Proton beam monitor chamber calibration.

Abstract:

:The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences-of the order of 3%-were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth-i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers-rather than cylindrical chambers-for the reference dosimetry of pseudo-monoenergetic proton beams.

journal_name

Phys Med Biol

authors

Gomà C,Lorentini S,Meer D,Safai S

doi

10.1088/0031-9155/59/17/4961

subject

Has Abstract

pub_date

2014-09-07 00:00:00

pages

4961-71

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Optimization and performance study of a proton CT system for pre-clinical small animal imaging.

    abstract::Proton computed tomography (pCT) promises to reduce or even eliminate range uncertainties inherent in the conversion of Hounsfield units into relative stopping power (RSP) for proton therapy treatment planning. This is of particular interest for proton irradiation studies in animal models due to the high precision req...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8afc

    authors: Meyer S,Bortfeldt J,Lämmer P,Englbrecht FS,Pinto M,Schnürle K,Würl M,Parodi K

    更新日期:2020-08-13 00:00:00

  • Layer-specific ultrasound elastography using a multi-layered shear wave dispersion model for assessing the viscoelastic properties.

    abstract::Mechanical properties of biological tissues are significant biomarkers for diagnosing various diseases. Assessing the viscoelastic properties of multi-layer tissues has remained challenging for a long time. Some shear wave models have been proposed to estimate thin-layer tissues' viscoelasticity recently. However, the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abca04

    authors: Lu G,Li R,Qian X,Chen R,Jiang L,Chen Z,Shung KK,Humayun MS,Zhou Q

    更新日期:2020-11-12 00:00:00

  • Spinal pedicle screw planning using deformable atlas registration.

    abstract::Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device sele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5f42

    authors: Goerres J,Uneri A,De Silva T,Ketcha M,Reaungamornrat S,Jacobson M,Vogt S,Kleinszig G,Osgood G,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-07 00:00:00

  • Dosimetric characteristics of electron beams produced by a mobile accelerator for IORT.

    abstract::Energy and angular distributions of electron beams with different energies were simulated by Monte Carlo calculations. These beams were generated by the NOVAC7 system (Hitesys, Italy), a mobile electron accelerator specifically dedicated to intra-operative radiation therapy (IORT). The electron beam simulations were v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/008

    authors: Pimpinella M,Mihailescu D,Guerra AS,Laitano RF

    更新日期:2007-10-21 00:00:00

  • A method for converting dose-to-medium to dose-to-tissue in Monte Carlo studies of gold nanoparticle-enhanced radiotherapy.

    abstract::Gold nanoparticles (GNPs) have shown potential in recent years as a means of therapeutic dose enhancement in radiation therapy. However, a major challenge in moving towards clinical implementation is the exact characterisation of the dose enhancement they provide. Monte Carlo studies attempt to explore this property, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/5/2014

    authors: Koger B,Kirkby C

    更新日期:2016-03-07 00:00:00

  • Physics considerations in MV-CBCT multi-layer imager design.

    abstract::Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac8c6

    authors: Hu YH,Fueglistaller R,Myronakis M,Rottmann J,Wang A,Shedlock D,Morf D,Baturin P,Huber P,Star-Lack J,Berbeco R

    更新日期:2018-06-20 00:00:00

  • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal.

    abstract::Four-dimensional (4D) methods strive to achieve highly conformal radiotherapy, particularly for lung and breast tumours, in the presence of respiratory-induced motion of tumours and normal tissues. Four-dimensional radiotherapy accounts for respiratory motion during imaging, planning and radiation delivery, and requir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/1/304

    authors: Vedam SS,Keall PJ,Kini VR,Mostafavi H,Shukla HP,Mohan R

    更新日期:2003-01-07 00:00:00

  • Full-field speckle interferometry for non-contact photoacoustic tomography.

    abstract::A full-field speckle interferometry method for non-contact and prospectively high speed Photoacoustic Tomography is introduced and evaluated as proof of concept. Thermoelastic pressure induced changes of the objects topography are acquired in a repetitive mode without any physical contact to the object. In order to ob...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4045

    authors: Horstmann J,Spahr H,Buj C,Münter M,Brinkmann R

    更新日期:2015-05-21 00:00:00

  • Gating characteristics of an Elekta radiotherapy treatment unit measured with three types of detector.

    abstract::The characteristics of an Elekta Precise treatment machine with a gating interface were investigated. Three detectors were used: a Farmer ionization chamber, a MatriXX ionization chamber array and an in-house, single pulse-measurement ionization chamber (IVC). Measurements were made of dosimetric accuracy, flatness an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/N02

    authors: Evans PM,Symonds-Tayler JR,Colgan R,Hugo GD,Letts N,Sandin C

    更新日期:2010-04-21 00:00:00

  • A preclinical simulated dataset of S-values and investigation of the impact of rescaled organ masses using the MOBY phantom.

    abstract::Nuclear medicine and radiation therapy, although well established, are still rapidly evolving, by exploiting animal models, aiming to define precise dosimetry in molecular imaging protocols. The purpose of the present study was to create a dataset based on the MOBY phantom for the calculation of organ-to-organ S-value...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2333

    authors: Kostou T,Papadimitroulas P,Loudos G,Kagadis GC

    更新日期:2016-03-21 00:00:00

  • Temporal backward projection of optoacoustic pressure transients using fourier transform methods.

    abstract::In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/309

    authors: Köstli KP,Frenz M,Bebie H,Weber HP

    更新日期:2001-07-01 00:00:00

  • Semi-empirical formulation of multiple scattering for the Gaussian beam model of heavy charged particles stopping in tissue-like matter.

    abstract::Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particle...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/N01

    authors: Kanematsu N

    更新日期:2009-03-07 00:00:00

  • An integrated platform for image-guided cardiac resynchronization therapy.

    abstract::Cardiac resynchronization therapy (CRT) is an effective procedure for patients with heart failure but 30% of patients do not respond. This may be due to sub-optimal placement of the left ventricular (LV) lead. It is hypothesized that the use of cardiac anatomy, myocardial scar distribution and dyssynchrony information...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/10/2953

    authors: Ma YL,Shetty AK,Duckett S,Etyngier P,Gijsbers G,Bullens R,Schaeffter T,Razavi R,Rinaldi CA,Rhode KS

    更新日期:2012-05-21 00:00:00

  • Contactless remote induction of shear waves in soft tissues using a transcranial magnetic stimulation device.

    abstract::This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel pha...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2582

    authors: Grasland-Mongrain P,Miller-Jolicoeur E,Tang A,Catheline S,Cloutier G

    更新日期:2016-03-21 00:00:00

  • A mathematical model for predicting the changes of non-small cell lung cancer based on tumor mass during radiotherapy.

    abstract::This study aims to build a feasible mathematical model to analyze the mass evolution of NSCLC during standard fractionated radiotherapy. Seventy-three cases of NSCLC who were received radiotherapy with prescription dose of 2 Gy  ×  30 fx were selected retrospectively and divided into adenocarcinoma (ADC) group and squ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab47c0

    authors: Chen J,Wang K,Jian J,Zhang W

    更新日期:2019-11-26 00:00:00

  • A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

    abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e37

    authors: Chi Y,Rezaeian NH,Shen C,Zhou Y,Lu W,Yang M,Hannan R,Jia X

    更新日期:2017-07-07 00:00:00

  • Robust radiation therapy optimization using simulated treatment courses for handling deformable organ motion.

    abstract::We describe a radiation therapy treatment plan optimization method that explicitly considers the effects of interfraction organ motion through optimization on the clinical target volume (CTV), and investigate how it compares to conventional planning using a planning target volume (PTV). The method uses simulated treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd591

    authors: Fredriksson A,Engwall E,Andersson B

    更新日期:2020-12-21 00:00:00

  • Dose uncertainty in radiotherapy of patients with head and neck cancer measured by in vivo ESR/alanine dosimetry using a mouthpiece.

    abstract::In order (i) to evaluate the dose uncertainty of the mouthpiece in daily use during intensity-modulated radiotherapy of patients with head and neck cancer, and (ii) to present a system for in vivo dosimetry of the oral mucosa, we equipped the mouthpiece with alanine dosimeter probes for in vivo dosimetry. The aim was ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/5/010

    authors: Wagner D,Anton M,Vorwerk H

    更新日期:2011-03-07 00:00:00

  • Design, construction and use of a large-sample field-cycled PEDRI imager.

    abstract::The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/7/008

    authors: Lurie DJ,Foster MA,Yeung D,Hutchison JM

    更新日期:1998-07-01 00:00:00

  • Learning image based surrogate relevance criterion for atlas selection in segmentation.

    abstract::Picking geometrically relevant atlases from the whole training set is crucial to multi-atlas based image segmentation, especially with extensive data of heterogeneous quality in the Big Data era. Unfortunately, there is very limited understanding of how currently used image similarity criteria reveal geometric relevan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4223

    authors: Zhao T,Ruan D

    更新日期:2016-06-07 00:00:00

  • Volume estimation of low-contrast lesions with CT: a comparison of performances from a phantom study, simulations and theoretical analysis.

    abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/671

    authors: Li Q,Gavrielides MA,Zeng R,Myers KJ,Sahiner B,Petrick N

    更新日期:2015-01-21 00:00:00

  • A Monte Carlo investigation of contaminant electrons due to a novel in vivo transmission detector.

    abstract::A novel transmission detector (IBA Dosimetry, Germany) developed as an IMRT quality assurance tool, intended for in vivo patient dose measurements, is studied here. The goal of this investigation is to use Monte Carlo techniques to characterize treatment beam parameters in the presence of the detector and to compare t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/020

    authors: Asuni G,Jensen JM,McCurdy BM

    更新日期:2011-02-21 00:00:00

  • Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator.

    abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1375

    authors: Bol GH,Hissoiny S,Lagendijk JJ,Raaymakers BW

    更新日期:2012-03-07 00:00:00

  • In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm.

    abstract::The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/017

    authors: Beek JF,Blokland P,Posthumus P,Aalders M,Pickering JW,Sterenborg HJ,van Gemert MJ

    更新日期:1997-11-01 00:00:00

  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00

  • NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapy.

    abstract::This work aims to evaluate the predictive strength of the relative seriality, parallel and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models regarding the incidence of radiation pneumonitis (RP), in a group of patients following lung cancer radiotherapy and also to examine their correlati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/013

    authors: Tsougos I,Nilsson P,Theodorou K,Kjellén E,Ewers SB,Jarlman O,Lind BK,Kappas C,Mavroidis P

    更新日期:2007-02-21 00:00:00

  • Integration of dynamic contrast-enhanced magnetic resonance imaging and T2-weighted imaging radiomic features by a canonical correlation analysis-based feature fusion method to predict histological grade in ductal breast carcinoma.

    abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fd3

    authors: Fan M,Liu Z,Xie S,Xu M,Wang S,Gao X,Li L

    更新日期:2019-10-23 00:00:00

  • A variable fluence step clustering and segmentation algorithm for step and shoot IMRT.

    abstract::A step and shoot sequencer was developed that can be integrated into an IMRT optimization algorithm. The method uses non-uniform fluence steps and is adopted to the constraints of an MLC. It consists of a clustering, a smoothing and a segmentation routine. The performance of the algorithm is demonstrated for eight mat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/319

    authors: Bär W,Alber M,Nüsslin F

    更新日期:2001-07-01 00:00:00

  • A task-based quality control metric for digital mammography.

    abstract::A reader study was conducted to tune the parameters of an observer model used to predict the detectability index (dʹ ) of test objects as a task-based quality control (QC) metric for digital mammography. A simple test phantom was imaged to measure the model parameters, namely, noise power spectrum,modulation transfer ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6621

    authors: Bloomquist AK,Mainprize JG,Mawdsley GE,Yaffe MJ

    更新日期:2014-11-07 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00