Measurement of the response of Gd2O2S:Tb phosphor to 6 MV x-rays.

Abstract:

:The phosphor GdO2S:Tb is widely used in camera-based electronic portal imaging devices (EPIDs). There is considerable interest in the application of EPIDs to dosimetry and the verification of intensity modulated radiation therapy produced by dynamic multileaf collimation (DMLC). This paper presents direct measurement of Gd2O2S:Tb phosphor luminescence under 6 MV x-ray irradiation from a linear accelerator using a photomultiplier tube. The luminescence following each radiation pulse (3 micros duration) was observed to decay with a dominant lifetime of 558 micros. Using a specialized electrometer, the temporal variation of the optical signal has been compared with the dose rate incident on the phosphor measured using a semiconductor diode detector. Under dose rates typical of those used in the clinic (1.2 Gy min(-1) to the phosphor), measurements at beam-start confirmed that the optical signal is linear with dose per radiation pulse. Measurements at beam termination following phosphor doses up to 4.4 Gy showed no residual signal associated with long-lived luminescence (afterglow) from the phosphor above the noise level of the optical signal (0.17% standard deviation). This measurement demonstrates that afterglow from Gd2O2S:Tb is not of significance for its application to DMLC verification. Additionally, it was confirmed that the accelerator pulse repetition frequency has no effect on the optical signal from the phosphor in the range 25-400 Hz.

journal_name

Phys Med Biol

authors

Glendinning AG,Hunt SG,Bonnett DE

doi

10.1088/0031-9155/46/2/317

subject

Has Abstract

pub_date

2001-02-01 00:00:00

pages

517-30

issue

2

eissn

0031-9155

issn

1361-6560

journal_volume

46

pub_type

杂志文章
  • Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics.

    abstract::The most advanced delivery technique for proton radiotherapy is active spot scanning. So far, predominantly static targets have been treated with active spot scanning, since mobile targets in combination with dynamic treatment delivery can lead to interplay effects, causing inhomogeneous dose distributions. One way to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/016

    authors: Knopf AC,Hong TS,Lomax A

    更新日期:2011-11-21 00:00:00

  • Semi-empirical formulation of multiple scattering for the Gaussian beam model of heavy charged particles stopping in tissue-like matter.

    abstract::Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particle...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/N01

    authors: Kanematsu N

    更新日期:2009-03-07 00:00:00

  • Estimation of torque on mechanical heart valves due to magnetic resonance imaging including an estimation of the significance of the Lenz effect using a computational model.

    abstract::Mitral and aortic valve replacement is a procedure which is common in cardiac surgery. Some of these replacement valves are mechanical and contain moving metal parts. Should the patient in whom such a valve has been implanted be involved in magnetic resonance imaging, there is a possible dangerous interaction between ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/12/320

    authors: Robertson NM,Diaz-Gomez M,Condon B

    更新日期:2000-12-01 00:00:00

  • Computational dosimetry in embryos exposed to electromagnetic plane waves over the frequency range of 10 MHz-1.5 GHz.

    abstract::This paper presents calculated specific absorption rate (SAR) dosimetry in 4 and 8 week Japanese pregnant-woman models exposed to plane waves over the frequency range of 10 MHz-1.5 GHz. Two types of 2 mm spatial-resolution pregnant-woman models comprised a woman model, which is similar to the average-sized Japanese ad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/N01

    authors: Kawai H,Nagaoka T,Watanabe S,Saito K,Takahashi M,Ito K

    更新日期:2010-01-07 00:00:00

  • The transformation method for the MIRD absorbed fraction as applied to various physiques.

    abstract::A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fracti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/4/006

    authors: Yamaguchi H,Kato Y,Shiragai A

    更新日期:1975-07-01 00:00:00

  • Lasso logistic regression to derive workflow-specific algorithm performance requirements as demonstrated for head and neck cancer deformable image registration in adaptive radiation therapy.

    abstract::As automation in radiation oncology becomes more common, it is important to determine which algorithms are equivalent for a given workflow. Often, algorithm comparisons are performed in isolation; however, clinical context can provide valuable insight into the importance of algorithm features and error magnification i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc8

    authors: Weppler S,Schinkel C,Kirkby C,Smith W

    更新日期:2020-09-28 00:00:00

  • Viscoelastic characterization of thin tissues using acoustic radiation force and model-based inversion.

    abstract::By means of the viscoelastodynamic model for a two-layer solid-fluid system and a detailed account of the locally induced acoustic radiation force, a rational analytical and computational framework is established for the viscoelastic characterization of thin tissues from high-frequency ultrasound (HFUS) measurements. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/13/009

    authors: Guzina BB,Tuleubekov K,Liu D,Ebbini ES

    更新日期:2009-07-07 00:00:00

  • A convolution-subtraction scatter correction method for 3D PET.

    abstract::3D acquisition and reconstruction in positron emission tomography (PET) produce data with improved signal-to-noise ratios compared with conventional 2D slice-oriented methods. However, the sensitivity increase is accompanied by an increase in the number of scattered photons and random coincidences detected. This paper...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/3/009

    authors: Bailey DL,Meikle SR

    更新日期:1994-03-01 00:00:00

  • Ultrasound scattering from spherical tumours.

    abstract::The interaction of biomedical ultrasound with spherical tumours in the human body is investigated using analytic methods which predict the angular distribution of the ultrasound scattered by the tumour. Both the tumour and the surrounding tissue are considered to be lossy elastic media, which support shear-wave modes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/11/001

    authors: Hinders MK,Collins JJ,Collins MM,Fang TM,Sandri GV

    更新日期:1992-11-01 00:00:00

  • An efficient strategy based on an individualized selection of registration methods. Application to the coregistration of MR and SPECT images in neuro-oncology.

    abstract::An efficient registration strategy is described that aims to help solve delicate medical imaging registration problems. It consists of running several registration methods for each dataset and selecting the best one for each specific dataset, according to an evaluation criterion. Finally, the quality of the registrati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6997

    authors: Tacchella JM,Roullot E,Lefort M,Cohen ME,Guillevin R,Petrirena G,Delattre JY,Habert MO,Yeni N,Kas A,Frouin F

    更新日期:2014-11-21 00:00:00

  • Experimental verification of numerical simulations of cryosurgery with application to computerized planning.

    abstract::As a part of an ongoing effort to develop computerized planning tools for cryosurgery, an experimental study has been conducted to verify a recently developed numerical technique for bioheat transfer simulations. Experiments were performed on gelatin solution as a phantom material, using proprietary liquid-nitrogen cr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/013

    authors: Rossi MR,Rabin Y

    更新日期:2007-08-07 00:00:00

  • Comparing the effectiveness and efficiency of various gating approaches for PBS proton therapy of pancreatic cancer using 4D-MRI datasets.

    abstract::Abdominal organ motion may lead to considerable uncertainties in pencil-beam scanning (PBS) proton therapy of pancreatic cancer. Beam gating, where irradiation only occurs in certain breathing phases in which the gating conditions are fulfilled, may be an option to reduce the interplay effect between tumor motion and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1175

    authors: Dolde K,Naumann P,Dávid C,Kachelriess M,Lomax AJ,Weber DC,Saito N,Burigo LN,Pfaffenberger A,Zhang Y

    更新日期:2019-04-10 00:00:00

  • Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources.

    abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc708

    authors: Schwarz BC,Godwin WJ,Wayson MB,Dewji SA,Jokisch DW,Lee C,Bolch WE

    更新日期:2020-11-03 00:00:00

  • Evaluation of a shock wave induced cavitation activity both in vitro and in vivo.

    abstract::This study evaluated the cavitation activity induced by shock wave (SW) pulses, both in vitro and in vivo, based on the area measurements of echogenic regions observed in B-mode ultrasound images. Residual cavitation bubble clouds induced by SW pulses were detected as echogenic regions in B-mode images. The temporal e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/19/014

    authors: Tu J,Matula TJ,Bailey MR,Crum LA

    更新日期:2007-10-07 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • Estimation of the absorption coefficients of two-layered media by a simple method using spatially and time-resolved reflectances.

    abstract::Our newly developed method using spatially and time-resolved reflectances can easily estimate the absorption coefficients of each layer in a two-layered medium if the thickness of the upper layer and the reduced scattering coefficients of the two layers are known a priori. We experimentally validated this method using...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/16/014

    authors: Shimada M,Sato C,Hoshi Y,Yamada Y

    更新日期:2009-08-21 00:00:00

  • Slice NEQ and system DQE to assess CT imaging performance.

    abstract::The standard Fourier metrics used for assessing image quality in computed tomography (CT) use a planar (2D) formulation of the noise equivalent quanta (NEQ) without a specific concept to manage the influence of longitudinal resolution variations, thus create a bias in the comparison of image quality for different reco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab807a

    authors: Monnin P,Viry A,Verdun FR,Racine D

    更新日期:2020-06-09 00:00:00

  • Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

    abstract::The purpose of this work was to create a computational platform for studying motion in intensity modulated radiotherapy (IMRT). Specifically, the non-uniform rational B-spline (NURB) cardiac and torso (NCAT) phantom was modified for use in a four-dimensional Monte Carlo (4D-MC) simulation system to investigate the eff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/5/014

    authors: McGurk R,Seco J,Riboldi M,Wolfgang J,Segars P,Paganetti H

    更新日期:2010-03-07 00:00:00

  • A static beam delivery device for fast scanning proton arc-therapy.

    abstract::Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called "arcs"). This technique can potentially ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe02b

    authors: Nesteruk KP,Bolsi A,Lomax AJ,Meer D,van de Water S,Schippers JM

    更新日期:2021-01-26 00:00:00

  • Ion concentration and haematocrit as determinants of impedance in an erythrocyte suspension model of renal medullary tissue.

    abstract::In order to analyse the respective roles of ion concentration and fractional volume of the interstitial compartment as determinants of the impedance, Z, of renal medullary tissue, a model was needed in which both these factors could be varied independently. An array of blood cell suspensions ions in saline (different ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/11/011

    authors: Niewiadomski W,Sadowski J,Badzyńska B,Rasmussen SN

    更新日期:1990-11-01 00:00:00

  • Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system.

    abstract::The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measureme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/N1

    authors: Yamamoto S,Watabe T,Watabe H,Aoki M,Sugiyama E,Imaizumi M,Kanai Y,Shimosegawa E,Hatazawa J

    更新日期:2012-01-21 00:00:00

  • In vivo and in vitro dielectric properties of feline tissues at low radiofrequencies.

    abstract::The dielectric constant and conductivity of muscle, liver, spleen and kidney of cats in vivo and in situ immediately following the animal's death were measured at frequencies from 10 kHz to 100 MHz. A novel multi-ring capacitive sensor and a computer-controlled automatic network analyser (ANA) were employed. The resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/007

    authors: Surowiec A,Stuchly SS,Keaney M,Swarup A

    更新日期:1986-08-01 00:00:00

  • Image quality improvements of electronic portal imaging devices by multi-level gain calibration and temperature correction.

    abstract::Amorphous silicon (aSi:H) flat panel detectors are prevalent in radiotherapy for megavoltage imaging tasks. Any clinical and dosimetrical application requires a well-defined dose response of the system to achieve meaningful results. Due to radiation damages, panels deteriorate and the linearity of pixel response to do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6429

    authors: Huber S,Mooslechner M,Mitterlechner B,Weichenberger H,Serpa M,Sedlmayer F,Deutschmann H

    更新日期:2013-09-21 00:00:00

  • Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

    abstract::Beam tracking with scanned carbon ion radiotherapy achieves highly conformal target dose by steering carbon pencil beams to follow moving tumors using real-time magnetic deflection and range modulation. The purpose of this study was to evaluate the robustness of target dose coverage from beam tracking in light of posi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1717

    authors: Eley JG,Newhauser WD,Richter D,Lüchtenborg R,Saito N,Bert C

    更新日期:2015-02-21 00:00:00

  • Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy.

    abstract::Intensity modulated proton radiotherapy (IMPT) can reduce the dose to critical structures by optimizing the distribution and intensity of individual pencil beams. The IMPT can be delivered by dynamically scanning a pencil beam with variable intensity and energy across the tumor target volume. The lateral penumbra of a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/6/016

    authors: Safai S,Bortfeld T,Engelsman M

    更新日期:2008-03-21 00:00:00

  • Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU.

    abstract::Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/15/021

    authors: Kim KS,Ye JC

    更新日期:2011-08-07 00:00:00

  • Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner.

    abstract::Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/N35

    authors: Poon JK,Dahlbom ML,Casey ME,Qi J,Cherry SR,Badawi RD

    更新日期:2015-02-07 00:00:00

  • Ionization chamber correction factors for MR-linacs.

    abstract::Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to system...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac4f2

    authors: Pojtinger S,Dohm OS,Kapsch RP,Thorwarth D

    更新日期:2018-06-07 00:00:00

  • Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization.

    abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2838

    authors: Gao H

    更新日期:2016-04-07 00:00:00

  • Analysis of RF exposure in the head tissues of children and adults.

    abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/019

    authors: Wiart J,Hadjem A,Wong MF,Bloch I

    更新日期:2008-07-07 00:00:00