Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

Abstract:

:In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The method is based on cine EPID images of a ball bearing marker fixed to the gantry head and determines the jaw and MLC sag in all directions relative to the reference at zero gantry angle. Analysis was performed using different field sizes and collimator angles, different linacs and different gantry rotation directions. The accuracy of the method was tested and was less than 0.02 mm. The repeatability and reproducibility of the method was 0.005 and 0.09 mm, respectively. The setup is easy and quick and the algorithm is fast and fully automatic with sub-pixel accuracy. This method is suitable to be included in the routine quality assurance of linacs to monitor the collimator system performance.

journal_name

Phys Med Biol

authors

Rowshanfarzad P,Sabet M,O'Connor DJ,Greer PB

doi

10.1088/0031-9155/57/12/N209

subject

Has Abstract

pub_date

2012-06-21 00:00:00

pages

N209-24

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

    abstract::Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/005

    authors: Floyd CE,Jaszczak RJ,Harris CC,Coleman RE

    更新日期:1984-10-01 00:00:00

  • Report of the IPSM working party on low- and medium-energy x-ray dosimetry. Institute of Physical Sciences in Medicine.

    abstract::New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the IAEA in 1987. These are not considered to possess sufficient support from other s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/8/001

    authors:

    更新日期:1991-08-01 00:00:00

  • Characterization of a preclinical PET insert in a 7 Tesla MRI scanner: beyond NEMA testing.

    abstract::This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the NEMA NU 4-2008 for small animal PET. The PET insert is made of 3 rings of 8 monolithic LYSO crystals ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba08c

    authors: Gsell W,Molinos C,Correcher C,Belderbos S,Wouters J,Junge S,Heidenreich M,Vande Velde G,Rezaei A,Nuyts J,Cawthorne C,Cleeren F,Nannan L,Deroose CM,Himmelreich U,González Martínez AJ

    更新日期:2020-06-26 00:00:00

  • Lasso logistic regression to derive workflow-specific algorithm performance requirements as demonstrated for head and neck cancer deformable image registration in adaptive radiation therapy.

    abstract::As automation in radiation oncology becomes more common, it is important to determine which algorithms are equivalent for a given workflow. Often, algorithm comparisons are performed in isolation; however, clinical context can provide valuable insight into the importance of algorithm features and error magnification i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc8

    authors: Weppler S,Schinkel C,Kirkby C,Smith W

    更新日期:2020-09-28 00:00:00

  • Characterization of cirrhosis and hepatocellular carcinoma using low-angle x-ray scattering signatures of serum.

    abstract::The diagnosis of hepatocellular carcinoma (HCC) usually occurs at late stages in the disease when there are few effective treatment options. The measurement of the concentration of tumour markers in the serum of patients is a complementary tool frequently used for the interpretation of diagnostic imaging results. It i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/17/401

    authors: Elshemey WM,Desouky OS,Mohammed MS,Elsayed AA,el-Houseini ME

    更新日期:2003-09-07 00:00:00

  • Assessment of histotripsy-induced liquefaction with diagnostic ultrasound and magnetic resonance imaging in vitro and ex vivo.

    abstract::Histotripsy is a therapeutic ultrasound modality under development to liquefy tissue mechanically via bubble clouds. Image guidance of histotripsy requires both quantification of the bubble cloud activity and accurate delineation of the treatment zone. In this study, magnetic resonance (MR) and diagnostic ultrasound i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab143f

    authors: Anthony GJ,Bollen V,Hendley S,Antic T,Sammet S,Bader KB

    更新日期:2019-05-02 00:00:00

  • Aerosol particle impaction in the conducting airways.

    abstract::Modelling of inhaled particle deposition in the lungs potentially offers data relevant to assessing hazards from toxic inhaled particles, to studying mucus clearance or lung permeability by aerosol techniques, and to achieving better utilisation of drugs administered as aerosols. Analysis of published modelling studie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/7/001

    authors: Agnew JE,Pavia D,Clarke SW

    更新日期:1984-07-01 00:00:00

  • Performance measurements of a high-spatial-resolution YAP camera.

    abstract::Physical properties of a position-sensitive camera for the analysis of biodistributions of gamma- and beta-emitting radiopharmaceuticals in small animals have been studied, in order to achieve optimal operating conditions. The camera consisted of a highly segmented yttrium-aluminate perovskite (YAP) scintillator, coup...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/n01

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Baldazzi G,Bollini D,de Notaristefani F,Mazzi U,Riondato M

    更新日期:2005-02-07 00:00:00

  • Improved procedure for neuromagnetic localisation.

    abstract::We describe an improved algorithm for localising equivalent sources of biomagnetic fields in the human brain. The algorithm is an improvement over the sphere model in that it considers two distinct surfaces: an ellipsoid, to model the region of the skull on which the sensors are placed, and a sphere as the medium in w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/017

    authors: Pistella F,Barone P,Narici L,Ocello N,Pizzella V,Romani GL

    更新日期:1987-01-01 00:00:00

  • Hybrid scatter correction applied to quantitative holmium-166 SPECT.

    abstract::Ho-166 is a combined beta-gamma emitter of which the betas can be used therapeutically. From the 81 keV gammas of Ho-166, SPECT images can be obtained, which give opportunities to guide Ho-166 therapy. Accurate reconstruction of Ho-166 images is currently hampered by photopeak-scatter in the patient, down-scatter in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/004

    authors: de Wit TC,Xiao J,Nijsen JF,van het Schip FD,Staelens SG,van Rijk PP,Beekman FJ

    更新日期:2006-10-07 00:00:00

  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images.

    abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/22/008

    authors: Yoshida H,Casalino DD,Keserci B,Coskun A,Ozturk O,Savranlar A

    更新日期:2003-11-21 00:00:00

  • Modifying proton fluence spectra to generate spread-out Bragg peaks with laser accelerated proton beams.

    abstract::Currently, energy spectra of laser accelerated proton beams are far from being monoenergetic. For their application in radiation therapy, energy selection systems using magnetic fields have been proposed to single out particles with the desired energy. These systems allow the choice of protons between a lowest and a h...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/N04

    authors: Schell S,Wilkens JJ

    更新日期:2009-10-07 00:00:00

  • First in-beam PET measurement of beta+ radioactivity induced by hard photon beams.

    abstract::In this note, we present the first experimental results of in-beam PET measurements during high energy photon phantom irradiation. An inhomogeneous phantom was irradiated with pulsed 34 MV bremsstrahlung. The measurements have been conducted with a dedicated double head positron camera. A high material contrast could ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/N01

    authors: Kluge T,Möckel D,Pawelke J,Enghardt W

    更新日期:2007-10-21 00:00:00

  • Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'.

    abstract::Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/002

    authors: Salter BJ,Sarkar V,Wang B,Shukla H,Szegedi M,Rassiah-Szegedi P

    更新日期:2011-04-07 00:00:00

  • Medical applications of synchrotron radiation.

    abstract::The medical imaging and therapeutic technologies that are based on the use of radiation are reviewed briefly, with special emphasis on the recent developments of synchrotron radiation (SR) methods. New results have been achieved in all of these areas since the last comprehensive reviews were written in this field. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/48/13/201

    authors: Suortti P,Thomlinson W

    更新日期:2003-07-07 00:00:00

  • Impact of attenuation correction strategies on the quantification of High Resolution Research Tomograph PET studies.

    abstract::In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a micro-image from m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/1/007

    authors: van Velden FH,Kloet RW,van Berckel BN,Molthoff CF,de Jong HW,Lammertsma AA,Boellaard R

    更新日期:2008-01-07 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • Reconstructing uniformly attenuated rotating slant-hole SPECT projection data using the DBH method.

    abstract::This work applies a previously developed analytical algorithm to the reconstruction problem in a rotating multi-segment slant-hole (RMSSH) SPECT system. The RMSSH collimator has greater detection efficiency than the parallel-hole collimator with comparable spatial resolution at the expense of limited common volume-of-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/13/024

    authors: Huang Q,Xu J,Tsui BM,Gullberg GT

    更新日期:2009-07-07 00:00:00

  • Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm.

    abstract::A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/312

    authors: Bloch P,Altschuler MD,Bjärngard BE,Kassaee A,McDonough J

    更新日期:2000-01-01 00:00:00

  • Segmentation and classification of thyroid follicular neoplasm using cascaded convolutional neural network.

    abstract::In this paper, we present a segmentation and classification method for thyroid follicular neoplasms based on a combination of the prior-based level set method and deep convolutional neural network. The proposed method aims to discriminate thyroid follicular adenoma (TFA) and follicular thyroid carcinoma (FTC) in ultra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc6f2

    authors: Yang B,Yan M,Yan Z,Zhu C,Xu D,Dong F

    更新日期:2020-11-02 00:00:00

  • The impact of calibration phantom errors on dual-energy digital mammography.

    abstract::Microcalcification is one of the earliest and main indicators of breast cancer. Because dual-energy digital mammography could suppress the contrast between the adipose and glandular tissues of the breast, it is considered a promising technique that will improve the detection of microcalcification. In dual-energy digit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/004

    authors: Mou X,Chen X,Sun L,Yu H,Ji Z,Zhang L

    更新日期:2008-11-21 00:00:00

  • Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography.

    abstract::The incorporation of accurately aligned anatomical information as a prior to guide reconstruction and noise regularization in positron emission tomography (PET) has been suggested in many previous studies. However, the advantages of this approach can only be realized if the exact lesion outline is also available. In p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/24/009

    authors: Chan C,Fulton R,Feng DD,Meikle S

    更新日期:2009-12-21 00:00:00

  • Performance of a multi-axis ionization chamber array in a 1.5 T magnetic field.

    abstract::At the UMC Utrecht a prototype MR-linac has been installed. The system consists of an 8 MV Elekta linear accelerator and a 1.5 T Philips MRI system. This paper investigates the performance of the IC PROFILER™, a multi-axis ionization chamber array, in a 1.5 T magnetic field. The influence of the magnetic field on the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1845

    authors: Smit K,Kok JG,Lagendijk JJ,Raaymakers BW

    更新日期:2014-04-07 00:00:00

  • Estimating cancer risk from dental cone-beam CT exposures based on skin dosimetry.

    abstract::The aim of this study was to measure entrance skin doses on patients undergoing cone-beam computed tomography (CBCT) examinations, to establish conversion factors between skin and organ doses, and to estimate cancer risk from CBCT exposures. 266 patients (age 8-83) were included, involving three imaging centres. CBCT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/14/3877

    authors: Pauwels R,Cockmartin L,Ivanauskaité D,Urbonienė A,Gavala S,Donta C,Tsiklakis K,Jacobs R,Bosmans H,Bogaerts R,Horner K,SEDENTEXCT Project Consortium.

    更新日期:2014-07-21 00:00:00

  • Imaging placental function: current technology, clinical needs, and emerging modalities.

    abstract::The function of the placenta is challenging to characterize and as a result is understudied, despite the growing awareness of the impact of the placental environment on human health and development. Medical imaging has the potential to improve our ability to screen for diseases associated with placental insufficiency,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6560/aaccd9

    authors: Wu C,Bayer CL

    更新日期:2018-07-09 00:00:00

  • Optimisation of field flatness and depth-dose for therapy electron beams.

    abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/007

    authors: Marbach JR,Almond PR

    更新日期:1981-05-01 00:00:00

  • Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study.

    abstract::The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/021

    authors: Deeley MA,Chen A,Datteri R,Noble JH,Cmelak AJ,Donnelly EF,Malcolm AW,Moretti L,Jaboin J,Niermann K,Yang ES,Yu DS,Yei F,Koyama T,Ding GX,Dawant BM

    更新日期:2011-07-21 00:00:00

  • Detour factors in water and plastic phantoms and their use for range and depth scaling in electron-beam dosimetry.

    abstract::Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/7/004

    authors: Fernández-Varea JM,Andreo P,Tabata T

    更新日期:1996-07-01 00:00:00

  • Wavelet compression in medical terahertz pulsed imaging.

    abstract::This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This mak...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/328

    authors: Handley JW,Fitzgerald AJ,Berry E,Boyle RD

    更新日期:2002-11-07 00:00:00