Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes.

Abstract:

:The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scintillation crystal system. Flood images were obtained with a lead hole mask, and position mapping was performed by detecting hole positions in the flood image. Energy calibration was performed using the energy spectra obtained from each hole position. Flood correction was performed using a uniformity correction table containing the relative efficiency of each image element. The spatial resolution was improved about 16% after correction at the centre field of view. Resolution deterioration at the outer field of view (OFOV) was considerably ameliorated, from 6.7 mm to 3.2 mm after correction. The sensitivity at the OFOV was also increased after correction, from 0.7 cps microCi(-1) to 2.0 cps microCi(-1). The correction also improved uniformity, from 5.2% to 2.1%, and linearity, from 0.5 mm to 0 mm. The results of this study indicate that the revised correction method can be employed to considerably improve the performance of a small gamma camera using a NaI(Tl) plate-type crystal. This method also provides high spatial resolution and linearity, like array-type crystals do, while retaining the specific advantages of plate-type crystals.

journal_name

Phys Med Biol

authors

Jeong MH,Choi Y,Chung YH,Song TY,Jung JH,Hong KJ,Min BJ,Choe YS,Lee KH,Kim BT

doi

10.1088/0031-9155/49/21/008

subject

Has Abstract

pub_date

2004-11-07 00:00:00

pages

4961-70

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

49

pub_type

杂志文章
  • Construction of a biomechanical head and neck motion model as a guide to evaluation of deformable image registration.

    abstract::The use of deformable image registration methods in the context of adaptive radiotherapy leads to uncertainties in the simulation of the administered dose distributions during the treatment course. Evaluation of these methods is a prerequisite to decide if a plan adaptation will improve the individual treatment. Curre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa69b6

    authors: Teske H,Bartelheimer K,Meis J,Bendl R,Stoiber EM,Giske K

    更新日期:2017-06-21 00:00:00

  • Skin dose in chest wall radiotherapy with bolus: a Monte Carlo study.

    abstract::Monte Carlo simulations are used to investigate skin dose resulting from chest wall radiotherapy with bolus. A simple model of a female thorax is developed, which includes a 2 mm-thick skin layer. Two representative 6 MV source models are considered: a tangents source model consisting of a parallel opposed pair of med...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab95dc

    authors: Oliver PAK,Monajemi TT

    更新日期:2020-08-11 00:00:00

  • Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

    abstract::Beam tracking with scanned carbon ion radiotherapy achieves highly conformal target dose by steering carbon pencil beams to follow moving tumors using real-time magnetic deflection and range modulation. The purpose of this study was to evaluate the robustness of target dose coverage from beam tracking in light of posi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1717

    authors: Eley JG,Newhauser WD,Richter D,Lüchtenborg R,Saito N,Bert C

    更新日期:2015-02-21 00:00:00

  • Blood irradiation with accelerator produced electron beams.

    abstract::Blood and blood products are irradiated with gamma rays to reduce the risk of graft versus host disease (GVHD). A simple technique using electron beams produced by a medical linear accelerator has been studied to evaluate irradiation of blood and blood products. Variations in applied doses for a single field 20 MeV el...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/401

    authors: Butson MJ,Cheung T,Yu PK,Stokes MJ

    更新日期:2000-11-01 00:00:00

  • MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    abstract::Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab9d1

    authors: Omidvari N,Topping G,Cabello J,Paul S,Schwaiger M,Ziegler SI

    更新日期:2018-05-01 00:00:00

  • Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

    abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1325

    authors: Anizan N,Wang H,Zhou XC,Wahl RL,Frey EC

    更新日期:2015-02-07 00:00:00

  • Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams.

    abstract::The measurement of output factors (OF) for the small photon beams generated by Leksell Gamma Knife® (LGK) radiotherapy units is a challenge for the physicist due to the under or over estimation of these factors by a vast majority of the detectors commercially available. Output correction factors, introduced in the int...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/3959

    authors: Benmakhlouf H,Johansson J,Paddick I,Andreo P

    更新日期:2015-05-21 00:00:00

  • Motion-induced dose artifacts in helical tomotherapy.

    abstract::Tumor motion is a particular concern for a complex treatment modality such as helical tomotherapy, where couch position, gantry rotation and MLC leaf opening all change with time. In the present study, we have investigated the impact of tumor motion for helical tomotherapy, which could result in three distinct motion-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/004

    authors: Kim B,Chen J,Kron T,Battista J

    更新日期:2009-10-07 00:00:00

  • Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.

    abstract::The measurement of beam data for dynamic wedge dosimetry requires the integration of radiation dose at points across the radiation field during the dose delivery. The different measurement techniques required when using a linear diode array to measure beam profiles and when using ionization chambers to measure depth d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/3/005

    authors: Bidmead AM,Garton AJ,Childs PJ

    更新日期:1995-03-01 00:00:00

  • Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients.

    abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7905

    authors: Bernatowicz K,Lomax AJ,Knopf A

    更新日期:2013-11-21 00:00:00

  • Elastic modulus imaging: some exact solutions of the compressible elastography inverse problem.

    abstract::We consider several inverse problems motivated by elastography. Given the (possibly transient) displacement field measured everywhere in an isotropic, compressible, linear elastic solid, and given density rho, determine the Lamé parameters lambda and mu. We consider several special cases of this problem: (a) for mu kn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/6/003

    authors: Barbone PE,Oberai AA

    更新日期:2007-03-21 00:00:00

  • Mapping initial and general recombination in scanning proton pencil beams.

    abstract::The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k s is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min-1 in ai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8579

    authors: Christensen JB,Almhagen E,Stolarczyk L,Liszka M,Hernandez GG,Bassler N,Nørrevang O,Vestergaard A

    更新日期:2020-06-05 00:00:00

  • Effects of injected dose, BMI and scanner type on NECR and image noise in PET imaging.

    abstract::Noise equivalent count rate (NECR) and image noise are two different but related metrics that have been used to predict and assess image quality, respectively. The aim of this study is to investigate, using patient studies, the relationships between injected dose (ID), body mass index (BMI) and scanner type on NECR an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/013

    authors: Chang T,Chang G,Kohlmyer S,Clark JW,Rohren E,Mawlawi OR

    更新日期:2011-08-21 00:00:00

  • Iterative image-domain ring artifact removal in cone-beam CT.

    abstract::Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain variations using flat-panel detectors, and may lead to structured non-uniformities and deterioration of image quality. The purpose of this study is to propose a method of general ring artifact removal in CBCT images. This method is ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7017

    authors: Liang X,Zhang Z,Niu T,Yu S,Wu S,Li Z,Zhang H,Xie Y

    更新日期:2017-07-07 00:00:00

  • Comparison of recent codes of practice for high-energy photon dosimetry.

    abstract::Absorbed dose values were determined under the reference conditions in a phantom irradiated by high-energy photon beams with quality varying between 60Co gamma rays and 25 MV X-rays, using four commonly employed types of ionisation chamber. The ionisation chamber readings were converted to absorbed dose values applyin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/006

    authors: Mijnheer BJ,Wittkämper FW

    更新日期:1986-04-01 00:00:00

  • Reduced-order constrained optimization in IMRT planning.

    abstract::This paper presents a new algorithm for constrained intensity-modulated radiotherapy (IMRT) planning, made tractable by a dimensionality reduction using a set of plans obtained by fast, unconstrained optimizations. The main result is to reduce planning time by an order of magnitude, producing viable five field prostat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/007

    authors: Lu R,Radke RJ,Yang J,Happersett L,Yorke E,Jackson A

    更新日期:2008-12-07 00:00:00

  • Performance measurements of a high-spatial-resolution YAP camera.

    abstract::Physical properties of a position-sensitive camera for the analysis of biodistributions of gamma- and beta-emitting radiopharmaceuticals in small animals have been studied, in order to achieve optimal operating conditions. The camera consisted of a highly segmented yttrium-aluminate perovskite (YAP) scintillator, coup...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/n01

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Baldazzi G,Bollini D,de Notaristefani F,Mazzi U,Riondato M

    更新日期:2005-02-07 00:00:00

  • Thresholds for visual detection of Young's modulus contrast in simulated ultrasound image movies.

    abstract::Elasticity imaging (EI) is being developed to allow the evaluation of the mechanical properties of soft tissue, but these properties are already assessed in routine ultrasound breast examination using a method that involves the subjective interpretation of tissue motion seen in real-time B-mode image movies during pal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/301

    authors: Miller NR,Bamber JC

    更新日期:2000-08-01 00:00:00

  • Dynamics of the upper urinary tract: I. Peristaltic flow through a distensible tube of limited length.

    abstract::A theoretical analysis and numerical solutions are presented for viscosity-dominated flow through a uniform, highly distensible tube with a slit-shaped cross section undergoing peristalsis. At flow rates below an intrinsic upper limit to the peristaltic carrying capacity of the tube, provided that there is always at l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/7/002

    authors: Griffiths DJ

    更新日期:1987-07-01 00:00:00

  • Optimization of the accuracy of retention and washout measurements of 99mTc-Sestamibi from breast tumours using an anthropomorphic phantom.

    abstract::Quantifying the retention or washout of (99m)Tc-Sestamibi (MIBI) in breast tumours in vivo may provide a basis for predicting the chemotherapy response. The aim of this study is to investigate the variations and limitations of the different methods used to quantify these parameters. A phantom was developed that allowe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/9/013

    authors: Marshall C,Griffiths PA

    更新日期:2005-05-07 00:00:00

  • Analysis of quality control data of eight modern radiotherapy linear accelerators: the short- and long-term behaviours of the outputs and the reproducibility of quality control measurements.

    abstract::Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/14/020

    authors: Kapanen M,Tenhunen M,Hämäläinen T,Sipilä P,Parkkinen R,Järvinen H

    更新日期:2006-07-21 00:00:00

  • HeinzelCluster: accelerated reconstruction for FORE and OSEM3D.

    abstract::Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our fir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/307

    authors: Vollmar S,Michel C,Treffert JT,Newport DF,Casey M,Knöss C,Wienhard K,Liu X,Defrise M,Heiss WD

    更新日期:2002-08-07 00:00:00

  • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.

    abstract::The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast. The conversion factors currently used were obtained by computer simulation of a model breast with a composition of 50% adipose and 50% glandular tissues by ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/308

    authors: Dance DR,Skinner CL,Young KC,Beckett JR,Kotre CJ

    更新日期:2000-11-01 00:00:00

  • Ion-recombination correction for different ionization chambers in high dose rate flattening-filter-free photon beams.

    abstract::Recently, there has been an increased interest in flattening-filter-free (FFF) linear accelerators. Removal of the filter results in available dose rates up to 24 Gy min(-1) (for nominal energy 10 MV in depth of maximum dose, a source-surface distance of 100 cm and a field size of 10×10 cm2). To guarantee accurate rel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2819

    authors: Lang S,Hrbacek J,Leong A,Klöck S

    更新日期:2012-05-07 00:00:00

  • Scatter dose for wedged fields.

    abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/010

    authors: Brown LH,Siddon RL,Bjärngard BE

    更新日期:1987-10-01 00:00:00

  • Characterization of a single LSO crystal layer high resolution research tomograph.

    abstract::The purpose of this study was to determine the performance of a single lutetium oxy-orthosilicate (LSO) crystal layer High Resolution Research Tomograph (HRRT) positron emission tomography (PET) scanner. The HRRT is a high resolution PET scanner designed for human brain and small animal imaging. The scanner consists o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/4/302

    authors: Boellaard R,Buijs F,de Jong HW,Lenox M,Gremillion T,Lammertsma AA

    更新日期:2003-02-21 00:00:00

  • Linear dimension reduction of sequences of medical images: I. Optimal inner products.

    abstract::A general theory is presented for minimizing noise in linear dimension reduction of sequences of medical images when the factors and the covariance matrix and mean of the noise are given. A dimension reduction is optimal when all diagonal elements in the covariance matrix of the noise in the signal (factor) space are ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/11/010

    authors: Hermansen F,Lammertsma AA

    更新日期:1995-11-01 00:00:00

  • 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours.

    abstract::The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were impl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/1/007

    authors: Hornblower VD,Yu E,Fenster A,Battista JJ,Malthaner RA

    更新日期:2007-01-07 00:00:00

  • An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

    abstract::In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/10/010

    authors: Huang Q,Zeng GL,You J,Gullberg GT

    更新日期:2005-05-21 00:00:00

  • Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.

    abstract::Subharmonic contrast imaging promises to improve ultrasound-imaging quality by taking advantage of an increased contrast to tissue signal. However, acoustic pressures beyond the subharmonic generation threshold using common ultrasound pulses may induce significant contrast microbubble destruction. In this work, a chir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/18/005

    authors: Zhang D,Gong Y,Gong X,Liu Z,Tan K,Zheng H

    更新日期:2007-09-21 00:00:00