Cadmium in man measured in vivo by x-ray fluorescence analysis.

Abstract:

:The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the detection of cadmium at various locations in a kidney has been studied. Because of the pronounced variation in sensitivity with depth in tissue, a measurement could be made selectively in the kidney cortex. The minimum detectable Cd concentration varies between 20 and 40 micrograms g-1 for distances between the skin and the kidney surface of 30 to 40 mm; this distance has a measured uncertainty of +/- 3 mm which gives rise to an uncertainty of +/- 30% in the estimated Cd concentration. The mean absorbed dose to the kidney during such a measurement is about 0.6 mGy. The X-ray fluorescence method is more advantageous than the alternative neutron capture gamma ray analysis technique as far as the total irradiation of the patient is concerned. The cadmium concentrations in the kidneys of five exposed persons were found to lie between 30 and 143 micrograms g-1.

journal_name

Phys Med Biol

authors

Ahlgren L,Mattsson S

doi

10.1088/0031-9155/26/1/004

subject

Has Abstract

pub_date

1981-01-01 00:00:00

pages

19-26

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

26

pub_type

杂志文章
  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • Ion-recombination correction for different ionization chambers in high dose rate flattening-filter-free photon beams.

    abstract::Recently, there has been an increased interest in flattening-filter-free (FFF) linear accelerators. Removal of the filter results in available dose rates up to 24 Gy min(-1) (for nominal energy 10 MV in depth of maximum dose, a source-surface distance of 100 cm and a field size of 10×10 cm2). To guarantee accurate rel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2819

    authors: Lang S,Hrbacek J,Leong A,Klöck S

    更新日期:2012-05-07 00:00:00

  • Fluorescence-enhanced three-dimensional lifetime imaging: a phantom study.

    abstract::Near-infrared fluorescence optical imaging has the unique opportunity of differentiating diseased lesions from normal lesions based upon environmentally indicated changes in the lifetime of a fluorescent imaging agent. In this paper, we demonstrate three-dimensional lifetime tomography using the gradient-based penalty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/14/009

    authors: Roy R,Godavarty A,Sevick-Muraca EM

    更新日期:2007-07-21 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • Relative determination of W-values for alpha particles in tissue-equivalent and other gases.

    abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/005

    authors: Krieger GL,Baum JW,Varma MN,Beach JL

    更新日期:1979-03-01 00:00:00

  • An analytical reconstruction model of the spread-out Bragg peak using laser-accelerated proton beams.

    abstract::With the development of laser technology, laser-driven proton acceleration provides a new method for proton tumor therapy. However, it has not been applied in practice because of the wide and decreasing energy spectrum of laser-accelerated proton beams. In this paper, we propose an analytical model to reconstruct the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6fce

    authors: Tao L,Zhu K,Zhu J,Xu X,Lin C,Ma W,Lu H,Zhao Y,Lu Y,Chen JE,Yan X

    更新日期:2017-07-07 00:00:00

  • Changes in optical properties of ex vivo rat prostate due to heating.

    abstract::This study examines the effectiveness of a single, first-order Arrhenius process in accurately modelling the thermally induced changes in the optical properties, particularly the reduced scattering coefficient, mu(s)', and the absorption coefficient, mu(a), of ex vivo rat prostate. Recent work has shown that mu(s)' ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/319

    authors: Skinner MG,Everts S,Reid AD,Vitkin IA,Lilge L,Sherar MD

    更新日期:2000-05-01 00:00:00

  • A control systems approach for the simulation of renal dynamic software phantoms for nuclear medicine.

    abstract::For renal dynamic studies, the COST B2 hybrid phantom is an example of an artificially created software phantom. Although this phantom is useful, it is not possible to implement the phantom in a self-consistent fashion to produce, for example, a collection of tracer in the bladder which is related to the flow from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/008

    authors: Houston AS,Sampson WF,Jose RM,Boyce JF

    更新日期:1999-02-01 00:00:00

  • Computed temperature distributions around ectatic capillaries exposed to yellow (578 nm) laser light.

    abstract::We have numerically modelled the thermal effects of yellow (577 or 578 nm) light illumination on the ectatic blood vessels of port wine stains. We investigated the effect of the laser treatment parameters of light irradiance and illumination time on the extent of coagulation (coagulation thickness) of the endothelial ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/9/010

    authors: Pickering JW,Butler PH,Ring BJ,Walker EP

    更新日期:1989-09-01 00:00:00

  • An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.

    abstract::Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8534

    authors: Capaldi DPI,Skinner LB,Dubrowski P,Yu AS

    更新日期:2020-06-10 00:00:00

  • Dosimetry robustness with stochastic optimization.

    abstract::All radiation therapy treatment planning relies on accurate dose calculation. Uncertainties in dosimetric prediction can significantly degrade an otherwise optimal plan. In this work, we introduce a robust optimization method which handles dosimetric errors and warrants for high-quality IMRT plans. Unlike other dose e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/11/010

    authors: Nohadani O,Seco J,Martin BC,Bortfeld T

    更新日期:2009-06-07 00:00:00

  • Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements.

    abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab13f2

    authors: Moghimirad E,Bamber J,Harris E

    更新日期:2019-04-23 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00

  • Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery.

    abstract::A micro-multileaf collimator (microMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the microMLC does not allow 'direct'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/305

    authors: Treuer H,Hoevels M,Luyken K,Hunsche S,Kocher M,Müller RP,Sturm V

    更新日期:2003-08-07 00:00:00

  • Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles.

    abstract::The objective of this work is to test analytical models to calculate the luminescence efficiency of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to heavy charged particles with energies relevant to space dosimetry and particle therapy. We used the track structure model to obtain an analytica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/437

    authors: Sawakuchi GO,Yukihara EG

    更新日期:2012-01-21 00:00:00

  • High-resolution fluence verification for treatment plan specific QA in ion beam radiotherapy.

    abstract::Ion beam radiotherapy exploits the finite range of ion beams and the increased dose deposition of ions toward the end of their range in material. This results in high dose conformation to the target region, which can be further increased using scanning ion beams. The standard method for patient-plan verification in io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/6/1725

    authors: Martišíková M,Brons S,Hesse BM,Jäkel O

    更新日期:2013-03-21 00:00:00

  • Improved scatter correction using adaptive scatter kernel superposition.

    abstract::Accurate scatter correction is required to produce high-quality reconstructions of x-ray cone-beam computed tomography (CBCT) scans. This paper describes new scatter kernel superposition (SKS) algorithms for deconvolving scatter from projection data. The algorithms are designed to improve upon the conventional approac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/22/007

    authors: Sun M,Star-Lack JM

    更新日期:2010-11-21 00:00:00

  • Dosimetry of 106Ru eye applicators with a p-type silicon detector.

    abstract::Beta emitting 106Ru-applicators are used to treat choroidal melanoma. In order to improve the accuracy and simplify the dosimetry of these applicators, the suitability of using a p-type silicon semiconductor detector has been investigated. The detector is calibrated in a low energy electron beam. An important property...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/7/005

    authors: Lax I

    更新日期:1991-07-01 00:00:00

  • In vivo and in vitro dielectric properties of feline tissues at low radiofrequencies.

    abstract::The dielectric constant and conductivity of muscle, liver, spleen and kidney of cats in vivo and in situ immediately following the animal's death were measured at frequencies from 10 kHz to 100 MHz. A novel multi-ring capacitive sensor and a computer-controlled automatic network analyser (ANA) were employed. The resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/007

    authors: Surowiec A,Stuchly SS,Keaney M,Swarup A

    更新日期:1986-08-01 00:00:00

  • The investigation of different cameras for in-beam PET imaging.

    abstract::In situ and in vivo treatment plan verification and beam monitoring as well as dose control during heavy-ion tumour therapy can be performed in principle by measurements of range distributions of beta(+)-emitting nuclei by means of PET techniques. For this purpose the performance of different types of positron camera ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/2/006

    authors: Pawelke J,Byars L,Enghardt W,Fromm WD,Geissel H,Hasch BG,Lauckner K,Manfrass P,Schardt D,Sobiella M

    更新日期:1996-02-01 00:00:00

  • Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

    abstract::Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registratio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa62c5

    authors: Uneri A,De Silva T,Goerres J,Jacobson MW,Ketcha MD,Reaungamornrat S,Kleinszig G,Vogt S,Khanna AJ,Osgood GM,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-21 00:00:00

  • DAVID--a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques.

    abstract::Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/013

    authors: Poppe B,Thieke C,Beyer D,Kollhoff R,Djouguela A,Rühmann A,Willborn KC,Harder D

    更新日期:2006-03-07 00:00:00

  • Applying a variable relative biological effectiveness (RBE) might affect the analysis of clinical trials comparing photon and proton therapy for prostate cancer.

    abstract::The purpose of this study was the evaluation of the impact of a variable relative biological effectiveness (RBE) compared to a constant RBE value of 1.1 in proton therapy prostate trials due to uncertainties in α/β ratio. Twenty patients receiving passive scattered proton therapy (PSPT) and fifteen patients receiving ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2144

    authors: Marteinsdottir M,Paganetti H

    更新日期:2019-06-05 00:00:00

  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac.

    abstract::In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current IMRT based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd66d

    authors: Kontaxis C,Woodhead PL,Bol GH,Lagendijk JJW,Raaymakers BW

    更新日期:2020-12-23 00:00:00

  • Filter materials for dose reduction in screen-film radiography.

    abstract::A computer program was developed to calculate both integral absorbed dose in a water phantom and entrance exposure, for the imaging of iodine contrast with x-ray intensifying screens. The effect of filtration of the x-ray beam on integral absorbed dose and entrance exposure was studied for 27 different filter material...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/6/001

    authors: Koedooder K,Venema HW

    更新日期:1986-06-01 00:00:00

  • Accurate Monte Carlo modelling of the back compartments of SPECT cameras.

    abstract::Today, new single photon emission computed tomography (SPECT) reconstruction techniques rely on accurate Monte Carlo (MC) simulations to optimize reconstructed images. However, existing MC scintillation camera models which usually include an accurate description of the collimator and crystal, lack correct implementati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/1/006

    authors: Rault E,Staelens S,Van Holen R,De Beenhouwer J,Vandenberghe S

    更新日期:2011-01-07 00:00:00

  • Exploration and application of phenomenological RBE models for proton therapy.

    abstract::The relative biological effectiveness (RBE) of protons varies with multiple physical and biological factors. Phenomenological RBE models have been developed to include such factors in the estimation of a variable RBE, in contrast to the clinically applied constant RBE of 1.1. In this study, eleven published phenomenol...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9db

    authors: Rørvik E,Fjæra LF,Dahle TJ,Dale JE,Engeseth GM,Stokkevåg CH,Thörnqvist S,Ytre-Hauge KS

    更新日期:2018-09-13 00:00:00

  • A feasibility study of the use of fluorescence bronchoscopy for localization of small lung tumours.

    abstract::The possible use of fluorescence bronchoscopy for localization of bronchogenic tumours at the carcinoma in situ stage has been investigated. The target lesion is 80 micrometer thick with a mass of 250 microgram, containing 250 pg of haematoporphyrin derivative. The injected haematoporphyrin-derivative is preferentiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/014

    authors: Profio AE,Doiron DR

    更新日期:1977-09-01 00:00:00

  • Application of a CCD linear array camera in the quantification of tissue staining: NBT detection in ischaemic myocardium.

    abstract::A method was developed to quantify the intensity of tissue staining using a CCD (charge-coupled device) camera. Reflection spectra of NBT-stained (nitro-blue tetrazolium-stained) and unstained myocardium were recorded via fibre optics coupled to a CCD camera, connected to a microcomputer. The calculation of the intens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/007

    authors: Schröder T,Koch G,Schnabel PA,Hering JP,Bretschneider HJ,Richter J,Hellige G

    更新日期:1991-06-01 00:00:00