Abstract:
:With the addition of variable bed speed capabilities, continuous bed motion (CBM) becomes an acquisition generalization for axial sensitivity modeling and therefore a flexible tool in axial local image quality adjustment. In this paper, we describe the principles behind CBM mode planning and its influence on image reconstruction. The data correction method underwent the most changes compared to the commonly used step and shoot (S&S) mode. The CBM normalization array accommodates for activity decay, dead time correction, and the fact that various detector pairs acquire the same data for different durations. The normalization array is computed by simulating the movement of an object through the scanner, assisted by the monitoring of basic scanner acquisition parameters such as the singles rate. The sensitivity, which is the number of counts acquired per image plane, is an intrinsic part of normalization computing. Basic equations to estimate acquisition time at matched sensitivity between single speed CBM and S&S mode are presented. The CBM feature was implemented on a Siemens clinical scanner and initial studies of phantoms and patients are presented. The equivalence of single speed CBM and S&S image quality is demonstrated.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Panin VY,Smith AM,Hu J,Kehren F,Casey MEdoi
10.1088/0031-9155/59/20/6153subject
Has Abstractpub_date
2014-10-21 00:00:00pages
6153-74issue
20eissn
0031-9155issn
1361-6560journal_volume
59pub_type
杂志文章abstract::Remission spectroscopy in living tissues can only be performed because scattering processes induce a pronounced amount of backscattered light. New types of scattering chambers were constructed in order to investigate the angular distribution of light intensities caused by scattering events typical for living tissues. ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/34/12/012
更新日期:1989-12-01 00:00:00
abstract::Periacetabular osteotomy (PAO) is a joint preservation procedure for developmental dysplasia of the hip. Such a procedure requires osteotomy of the medial wall of the acetabulum, which may cause the narrow of the bony birth canal and increase the risk of complications during the childbirth process in the future. Using...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abcb22
更新日期:2021-01-22 00:00:00
abstract::The accurate determination of mean ionization potential (I m) has the potential to reduce range uncertainty based margins and therefore allow for more focal treatments in proton radiotherapy. Many methods have been proposed to reduce uncertainty in I m and stopping power ratios (SPR), each with varying degrees of accu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa8d9e
更新日期:2017-10-27 00:00:00
abstract::Quantification of nuclear medicine image data is a prerequisite for personalized absorbed dose calculations and quantitative biodistribution studies. The spatial response of a detector is a governing factor affecting the accuracy of image quantification, and the aim of this work was to model this impact. To simulate s...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/6/013
更新日期:2010-03-21 00:00:00
abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/4/307
更新日期:2000-04-01 00:00:00
abstract::Refraction contrast of simple objects obtained using diffraction enhanced imaging (DEI) was studied and compared to conventional radiographic contrast. Lucite cylinders and nylon wires were imaged using monochromatic synchrotron radiation at the National Synchrotron Light Source (http://nslsweb. nsls.bnl.gov/nsls/Defa...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/3/304
更新日期:2003-02-07 00:00:00
abstract::In this paper, a coupled radiative transfer equation and diffusion approximation model is extended for light propagation in turbid medium with low-scattering and non-scattering regions. The light propagation is modelled with the radiative transfer equation in sub-domains in which the assumptions of the diffusion appro...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/20/011
更新日期:2005-10-21 00:00:00
abstract::Earlier work on the dielectric properties of cryoprotectant agents is extended using a modified measuring cell and method of data reduction yielding results more efficiently over a temperature range from -75 to +25 degrees C at frequencies from 27 MHz to 3 GHz. Dimethyl sulphoxide and butanediol are investigated at lo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/10/011
更新日期:1998-10-01 00:00:00
abstract::Dosimetry of proton beams is generally evaluated in liquid water, or alternatively in solid phantoms via water equivalent ratios (WER). WER is defined as the ratio of proton range in liquid water to that in a phantom of certain material. Presently, WER is not available in the literature neither for a wide range of ene...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad0bd
更新日期:2018-07-27 00:00:00
abstract::The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9501
更新日期:2020-10-07 00:00:00
abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/18/026
更新日期:2008-09-21 00:00:00
abstract::The purpose of this work is to model electron contamination in clinical photon beams and to commission the source model using measured data for Monte Carlo treatment planning. In this work, a planar source is used to represent the contaminant electrons at a plane above the upper jaws. The source size depends on the di...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/12/013
更新日期:2004-06-21 00:00:00
abstract::In this study we investigate light penetration into skin in order to define the optimal wavelength for the treatment of port wine stains. A two-layer model (epidermis and dermis) is applied with a cylindric tube representing the ectatic blood vessel. Light propagation is calculated by the Monte Carlo method. Values fo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/10/001
更新日期:1995-10-01 00:00:00
abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab3fd3
更新日期:2019-10-23 00:00:00
abstract::In digital breast tomosynthesis (DBT), image characteristics of projection views and reconstructed volume are different and both have the advantage of detecting breast masses, e.g. reconstructed volume mitigates a tissue overlap, while projection views have less reconstruction blur artifacts. In this paper, an improve...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/22/8809
更新日期:2015-11-21 00:00:00
abstract::IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/14/003
更新日期:2009-07-21 00:00:00
abstract::A recently described, computer aided method of attenuation analysis has been applied to free-air chamber measurements of the attenuation by up to 30mm A1 of the exposure rate of a narrow beam of X-radiation excited at a thick W target in a Be window tube by constant potentials of 60, 80, 100, 120 and 140 kV. It has ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/22/2/001
更新日期:1977-03-01 00:00:00
abstract::Elasticity imaging (EI) is being developed to allow the evaluation of the mechanical properties of soft tissue, but these properties are already assessed in routine ultrasound breast examination using a method that involves the subjective interpretation of tissue motion seen in real-time B-mode image movies during pal...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/8/301
更新日期:2000-08-01 00:00:00
abstract::To investigate the detection performance of our automated detection scheme for clustered microcalcifications on mammograms, we applied our computer-aided diagnosis (CAD) system to the database of the Mammographic Image Analysis Society (MIAS) in the UK. Forty-three mammograms from this database were used in this study...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/12/021
更新日期:1997-12-01 00:00:00
abstract::The bone mineral density (BMD), ultrasound velocity (UV) and attenuation were examined in sixteen matched sets of human patellae and calcanei. For the sixteen calcanei, BMD was strongly correlated with all ultrasound parameters. Calcaneal UV appeared to be inferior to attenuation in the ability to predict BMD. For the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/10/008
更新日期:1997-10-01 00:00:00
abstract::This study aims at investigating in real-time the structural and dynamical changes occurring in an ex vivo tissue during a microwave thermal ablation (MTA) procedure. The experimental set-up was based on ex vivo liver tissue inserted in a dedicated box, in which 3 fibre-optic (FO) temperature probes were introduced to...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1a67
更新日期:2019-05-31 00:00:00
abstract::Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/19/5929
更新日期:2012-10-07 00:00:00
abstract::Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/8/011
更新日期:2009-04-21 00:00:00
abstract::Estimation of a set of parameters that describe the geometry of the cone-beam computed tomography system plays an important role in the geometrical calibration. In the calibration process, the helical phantom consisting of spherical markers arranged on a helical trajectory has been widely applied. To directly determin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/19/5667
更新日期:2014-10-07 00:00:00
abstract::Near-infrared fluorescence optical imaging has the unique opportunity of differentiating diseased lesions from normal lesions based upon environmentally indicated changes in the lifetime of a fluorescent imaging agent. In this paper, we demonstrate three-dimensional lifetime tomography using the gradient-based penalty...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/14/009
更新日期:2007-07-21 00:00:00
abstract::The Studsvik thermal-neutron facility was originally designed for neutron capture radiography (NCR) at high thermal-neutron fluence and low fast-neutron contamination. It has now been modified to permit irradiation of living cells and animals without the need for stopping and restarting the R2-0 reactor. Previous calc...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/38/8/006
更新日期:1993-08-01 00:00:00
abstract::In radiofrequency (RF) ablation or hyperthermia, internal temperature measurements and tissue property imaging are important to control their outputs and assess the treatment effect. Recently, magnetic resonance electrical impedance tomography (MREIT), as a non-invasive imaging method of internal conductivity distribu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/8/2697
更新日期:2013-04-21 00:00:00
abstract::Measurement of the dielectric properties of ocular tissues up to 110 GHz was performed by the coaxial probe method. A coaxial sensor was fabricated to allow the measurement of small amounts of biological tissues. Four-standard calibration was applied in the dielectric property measurement to obtain more accurate data ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/16/6273
更新日期:2015-08-21 00:00:00
abstract::We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aab8d2
更新日期:2018-04-20 00:00:00
abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/1/306
更新日期:2001-01-01 00:00:00