Changes in optical properties of ex vivo rat prostate due to heating.

Abstract:

:This study examines the effectiveness of a single, first-order Arrhenius process in accurately modelling the thermally induced changes in the optical properties, particularly the reduced scattering coefficient, mu(s)', and the absorption coefficient, mu(a), of ex vivo rat prostate. Recent work has shown that mu(s)' can increase as much as five-fold due to thermal coagulation, and the observed change in mu(s)' has been modelled well according to a first-order rate process in albumen. Conversely, optical property measurements conducted using pig liver suggest that this change in mu(s)' cannot suitably be described using a single rate parameter. In canine prostate, measurements have indicated that while the absorption coefficient varies with temperature, it does not do so according to first-order kinetics. A double integrating sphere system was used to measure the reflectance and transmittance of light at 810 nm through a thin sample of prostate. Using prostate samples collected from Sprague Dawley rats, optical properties were measured at a constant elevated temperature. Tissue samples were measured over the range 54-83 degrees C. The optical properties of the sample were determined through comparison with reflectance and transmittance values predicted by a Monte Carlo simulation of light propagation in turbid media. A first order Arrhenius model was applied to the observed change in mu(s)' and mu(a) to determine the rate process parameters for thermal coagulation. The measured rate coefficients were Ea = (7.18 +/- 1.74) x 10(4) J mol(-1) and Afreq = 3.14 x 10(8) s(-1) for mu(s)'. It was determined that the change in mu(s)' is well described by a single first-order rate process. Similar analysis performed on the changes in mu(a) due to increased temperatures yielded Ea = (1.01 +/- 0.35) x 10(5) J mol(-1) and Afreq = 8.92 x 10(12) s(-1). The results for mu(a) suggest that the Arrhenius model may be applicable to the changes in absorption.

journal_name

Phys Med Biol

authors

Skinner MG,Everts S,Reid AD,Vitkin IA,Lilge L,Sherar MD

doi

10.1088/0031-9155/45/5/319

subject

Has Abstract

pub_date

2000-05-01 00:00:00

pages

1375-86

issue

5

eissn

0031-9155

issn

1361-6560

journal_volume

45

pub_type

杂志文章
  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • Breast composition measurements using retrospective standard mammogram form (SMF).

    abstract::The standard mammogram form (SMF) representation of an x-ray mammogram is a standardized, quantitative representation of the breast from which the volume of non-fat tissue and breast density can be easily estimated, both of which are of significant interest in determining breast cancer risk. Previous theoretical analy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/001

    authors: Highnam R,Pan X,Warren R,Jeffreys M,Davey Smith G,Brady M

    更新日期:2006-06-07 00:00:00

  • Reassessing the clinical efficacy of two MR quantitative DSC PWI CBF algorithms following cross-calibration with PET images.

    abstract::Clinical cerebral blood flow (CBF) maps generated through dynamic- susceptibility contrast (DSC) magnetic resonance (MR) perfusion imaging are currently cross-calibrated with PET studies. The cross-calibration is achieved by rescaling the MR CBF values so that normal white matter CBF corresponds to 22 ml/100 g/min. Ex...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/6/014

    authors: Chen JJ,Frayne R,Smith MR

    更新日期:2005-03-21 00:00:00

  • The local noise property in positron volume imaging and optimal conditions for the signal-to-noise ratio of the 3D reconstructed image.

    abstract::The local noise property of a 3D PET reconstructed image is investigated for a uniform-activity sphere distributed in a constantly attenuating spherical object. The positional dependence of the statistical noise is approximately derived and calculated for some special cases. It is suggested that a larger diameter of t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/015

    authors: Murayama H,Nohara N

    更新日期:1997-01-01 00:00:00

  • Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine.

    abstract::In this paper we present the results of a dosimetric evaluation of a 2D ionization chamber array with the objective of its implementation for quality assurance in clinical routine. The pixel ionization chamber MatriXX (Scanditronix Wellhofer, Germany) consists of 32x32 chambers with a distance of 7.6 mm between chambe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/023

    authors: Herzen J,Todorovic M,Cremers F,Platz V,Albers D,Bartels A,Schmidt R

    更新日期:2007-02-21 00:00:00

  • Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector.

    abstract::A method of computing theoretical X-ray spectra in the range 30-150 kV is presented. The theoretical spectra are compared with constant potential, high resolution spectra from a tungsten target measured with a Ge(Li) detector, for a range of target angles, tube voltage and filtrations. Above 100 kV the spectra were al...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/3/002

    authors: Birch R,Marshall M

    更新日期:1979-05-01 00:00:00

  • Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP).

    abstract::Microbeam radiation therapy (MRT) is a pre-clinical, spatially-fractionated treatment modality noted for its ability to achieve a large differential response between normal and tumoral tissues. In the present study, TOPAS Monte Carlo (MC) simulations were used to optimize the design of a compact, affordable multi-slit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad7e2

    authors: Esplen NM,Chergui L,Johnstone CD,Bazalova-Carter M

    更新日期:2018-08-29 00:00:00

  • The transformation method for the MIRD absorbed fraction as applied to various physiques.

    abstract::A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fracti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/4/006

    authors: Yamaguchi H,Kato Y,Shiragai A

    更新日期:1975-07-01 00:00:00

  • Dose distribution to spinal structures from intrathecally administered yttrium-90.

    abstract::Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of (131)I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as (90)Y replaces (131)I. The purpose of this study is to compare and quantitatively e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/014

    authors: Mardirossian G,Hall M,Montebello J,Stevens P

    更新日期:2006-01-07 00:00:00

  • Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET.

    abstract::The interest in positron emission tomography (PET) and particularly in hybrid integrated PET/CT systems has significantly increased in the last few years due to the improved quality of the obtained images. Nevertheless, one of the most important limits of the PET imaging technique is still its poor spatial resolution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/012

    authors: Rapisarda E,Bettinardi V,Thielemans K,Gilardi MC

    更新日期:2010-07-21 00:00:00

  • The dosimetric impact of dental implants on head-and-neck volumetric modulated arc therapy.

    abstract::This work aims to investigate the dosimetric impact of dental implants on volumetric modulated arc therapy (VMAT) for head-and-neck patients and to evaluate the effectiveness of using the material's electron-density ratio for the correction. An in-house Monte Carlo (MC) code was utilized for the dose calculation to ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1027

    authors: Lin MH,Li J,Price RA Jr,Wang L,Lee CC,Ma CM

    更新日期:2013-02-21 00:00:00

  • A temperature-based feedback control system for electromagnetic phased-array hyperthermia: theory and simulation.

    abstract::A hybrid proportional-integral-in-time and cost-minimizing-in-space feedback control system for electromagnetic, deep regional hyperthermia is proposed. The unique features of this controller are that (1) it uses temperature, not specific absorption rate, as the criterion for selecting the relative phases and amplitud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/5/306

    authors: Kowalski ME,Jin JM

    更新日期:2003-03-07 00:00:00

  • Continuous bed motion on clinical scanner: design, data correction, and reconstruction.

    abstract::With the addition of variable bed speed capabilities, continuous bed motion (CBM) becomes an acquisition generalization for axial sensitivity modeling and therefore a flexible tool in axial local image quality adjustment. In this paper, we describe the principles behind CBM mode planning and its influence on image rec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/6153

    authors: Panin VY,Smith AM,Hu J,Kehren F,Casey ME

    更新日期:2014-10-21 00:00:00

  • The energy-dependent electron loss model for pencil beam dose kernels.

    abstract::The 'monoenergetic' electron loss model was derived in a previous work to account for pathlength straggling in the Fermi-Eyges pencil beam problem. In this paper, we extend this model to account for energy-loss straggling and secondary knock-on electron transport in order to adequately predict a depth dose curve. To m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/313

    authors: Chvetsov AV,Sandison GA,Yeboah C

    更新日期:2000-10-01 00:00:00

  • Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

    abstract::Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa26

    authors: Giger AT,Krieger M,Jud C,Duetschler A,Salomir R,Bieri O,Bauman G,Nguyen D,Weber DC,Lomax AJ,Zhang Y,Cattin PC

    更新日期:2020-07-28 00:00:00

  • Kinetic filtering of [(18)F]Fluorothymidine in positron emission tomography studies.

    abstract::[(18)F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/010

    authors: Gray KR,Contractor KB,Kenny LM,Al-Nahhas A,Shousha S,Stebbing J,Wasan HS,Coombes RC,Aboagye EO,Turkheimer FE,Rosso L

    更新日期:2010-02-07 00:00:00

  • Navigated non-contact fluorescence tomography.

    abstract::A non-contact approach for diffuse optical tomography (DOT) has been developed for on-demand image updates using surgical navigation technology. A stereoscopic optical tracker provides real-time localization of reflective spheres mounted to a laser diode and near-infrared camera. Standard camera calibration is combine...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1f33

    authors: Daly MJ,Wilson BC,Irish JC,Jaffray DA

    更新日期:2019-07-05 00:00:00

  • Relative electron density determination using a physics based parameterization of photon interactions in medical DECT.

    abstract::Radiotherapy and particle therapy treatment planning require accurate knowledge of the electron density and elemental composition of the tissues in the beam path to predict the local dose deposition. We describe a method for the analysis of dual energy computed tomography (DECT) images that provides the electron densi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/9/3825

    authors: van Abbema JK,van Goethem MJ,Greuter MJ,van der Schaaf A,Brandenburg S,van der Graaf ER

    更新日期:2015-05-07 00:00:00

  • Thermal effects of radiation from cellular telephones.

    abstract::A finite element thermal model of the head has been developed to calculate temperature rises generated in the brain by radiation from cellular telephones and similar electromagnetic devices. A 1 mm resolution MRI dataset was segmented semiautomatically, assigning each volume element to one of ten tissue types. A finit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/321

    authors: Wainwright P

    更新日期:2000-08-01 00:00:00

  • Dose effect of guidewire position in intravascular brachytherapy.

    abstract::It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The purpose of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/10/309

    authors: Shih R,Hsu WL,Li XA

    更新日期:2002-05-21 00:00:00

  • Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera.

    abstract::Prompt γ-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/7881

    authors: Priegnitz M,Barczyk S,Nenoff L,Golnik C,Keitz I,Werner T,Mein S,Smeets J,Vander Stappen F,Janssens G,Hotoiu L,Fiedler F,Prieels D,Enghardt W,Pausch G,Richter C

    更新日期:2016-11-21 00:00:00

  • Optimization of the accuracy of retention and washout measurements of 99mTc-Sestamibi from breast tumours using an anthropomorphic phantom.

    abstract::Quantifying the retention or washout of (99m)Tc-Sestamibi (MIBI) in breast tumours in vivo may provide a basis for predicting the chemotherapy response. The aim of this study is to investigate the variations and limitations of the different methods used to quantify these parameters. A phantom was developed that allowe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/9/013

    authors: Marshall C,Griffiths PA

    更新日期:2005-05-07 00:00:00

  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00

  • Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    abstract::In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, notice...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/19/003

    authors: Karampatzakis A,Samaras T

    更新日期:2010-10-07 00:00:00

  • A method for converting dose-to-medium to dose-to-tissue in Monte Carlo studies of gold nanoparticle-enhanced radiotherapy.

    abstract::Gold nanoparticles (GNPs) have shown potential in recent years as a means of therapeutic dose enhancement in radiation therapy. However, a major challenge in moving towards clinical implementation is the exact characterisation of the dose enhancement they provide. Monte Carlo studies attempt to explore this property, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/5/2014

    authors: Koger B,Kirkby C

    更新日期:2016-03-07 00:00:00

  • SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms.

    abstract::This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa77ea

    authors: Cros M,Joemai RMS,Geleijns J,Molina D,Salvadó M

    更新日期:2017-07-17 00:00:00

  • Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model.

    abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4364

    authors: Šarolić A,Živković Z,Reilly JP

    更新日期:2016-06-21 00:00:00

  • Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications.

    abstract::Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, makin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1c37

    authors: Du J,Bai X,Cherry SR

    更新日期:2019-08-07 00:00:00

  • Multi-layer imager design for mega-voltage spectral imaging.

    abstract::The architecture of multi-layer imagers (MLIs) can be exploited to provide megavoltage spectral imaging (MVSPI) for specific imaging tasks. In the current work, we investigated bone suppression and gold fiducial contrast enhancement as two clinical tasks which could be improved with spectral imaging. A method based on...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabe21

    authors: Myronakis M,Hu YH,Fueglistaller R,Wang A,Baturin P,Huber P,Morf D,Star-Lack J,Berbeco R

    更新日期:2018-05-10 00:00:00

  • A neural network regression model for relative dose computation.

    abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/307

    authors: Wu X,Zhu Y

    更新日期:2000-04-01 00:00:00