Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements.

Abstract:

:An open-ended coaxial probe is often used for investigating the dielectric properties of biological tissues. The present study indicates that in addition to the probe size, the penetration of the electromagnetic (EM) fields of an open-ended coaxial probe in contact with the skin is dependent on the applied frequency between 1 MHz and 1 GHz. At high frequencies, above 100 MHz, the measured dielectric parameters are functions of the dielectric properties of different cutaneous layers and subcutaneous fat. At lower frequencies, less than 10 MHz, the measurement is mainly dependent on the dielectric properties of superficial structures of the skin. The reason for this is that the probe, the surface of the skin, mainly stratum corneum, and underlying skin form a capacitance where the stratum corneum with low water content lies between the well-conducting dermis and the probe. The situation is equivalent to the frequency-dependent Maxwell-Wagner interfacial polarization. This result is verified by experimental dielectric measurements and with human skin in vivo.

journal_name

Phys Med Biol

authors

Alanen E,Lahtinen T,Nuutinen J

doi

10.1088/0031-9155/44/7/404

subject

Has Abstract

pub_date

1999-07-01 00:00:00

pages

N169-76

issue

7

eissn

0031-9155

issn

1361-6560

journal_volume

44

pub_type

杂志文章
  • Accuracy of quantitative reconstructions in SPECT/CT imaging.

    abstract::The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/009

    authors: Shcherbinin S,Celler A,Belhocine T,Vanderwerf R,Driedger A

    更新日期:2008-09-07 00:00:00

  • A convolution-subtraction scatter correction method for 3D PET.

    abstract::3D acquisition and reconstruction in positron emission tomography (PET) produce data with improved signal-to-noise ratios compared with conventional 2D slice-oriented methods. However, the sensitivity increase is accompanied by an increase in the number of scattered photons and random coincidences detected. This paper...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/3/009

    authors: Bailey DL,Meikle SR

    更新日期:1994-03-01 00:00:00

  • Assessment of the exposure to biologically effective UV radiation using a dosimetric technique to evaluate the solar spectrum.

    abstract::A cost-effective method employing polysulphone, nalidixic acid, 8-methoxypsoralen and phenothiazine as UV dosimeters is presented for evaluating the UV spectrum. The exposure measured by each dosimeter is a function of the source spectrum and the spectral response of the material. Each material has a different spectra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/005

    authors: Parisi AV,Wong JC,Moore GI

    更新日期:1997-01-01 00:00:00

  • Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

    abstract::Electrical properties (EP), namely conductivity and permittivity, can provide endogenous contrast for tissue characterization. Using electrical property tomography (EPT), maps of EP can be generated from conventional MRI data. This report investigates the feasibility and accuracy of EPT at 21.1 T for multiple RF coils...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3259

    authors: Amouzandeh G,Mentink-Vigier F,Helsper S,Bagdasarian FA,Rosenberg JT,Grant SC

    更新日期:2020-02-28 00:00:00

  • Distance-driven projection and backprojection in three dimensions.

    abstract::Projection and backprojection are operations that arise frequently in tomographic imaging. Recently, we proposed a new method for projection and backprojection, which we call distance-driven, and that offers low arithmetic cost and a highly sequential memory access pattern. Furthermore, distance-driven projection and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/024

    authors: De Man B,Basu S

    更新日期:2004-06-07 00:00:00

  • Monte Carlo calculation of VMAT and helical tomotherapy dose distributions for lung stereotactic treatments with intra-fraction motion.

    abstract::The aim of this study is to calculate realistic dose distributions that include the continuous deformation of organs and continuous motion of machine using 4D Monte Carlo methods for both volumetric modulated arc therapy and helical tomotherapy treatments. As part of a previous study, we presented a method to perform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2807

    authors: Belec J,Clark BG

    更新日期:2013-05-07 00:00:00

  • Automated 3D ultrasound image analysis for first trimester assessment of fetal health.

    abstract::The first trimester fetal ultrasound scan is important to confirm fetal viability, to estimate the gestational age of the fetus, and to detect fetal anomalies early in pregnancy. First trimester ultrasound images have a different appearance than for the second trimester scan, reflecting the different stage of fetal de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3ad1

    authors: Ryou H,Yaqub M,Cavallaro A,Papageorghiou AT,Alison Noble J

    更新日期:2019-09-17 00:00:00

  • Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics.

    abstract::The most advanced delivery technique for proton radiotherapy is active spot scanning. So far, predominantly static targets have been treated with active spot scanning, since mobile targets in combination with dynamic treatment delivery can lead to interplay effects, causing inhomogeneous dose distributions. One way to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/016

    authors: Knopf AC,Hong TS,Lomax A

    更新日期:2011-11-21 00:00:00

  • Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

    abstract::The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5 cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaba8f

    authors: Hackett SL,van Asselen B,Wolthaus JWH,Bluemink JJ,Ishakoglu K,Kok J,Lagendijk JJW,Raaymakers BW

    更新日期:2018-05-01 00:00:00

  • Radiation dose factors for alpha-emitters in osteons and some considerations on dose non-uniformity ratios and relative distribution factors.

    abstract::Dose factors for locations within a tissue-filled cylindrical cavity bounded by an infinite medium of bone labelled with an alpha-emitter are calculated by means of a Monte Carlo procedure. The calculational approach is general and allows us to determine dose factors for specific distances or target volumes defined by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/3/007

    authors: Polig E

    更新日期:1989-03-01 00:00:00

  • An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    abstract::The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2307

    authors: Moore CS,Wood TJ,Avery G,Balcam S,Needler L,Beavis AW,Saunderson JR

    更新日期:2014-05-07 00:00:00

  • Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model.

    abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4364

    authors: Šarolić A,Živković Z,Reilly JP

    更新日期:2016-06-21 00:00:00

  • Late rectal bleeding after 3D-CRT for prostate cancer: development of a neural-network-based predictive model.

    abstract::The aim of this study was to develop a model exploiting artificial neural networks (ANNs) to correlate dosimetric and clinical variables with late rectal bleeding in prostate cancer patients undergoing radical radiotherapy and to compare the ANN results with those of a standard logistic regression (LR) analysis. 718 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1399

    authors: Tomatis S,Rancati T,Fiorino C,Vavassori V,Fellin G,Cagna E,Mauro FA,Girelli G,Monti A,Baccolini M,Naldi G,Bianchi C,Menegotti L,Pasquino M,Stasi M,Valdagni R

    更新日期:2012-03-07 00:00:00

  • Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.

    abstract::We investigated the physical characteristics of two complementary metal oxide semiconductor (CMOS) mammography detectors. The detectors featured 14-bit image acquisition, 50 microm detector element (del) size and an active area of 5 cm x 5 cm. One detector was a passive-pixel sensor (PPS) with signal amplification per...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/022

    authors: Elbakri IA,McIntosh BJ,Rickey DW

    更新日期:2009-03-21 00:00:00

  • Reduction of scatter in breast CT yields improved microcalcification visibility.

    abstract::The inadequate visibility of microcalcifications-small calcium deposits that cue radiologists to early stages of cancer-is a major limitation in current designs of dedicated breast computed tomography (bCT). This limitation has previously been attributed to the constituent components, spatial resolution, and utilized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae07

    authors: Ghazi P

    更新日期:2020-12-04 00:00:00

  • Optimal material discrimination using spectral x-ray imaging.

    abstract::Spectral x-ray imaging using novel photon counting x-ray detectors (PCDs) with energy resolving abilities is capable of providing energy-selective images. PCDs have energy thresholds, enabling the classification of photons into multiple energy bins. The extra energy information provided may allow materials such as iod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/18/012

    authors: Nik SJ,Meyer J,Watts R

    更新日期:2011-09-21 00:00:00

  • Automated stroke lesion segmentation in non-contrast CT scans using dense multi-path contextual generative adversarial network.

    abstract::Stroke lesion volume is a key radiologic measurement in assessing prognosis of acute ischemic stroke (AIS) patients. The aim of this paper is to develop an automated segmentation method for accurately segmenting follow-up ischemic and hemorrhagic lesion from multislice non-contrast CT (NCCT) volumes of AIS patients. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba166

    authors: Kuang H,Menon BK,Qiu W

    更新日期:2020-11-05 00:00:00

  • Sensitivity study of the microdosimetric kinetic model parameters for carbon ion radiotherapy.

    abstract::In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the loc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae8b4

    authors: Dahle TJ,Magro G,Ytre-Hauge KS,Stokkevåg CH,Choi K,Mairani A

    更新日期:2018-11-12 00:00:00

  • Volume estimation of low-contrast lesions with CT: a comparison of performances from a phantom study, simulations and theoretical analysis.

    abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/671

    authors: Li Q,Gavrielides MA,Zeng R,Myers KJ,Sahiner B,Petrick N

    更新日期:2015-01-21 00:00:00

  • An adaptive technique for digital noise suppression in on-line portal imaging.

    abstract::Two complementary approaches to the noise suppression problem in on-line portal imaging have been analysed. Temporal filtering by image summation can substantially reduce the amount of noise in an image. In many cases, however, movements of the patient or the radiation source limit the time period over which the avera...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/3/011

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1990-03-01 00:00:00

  • Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models.

    abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/004

    authors: Kühn S,Jennings W,Christ A,Kuster N

    更新日期:2009-02-21 00:00:00

  • The investigation of different cameras for in-beam PET imaging.

    abstract::In situ and in vivo treatment plan verification and beam monitoring as well as dose control during heavy-ion tumour therapy can be performed in principle by measurements of range distributions of beta(+)-emitting nuclei by means of PET techniques. For this purpose the performance of different types of positron camera ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/2/006

    authors: Pawelke J,Byars L,Enghardt W,Fromm WD,Geissel H,Hasch BG,Lauckner K,Manfrass P,Schardt D,Sobiella M

    更新日期:1996-02-01 00:00:00

  • Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    abstract::In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, notice...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/19/003

    authors: Karampatzakis A,Samaras T

    更新日期:2010-10-07 00:00:00

  • High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals.

    abstract::We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab8d2

    authors: Preissner M,Murrie RP,Pinar I,Werdiger F,Carnibella RP,Zosky GR,Fouras A,Dubsky S

    更新日期:2018-04-20 00:00:00

  • Computational errors of the induced electric field in voxelized and tetrahedral anatomical head models exposed to spatially uniform and localized magnetic fields.

    abstract::At low and intermediate frequencies, the strength of the induced electric field is used as dosimetric quantity for human protection in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. To compute the induced electric field, numerical methods based on anatomically realistic voxel mo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5dfb

    authors: Soldati M,Laakso I

    更新日期:2020-01-10 00:00:00

  • Evaluation of deformable image registration and a motion model in CT images with limited features.

    abstract::Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2539

    authors: Liu F,Hu Y,Zhang Q,Kincaid R,Goodman KA,Mageras GS

    更新日期:2012-05-07 00:00:00

  • A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.

    abstract::A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/18/011

    authors: Pan X,Xia D,Zou Y,Yu L

    更新日期:2004-09-21 00:00:00

  • A multiplicative correction factor for tissue heterogeneities.

    abstract::A new multiplicative correction factor for tissue heterogeneities based on an exact expression for homogeneous non-unit-density media is proposed. O'Connor's density scaling theorem is invoked to evaluate the medium-specific tissue-maximum ratios used in the exact formulation. Monte Carlo calculations were performed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/10/005

    authors: Petti PL,Siddon RL,Bjärngard BE

    更新日期:1986-10-01 00:00:00

  • A low cost method for hard x-ray grating interferometry.

    abstract::Grating interferometry is advantageous over conventional x-ray absorption imaging because it enables the detection of samples constituted by low atomic number elements (low-Z materials). Therefore, it has a potential application in biological science and medical diagnostics. The grating interferometry has some critica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/23/8266

    authors: Du Y,Lei Y,Liu X,Huang J,Zhao Z,Guo J,Li J,Niu H

    更新日期:2016-12-07 00:00:00

  • Modified sector-integration method for predicting the output factors of electron beams including extended source to surface distance.

    abstract::A modified sector-integration method is presented that can predict the output factors of irregular shaped electron fields even in the case of extended source to surface distance (SSD). The model takes as input measured output factors for circular inserts of various radii. These circular fields were measured at SSDs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/318

    authors: Choi DR,Wolters J,Mason D,Baillie A

    更新日期:2000-11-01 00:00:00