Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms.

Abstract:

:It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.

journal_name

Phys Med Biol

authors

Kim HS,Yeom YS,Nguyen TT,Choi C,Han MC,Lee JK,Kim CH,Zankl M,Petoussi-Henss N,Bolch WE,Lee C,Qiu R,Eckerman K,Chung BS

doi

10.1088/1361-6560/aa5b72

subject

Has Abstract

pub_date

2017-03-21 00:00:00

pages

2132-2152

issue

6

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • Why should breast tumour detection go three dimensional?

    abstract::Although x-ray mammography is widely developed for breast tumour detection, it suffers from spatial superposition in its two-dimensional (2D) representation of a three-dimensional (3D) breast structure. Accordingly, 3D breast imaging, such as cone-beam computed tomography (CT), arises at the historic moment. In this p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/14/312

    authors: Chen Z,Ning R

    更新日期:2003-07-21 00:00:00

  • Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy.

    abstract::Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/24/7865

    authors: Flach B,Brehm M,Sawall S,Kachelrieß M

    更新日期:2014-12-21 00:00:00

  • Estimation of tissue resistivities from multiple-electrode impedance measurements.

    abstract::In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/001

    authors: Eyüboğlu BM,Pilkington TC,Wolf PD

    更新日期:1994-01-01 00:00:00

  • The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

    abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/003

    authors: Trapp JV,Partridge M,Hansen VN,Childs P,Bedford J,Warrington AP,Leach MO,Webb S

    更新日期:2004-05-07 00:00:00

  • Elastic modulus imaging: some exact solutions of the compressible elastography inverse problem.

    abstract::We consider several inverse problems motivated by elastography. Given the (possibly transient) displacement field measured everywhere in an isotropic, compressible, linear elastic solid, and given density rho, determine the Lamé parameters lambda and mu. We consider several special cases of this problem: (a) for mu kn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/6/003

    authors: Barbone PE,Oberai AA

    更新日期:2007-03-21 00:00:00

  • Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction.

    abstract::Accurate scatter compensation in SPECT can be performed by modelling the scatter response function during the reconstruction process. This method is called reconstruction-based scatter compensation (RBSC). It has been shown that RBSC has a number of advantages over other methods of compensating for scatter, but using ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/014

    authors: Kadrmas DJ,Frey EC,Karimi SS,Tsui BM

    更新日期:1998-04-01 00:00:00

  • A note on computing the derivative at a constant direction.

    abstract::The derivative at constant direction is frequently used in inversion of cone-beam data. Several algorithms for computing the derivative have been proposed in the literature. The best algorithm to date has been proposed recently by Noo et al (2007 Phys. Med. Biol. 52 5393-414). In this note we propose a new, simple and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/N01

    authors: Katsevich A

    更新日期:2011-02-21 00:00:00

  • An investigation of factors affecting the accuracy of in vivo measurements of skin pigments by reflectance spectrophotometry.

    abstract::Factors affecting the accuracy of the in vivo measurement of cutaneous pigments and blood oxygenation by reflectance spectrophotometry have been examined. It was found that stray light, the amounts of haemoglobin and melanin, and the level of blood oxygenation all contributed to the measured reflectance and had to be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/9/009

    authors: Hajizadeh-Saffar M,Feather JW,Dawson JB

    更新日期:1990-09-01 00:00:00

  • Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

    abstract::The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9501

    authors: Giménez-Alventosa V,Giménez V,Ballester F,Vijande J,Andreo P

    更新日期:2020-10-07 00:00:00

  • Automated sonographic evaluation of testicular perfusion.

    abstract::Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly deter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/14/010

    authors: Thierman JS,Clement GT,Kalish LA,O'Kane PL,Frauscher F,Paltiel HJ

    更新日期:2006-07-21 00:00:00

  • Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology.

    abstract::Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R02

    authors: Doi K

    更新日期:2006-07-07 00:00:00

  • An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking.

    abstract::Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/005

    authors: Noel CE,Santanam L,Olsen JR,Baker KW,Parikh PJ

    更新日期:2010-01-07 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • Dosimetric characteristics of electron beams produced by a mobile accelerator for IORT.

    abstract::Energy and angular distributions of electron beams with different energies were simulated by Monte Carlo calculations. These beams were generated by the NOVAC7 system (Hitesys, Italy), a mobile electron accelerator specifically dedicated to intra-operative radiation therapy (IORT). The electron beam simulations were v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/008

    authors: Pimpinella M,Mihailescu D,Guerra AS,Laitano RF

    更新日期:2007-10-21 00:00:00

  • Dosimetry of 106Ru eye applicators with a p-type silicon detector.

    abstract::Beta emitting 106Ru-applicators are used to treat choroidal melanoma. In order to improve the accuracy and simplify the dosimetry of these applicators, the suitability of using a p-type silicon semiconductor detector has been investigated. The detector is calibrated in a low energy electron beam. An important property...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/7/005

    authors: Lax I

    更新日期:1991-07-01 00:00:00

  • Computational fluid dynamics modelling of perfusion measurements in dynamic contrast-enhanced computed tomography: development, validation and clinical applications.

    abstract::Dynamic contrast-enhanced computed tomography (DCE-CT) is an imaging tool that aids in evaluating functional characteristics of tissue at different stages of disease management: diagnostic, radiation treatment planning, treatment effectiveness, and monitoring. Clinical validation of DCE-derived perfusion parameters re...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/6111

    authors: Peladeau-Pigeon M,Coolens C

    更新日期:2013-09-07 00:00:00

  • Changes in optical properties of ex vivo rat prostate due to heating.

    abstract::This study examines the effectiveness of a single, first-order Arrhenius process in accurately modelling the thermally induced changes in the optical properties, particularly the reduced scattering coefficient, mu(s)', and the absorption coefficient, mu(a), of ex vivo rat prostate. Recent work has shown that mu(s)' ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/319

    authors: Skinner MG,Everts S,Reid AD,Vitkin IA,Lilge L,Sherar MD

    更新日期:2000-05-01 00:00:00

  • High-resolution numerical model of the middle and inner ear for a detailed analysis of radio frequency absorption.

    abstract::In order to enable a detailed analysis of radio frequency (RF) absorption in the human middle and inner ear organs, a numerical model of these organs was developed at a spatial resolution of 0.1 mm, based on a real human tissue sample. The dielectric properties of the liquids (perilymph and endolymph) inside the bony ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/001

    authors: Schmid G,Uberbacher R,Samaras T,Jappel A,Baumgartner WD,Tschabitscher M,Mazal PR

    更新日期:2007-04-07 00:00:00

  • Mucosal deformation from an impinging transonic gas jet and the ballistic impact of microparticles.

    abstract::By means of a transonic gas jet, gene guns ballistically deliver microparticle formulations of drugs and vaccines to the outer layers of the skin or mucosal tissue to induce unique physiological responses for the treatment of a range of conditions. Reported high-speed imaging experiments show that the mucosa deforms s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/010

    authors: Hardy MP,Kendall MA

    更新日期:2005-10-07 00:00:00

  • Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications.

    abstract::Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, makin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1c37

    authors: Du J,Bai X,Cherry SR

    更新日期:2019-08-07 00:00:00

  • Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T.

    abstract::Carotid atherosclerosis measurements for eight subjects at baseline and 14 +/- 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/011

    authors: Vidal A,Bureau Y,Wade T,Spence JD,Rutt BK,Fenster A,Parraga G

    更新日期:2008-12-07 00:00:00

  • Report of the IPSM working party on low- and medium-energy x-ray dosimetry. Institute of Physical Sciences in Medicine.

    abstract::New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the IAEA in 1987. These are not considered to possess sufficient support from other s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/8/001

    authors:

    更新日期:1991-08-01 00:00:00

  • Tumour xenograft detection through quantitative analysis of the metabolic profile of urine in mice.

    abstract::The metabolic content of urine from NIH III nude mice (n = 22) was analysed before and after inoculation with human glioblastoma multiforme (GBM) cancer cells. An age- and gender-matched control population (n = 14) was also studied to identify non-tumour-related changes. Urine samples were collected daily for 6 weeks,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/002

    authors: Moroz J,Turner J,Slupsky C,Fallone G,Syme A

    更新日期:2011-02-07 00:00:00

  • Laser speckle imaging of blood flow in microcirculation.

    abstract::Monitoring the spatio-temporal characteristics of microcirculation is crucial for studying the functional activities of biotissue and the mechanism of disease. However, conventional methods used to measure blood flow suffer from limited spatial resolution or the injection of exogenous substances or the need of scannin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/7/020

    authors: Cheng H,Luo Q,Liu Q,Lu Q,Gong H,Zeng S

    更新日期:2004-04-07 00:00:00

  • Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT.

    abstract::This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical obs...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/7/2751

    authors: Lee TS,Frey EC,Tsui BM

    更新日期:2015-04-07 00:00:00

  • A high-sensitivity small animal SPECT system.

    abstract::Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) sy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/013

    authors: Mitchell GS,Cherry SR

    更新日期:2009-03-07 00:00:00

  • Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT.

    abstract::A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4476

    authors: Salas-Ramirez M,Tran-Gia J,Gbureck U,Kosmala A,Lassmann M

    更新日期:2019-10-16 00:00:00

  • Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation.

    abstract::The (83)Kr magnetic resonance (MR) relaxation time T(1) of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary (83)Kr T(1) relaxation measurements in excise...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/001

    authors: Stupic KF,Elkins ND,Pavlovskaya GE,Repine JE,Meersmann T

    更新日期:2011-07-07 00:00:00

  • Monte Carlo-based evaluation of S-values in mouse models for positron-emitting radionuclides.

    abstract::In addition to being a powerful clinical tool, Positron emission tomography (PET) is also used in small laboratory animal research to visualize and track certain molecular processes associated with diseases such as cancer, heart disease and neurological disorders in living small animal models of disease. However, dosi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/1/169

    authors: Xie T,Zaidi H

    更新日期:2013-01-07 00:00:00

  • Implementation of biologically conformal radiation therapy (BCRT) in an algorithmic segmentation-based inverse planning approach.

    abstract::The development of new biological imaging technologies offers the opportunity to further individualize radiotherapy. Biologically conformal radiation therapy (BCRT) implies the use of the spatial distribution of one or more radiobiological parameters to guide the IMRT dose prescription. Our aim was to implement BCRT i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/N02

    authors: Vanderstraeten B,De Gersem W,Duthoy W,De Neve W,Thierens H

    更新日期:2006-08-21 00:00:00