Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

Abstract:

:This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among them, 76 are benign, 81 are stage I and 86 are stage III malignant nodules. The cases are separated into three data sets involving: (1) all nodules, (2) benign and stage I malignant nodules, and (3) benign and stage III malignant nodules. A CADx scheme is applied to segment lung nodules depicted on computed tomography images and we initially computed 66 3D image features. Then, three machine learning models namely, a support vector machine, naïve Bayes classifier and linear discriminant analysis, are separately trained and tested by using three data sets and a leave-one-case-out cross-validation method embedded with a Relief-F feature selection algorithm. When separately using three data sets to train and test three classifiers, the average areas under receiver operating characteristic curves (AUC) are 0.94, 0.90 and 0.99, respectively. When using the classifiers trained using data sets with all nodules, average AUC values are 0.88 and 0.99 for detecting early and advanced stage nodules, respectively. AUC values computed from three classifiers trained using the same data set are consistent without statistically significant difference (p  >  0.05). This study demonstrates (1) the feasibility of applying a CADx scheme to accurately distinguish between benign and malignant lung nodules, and (2) a positive trend between CADx performance and cancer progression stage. Thus, in order to increase CADx performance in detecting subtle and early cancer, training data sets should include more diverse early stage cancer cases.

journal_name

Phys Med Biol

authors

Gong J,Liu JY,Sun XW,Zheng B,Nie SD

doi

10.1088/1361-6560/aaa610

subject

Has Abstract

pub_date

2018-02-05 00:00:00

pages

035036

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

杂志文章
  • Simultaneous optimization of RBE-weighted dose and nanometric ionization distributions in treatment planning with carbon ions.

    abstract::Inverse treatment planning in intensity modulated particle therapy (IMPT) with scanned carbon-ion beams is currently based on the optimization of RBE-weighted dose to satisfy requirements of target coverage and limited toxicity to organs-at-risk (OARs) and healthy tissues. There are many feasible IMPT plans that meet ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf400

    authors: Burigo LN,Ramos-Méndez J,Bangert M,Schulte RW,Faddegon B

    更新日期:2019-01-04 00:00:00

  • Coronary CT angiography (cCTA): automated registration of coronary arterial trees from multiple phases.

    abstract::Coronary computed tomography angiography (cCTA) is a commonly used imaging modality for the evaluation of coronary artery disease. cCTA is generally reconstructed in multiple cardiac phases because different coronary arteries may be better visualized in some phases than in others due to the periodic cardiac motion. We...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4661

    authors: Hadjiiski L,Zhou C,Chan HP,Chughtai A,Agarwal P,Kuriakose J,Kazerooni E,Wei J,Patel S

    更新日期:2014-08-21 00:00:00

  • A new approach to account for the medium-dependent effect in model-based dose calculations for kilovoltage x-rays.

    abstract::This study presents a new approach to accurately account for the medium-dependent effect in model-based dose calculations for kilovoltage (kV) x-rays. This approach is based on the hypothesis that the correction factors needed to convert dose from model-based dose calculations to absorbed dose-to-medium depend on both...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/011

    authors: Pawlowski JM,Ding GX

    更新日期:2011-07-07 00:00:00

  • On the importance of body posture and skin modelling with respect to in situ electric field strengths in magnetic field exposure scenarios.

    abstract::The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4412

    authors: Schmid G,Hirtl R

    更新日期:2016-06-21 00:00:00

  • The calibration of CT Hounsfield units for radiotherapy treatment planning.

    abstract::Computer tomographic (CT) scans are used to correct for tissue inhomogeneities in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and electron densities (or proton stopping powers for proton radiotherapy), which is the b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/1/009

    authors: Schneider U,Pedroni E,Lomax A

    更新日期:1996-01-01 00:00:00

  • Evaluation of multiple-sphere head models for MEG source localization.

    abstract::Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-spher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/010

    authors: Lalancette M,Quraan M,Cheyne D

    更新日期:2011-09-07 00:00:00

  • Optimizing 4DCBCT projection allocation to respiratory bins.

    abstract::4D cone beam computed tomography (4DCBCT) is an emerging image guidance strategy used in radiotherapy where projections acquired during a scan are sorted into respiratory bins based on the respiratory phase or displacement. 4DCBCT reduces the motion blur caused by respiratory motion but increases streaking artefacts d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5631

    authors: O'Brien RT,Kipritidis J,Shieh CC,Keall PJ

    更新日期:2014-10-07 00:00:00

  • Separating components of variation in measurement series using maximum likelihood estimation. Application to patient position data in radiotherapy.

    abstract::Maximum likelihood estimation (MLE) is presented as a statistical tool to evaluate the contribution of measurement error to any measurement series where the same quantity is measured using different independent methods. The technique was tested against artificial data sets; generated for values of underlying variation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/6019

    authors: Sage JP,Mayles WP,Mayles HM,Syndikus I

    更新日期:2014-10-21 00:00:00

  • Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction.

    abstract::Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3717

    authors: Schwemmer C,Rohkohl C,Lauritsch G,Müller K,Hornegger J

    更新日期:2013-06-07 00:00:00

  • Biological dosimetry of complex ion radiation fields.

    abstract::We report on a set of cell survival experiments performed in complex field combinations of therapeutic 12C ion beams. CHO cells were exposed to the superposition of two or three fields of 12C ions arranged in a similar way to real patient treatments. Two-dimensional survival distributions were measured and compared wi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/14/302

    authors: Krämer M,Wang JF,Weyrather W

    更新日期:2003-07-21 00:00:00

  • Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes.

    abstract::The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scinti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/21/008

    authors: Jeong MH,Choi Y,Chung YH,Song TY,Jung JH,Hong KJ,Min BJ,Choe YS,Lee KH,Kim BT

    更新日期:2004-11-07 00:00:00

  • Application of a CCD linear array camera in the quantification of tissue staining: NBT detection in ischaemic myocardium.

    abstract::A method was developed to quantify the intensity of tissue staining using a CCD (charge-coupled device) camera. Reflection spectra of NBT-stained (nitro-blue tetrazolium-stained) and unstained myocardium were recorded via fibre optics coupled to a CCD camera, connected to a microcomputer. The calculation of the intens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/007

    authors: Schröder T,Koch G,Schnabel PA,Hering JP,Bretschneider HJ,Richter J,Hellige G

    更新日期:1991-06-01 00:00:00

  • Computational dosimetry in embryos exposed to electromagnetic plane waves over the frequency range of 10 MHz-1.5 GHz.

    abstract::This paper presents calculated specific absorption rate (SAR) dosimetry in 4 and 8 week Japanese pregnant-woman models exposed to plane waves over the frequency range of 10 MHz-1.5 GHz. Two types of 2 mm spatial-resolution pregnant-woman models comprised a woman model, which is similar to the average-sized Japanese ad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/N01

    authors: Kawai H,Nagaoka T,Watanabe S,Saito K,Takahashi M,Ito K

    更新日期:2010-01-07 00:00:00

  • Postirradiation effects in alanine dosimeter probes of two different suppliers.

    abstract::The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, DW. The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for DW for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical app...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/5/006

    authors: Anton M

    更新日期:2008-03-07 00:00:00

  • LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation.

    abstract::Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector's intrinsic spatial resolution. To achieve images with better spatial resolution in a central reg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/647

    authors: Li Y,Matej S,Karp JS,Metzler SD

    更新日期:2015-01-21 00:00:00

  • Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction.

    abstract::Accurate scatter compensation in SPECT can be performed by modelling the scatter response function during the reconstruction process. This method is called reconstruction-based scatter compensation (RBSC). It has been shown that RBSC has a number of advantages over other methods of compensating for scatter, but using ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/014

    authors: Kadrmas DJ,Frey EC,Karimi SS,Tsui BM

    更新日期:1998-04-01 00:00:00

  • High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals.

    abstract::We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab8d2

    authors: Preissner M,Murrie RP,Pinar I,Werdiger F,Carnibella RP,Zosky GR,Fouras A,Dubsky S

    更新日期:2018-04-20 00:00:00

  • Comments on 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy'.

    abstract::By analyzing the radiobiological model, and the equations derived from the model, it is shown that the main results of the article 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy' by Wiklund et al (2011 Phys. Med. Biol. 56 7585-600) are valid only under the condition...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/58/18/6585

    authors: Grusell E

    更新日期:2013-09-21 00:00:00

  • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images.

    abstract::A method is presented for extraction of intra and inter fraction motion of seeds/markers within the patient from cone beam CT (CBCT) projection images. The position of the marker is determined on each projection image and fitted to a function describing the projection of a fixed point onto the imaging panel at differe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/018

    authors: Marchant TE,Amer AM,Moore CJ

    更新日期:2008-02-21 00:00:00

  • Multi-isotope SPECT imaging of the 225Ac decay chain: feasibility studies.

    abstract::Effective use of the [Formula: see text] decay chain in targeted internal radioimmunotherapy requires the retention of both [Formula: see text] and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6a99

    authors: Robertson AKH,Ramogida CF,Rodríguez-Rodríguez C,Blinder S,Kunz P,Sossi V,Schaffer P

    更新日期:2017-06-07 00:00:00

  • Investigation of the refractive index decrement of 3D printing materials for manufacturing breast phantoms for phase contrast imaging.

    abstract::3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that sof...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0670

    authors: Esposito G,Mettivier G,Bliznakova K,Bliznakov Z,Bosmans H,Bravin A,Buliev I,Di Lillo F,Ivanov D,Minutillo M,Sarno A,Vignero J,Russo P

    更新日期:2019-03-27 00:00:00

  • A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements.

    abstract::Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its hea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/22/010

    authors: ten Have AG,Gijsen FJ,Wentzel JJ,Slager CJ,Serruys PW,van der Steen AF

    更新日期:2006-11-21 00:00:00

  • Measurement of patient entrance surface dose rates for fluoroscopic x-ray units.

    abstract::Measurements of patient entrance surface dose rate provide valuable data for interpreting results from dose-area product studies on fluoroscopic x-ray equipment. Methods for measurement of entrance surface dose rate with backscatter and incident dose rate without backscatter have been investigated. Entrance surface do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/5/008

    authors: Martin CJ

    更新日期:1995-05-01 00:00:00

  • A determination by an analysis of X-ray attenuation in aluminium of the intesity distribution at its point of origin in a thick tungsten target of bremsstrahlung excited by constant potentials of 60-140 kV.

    abstract::A recently described, computer aided method of attenuation analysis has been applied to free-air chamber measurements of the attenuation by up to 30mm A1 of the exposure rate of a narrow beam of X-radiation excited at a thick W target in a Be window tube by constant potentials of 60, 80, 100, 120 and 140 kV. It has ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/2/001

    authors: Soole BW

    更新日期:1977-03-01 00:00:00

  • Numerical study of oxygen transport in a carotid bifurcation.

    abstract::This study investigates the oxygen mass transport in the region around the human carotid bifurcation, particularly addressing the effects of bifurcation geometry and pulsatile blood flow on the oxygen transport between the blood flow and artery wall tissue, coupled with the metabolic oxygen consumption and oxygen diff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/004

    authors: Tada S

    更新日期:2010-07-21 00:00:00

  • A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

    abstract::Focused ultrasound (FUS) phased arrays show promise for non-invasive brain therapy. However, the majority of them are limited to a single transmit/receive frequency and therefore lack the versatility to expose and monitor the treatment volume. Multi-frequency arrays could offer variable transmit focal sizes under a fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/24/8476

    authors: Deng L,O'Reilly MA,Jones RM,An R,Hynynen K

    更新日期:2016-12-21 00:00:00

  • Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging.

    abstract::Poly(vinyl alcohol) cryogel, PVA-C, is presented as a tissue-mimicking material, suitable for application in magnetic resonance (MR) imaging and ultrasound imaging. A 10% by weight poly(vinyl alcohol) in water solution was used to form PVA-C, which is solidified through a freeze-thaw process. The number of freeze-thaw...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/24/009

    authors: Surry KJ,Austin HJ,Fenster A,Peters TM

    更新日期:2004-12-21 00:00:00

  • Dose measurements near a non-radioactive gold seed using radiographic film.

    abstract::The dose distribution near a non-radioactive gold seed under a 6 MV photon beam was measured using radiographic film, water equivalent bolus and solid water slabs. This type of small seed is typically used as a marker in target positional verification using a portal imager for conformal prostate treatment such as inte...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/N02

    authors: Chow JC,Grigorov GN

    更新日期:2005-09-21 00:00:00

  • Thresholds for visual detection of Young's modulus contrast in simulated ultrasound image movies.

    abstract::Elasticity imaging (EI) is being developed to allow the evaluation of the mechanical properties of soft tissue, but these properties are already assessed in routine ultrasound breast examination using a method that involves the subjective interpretation of tissue motion seen in real-time B-mode image movies during pal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/301

    authors: Miller NR,Bamber JC

    更新日期:2000-08-01 00:00:00

  • Measurement of the response of Gd2O2S:Tb phosphor to 6 MV x-rays.

    abstract::The phosphor GdO2S:Tb is widely used in camera-based electronic portal imaging devices (EPIDs). There is considerable interest in the application of EPIDs to dosimetry and the verification of intensity modulated radiation therapy produced by dynamic multileaf collimation (DMLC). This paper presents direct measurement ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/317

    authors: Glendinning AG,Hunt SG,Bonnett DE

    更新日期:2001-02-01 00:00:00