Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

Abstract:

:The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5 cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit dose on surfaces outside the primary beam perpendicular to the magnetic field. These spiraling contaminant electrons (SCE) could increase skin doses to protruding regions of the patient along the cranio-caudal axis. This study investigated doses from SCE for an MRI-linac comprising a 7 MV linac and a 1.5 T MRI scanner. Surface doses to films perpendicular to the magnetic field and 5 cm from the radiation beam edge showed increased dose within the projection of the primary beam, whereas films parallel to the magnetic field and 5 cm from the beam edge showed no region of increased dose. However, the dose from contaminant electrons is absorbed within a few millimeters. For large fields, the SCE dose is within the same order of magnitude as doses from scattered and leakage photons. Doses for both SCE and scattered photons decrease rapidly with decreasing beam size and increasing distance from the beam edge.

journal_name

Phys Med Biol

authors

Hackett SL,van Asselen B,Wolthaus JWH,Bluemink JJ,Ishakoglu K,Kok J,Lagendijk JJW,Raaymakers BW

doi

10.1088/1361-6560/aaba8f

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

095001

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

杂志文章
  • Monte Carlo modelling of electron beams from medical accelerators.

    abstract::Monte Carlo simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development of computer technology, Monte Carlo based treatment planning for radiation therapy is becoming practical. A basic requirement for Monte Carlo treatment pl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/12/201

    authors: Ma CM,Jiang SB

    更新日期:1999-12-01 00:00:00

  • Comparison of two respiration monitoring systems for 4D imaging with a Siemens CT using a new dynamic breathing phantom.

    abstract::Four-dimensional computed tomography (4D-CT) requires breathing information from the patient, and for this, several systems are available. Testing of these systems, under realistic conditions, requires a phantom with a moving target and an expandable outer contour. An anthropomorphic phantom was developed to simulate ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/N131

    authors: Vásquez AC,Runz A,Echner G,Sroka-Perez G,Karger CP

    更新日期:2012-05-07 00:00:00

  • Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method.

    abstract::Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories throu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/013

    authors: Bodammer NC,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2009-02-21 00:00:00

  • Towards a gold standard for quantitative coronary arteriography.

    abstract::Densitometric quantification of coronary artery stenoses in angiographic images can be problematic for two reasons: (i) the x-rays are inadequately oriented with respect to the vessel segments of interest at image acquisition; (ii) non-linear effects due for instance to beam hardening, scattered radiation and veiling ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/011

    authors: Doriot PA,Dorsaz PA,Dorsaz L,Bodenmann JJ

    更新日期:1997-12-01 00:00:00

  • Radiofrequency heating effects around resonant lengths of wire in MRI.

    abstract::Several recent reports agree that the potentially dangerous heating around extended wires or coaxial cables inside the bodycoil of a magnetic resonance imager is related to resonant effects. No quantitative description of this idea has been given so far. We analyse a simplified situation, where a straight metallic wir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/16/312

    authors: Pictet J,Meuli R,Wicky S,van der Klink JJ

    更新日期:2002-08-21 00:00:00

  • Soft-tissue phase-contrast tomography with an x-ray tube source.

    abstract::We report the first experimental soft-tissue phase-contrast tomography results using a conventional x-ray tube source, with a millimeter-sized focal spot. The setup is based on a Talbot-Lau grating interferometer operated at a mean energy of 28 keV. We present three-dimensional ex vivo images of a chicken heart sample...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/010

    authors: Bech M,Jensen TH,Feidenhans'l R,Bunk O,David C,Pfeiffer F

    更新日期:2009-05-07 00:00:00

  • A radiographic technique for measuring the powder packing density in the cavities of trabecular bone.

    abstract::An X-ray technique has been developed to enable reproducible and quantitative data to be obtained from radiographs taken by a diagnostic X-ray machine. Careful attention has been paid to the alignment of the specimen and the diagnostic tube and to operating conditions. The choice of X-ray spectrum is described togethe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/4/003

    authors: King SD

    更新日期:1977-07-01 00:00:00

  • The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

    abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/4/001

    authors: Chauvet I,Petitfils A,Lehobey C,Kristner JY,Brunet Y,Lembrez R,Gaboriaud G,Mazal A,Zefkili S,Rosenwald JC

    更新日期:2005-02-21 00:00:00

  • Fast dose calculation in magnetic fields with GPUMCD.

    abstract::A new hybrid imaging-treatment modality, the MRI-Linac, involves the irradiation of the patient in the presence of a strong magnetic field. This field acts on the charged particles, responsible for depositing dose, through the Lorentz force. These conditions require a dose calculation engine capable of taking into con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/003

    authors: Hissoiny S,Raaijmakers AJ,Ozell B,Després P,Raaymakers BW

    更新日期:2011-08-21 00:00:00

  • Dose uncertainty in radiotherapy of patients with head and neck cancer measured by in vivo ESR/alanine dosimetry using a mouthpiece.

    abstract::In order (i) to evaluate the dose uncertainty of the mouthpiece in daily use during intensity-modulated radiotherapy of patients with head and neck cancer, and (ii) to present a system for in vivo dosimetry of the oral mucosa, we equipped the mouthpiece with alanine dosimeter probes for in vivo dosimetry. The aim was ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/5/010

    authors: Wagner D,Anton M,Vorwerk H

    更新日期:2011-03-07 00:00:00

  • K x-ray fluorescence measurements of bone lead concentration: the analysis of low-level data.

    abstract::K line x-ray fluorescence (KXRF) measurements of bone lead have emerged as a promising new biological marker of internal lead dose in epidemiological studies. Some disagreements exist, however, over the analysis of data at low levels of bone lead concentration. In this study, we performed 30 serial measurements on eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/9/007

    authors: Kim R,Aro A,Rotnitzky A,Amarasiriwardena C,Hu H

    更新日期:1995-09-01 00:00:00

  • Modelling individual temperature profiles from an isolated perfused bovine tongue.

    abstract::To predict the temperature distribution during hyperthermia treatments a thermal model that accounts for the thermal effect of blood flow is mandatory. The DIscrete VAsculature (DIVA) thermal model developed at our department is able to do so; geometrically described vessels are handled individually and the remaining ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/314

    authors: Raaymakers BW,Crezee J,Lagendijk JJ

    更新日期:2000-03-01 00:00:00

  • SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theory.

    abstract::A method of measuring the image quality of medical imaging equipment is considered within the framework of statistical decision theory. In this approach, images are regarded as random vectors and image quality is defined in the context of the image information available for performing a specified detection or discrimi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/1/006

    authors: Tapiovaara MJ,Wagner RF

    更新日期:1993-01-01 00:00:00

  • Modelling the temporal region in patients with temporal lobe epilepsy.

    abstract::EEG interictal epileptiform discharges in temporal lobe epilepsy are associated with magnetic fields. The maxima of magnetic spikes recorded over the spherical portions of the head appear fairly symmetric, whereas those over the lower temporal region often have irregular shapes. Furthermore, their magnitude is often u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/009

    authors: Rose DF,Sato S,Smith PD,White J

    更新日期:1987-01-01 00:00:00

  • A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

    abstract::Fluorescence molecular tomography (FMT) is widely used in preclinical oncology research. FMT is the only imaging technique able to provide 3D distribution of fluorescent probes within thick highly scattering media. However, its integration into clinical medicine has been hampered by its low spatial resolution caused b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf96d

    authors: Nouizi F,Kwong TC,Ruiz J,Cho J,Chan YW,Ikemura K,Erkol H,Sampathkumaran U,Gulsen G

    更新日期:2019-01-22 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Controlled E-field gradient coils for MRI.

    abstract::Peripheral neural stimulation is a major problem in current gradient coil designs. Induced current problems in patients relate directly to gradient strength and modulation frequency. Present designs of gradient coil tend to limit ultra-high-speed imaging methods such as echo-planar imaging (EPI) and echo-volumar imagi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/7/001

    authors: Mansfield P,Haywood B

    更新日期:2008-04-07 00:00:00

  • Calculation of turnover rates in stable-isotope studies.

    abstract::Tserng and Kalhan have raised the question of the appropriate equation to use for the measurement of turnover rate in a stable-isotope study. In a comparison of glucose turnover measured with 2H-glucose and with 13C-glucose they used five apparently different equations and obtained conflicting answers. There is, howev...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/013

    authors: Wootton R,Ford GC,Cheng KN,Halliday D

    更新日期:1985-10-01 00:00:00

  • Infrasonic analysis of carotid vibration as a diagnostic method in carotid insufficiency syndrome.

    abstract::The infrasonic part of the spectrum of the carotid artery wall vibration in the neck was obtained. Differences between the spectral content and vibrational amplitude in normal and occluded carotids were found. The application of this technique in clinical practice could be useful in the detection of the carotid insuff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/011

    authors: Anastassiades AJ,Petounis AD

    更新日期:1976-01-01 00:00:00

  • An investigation using atomic force microscopy nanoindentation of dental enamel demineralization as a function of undissociated acid concentration and differential buffer capacity.

    abstract::Acidic drinks and foodstuffs can demineralize dental hard tissues, leading to a pathological condition known as dental erosion, which is of increasing clinical concern. The first step in enamel dissolution is a demineralization of the outer few micrometres of tissue, which results in a softening of the structure. The ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/003

    authors: Barbour ME,Shellis RP

    更新日期:2007-02-21 00:00:00

  • Volume estimation of low-contrast lesions with CT: a comparison of performances from a phantom study, simulations and theoretical analysis.

    abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/671

    authors: Li Q,Gavrielides MA,Zeng R,Myers KJ,Sahiner B,Petrick N

    更新日期:2015-01-21 00:00:00

  • On the accuracy and effectiveness of dose reconstruction for tomotherapy.

    abstract::Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the inci...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/303

    authors: Kapatoes JM,Olivera GH,Balog JP,Keller H,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • Integration of dynamic contrast-enhanced magnetic resonance imaging and T2-weighted imaging radiomic features by a canonical correlation analysis-based feature fusion method to predict histological grade in ductal breast carcinoma.

    abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fd3

    authors: Fan M,Liu Z,Xie S,Xu M,Wang S,Gao X,Li L

    更新日期:2019-10-23 00:00:00

  • Inverse treatment planning for an electronic brachytherapy system delivering anisotropic radiation therapy.

    abstract::An inverse radiation treatment planning algorithm for Sensus Healthcare's SculpturaTM electronic brachytherapy system has been designed. The algorithm makes use of simulated annealing to optimize the conformation number of the treatment plan. The highly anisotropic dose distributions produced by the SculpturaTM x-ray ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abda9a

    authors: Badali DS,Vainer Y,Ellenor CW,Mitchell CR,Fishman K,Soro N,Price R,Funk T

    更新日期:2021-01-11 00:00:00

  • Comments on 'Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation'.

    abstract::We comment on a previous article by Zhang and Newhauser (2009 Phys. Med. Biol. 54 1383-95) which presents several approximate ways of computing the water equivalent of an arbitrary degrader. First, we present a simple exact method which depends only on the range-energy relation of water and of the degrader material. S...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/55/9/L01

    authors: Gottschalk B

    更新日期:2010-05-07 00:00:00

  • Regional compensation for statistical maximum likelihood reconstruction error of PET image pixels.

    abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/14/4849

    authors: Forma J,Niemi JA,Ruotsalainen U

    更新日期:2013-07-21 00:00:00

  • Application of a CCD linear array camera in the quantification of tissue staining: NBT detection in ischaemic myocardium.

    abstract::A method was developed to quantify the intensity of tissue staining using a CCD (charge-coupled device) camera. Reflection spectra of NBT-stained (nitro-blue tetrazolium-stained) and unstained myocardium were recorded via fibre optics coupled to a CCD camera, connected to a microcomputer. The calculation of the intens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/007

    authors: Schröder T,Koch G,Schnabel PA,Hering JP,Bretschneider HJ,Richter J,Hellige G

    更新日期:1991-06-01 00:00:00

  • 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.

    abstract::Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/749

    authors: Chin E,Loewen SK,Nichol A,Otto K

    更新日期:2013-02-21 00:00:00

  • PDE-constrained LDDMM via geodesic shooting and inexact Gauss-Newton-Krylov optimization using the incremental adjoint Jacobi equations.

    abstract::The class of non-rigid registration methods proposed in the framework of PDE-constrained large deformation diffeomorphic metric mapping is a particularly interesting family of physically meaningful diffeomorphic registration methods. Inexact Gauss-Newton-Krylov optimization has shown an excellent numerical accuracy an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf598

    authors: Hernandez M

    更新日期:2019-01-07 00:00:00

  • Cadmium in man measured in vivo by x-ray fluorescence analysis.

    abstract::The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/004

    authors: Ahlgren L,Mattsson S

    更新日期:1981-01-01 00:00:00