Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy.

Abstract:

:Intensity modulated proton radiotherapy (IMPT) can reduce the dose to critical structures by optimizing the distribution and intensity of individual pencil beams. The IMPT can be delivered by dynamically scanning a pencil beam with variable intensity and energy across the tumor target volume. The lateral penumbra of an uncollimated pencil beam is compromised, however, by the scattering in air between the vacuum window and the patient, and by the initial beam size. In this study, we compare the transversal penumbra of a pencil beam to the one of a collimated Gaussian broad divergent beam, such as the one produced by the double scattering system, for different range compensator thicknesses, collimator-to-surface distances (CSD), proton range and pencil beam sizes (sigma0). The effect of vacuum and helium in the nozzle on the pencil beam lateral profile further downstream is also investigated. The lateral spatial intensity distribution for the collimated Gaussian broad divergent proton beam is modeled using the generalized Fermi-Eyges theory. The model is validated with measurements of the lateral profile in water at different depths for two different ranges (7.7 cm and 22.1 cm, respectively). Nearly 2500 treatment fields are analyzed to establish typical clinical beam configurations, such as the range compensator thicknesses, CSD and range, which we use to predict the 80%-20% lateral penumbra. The penumbra of the collimated broad divergent beam is calculated for fixed source-to-surface distance (SSD) of 220 cm and source size of 2.5 cm (sigma). The results show that the model predicts the penumbra at different water depths with accuracy better than 0.2 mm. At depths larger than 7.6 cm (minimum range of the clinical fields analyzed), the accuracy is better than 3%. The treatment fields feature the following average configuration: the range compensator thickness of 6.5+/-2.8 cm (max 19.4 cm), CSD 11.9+/-3.8 cm (max 29.4 cm) and range of 16.0+/-6.1 cm. The penumbra of a pencil beam at shallow depth is in general larger (i.e., worse) than the penumbra of a collimated beam, but better at larger depths. The depth at which the two penumbras are identical exhibits only a small dependence on the proton range, but is strongly affected by the collimator-to-surface distance. For CSD 10 cm, range compensator thickness 6 cm, SSD 220 cm and source size 2.5 cm, this depth is 11.5 cm for a 5 mm pencil beam, and 9.1 cm for a 3 mm pencil beam. For most of the clinical sites considered, assuming the beam configurations of this study, the pencil beam penumbra is larger (i.e., worse). By moving the vacuum window downstream or by replacing air with helium in the gantry nozzle, the dosimetrical benefit of scanning would be drastically improved, especially for small sigma0 (5 mm or less).

journal_name

Phys Med Biol

authors

Safai S,Bortfeld T,Engelsman M

doi

10.1088/0031-9155/53/6/016

subject

Has Abstract

pub_date

2008-03-21 00:00:00

pages

1729-50

issue

6

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(08)63117-6

journal_volume

53

pub_type

杂志文章
  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • Optimization and performance study of a proton CT system for pre-clinical small animal imaging.

    abstract::Proton computed tomography (pCT) promises to reduce or even eliminate range uncertainties inherent in the conversion of Hounsfield units into relative stopping power (RSP) for proton therapy treatment planning. This is of particular interest for proton irradiation studies in animal models due to the high precision req...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8afc

    authors: Meyer S,Bortfeldt J,Lämmer P,Englbrecht FS,Pinto M,Schnürle K,Würl M,Parodi K

    更新日期:2020-08-13 00:00:00

  • A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material.

    abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/23/004

    authors: Ducros N,Hervé L,Da Silva A,Dinten JM,Peyrin F

    更新日期:2009-12-07 00:00:00

  • A theoretical model for respiratory motion artifacts in free-breathing CT scans.

    abstract::Successful radiotherapy treatment depends heavily upon the accuracy of patient geometry captured during treatment simulation using computed tomography (CT) scans. Radiotherapy patients are often scanned under free breathing, and respiratory motion can cause severe artifacts in CT scans, including shortening, elongatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/3/018

    authors: Lewis JH,Jiang SB

    更新日期:2009-02-07 00:00:00

  • Broadband ultrasound attenuation imaging: algorithm development and clinical assessment of a region growing technique.

    abstract::This paper presents a computerized method for the selection of an irregular region of interest (ROI) in broadband ultrasound attenuation (BUA) images. A region growing algorithm searches an initial region in the posterior part of the calcaneus until the pixel with the lowest attenuation value is found; this is the sta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/2/310

    authors: Damilakis J,Stratakis J,Perisinakis K,Gourtsoyiannis N

    更新日期:2002-01-21 00:00:00

  • Monitoring of airborne contamination during the handling of technetium-99m and radioiodine.

    abstract::Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99Tcm can be safely handled in environments without direct exhaust of the ventilated air but that 125I and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/6/005

    authors: Eadie AS,Horton PW,Hilditch TE

    更新日期:1980-11-01 00:00:00

  • Analysis of RF exposure in the head tissues of children and adults.

    abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/019

    authors: Wiart J,Hadjem A,Wong MF,Bloch I

    更新日期:2008-07-07 00:00:00

  • Modelling infrared temperature measurements: implications for laser irradiation and cryogen cooling studies.

    abstract::The use of thermographic techniques has increased as infrared detector technology has evolved and improved. For laser-tissue interactions, thermal cameras have been used to monitor the thermal response of tissue to pulsed and continuous wave irradiation. It is important to note that the temperature indicated by the th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/319

    authors: Choi B,Pearce JA,Welch AJ

    更新日期:2000-02-01 00:00:00

  • High spatial resolution quantitative MR images: an experimental study of dedicated surface coils.

    abstract::Measuring spin-spin relaxation times (T2) by quantitative MR imaging represents a potentially efficient tool to evaluate the physicochemical properties of various media. However, noise in MR images is responsible for uncertainties in the determination of T2 relaxation times, which limits the accuracy of parametric tis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/011

    authors: Gensanne D,Josse G,Lagarde JM,Vincensini D

    更新日期:2006-06-07 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • Beam characterisation of the 1.5 T MRI-linac.

    abstract::As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab566

    authors: Woodings SJ,Bluemink JJ,de Vries JHW,Niatsetski Y,van Veelen B,Schillings J,Kok JGM,Wolthaus JWH,Hackett SL,van Asselen B,van Zijp HM,Pencea S,Roberts DA,Lagendijk JJW,Raaymakers BW

    更新日期:2018-04-19 00:00:00

  • Optimisation of field flatness and depth-dose for therapy electron beams.

    abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/007

    authors: Marbach JR,Almond PR

    更新日期:1981-05-01 00:00:00

  • A determination by an analysis of X-ray attenuation in aluminium of the intesity distribution at its point of origin in a thick tungsten target of bremsstrahlung excited by constant potentials of 60-140 kV.

    abstract::A recently described, computer aided method of attenuation analysis has been applied to free-air chamber measurements of the attenuation by up to 30mm A1 of the exposure rate of a narrow beam of X-radiation excited at a thick W target in a Be window tube by constant potentials of 60, 80, 100, 120 and 140 kV. It has ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/2/001

    authors: Soole BW

    更新日期:1977-03-01 00:00:00

  • Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient.

    abstract::Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/807

    authors: Zhang R,Howell RM,Giebeler A,Taddei PJ,Mahajan A,Newhauser WD

    更新日期:2013-02-21 00:00:00

  • Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width.

    abstract::The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been develo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/019

    authors: Poppe B,Djouguela A,Blechschmidt A,Willborn K,Rühmann A,Harder D

    更新日期:2007-05-21 00:00:00

  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images.

    abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/22/008

    authors: Yoshida H,Casalino DD,Keserci B,Coskun A,Ozturk O,Savranlar A

    更新日期:2003-11-21 00:00:00

  • A novel approach with dual-sampling convolutional neural network for ultrasound image classification of breast tumors.

    abstract::Breast cancer is one of the leading causes of female cancer deaths. Early diagnosis with prophylactic may improve the patients' prognosis. So far ultrasound (US) imaging is a popular method in breast cancer diagnosis. However, its accuracy is bounded to traditional handcrafted feature methods and expertise. A novel me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5c7

    authors: Xie J,Song X,Zhang W,Dong Q,Wang Y,Li F,Wan C

    更新日期:2020-10-29 00:00:00

  • Exact analytic reconstruction in x-ray fluorescence CT and approximated versions.

    abstract::X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Rivière (2004 Phys. Med. Biol. 49 2391-405) presented an appr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/007

    authors: Miqueles EX,De Pierro AR

    更新日期:2010-02-21 00:00:00

  • Effective energy resolution and scatter rejection in nuclear medicine.

    abstract::All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/1/008

    authors: Wirth V

    更新日期:1989-01-01 00:00:00

  • MR-based keyhole SPECT for small animal imaging.

    abstract::The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/010

    authors: Lee KS,Roeck WW,Gullberg GT,Nalcioglu O

    更新日期:2011-02-07 00:00:00

  • Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures.

    abstract::Our goal was to develop a method for generating high-resolution three-dimensional pulmonary compliance images in rodents from computed tomography (CT) images acquired at a series of constant pressures in ventilated animals. One rat and one mouse were used to demonstrate this technique. A pre-clinical GE flat panel CT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/003

    authors: Guerrero T,Castillo R,Sanders K,Price R,Komaki R,Cody D

    更新日期:2006-03-07 00:00:00

  • Learning image based surrogate relevance criterion for atlas selection in segmentation.

    abstract::Picking geometrically relevant atlases from the whole training set is crucial to multi-atlas based image segmentation, especially with extensive data of heterogeneous quality in the Big Data era. Unfortunately, there is very limited understanding of how currently used image similarity criteria reveal geometric relevan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4223

    authors: Zhao T,Ruan D

    更新日期:2016-06-07 00:00:00

  • Dosimetric characterization of a new miniature multileaf collimator.

    abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/12/402

    authors: Hartmann GH,Föhlisch F

    更新日期:2002-06-21 00:00:00

  • Optical-thermal characterization of cutaneous transilluminators.

    abstract::In recent years, there has been an increase in the popularity of light-emitting diode (LED)-based, battery-powered transilluminators (BPTs) for facilitating transdermal vascular access in adults and neonates. BPTs are believed to have lower potential for inducing skin burns than prior devices based on high-power broad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/22/008

    authors: Pfefer TJ,Mehrabi A,James R,Landry R,Weininger S,Chang I,Kaufman D,Miller S

    更新日期:2009-11-21 00:00:00

  • Comparative behaviour of the dynamically penalized likelihood algorithm in inverse radiation therapy planning.

    abstract::This paper presents a description of tests carried out to compare the behaviour of five algorithms in inverse radiation therapy planning: (1) The Dynamically Penalized Likelihood (DPL), an algorithm based on statistical estimation theory; (2) an accelerated version of the same algorithm: (3) a new fast adaptive simula...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/10/309

    authors: Llacer J,Solberg TD,Promberger C

    更新日期:2001-10-01 00:00:00

  • A proposal concerning the absorbed dose conversion factor.

    abstract::New definitions of the absorbed dose conversion factors Clambda and CE are proposed. The absorbed dose in water is given by the product of absorbed dose conversion factor, exposure calibration factor, ionisation chamber reading, cap displacement correction factor and perturbation correction factor. At exposure calibra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/2/003

    authors: Shiragai A

    更新日期:1978-03-01 00:00:00

  • Respiratory liver motion estimation and its effect on scanned proton beam therapy.

    abstract::Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1779

    authors: Zhang Y,Boye D,Tanner C,Lomax AJ,Knopf A

    更新日期:2012-04-07 00:00:00

  • Continuous bed motion on clinical scanner: design, data correction, and reconstruction.

    abstract::With the addition of variable bed speed capabilities, continuous bed motion (CBM) becomes an acquisition generalization for axial sensitivity modeling and therefore a flexible tool in axial local image quality adjustment. In this paper, we describe the principles behind CBM mode planning and its influence on image rec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/6153

    authors: Panin VY,Smith AM,Hu J,Kehren F,Casey ME

    更新日期:2014-10-21 00:00:00

  • Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography.

    abstract::In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fcd

    authors: Tanguay J,Lalonde R,Bjarnason TA,Yang CJ

    更新日期:2019-10-23 00:00:00

  • Iterative volume morphing and learning for mobile tumor based on 4DCT.

    abstract::During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa56b2

    authors: Mao S,Wu H,Sandison G,Fang S

    更新日期:2017-02-21 00:00:00