CT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/003

    authors: Guerrero T,Castillo R,Sanders K,Price R,Komaki R,Cody D

    更新日期:2006-03-07 00:00:00

  • Analytical description of dose profile behaviour in Gamma Knife radiosurgery.

    abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/003

    authors: Fenner J,Gwilliam M,Mehrem R,Bird A,Walton L

    更新日期:2008-04-21 00:00:00

  • Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method.

    abstract::We propose a retrospective respiratory gating algorithm to generate dynamic CT studies. To this end, we compared three different methods of extracting the respiratory signal from the projections of small-animal cone-beam computed tomography (CBCT) scanners. Given a set of frames acquired from a certain axial angle, su...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/015

    authors: Chavarrías C,Vaquero JJ,Sisniega A,Rodríguez-Ruano A,Soto-Montenegro ML,García-Barreno P,Desco M

    更新日期:2008-09-07 00:00:00

  • Radiobiological aspects of supralinear photographic emulsions.

    abstract::Nuclear emulsions of the Ilford K series, exposed to X-rays from 15 to 150 kVp and systematically underdeveloped, exhibit supralinear blackness--exposure curves ranging from 1- to 4-hit in character, and whose shape is the same at all excitation voltages. Processing can be so adjusted that the curve shape is well repr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/6/007

    authors: Katz R,Pennington EC

    更新日期:1978-11-01 00:00:00

  • Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403).

    abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/51/21/002

    authors: Nishio T,Kunieda E,Shirato H,Ishikura S,Onishi H,Tateoka K,Hiraoka M,Narita Y,Ikeda M,Goka T

    更新日期:2006-11-07 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • New compensator design options for charged-particle radiotherapy.

    abstract::The purpose of this investigation is to propose new compensator design strategies for protons and heavier particles which are based on pencil-beam (PB) dose calculations and which significantly reduce the dose to tissues downstream from the target, yet provide acceptable target coverage under conditions of patient mot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/7/005

    authors: Petti PL

    更新日期:1997-07-01 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • The electromagnetic response of human skin in the millimetre and submillimetre wave range.

    abstract::Recent studies of the minute morphology of the skin by optical coherence tomography revealed that the sweat ducts in human skin are helically shaped tubes, filled with a conductive aqueous solution. This, together with the fact that the dielectric permittivity of the dermis is higher than that of the epidermis, brings...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/11/005

    authors: Feldman Y,Puzenko A,Ben Ishai P,Caduff A,Davidovich I,Sakran F,Agranat AJ

    更新日期:2009-06-07 00:00:00

  • Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles.

    abstract::The objective of this work is to test analytical models to calculate the luminescence efficiency of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to heavy charged particles with energies relevant to space dosimetry and particle therapy. We used the track structure model to obtain an analytica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/437

    authors: Sawakuchi GO,Yukihara EG

    更新日期:2012-01-21 00:00:00

  • The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    abstract::The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling;...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9a2f

    authors: Simon JC,Sapozhnikov OA,Kreider W,Breshock M,Williams JC,Bailey MR

    更新日期:2018-01-09 00:00:00

  • Why should breast tumour detection go three dimensional?

    abstract::Although x-ray mammography is widely developed for breast tumour detection, it suffers from spatial superposition in its two-dimensional (2D) representation of a three-dimensional (3D) breast structure. Accordingly, 3D breast imaging, such as cone-beam computed tomography (CT), arises at the historic moment. In this p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/14/312

    authors: Chen Z,Ning R

    更新日期:2003-07-21 00:00:00

  • An analysis of beam parameters on proton-acoustic waves through an analytic approach.

    abstract::It has been reported that acoustic waves are generated when a high-energy pulsed proton beam is deposited in a small volume within tissue. One possible application of proton-induced acoustics is to get real-time feedback for intra-treatment adjustments by monitoring such acoustic waves. A high spatial resolution in ul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa642c

    authors: Kipergil EA,Erkol H,Kaya S,Gulsen G,Unlu MB

    更新日期:2017-06-21 00:00:00

  • The observation and analysis of cancer deaths among classified radiation workers.

    abstract::The extent to which occupational radiation exposure contributes to cancer mortality is an influence on future world energy policy. It is also a factor in deciding the level of expenditure to reduce radiation levels experienced by workers. Here we discuss some of the difficulties in analysing the situation and presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/6/001

    authors: Reissland JA,Kay P,Dolphin GW

    更新日期:1976-11-01 00:00:00

  • The fast Padé transform in magnetic resonance spectroscopy for potential improvements in early cancer diagnostics.

    abstract::The convergence rates of the fast Padé transform (FPT) and the fast Fourier transform (FFT) are compared. These two estimators are used to process a time-signal encoded at 4 T by means of one-dimensional magnetic resonance spectroscopy (MRS) for healthy human brain. It is found systematically that at any level of trun...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/010

    authors: Belkić D,Belkić K

    更新日期:2005-09-21 00:00:00

  • A comparison between the patella and the calcaneus using ultrasound velocity and attenuation as predictors of bone mineral density.

    abstract::The bone mineral density (BMD), ultrasound velocity (UV) and attenuation were examined in sixteen matched sets of human patellae and calcanei. For the sixteen calcanei, BMD was strongly correlated with all ultrasound parameters. Calcaneal UV appeared to be inferior to attenuation in the ability to predict BMD. For the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/10/008

    authors: Han SM,Davis J

    更新日期:1997-10-01 00:00:00

  • Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty.

    abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/15/003

    authors: Ploquin N,Song W,Lau H,Dunscombe P

    更新日期:2005-08-07 00:00:00

  • Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator.

    abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1375

    authors: Bol GH,Hissoiny S,Lagendijk JJ,Raaymakers BW

    更新日期:2012-03-07 00:00:00

  • Elastostatics of a spherical inclusion in homogeneous biological media.

    abstract::A three-dimensional spherical inclusion model that approximates a lesion bonded to a tissue matrix is proposed for biomedical elastography. Analytical formulae describing spatial strain and stress distributions generated in infinite media by uniform loading are given under a linear, homogeneous, isotropic elasticity a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/001

    authors: Bilgen M,Insana MF

    更新日期:1998-01-01 00:00:00

  • Use of forward projection to correct patient motion during SPECT imaging.

    abstract::We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the proce...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/011

    authors: Lee KJ,Barber DC

    更新日期:1998-01-01 00:00:00

  • Comparison of two-compartment exchange and continuum models of dMRI in skeletal muscle.

    abstract::Clinical diffusion MRI (dMRI) is sensitive to micrometer scale spin displacements, but the image resolution is  ∼mm, so the biophysical interpretation of the signal relies on establishing appropriate subvoxel tissue models. A class of two-compartment exchange models originally proposed by Kärger have been used success...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2aa6

    authors: Naughton NM,Georgiadis JG

    更新日期:2019-08-01 00:00:00

  • High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

    abstract::Cone-beam computed tomography (CBCT) has been clinically used to verify patient position and to localize the target of treatment in image-guided radiation therapy (IGRT). However, when the chest and the upper abdomen are scanned, respiratory-induced motion blurring limits the utility of CBCT. In order to mitigate this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/006

    authors: Leng S,Tang J,Zambelli J,Nett B,Tolakanahalli R,Chen GH

    更新日期:2008-10-21 00:00:00

  • An automatic algorithm to exploit the symmetries of the system response matrix in positron emission tomography iterative reconstruction.

    abstract::Positron emission tomography (PET) iterative 3D reconstruction is a very computational demanding task. One of the main issues of the iterative reconstruction concerns the management of the system response matrix (SRM). The SRM models the relationship between the projection and the voxel space and its memory footprint ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae12b

    authors: Camarlinghi N,Sportelli G,Guerra AD,Belcari N

    更新日期:2018-09-28 00:00:00

  • Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography.

    abstract::The incorporation of accurately aligned anatomical information as a prior to guide reconstruction and noise regularization in positron emission tomography (PET) has been suggested in many previous studies. However, the advantages of this approach can only be realized if the exact lesion outline is also available. In p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/24/009

    authors: Chan C,Fulton R,Feng DD,Meikle S

    更新日期:2009-12-21 00:00:00

  • Energy-resolved computed tomography: first experimental results.

    abstract::First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/002

    authors: Shikhaliev PM

    更新日期:2008-10-21 00:00:00

  • Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcdb

    authors: Lee H,Yeom YS,Nguyen TT,Choi C,Han H,Shin B,Zhang X,Kim CH,Chung BS,Zankl M

    更新日期:2019-02-05 00:00:00

  • Laboratory prototype for experimental validation of MR-guided radiofrequency head and neck hyperthermia.

    abstract::Clinical studies have established a strong benefit from adjuvant mild hyperthermia (HT) to radio- and chemotherapy for many tumor sites, including the head and neck (H&N). The recently developed HYPERcollar allows the application of local radiofrequency HT to tumors in the entire H&N. Treatment quality is optimized us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2139

    authors: Paulides MM,Bakker JF,Hofstetter LW,Numan WC,Pellicer R,Fiveland EW,Tarasek M,Houston GC,van Rhoon GC,Yeo DT,Kotek G

    更新日期:2014-05-07 00:00:00

  • Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols.

    abstract::A formalism is proposed for the estimation of mean glandular dose for breast tomosynthesis, which is a simple extension of the UK, European and IAEA protocols for dosimetry in conventional projection mammography. The formalism introduces t-factors for the calculation of breast dose from a single projection and T-facto...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/011

    authors: Dance DR,Young KC,van Engen RE

    更新日期:2011-01-21 00:00:00