An analysis of breast motion using high-frequency, dense surface points captured by an optical sensor during radiotherapy treatment delivery.

Abstract:

:Patient motion is an important factor affecting the quality of external beam radiotherapy in breast patients. We analyse the motion of a dense set of surface points on breast patients throughout their treatment schedule to assess the magnitude and stability of motion, in particular, with respect to breast volume. We use an optical sensor to measure the surface motion of 13 breast cancer patients. Patients were divided into two cohorts dependent upon breast volume. Measurements were made during radiotherapy treatment beam delivery for an average of 12 fractions per patient (total 158 datasets). The motion of each surface point is parameterized in terms of its period, amplitude and relative phase. Inter-comparison of the motion parameters across treatment schedules and between patients is made through the creation of corresponding regions on the breast surfaces. The motion period is spatially uniform and is similar in both patient groups (mean 4 s), with the small volume cohort exhibiting greater inter-fraction period variability. The mean motion amplitude is also similar in both groups with a range between 2 mm and 4 mm and an inter-fraction variability generally less than 1 mm. There is a phase lag of up to 0.4 s across the breast, led by the sternum. Breast patient motion is reasonably stable between and during treatment fractions, with the large volume cohort exhibiting greater repeatability than the small volume one.

journal_name

Phys Med Biol

authors

Price GJ,Sharrock PJ,Marchant TE,Parkhurst JM,Burton D,Jain P,Price P,Moore CJ

doi

10.1088/0031-9155/54/21/005

subject

Has Abstract

pub_date

2009-11-07 00:00:00

pages

6515-33

issue

21

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(09)23970-4

journal_volume

54

pub_type

杂志文章
  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • Perturbation correction for alanine dosimeters in different phantom materials in high-energy photon beams.

    abstract::In modern radiotherapy the verification of complex treatments plans is often performed in inhomogeneous or even anthropomorphic phantoms. For dose verification small detectors are necessary and therefore alanine detectors are most suitable. Though the response of alanine for a wide range of clinical photon energies in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/N70

    authors: von Voigts-Rhetz P,Anton M,Vorwerk H,Zink K

    更新日期:2016-02-07 00:00:00

  • Methods for the inclusion of shallow marrow and adipose tissue in pathlength-based skeletal dosimetry.

    abstract::Distributions of linear pathlength measurements have been utilized in skeletal dosimetry of internally emitted short-range particles for over 30 years. This work reviews the methods for coupling these distributions to range-energy data. A revised methodology is presented for handling the insertion of the additional do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/9/004

    authors: Jokisch DW,Rajon DA,Patton PW,Bolch WE

    更新日期:2011-05-07 00:00:00

  • Pulsed EPR imaging: image reconstruction using selective acquisition sequences.

    abstract::Pulsed nuclear magnetic resonance imaging (NMRI) apparatus has developed very quickly. On the other hand, the development of apparatus for pulsed electron paramagnetic resonance imaging (EPRI) has been very slow. This fact is due to the extremely reduced relaxation times of the paramagnetic probes. EPR linewidths are ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/6/409

    authors: Di Giuseppe S,Placidi G,Brivati JA,Alecci M,Sotgiu A

    更新日期:1999-06-01 00:00:00

  • Film dosimetry using a smart device camera: a feasibility study for point dose measurements.

    abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8b36

    authors: Aland T,Jhala E,Kairn T,Trapp J

    更新日期:2017-10-03 00:00:00

  • A revised monitor source method for practical deadtime count loss compensation in clinical planar and SPECT studies.

    abstract::The aim of the study is to verify the fundamental assumption in the monitor source method, i.e. uniform fractional count loss across the field of view (FOV), and to introduce a revised monitor source method for SPECT deadtime correction that minimally interferes with the clinical protocol. SPECT images of non-uniform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1199

    authors: Siman W,Silosky M,Kappadath SC

    更新日期:2015-02-07 00:00:00

  • Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM.

    abstract::We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole col...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/017

    authors: Koral KF,Yendiki A,Dewaraja YK

    更新日期:2007-02-07 00:00:00

  • Theoretical modeling of yields for proton-induced reactions on natural and enriched molybdenum targets.

    abstract::Recent acute shortage of medical radioisotopes prompted investigations into alternative methods of production and the use of a cyclotron and ¹⁰⁰Mo(p,2n)(99m)Tc reaction has been considered. In this context, the production yields of (99m)Tc and various other radioactive and stable isotopes which will be created in the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/002

    authors: Celler A,Hou X,Bénard F,Ruth T

    更新日期:2011-09-07 00:00:00

  • Impact of high dose volumetric CT on PTV margin reduction in VMAT prostate radiotherapy.

    abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab050f

    authors: Cho YB,Alasti H,Kong V,Catton C,Berlin A,Chung P,Bayley A,Jaffray D

    更新日期:2019-03-14 00:00:00

  • Physical modelling of electroporation in close cell-to-cell proximity environments.

    abstract::Many applications of electroporation, especially those utilizing electrofusion and in-vivo electroporation, involve cell environments that include close cell-to-cell proximity and a wide range of target cell size. It is important to understand how this kind of environment may alter optimum electroporation electrical p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/012

    authors: Gaynor PT,Bodger PS

    更新日期:2006-06-21 00:00:00

  • Assessment of the exposure to biologically effective UV radiation using a dosimetric technique to evaluate the solar spectrum.

    abstract::A cost-effective method employing polysulphone, nalidixic acid, 8-methoxypsoralen and phenothiazine as UV dosimeters is presented for evaluating the UV spectrum. The exposure measured by each dosimeter is a function of the source spectrum and the spectral response of the material. Each material has a different spectra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/005

    authors: Parisi AV,Wong JC,Moore GI

    更新日期:1997-01-01 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer.

    abstract::The aim of this study is to investigate the feasibility of using conventional jaws to deliver inverse planned intensity-modulated radiotherapy (IMRT) plans for patients with prostate cancer. For ten patients, each had one three-dimensional conformal plan (3D plan) and seven inverse IMRT plans using direct aperture opt...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0031-9155/52/8/007

    authors: Kim Y,Verhey LJ,Xia P

    更新日期:2007-04-21 00:00:00

  • Application of an M-line-based backprojected filtration algorithm to triple-cone-beam helical CT.

    abstract::To increase the scanning speed of cone-beam CT, a scanning configuration with three pairs of x-ray sources and panel detectors was proposed. In this paper, we apply the M-line-based backprojected filtration algorithm to this scanning configuration and propose a fast implementation for this algorithm. Compared with exi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/009

    authors: Zhao Y,Zhu Y,Zhang P

    更新日期:2010-12-07 00:00:00

  • 3D prompt gamma imaging for proton beam range verification.

    abstract::We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC place...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa203

    authors: Draeger E,Mackin D,Peterson S,Chen H,Avery S,Beddar S,Polf JC

    更新日期:2018-01-30 00:00:00

  • Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife calculated with PENELOPE.

    abstract::Monte Carlo simulation with PENELOPE (version 2003) is applied to calculate Leksell Gamma Knife dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/018

    authors: Al-Dweri FM,Rojas EL,Lallena AM

    更新日期:2005-12-07 00:00:00

  • Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model.

    abstract::In multiple plan adaptive radiotherapy (ART) strategies of bladder cancer, a library of plans corresponding to different bladder volumes is created based on images acquired in early treatment sessions. Subsequently, the plan for the smallest PTV safely covering the bladder on cone-beam CT (CBCT) is selected as the pla...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3945

    authors: Chai X,van Herk M,Betgen A,Hulshof M,Bel A

    更新日期:2012-06-21 00:00:00

  • A point kernel algorithm for microbeam radiation therapy.

    abstract::Microbeam radiation therapy (MRT) is a treatment approach in radiation therapy where the treatment field is spatially fractionated into arrays of a few tens of micrometre wide planar beams of unusually high peak doses separated by low dose regions of several hundred micrometre width. In preclinical studies, this treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8d63

    authors: Debus C,Oelfke U,Bartzsch S

    更新日期:2017-10-19 00:00:00

  • Quantification of lung tumor rotation with automated landmark extraction using orthogonal cine MRI images.

    abstract::The quantification of tumor motion in sites affected by respiratory motion is of primary importance to improve treatment accuracy. To account for motion, different studies analyzed the translational component only, without focusing on the rotational component, which was quantified in a few studies on the prostate with...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7165

    authors: Paganelli C,Lee D,Greer PB,Baroni G,Riboldi M,Keall P

    更新日期:2015-09-21 00:00:00

  • The MLC tongue-and-groove effect on IMRT dose distributions.

    abstract::We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/310

    authors: Deng J,Pawlicki T,Chen Y,Li J,Jiang SB,Ma CM

    更新日期:2001-04-01 00:00:00

  • Automated prostate segmentation in whole-body MRI scans for epidemiological studies.

    abstract::The whole prostatic volume (PV) is an important indicator for benign prostate hyperplasia. Correlating the PV with other clinical parameters in a population-based prospective cohort study (SHIP-2) requires valid prostate segmentation in a large number of whole-body MRI scans. The axial proton density fast spin echo fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5899

    authors: Habes M,Schiller T,Rosenberg C,Burchardt M,Hoffmann W

    更新日期:2013-09-07 00:00:00

  • Detour factors in water and plastic phantoms and their use for range and depth scaling in electron-beam dosimetry.

    abstract::Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/7/004

    authors: Fernández-Varea JM,Andreo P,Tabata T

    更新日期:1996-07-01 00:00:00

  • A task-based quality control metric for digital mammography.

    abstract::A reader study was conducted to tune the parameters of an observer model used to predict the detectability index (dʹ ) of test objects as a task-based quality control (QC) metric for digital mammography. A simple test phantom was imaged to measure the model parameters, namely, noise power spectrum,modulation transfer ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6621

    authors: Bloomquist AK,Mainprize JG,Mawdsley GE,Yaffe MJ

    更新日期:2014-11-07 00:00:00

  • Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography.

    abstract::The incorporation of accurately aligned anatomical information as a prior to guide reconstruction and noise regularization in positron emission tomography (PET) has been suggested in many previous studies. However, the advantages of this approach can only be realized if the exact lesion outline is also available. In p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/24/009

    authors: Chan C,Fulton R,Feng DD,Meikle S

    更新日期:2009-12-21 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • Coronary CT angiography (cCTA): automated registration of coronary arterial trees from multiple phases.

    abstract::Coronary computed tomography angiography (cCTA) is a commonly used imaging modality for the evaluation of coronary artery disease. cCTA is generally reconstructed in multiple cardiac phases because different coronary arteries may be better visualized in some phases than in others due to the periodic cardiac motion. We...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4661

    authors: Hadjiiski L,Zhou C,Chan HP,Chughtai A,Agarwal P,Kuriakose J,Kazerooni E,Wei J,Patel S

    更新日期:2014-08-21 00:00:00

  • Optical studies of vaporization and stability of fluorescently labelled perfluorocarbon droplets.

    abstract::Droplets of liquid perfluorocarbon (PFC) are under study as the next generation of contrast agents for ultrasound (US). These droplets can be selectively vaporized into echogenic gas bubbles in situ by externally applied US, with numerous applications to diagnosis and therapy. However, little is known about the mechan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/21/7205

    authors: Reznik N,Seo M,Williams R,Bolewska-Pedyczak E,Lee M,Matsuura N,Gariepy J,Foster FS,Burns PN

    更新日期:2012-11-07 00:00:00

  • Factorial phase imaging: a new concept in the analysis of first-pass cardiac studies.

    abstract::A method is described which offers an alternative to conventional Fourier phase/amplitude imaging for analysing representative LV cycles obtained from first-pass cardiac studies. The method involves applying factor analysis to the data and producing functional images of the first two factor loadings after polar transf...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/10/007

    authors: Houston AS,Elliott AT,Stone DL

    更新日期:1982-10-01 00:00:00

  • Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU.

    abstract::Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/15/021

    authors: Kim KS,Ye JC

    更新日期:2011-08-07 00:00:00

  • Comparison of SAR and induced current densities in adults and children exposed to electromagnetic fields from electronic article surveillance devices.

    abstract::Electronic article surveillance (EAS) devices are widely used in most stores as anti-theft systems. In this work, the compliance with international guidelines in the human exposure to these devices is analysed by using the finite-difference time-domain (FDTD) method. Two sets of high resolution numerical phantoms of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/009

    authors: Martínez-Búrdalo M,Sanchis A,Martín A,Villar R

    更新日期:2010-02-21 00:00:00