Iterative volume morphing and learning for mobile tumor based on 4DCT.

Abstract:

:During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new iterative morphing algorithm to predict the real-time 3D tumor volume based on time-resolved computed tomography (4DCT) acquired before treatment. An offline iterative learning process has been designed to derive a target volumetric deformation function from one breathing phase to another. Real-time volumetric prediction is performed to derive the target 3D volume during treatment delivery. The proposed iterative deformable approach for tumor volume morphing and prediction based on 4DCT is innovative because it makes three major contributions: (1) a novel approach to landmark selection on 3D tumor surfaces using a minimum bounding box; (2) an iterative morphing algorithm to generate the 3D tumor volume using mapped landmarks; and (3) an online tumor volume prediction strategy based on previously trained deformation functions utilizing 4DCT. The experimental performance showed that the maximum morphing deviations are 0.27% and 1.25% for original patient data and artificially generated data, which is promising. This newly developed algorithm and implementation will have important applications for treatment planning, dose calculation and treatment validation in cancer radiation treatment.

journal_name

Phys Med Biol

authors

Mao S,Wu H,Sandison G,Fang S

doi

10.1088/1361-6560/aa56b2

subject

Has Abstract

pub_date

2017-02-21 00:00:00

pages

1501-1517

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • Monte Carlo calculations of the energy response of lithium dosemeters to high energy electrons (less than 30 MeV).

    abstract::Monte Carlo calculations of the energy response of LiF dosemeters have been carried out to help resolve the discrepancy between the measurements of Holt, Edelstein and Clark (1975) and those of Paliwal and Almond (1975) and others. It is concluded that the assumptions used by Holt et al. are largely responsible. They ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/003

    authors: O'Brien K

    更新日期:1977-09-01 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

    abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/003

    authors: Trapp JV,Partridge M,Hansen VN,Childs P,Bedford J,Warrington AP,Leach MO,Webb S

    更新日期:2004-05-07 00:00:00

  • Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information.

    abstract::A method using both patient geometric and dosimetric information was proposed to predict dose-volume histograms (DVHs) of organs at risk (OARs) for a nasopharyngeal cancer (NPC) intensity-modulated radiation therapy (IMRT) plan. A total of 106 nine-field IMRT NPC plans were used in this study. Twenty-six plans were ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab50eb

    authors: Jiao SX,Chen LX,Zhu JH,Wang ML,Liu XW

    更新日期:2019-12-05 00:00:00

  • Magnetic separation of iron oxide nanoparticles to improve their application for magnetic particle imaging.

    abstract::Magnetic Particle Imaging (MPI) is a promising medical imaging technique for visualizing the three-dimensional distribution of tracer materials, specifically iron oxide nanoparticles (IONP). The optimization of magnetic nanoparticles (MNP) plays an essential role to improve the image resolution and sensitivity of imag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abcd19

    authors: Arsalani S,Loewa N,Kosch O,Radon P,Baffa O,Wiekhorst F

    更新日期:2020-11-23 00:00:00

  • The calibration of CT Hounsfield units for radiotherapy treatment planning.

    abstract::Computer tomographic (CT) scans are used to correct for tissue inhomogeneities in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and electron densities (or proton stopping powers for proton radiotherapy), which is the b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/1/009

    authors: Schneider U,Pedroni E,Lomax A

    更新日期:1996-01-01 00:00:00

  • Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung.

    abstract::Cone-beam computed tomography (CBCT) has rapidly become a clinically useful imaging modality for image-guided radiation therapy. Unfortunately, CBCT images of the thorax are susceptible to artefacts due to scattered photons, beam hardening, lag in data acquisition, and respiratory motion during a slow scan. These limi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/4157

    authors: Disher B,Hajdok G,Wang A,Craig J,Gaede S,Battista JJ

    更新日期:2013-06-21 00:00:00

  • Comparative behaviour of the dynamically penalized likelihood algorithm in inverse radiation therapy planning.

    abstract::This paper presents a description of tests carried out to compare the behaviour of five algorithms in inverse radiation therapy planning: (1) The Dynamically Penalized Likelihood (DPL), an algorithm based on statistical estimation theory; (2) an accelerated version of the same algorithm: (3) a new fast adaptive simula...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/10/309

    authors: Llacer J,Solberg TD,Promberger C

    更新日期:2001-10-01 00:00:00

  • Multi-layer imager design for mega-voltage spectral imaging.

    abstract::The architecture of multi-layer imagers (MLIs) can be exploited to provide megavoltage spectral imaging (MVSPI) for specific imaging tasks. In the current work, we investigated bone suppression and gold fiducial contrast enhancement as two clinical tasks which could be improved with spectral imaging. A method based on...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabe21

    authors: Myronakis M,Hu YH,Fueglistaller R,Wang A,Baturin P,Huber P,Morf D,Star-Lack J,Berbeco R

    更新日期:2018-05-10 00:00:00

  • Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers.

    abstract::Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/316

    authors: Spezi E,Lewis DG,Smith CW

    更新日期:2001-11-01 00:00:00

  • Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study.

    abstract::Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/011

    authors: Beekman FJ,Kamphuis C,Frey EC

    更新日期:1997-08-01 00:00:00

  • A thin target approach for portal imaging in medical accelerators.

    abstract::A new thin-target method (patent pending) is described for portal imaging with low-energy (tens of keV) photons from a medical linear accelerator operating in a special mode. Low-energy photons are usually produced in the accelerator target, but are absorbed by the target and flattening filter, both made of medium- or...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/016

    authors: Tsechanski A,Bielajew AF,Faermann S,Krutman Y

    更新日期:1998-08-01 00:00:00

  • Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams.

    abstract::The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa70cf

    authors: Moignier C,Tromson D,de Marzi L,Marsolat F,García Hernández JC,Agelou M,Pomorski M,Woo R,Bourbotte JM,Moignau F,Lazaro D,Mazal A

    更新日期:2017-07-07 00:00:00

  • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

    abstract::Developments in positron emission tomography (PET) technology have resulted in systems with finer detector elements designed to further improve spatial resolution. However, there is a limit to what extent reducing detector element size will improve spatial resolution in PET. The spatial resolution of PET imaging is li...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/3/019

    authors: Levin CS,Hoffman EJ

    更新日期:1999-03-01 00:00:00

  • Large blood vessel cooling in heated tissues: a numerical study.

    abstract::Large blood vessels can produce steep temperature gradients in heated tissues leading to inadequate tissue temperatures during hyperthermia. This paper utilizes a finite difference scheme to solve the basic equations of heat transfer and fluid flow to model blood vessel cooling. Unlike previous formulations, heat tran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/4/001

    authors: Kolios MC,Sherar MD,Hunt JW

    更新日期:1995-04-01 00:00:00

  • Extended three-compartment model for the transport and distribution of Hippuran.

    abstract::The distribution and transport of Hippuran is discussed. The activity leaving both kidneys has been calculated and compared with the bladder activity. It is shown that the Impulse Response Function of the ureter and bladder may be obtained by deconvolution, and data are presented relating to studies on one patient. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/2/002

    authors: Knesaurek K,Spaventi S

    更新日期:1981-03-01 00:00:00

  • Calculation of absorbed dose distributions from dynamic wedges.

    abstract::In radiotherapy with photon beams, the use of dynamic wedges, which are obtained by the movement of one of the jaws, offers an increasing flexibility relative to the traditional use of metal wedges. But it is a disadvantage for the measurement of absorbed dose distributions, because the absorbed dose at each measureme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/6/009

    authors: Storchi P,Woudstra E,Verlinde P,Johansson KA,Samuelsson A

    更新日期:1998-06-01 00:00:00

  • The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries.

    abstract::This study looks at blood flow in four different human right coronary arteries (RCAs), which have been reconstructed from bi-plane angiograms. A generalized power-law model of blood viscosity is used to study the blood flow at a particular point in the cardiac cycle. Large differences are found in the wall shear stres...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/9/013

    authors: Johnston BM,Johnston PR

    更新日期:2007-05-07 00:00:00

  • The noise power spectrum of CT images.

    abstract::An expression for the noise power spectrum of images reconstructed by the discrete filtered backprojection algorithm has been derived. The formulation explicitly includes sampling within the projections, angular sampling, and the two-dimensional sampling implicit in the discrete representation of the image. The effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/5/003

    authors: Kijewski MF,Judy PF

    更新日期:1987-05-01 00:00:00

  • Factorial phase imaging: a new concept in the analysis of first-pass cardiac studies.

    abstract::A method is described which offers an alternative to conventional Fourier phase/amplitude imaging for analysing representative LV cycles obtained from first-pass cardiac studies. The method involves applying factor analysis to the data and producing functional images of the first two factor loadings after polar transf...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/10/007

    authors: Houston AS,Elliott AT,Stone DL

    更新日期:1982-10-01 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • Algorithm and performance of a clinical IMRT beam-angle optimization system.

    abstract::This paper describes the algorithm and examines the performance of an intensity-modulated radiation therapy (IMRT) beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/19/007

    authors: Djajaputra D,Wu Q,Wu Y,Mohan R

    更新日期:2003-10-07 00:00:00

  • A comparison of 60 Hz uniform magnetic and electric induction in the human body.

    abstract::High-resolution computations of induced fields are used to assess equivalent source levels for human exposure to uniform low-frequency electric and magnetic fields. These results pertain to 60 Hz foot-to-head electric excitation of the body in three positions with respect to a ground plane, and to magnetic excitation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/001

    authors: Dawson TW,Caputa K,Stuchly MA

    更新日期:1997-12-01 00:00:00

  • High intensity focused ultrasound for the treatment of rat tumours.

    abstract::Discrete implanted liver tumours in the rat have been exposed to arrays of 1.7 MHz ultrasound lesions. Focal peak intensities in the range 1.4-3.5 k Wcm-2 were used for an exposure time of 10 s. It has been demonstrated that where the whole tumour volume was exposed to the focused ultrasound beam, no evidence of tumou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/11/009

    authors: ter Haar G,Rivens I,Chen L,Riddler S

    更新日期:1991-11-01 00:00:00

  • Reply to comment on 'origins of the changing detector response in small megavoltage photon radiation fields'.

    abstract::Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Furt...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aae0e4

    authors: Fenwick JD,Georgiou G,Rowbottom CG,Underwood TSA,Kumar S

    更新日期:2018-10-03 00:00:00

  • Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors.

    abstract::Modern Monte Carlo codes allow for the calculation of ion chamber specific beam quality correction factors k(Q), which are needed for dosimetry in radiotherapy. While statistical (type A) uncertainties of the calculated data can be minimized sufficiently, the influence of systematic (type B) uncertainties is mostly un...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/16/S04

    authors: Wulff J,Heverhagen JT,Zink K,Kawrakow I

    更新日期:2010-08-21 00:00:00

  • Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence.

    abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/022

    authors: Taylor ML,Franich RD,Johnston PN,Millar RM,Trapp JV

    更新日期:2007-07-07 00:00:00

  • Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.

    abstract::In the IAEA-AAPM dosimetry formalism, detector measurements in general nonstandard conditions are corrected using the factor k(f(clin),f(msr))(Q(clin),Q(msr)). This factor needs to be evaluated on a case-by-case basis which is difficult to accomplish in practice. The present paper aims to provide a method that allows ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4973

    authors: Kamio Y,Bouchard H

    更新日期:2014-09-07 00:00:00

  • Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm.

    abstract::A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/312

    authors: Bloch P,Altschuler MD,Bjärngard BE,Kassaee A,McDonough J

    更新日期:2000-01-01 00:00:00

  • Normalized mean glandular dose computation from mammography using GATE: a validation study.

    abstract::Mean glandular dose (MGD) is the figure of merit to assess breast dose after a mammographic acquisition. The use of normalized MGD obtained from Monte Carlo computations with measured incident air kerma determines the MGD delivered to patients. The Geant4 Application for Tomographic Emission (GATE) toolkit is a modern...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/7/2247

    authors: Myronakis ME,Zvelebil M,Darambara DG

    更新日期:2013-04-07 00:00:00