Developing a 'multiPatchPET' system in GATE for a PET system design with irregular geometries.

Abstract:

:This work modified the commonly used Monte Carlo tool package GATE by developing a new 'multiPatchPET' system so that GATE users can easily simulate PET systems with irregular geometries. The motivation was to design a brain PET scanner with high sensitivity. It is known that compact PET scanners with a large solid coverage angle can achieve high sensitivity with fewer scintillation detectors, and thus have the potential to provide better image quality in brain PET imaging than conventional ring PET scanners. However, considering a straightforward example with the largest possible solid angle, a spherical PET scanner is hard to manufacture. A more practical alternative would be a sphere-like polyhedral PET scanner with flat detector patches. Moreover, when monolithic scintillators are chosen to construct these flat detector modules, detection efficiency is further improved. Thus, we plan to design a sphere-like polyhedral PET scanner made up of monolithic scintillators. Unfortunately, in our design study, we found that simulating such a scanner with the latest GATE version (8.0) was not trivial, since no predefined systems could be used. In this work we introduced a 'multiPatchPET' system to GATE, which we and other GATE users will be able to use to develop PET scanners with any irregular geometry and any shape of patch. To validate our modification, a single block detector and an mCT scanner were simulated via both the original 'ecat' system and the new 'multiPatchPET' system. The results show no difference in terms of the detecting efficiency and reconstruction image. Then we used the 'multiPatchPET' system to simulate an 86 surface polyhedral brain PET scanner. Compared with two cylindrical brain scanners, the polyhedral brain scanner shows a higher sensitivity and has fewer noisy images. Thus, it was proved that our modification, which is accessible to the nuclear imaging research community, equipped GATE with a powerful and user-friendly tool to simulate complex scanners with irregular patches easily.

journal_name

Phys Med Biol

authors

Chen G,Weng F,Hong X,Tao W,Zhao Z,Peng Q,Huang Q

doi

10.1088/1361-6560/aad8fd

subject

Has Abstract

pub_date

2018-09-06 00:00:00

pages

17NT02

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

杂志文章
  • Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes.

    abstract::The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scinti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/21/008

    authors: Jeong MH,Choi Y,Chung YH,Song TY,Jung JH,Hong KJ,Min BJ,Choe YS,Lee KH,Kim BT

    更新日期:2004-11-07 00:00:00

  • Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function.

    abstract::The Patlak graphical method is widely used in parametric imaging for modeling irreversible radiotracer kinetics in dynamic PET. The net influx rate of radiotracer can be determined from the slope of the Patlak plot. The implementation of the standard Patlak method requires the knowledge of full-time input function fro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad444

    authors: Zuo Y,Qi J,Wang G

    更新日期:2018-08-10 00:00:00

  • On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

    abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/001

    authors: Kissick MW,Flynn RT,Westerly DC,Hoban PW,Mo X,Soisson ET,McCall KC,Mackie TR,Jeraj R

    更新日期:2008-09-21 00:00:00

  • Filter materials for dose reduction in screen-film radiography.

    abstract::A computer program was developed to calculate both integral absorbed dose in a water phantom and entrance exposure, for the imaging of iodine contrast with x-ray intensifying screens. The effect of filtration of the x-ray beam on integral absorbed dose and entrance exposure was studied for 27 different filter material...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/6/001

    authors: Koedooder K,Venema HW

    更新日期:1986-06-01 00:00:00

  • Measuring the acoustoelectric interaction constant using ultrasound current source density imaging.

    abstract::Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5929

    authors: Li Q,Olafsson R,Ingram P,Wang Z,Witte R

    更新日期:2012-10-07 00:00:00

  • Dosimetry comparison and characterisation of an Al K ultrasoft x-ray beam from an MRC cold-cathode source.

    abstract::Ultrasoft x-rays of 0.3-5 keV have provided a unique tool for the investigation of intracellular mechanisms of radiation action in biological organisms, including mammalian cells. However, their use presents unique practical problems in dosimetry and experimental design. Detailed interpretation of the biological resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/002

    authors: Hoshi M,Goodhead DT,Brenner DJ,Bance DA,Chmielewski JJ,Paciotti MA,Bradbury JN

    更新日期:1985-10-01 00:00:00

  • Effects of particle diameter and magnetocrystalline anisotropy on magnetic relaxation and magnetic particle imaging performance of magnetic nanoparticles.

    abstract::The dynamic magnetization of immobilized spherical single-domain magnetic nanoparticles (MNPs) with uniaxial or cubic magnetocrystalline anisotropy was studied computationally by executing simulations based on the Landau-Lifshitz-Gilbert (LLG) equation. For situations when a static magnetic field was suddenly applied ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5b83

    authors: Zhao Z,Garraud N,Arnold DP,Rinaldi C

    更新日期:2020-01-17 00:00:00

  • STIR: software for tomographic image reconstruction release 2.

    abstract::We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to var...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/867

    authors: Thielemans K,Tsoumpas C,Mustafovic S,Beisel T,Aguiar P,Dikaios N,Jacobson MW

    更新日期:2012-02-21 00:00:00

  • Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

    abstract::The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9501

    authors: Giménez-Alventosa V,Giménez V,Ballester F,Vijande J,Andreo P

    更新日期:2020-10-07 00:00:00

  • GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.

    abstract::In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/4987

    authors: Lemaréchal Y,Bert J,Falconnet C,Després P,Valeri A,Schick U,Pradier O,Garcia MP,Boussion N,Visvikis D

    更新日期:2015-07-07 00:00:00

  • Improved procedure for neuromagnetic localisation.

    abstract::We describe an improved algorithm for localising equivalent sources of biomagnetic fields in the human brain. The algorithm is an improvement over the sphere model in that it considers two distinct surfaces: an ellipsoid, to model the region of the skull on which the sensors are placed, and a sphere as the medium in w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/017

    authors: Pistella F,Barone P,Narici L,Ocello N,Pizzella V,Romani GL

    更新日期:1987-01-01 00:00:00

  • Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung.

    abstract::Cone-beam computed tomography (CBCT) has rapidly become a clinically useful imaging modality for image-guided radiation therapy. Unfortunately, CBCT images of the thorax are susceptible to artefacts due to scattered photons, beam hardening, lag in data acquisition, and respiratory motion during a slow scan. These limi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/4157

    authors: Disher B,Hajdok G,Wang A,Craig J,Gaede S,Battista JJ

    更新日期:2013-06-21 00:00:00

  • An alternative to gamma histograms for ROI-based quantitative dose comparisons.

    abstract::An alternative to gamma (gamma) histograms for ROI-based quantitative comparisons of dose distributions using the gamma concept is proposed. The method provides minimum values of dose difference and distance-to-agreement such that a pre-set fraction of the region of interest passes the gamma test. Compared to standard...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N03

    authors: Dvorak P

    更新日期:2009-06-21 00:00:00

  • Photon quality correction factors for ionization chambers in an epithermal neutron beam.

    abstract::Photon quality correction factors (kQy) for ionization chamber photon dosimetry in an epithermal neutron beam were determined according to a modified absorbed dose to water formalism which was extended to mixed radiation fields. We have studied two commercially available ionization chambers in the epithermal neutron b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/14/303

    authors: Munck af Rosenschöld PM,Ceberg CP,Giusti V,Andreo P

    更新日期:2002-07-21 00:00:00

  • Measurement of scattered radiation in a volumetric 64-slice CT scanner using three experimental techniques.

    abstract::Compton scatter poses a significant threat to volumetric x-ray computed tomography, bringing cupping and streak artefacts thus impacting qualitative and quantitative imaging procedures. To perform appropriate scatter compensation, it is necessary to estimate the magnitude and spatial distribution of x-ray scatter. The...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/010

    authors: Akbarzadeh A,Ay MR,Ghadiri H,Sarkar S,Zaidi H

    更新日期:2010-04-21 00:00:00

  • Report of the IPSM working party on low- and medium-energy x-ray dosimetry. Institute of Physical Sciences in Medicine.

    abstract::New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the IAEA in 1987. These are not considered to possess sufficient support from other s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/8/001

    authors:

    更新日期:1991-08-01 00:00:00

  • Dose distribution measurements by MRI of a phantom containing lung tissue equivalent compartments made of ferrous sulphate gel.

    abstract::Gel dosimetry based on magnetic resonance imaging (MRI) has previously been shown to provide verification of calculated dose distributions in soft tissue equivalent homogeneous phantoms. This study demonstrates how measurements of dose distribution can also be achieved in a phantom containing porous, lung-equivalent, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/303

    authors: Olberg S,Skretting A,Bruland O,Olsen DR

    更新日期:2000-10-01 00:00:00

  • Breast composition measurements using retrospective standard mammogram form (SMF).

    abstract::The standard mammogram form (SMF) representation of an x-ray mammogram is a standardized, quantitative representation of the breast from which the volume of non-fat tissue and breast density can be easily estimated, both of which are of significant interest in determining breast cancer risk. Previous theoretical analy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/001

    authors: Highnam R,Pan X,Warren R,Jeffreys M,Davey Smith G,Brady M

    更新日期:2006-06-07 00:00:00

  • Experimental 3D dosimetry around a high-dose-rate clinical 192Ir source using a polyacrylamide gel (PAG) dosimeter.

    abstract::It is well known that the experimental dosimetry of brachytherapy sources presents a challenge. Depending on the particular-dosimeter used, measurements can suffer from poor spatial resolution (ion chambers), lack of 3D information (film) or errors due to the presence of the dosimeter itself distorting the radiation f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/305

    authors: McJury M,Tapper PD,Cosgrove VP,Murphy PS,Griffin S,Leach MO,Webb S,Oldham M

    更新日期:1999-10-01 00:00:00

  • In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies.

    abstract::We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer cleara...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/8/302

    authors: Cheung C,Culver JP,Takahashi K,Greenberg JH,Yodh AG

    更新日期:2001-08-01 00:00:00

  • Initial assessment of a simple system for frequency domain diffuse optical tomography.

    abstract::Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/10/011

    authors: Pogue BW,Patterson MS,Jiang H,Paulsen KD

    更新日期:1995-10-01 00:00:00

  • Optical-thermal characterization of cutaneous transilluminators.

    abstract::In recent years, there has been an increase in the popularity of light-emitting diode (LED)-based, battery-powered transilluminators (BPTs) for facilitating transdermal vascular access in adults and neonates. BPTs are believed to have lower potential for inducing skin burns than prior devices based on high-power broad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/22/008

    authors: Pfefer TJ,Mehrabi A,James R,Landry R,Weininger S,Chang I,Kaufman D,Miller S

    更新日期:2009-11-21 00:00:00

  • Dosimetry system for the irradiation of thin biological samples with therapeutic proton beams.

    abstract::The design and performance of a dosimetric system for the irradiation of thin biological samples with therapeutic proton beams is reported. Protons with initial energies between 40 MeV and 250 MeV are degraded with polystyrene blocks of variable thickness in order to place the sample, an aqueous layer of 10 microm thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/3/304

    authors: Bashkirov V,Schulte RW

    更新日期:2002-02-07 00:00:00

  • Performance of isotropic light dosimetry probes based on scattering bulbs in turbid media.

    abstract::In a previous paper the calibration of an isotropic light detector in clear media was described and validated. However, in most applications the detector is used to measure light distribution in turbid (scattering) media, that is, in tissues or tissue equivalent optical phantoms. Despite its small diameter (typically ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/12/304

    authors: Marijnissen JP,Star WM

    更新日期:2002-06-21 00:00:00

  • Dielectric properties of porcine glands, gonads and body fluids.

    abstract::Dielectric properties of porcine glandular tissues and gonads (in vivo) and body fluids (in vitro) have been obtained in the frequency range of 50 MHz to 20 GHz. The experimental data were fitted to a two term Cole-Cole expression. The data presented complement the available dielectric properties of tissues in the lit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/N339

    authors: Peyman A,Gabriel C

    更新日期:2012-10-07 00:00:00

  • Evaluation of multiple-sphere head models for MEG source localization.

    abstract::Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-spher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/010

    authors: Lalancette M,Quraan M,Cheyne D

    更新日期:2011-09-07 00:00:00

  • Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

    abstract::Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7122

    authors: Zhang H,Zeng D,Lin J,Zhang H,Bian Z,Huang J,Gao Y,Zhang S,Zhang H,Feng Q,Liang Z,Chen W,Ma J

    更新日期:2017-07-07 00:00:00

  • Should image rotation be addressed during routine cone-beam CT quality assurance?

    abstract::The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1059

    authors: Ayan AS,Lin H,Yeager C,Deville C,McDonough J,Zhu TC,Anderson N,Bar Ad V,Lu HM,Both S

    更新日期:2013-02-21 00:00:00

  • Dual energy x-ray laser measurement of calcaneal bone mineral density.

    abstract::In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/305

    authors: Hakulinen MA,Saarakkala S,Töyräs J,Kröger H,Jurvelin JS

    更新日期:2003-06-21 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00