Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

Abstract:

:The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 and 20 W kg(-1)) have been applied to the mice inside the 'Ferris Wheel' exposure setup at 22 +/- 2 degrees C and 30-70% humidity. The thermal responses were assessed by measurement of the rectal temperature prior, during and after the 2 h exposure session. For B6C3F1 mice, the thermal response was examined for three different weight groups (20 g, 24 g, 29 g), both genders and for pregnant mice. Additionally, NMRI mice with a weight of 36 g were investigated for an interstrain comparison. The thermal regulatory threshold of in-tube restrained mice was found at SAR levels between 2 W kg(-1) and 5 W kg(-1), whereas the breakdown of regulation was determined at 10.1 +/- 4.0 W kg(-1)(K = 2) for B6C3F1 mice and 7.7 +/- 1.6 W kg(-1)(K = 2) for NMRI mice. Based on a simplified power balance equation, the thresholds show a clear dependence upon the metabolic rate and weight. NMRI mice were more sensitive to thermal stress and respond at lower SAR values with regulation and breakdown. The presented data suggest that the thermal breakdown for in-tube restrained mice, whole-body exposed to radiofrequency fields, may occur at SAR levels of 6 W kg(-1)(K = 2) at laboratory conditions.

journal_name

Phys Med Biol

authors

Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

doi

10.1088/0031-9155/50/21/017

subject

Has Abstract

pub_date

2005-11-07 00:00:00

pages

5203-15

issue

21

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(05)93668-3

journal_volume

50

pub_type

杂志文章
  • Respiratory liver motion estimation and its effect on scanned proton beam therapy.

    abstract::Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1779

    authors: Zhang Y,Boye D,Tanner C,Lomax AJ,Knopf A

    更新日期:2012-04-07 00:00:00

  • Assessment of the exposure to biologically effective UV radiation using a dosimetric technique to evaluate the solar spectrum.

    abstract::A cost-effective method employing polysulphone, nalidixic acid, 8-methoxypsoralen and phenothiazine as UV dosimeters is presented for evaluating the UV spectrum. The exposure measured by each dosimeter is a function of the source spectrum and the spectral response of the material. Each material has a different spectra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/005

    authors: Parisi AV,Wong JC,Moore GI

    更新日期:1997-01-01 00:00:00

  • Dielectric properties of porcine glands, gonads and body fluids.

    abstract::Dielectric properties of porcine glandular tissues and gonads (in vivo) and body fluids (in vitro) have been obtained in the frequency range of 50 MHz to 20 GHz. The experimental data were fitted to a two term Cole-Cole expression. The data presented complement the available dielectric properties of tissues in the lit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/N339

    authors: Peyman A,Gabriel C

    更新日期:2012-10-07 00:00:00

  • Normal levels of total body sodium and chlorine by neutron activation analysis.

    abstract::In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/3/002

    authors: Kennedy NS,Eastell R,Smith MA,Tothill P

    更新日期:1983-03-01 00:00:00

  • Verification of absolute dose rates for intravascular brachytherapy beta sources.

    abstract::The absolute dose rate around beta sources for intravascular brachytherapy was measured with thin thermoluminescent (TL) dosimeters and radiochromic film. The calibration of these dosimeters was performed at the dose maximum in a 6 MeV electron beam of a linear accelerator. Compared to the values given by the manufact...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/311

    authors: Piessens M,Reynaert N

    更新日期:2000-08-01 00:00:00

  • Chemically tuned linear energy transfer dependent quenching in a deformable, radiochromic 3D dosimeter.

    abstract::Most solid-state detectors, including 3D dosimeters, show lower signal in the Bragg peak than expected, a process termed quenching. The purpose of this study was to investigate how variation in chemical composition of a recently developed radiochromic, silicone-based 3D dosimeter influences the observed quenching in p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa512a

    authors: Høye EM,Skyt PS,Balling P,Muren LP,Taasti VT,Swakoń J,Mierzwińska G,Rydygier M,Bassler N,Petersen JB

    更新日期:2017-02-21 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.

    abstract::A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/011

    authors: Fogliata A,Vanetti E,Albers D,Brink C,Clivio A,Knöös T,Nicolini G,Cozzi L

    更新日期:2007-03-07 00:00:00

  • An analysis of breast motion using high-frequency, dense surface points captured by an optical sensor during radiotherapy treatment delivery.

    abstract::Patient motion is an important factor affecting the quality of external beam radiotherapy in breast patients. We analyse the motion of a dense set of surface points on breast patients throughout their treatment schedule to assess the magnitude and stability of motion, in particular, with respect to breast volume. We u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/21/005

    authors: Price GJ,Sharrock PJ,Marchant TE,Parkhurst JM,Burton D,Jain P,Price P,Moore CJ

    更新日期:2009-11-07 00:00:00

  • Measurement and correction of the effects of lag on contrast-detail test results in fluoroscopy.

    abstract::Persistence of the video signal between TV frames, an effect also known as image lag, can lead to anomalously good contrast-detail test results for fluoroscopy systems. In this practical paper, a simple method is described which quantifies lag in fluoroscopy systems and corrects for its effect on threshold contrast. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:

    authors: Marshall NW,Kotre CJ

    更新日期:2002-03-21 00:00:00

  • A novel high-throughput irradiator for in vitro radiation sensitivity bioassays.

    abstract::This paper describes the development and characterization of a fully automated in vitro cell irradiator using an electronic brachytherapy source to perform radiation sensitivity bioassays. This novel irradiator allows complex variable dose and dose rate schemes to be delivered to multiple wells of 96-well culture plat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/6/1459

    authors: Fowler TL,Fulkerson RK,Micka JA,Kimple RJ,Bednarz BP

    更新日期:2014-03-21 00:00:00

  • SiPM signal readout for inter-crystal scatter event identification in PET detectors.

    abstract::In positron emission tomography (PET) with pixelated detectors, a significant number of annihilation photons interact with scintillation crystals through single or multiple Compton scattering events. When these partial energy depositions occur across multiple crystal elements, we call them inter-crystal scatter (ICS) ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba8b4

    authors: Park H,Lee JS

    更新日期:2020-10-21 00:00:00

  • Developing a 'multiPatchPET' system in GATE for a PET system design with irregular geometries.

    abstract::This work modified the commonly used Monte Carlo tool package GATE by developing a new 'multiPatchPET' system so that GATE users can easily simulate PET systems with irregular geometries. The motivation was to design a brain PET scanner with high sensitivity. It is known that compact PET scanners with a large solid co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad8fd

    authors: Chen G,Weng F,Hong X,Tao W,Zhao Z,Peng Q,Huang Q

    更新日期:2018-09-06 00:00:00

  • Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator.

    abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1375

    authors: Bol GH,Hissoiny S,Lagendijk JJ,Raaymakers BW

    更新日期:2012-03-07 00:00:00

  • Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

    abstract::A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6241

    authors: Vandecasteele J,De Deene Y

    更新日期:2013-09-21 00:00:00

  • Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

    abstract::In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/N209

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,Greer PB

    更新日期:2012-06-21 00:00:00

  • Intraventricular vector flow mapping-a Doppler-based regularized problem with automatic model selection.

    abstract::We propose a regularized least-squares method for reconstructing 2D velocity vector fields within the left ventricular cavity from single-view color Doppler echocardiographic images. Vector flow mapping is formulated as a quadratic optimization problem based on an [Formula: see text]-norm minimization of a cost functi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7fe7

    authors: Assi KC,Gay E,Chnafa C,Mendez S,Nicoud F,Abascal JFPJ,Lantelme P,Tournoux F,Garcia D

    更新日期:2017-08-11 00:00:00

  • Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT).

    abstract::In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/318

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-07 00:00:00

  • Assessment of the effects of pixel loss on image quality in direct digital radiography.

    abstract::Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitive image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/008

    authors: Padgett R,Kotre CJ

    更新日期:2004-03-21 00:00:00

  • Analysis of a large number of clinical studies for breast cancer radiotherapy: estimation of radiobiological parameters for treatment planning.

    abstract::Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on emp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,meta分析

    doi:10.1088/0031-9155/48/20/004

    authors: Guerrero M,Li XA

    更新日期:2003-10-21 00:00:00

  • A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping.

    abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/014

    authors: Reinsberg SA,Doran SJ,Charles-Edwards EM,Leach MO

    更新日期:2005-06-07 00:00:00

  • Locally linear constraint based optimization model for material decomposition.

    abstract::Dual spectral computed tomography (DSCT) has a superior material distinguishability than the conventional single spectral computed tomography (SSCT). However, the decomposition process is an illposed problem, which is sensitive to noise. Thus, the decomposed image quality is degraded, and the corresponding signal-to-n...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8e13

    authors: Wang Q,Zhu Y,Yu H

    更新日期:2017-10-19 00:00:00

  • Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancer.

    abstract::Image-guided radiation therapy using implanted fiducial markers is a common solution for prostate localization to improve targeting accuracy. However, fiducials that are typically used for conventional photon radiotherapy cause large dose perturbations in patients who receive proton radiotherapy. A proposed solution h...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/S13

    authors: Cheung J,Kudchadker RJ,Zhu XR,Lee AK,Newhauser WD

    更新日期:2010-12-07 00:00:00

  • Correction factors for parallel-plate chambers used in plastic phantoms in electron dosimetry.

    abstract::In electron beam dosimetry using parallel-plate chambers solid phantoms are sometimes necessary. To obtain the dose to water from the ionization obtained in the solid phantom, fluence correction factors and perturbation factors have to be applied. In this study fluence factors in a perturbation free geometry have been...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/007

    authors: Nilsson B,Montelius A,Andreo P,Johansson J

    更新日期:1997-11-01 00:00:00

  • Staging of cervical cancer based on tumor heterogeneity characterized by texture features on (18)F-FDG PET images.

    abstract::The aim of the study is to assess the staging value of the tumor heterogeneity characterized by texture features and other commonly used semi-quantitative indices extracted from (18)F-FDG PET images of cervical cancer (CC) patients. Forty-two patients suffering CC at different stages were enrolled in this study. First...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5123

    authors: Mu W,Chen Z,Liang Y,Shen W,Yang F,Dai R,Wu N,Tian J

    更新日期:2015-07-07 00:00:00

  • Characterization of a single LSO crystal layer high resolution research tomograph.

    abstract::The purpose of this study was to determine the performance of a single lutetium oxy-orthosilicate (LSO) crystal layer High Resolution Research Tomograph (HRRT) positron emission tomography (PET) scanner. The HRRT is a high resolution PET scanner designed for human brain and small animal imaging. The scanner consists o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/4/302

    authors: Boellaard R,Buijs F,de Jong HW,Lenox M,Gremillion T,Lammertsma AA

    更新日期:2003-02-21 00:00:00

  • PBS machine interlocks using EWMA.

    abstract::Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could incr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/400

    authors: Clasie BM,Kooy HM,Flanz JB

    更新日期:2016-01-07 00:00:00

  • Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning.

    abstract::Following the publication of ICRU Report 50, the concepts of GTV (gross tumour volume). CTV (clinical target volume) and PTV (planning target volume) are being used in radiotherapy planning with increasing frequency. In 3D planning, the GTV (or CTV) is normally outlined by the clinician in CT or MRI slices. The PTV is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/4/011

    authors: Stroom JC,Storchi PR

    更新日期:1997-04-01 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • Symmetries of the 2D magnetic particle imaging system matrix.

    abstract::In magnetic particle imaging (MPI), the relation between the particle distribution and the measurement signal can be described by a linear system of equations. For 1D imaging, it can be shown that the system matrix can be expressed as a product of a convolution matrix and a Chebyshev transformation matrix. For multidi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4033

    authors: Weber A,Knopp T

    更新日期:2015-05-21 00:00:00