Measuring the acoustoelectric interaction constant using ultrasound current source density imaging.

Abstract:

:Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all materials; K directly affects the magnitude of the detected voltage signal in UCSDI. This paper describes a technique for measuring K in biological tissue, and reports its value for the first time in cadaver hearts. A custom chamber was designed and fabricated to control the geometry for estimating K, which was measured in different ionic salt solutions and seven cadaver rabbit hearts. We found K to be strongly dependent on concentration for the divalent salt CuSO(4), but not for the monovalent salt NaCl, consistent with their different chemical properties. In the rabbit heart, K was determined to be 0.041 ± 0.012%/MPa, similar to the measurement of K in physiological saline (0.034 ± 0.003%/MPa). This study provides a baseline estimate of K for modeling and experimental studies that involve UCSDI to map cardiac conduction and reentry currents associated with arrhythmias.

journal_name

Phys Med Biol

authors

Li Q,Olafsson R,Ingram P,Wang Z,Witte R

doi

10.1088/0031-9155/57/19/5929

subject

Has Abstract

pub_date

2012-10-07 00:00:00

pages

5929-41

issue

19

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • Computed LET distributions in the build-up region of tissue for 14 MeV neutrons.

    abstract::Experimental radiobiological investigations of fast neutron beams involve irradiation of thin cell layers. The irradiation of cells is done either in free air or with a material such as graphite, TE plastic or bone-equivalent plastic covering the cells. This paper discusses the computed dose distributions in LET at sh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/5/007

    authors: Bhatia DP,Nagarajan PS

    更新日期:1979-09-01 00:00:00

  • Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.

    abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章,信件

    doi:10.1088/1361-6560/aa9ea1

    authors: Yegin G

    更新日期:2018-02-02 00:00:00

  • A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model.

    abstract::Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm2) was developed in terms of TERMA and a total energy depo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/001

    authors: Aspradakis MM,Redpath AT

    更新日期:1997-08-01 00:00:00

  • Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry.

    abstract::The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual trace...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3585

    authors: White SA,Landry G,van Gils F,Verhaegen F,Reniers B

    更新日期:2012-06-07 00:00:00

  • Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy.

    abstract::A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4141

    authors: Gianoli C,Kurz C,Riboldi M,Bauer J,Fontana G,Baroni G,Debus J,Parodi K

    更新日期:2016-06-07 00:00:00

  • Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries.

    abstract::This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/N49

    authors: Agnew A,Agnew CE,Grattan MW,Hounsell AR,McGarry CK

    更新日期:2014-05-07 00:00:00

  • Effect of dominant features on neural network performance in the classification of mammographic lesions.

    abstract::Two different classifiers, an artificial neural network (ANN) and a hybrid system (one step rule-based method followed by an artificial neural network) have been investigated to merge computer-extracted features in the task of differentiating between malignant and benign masses. A database consisting of 65 cases (38 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/315

    authors: Huo Z,Giger ML,Metz CE

    更新日期:1999-10-01 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • A 3D reconstruction algorithm for magneto-acoustic tomography with magnetic induction based on ultrasound transducer characteristics.

    abstract::In this study we present a three-dimensional (3D) reconstruction algorithm for magneto-acoustic tomography with magnetic induction (MAT-MI) based on the characteristics of the ultrasound transducer. The algorithm is investigated to solve the blur problem of the MAT-MI acoustic source image, which is caused by the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8762

    authors: Ma R,Zhou X,Zhang S,Yin T,Liu Z

    更新日期:2016-12-21 00:00:00

  • Superpixel-based and boundary-sensitive convolutional neural network for automated liver segmentation.

    abstract::Segmentation of liver in abdominal computed tomography (CT) is an important step for radiation therapy planning of hepatocellular carcinoma. Practically, a fully automatic segmentation of liver remains challenging because of low soft tissue contrast between liver and its surrounding organs, and its highly deformable s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabd19

    authors: Qin W,Wu J,Han F,Yuan Y,Zhao W,Ibragimov B,Gu J,Xing L

    更新日期:2018-05-04 00:00:00

  • Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study.

    abstract::An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/13/310

    authors: Geraki K,Farquharson MJ,Bradley DA

    更新日期:2002-07-07 00:00:00

  • Comparison of two-compartment exchange and continuum models of dMRI in skeletal muscle.

    abstract::Clinical diffusion MRI (dMRI) is sensitive to micrometer scale spin displacements, but the image resolution is  ∼mm, so the biophysical interpretation of the signal relies on establishing appropriate subvoxel tissue models. A class of two-compartment exchange models originally proposed by Kärger have been used success...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2aa6

    authors: Naughton NM,Georgiadis JG

    更新日期:2019-08-01 00:00:00

  • A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

    abstract::Fluorescence molecular tomography (FMT) is widely used in preclinical oncology research. FMT is the only imaging technique able to provide 3D distribution of fluorescent probes within thick highly scattering media. However, its integration into clinical medicine has been hampered by its low spatial resolution caused b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf96d

    authors: Nouizi F,Kwong TC,Ruiz J,Cho J,Chan YW,Ikemura K,Erkol H,Sampathkumaran U,Gulsen G

    更新日期:2019-01-22 00:00:00

  • Comments on 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy'.

    abstract::By analyzing the radiobiological model, and the equations derived from the model, it is shown that the main results of the article 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy' by Wiklund et al (2011 Phys. Med. Biol. 56 7585-600) are valid only under the condition...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/58/18/6585

    authors: Grusell E

    更新日期:2013-09-21 00:00:00

  • Mapping initial and general recombination in scanning proton pencil beams.

    abstract::The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k s is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min-1 in ai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8579

    authors: Christensen JB,Almhagen E,Stolarczyk L,Liszka M,Hernandez GG,Bassler N,Nørrevang O,Vestergaard A

    更新日期:2020-06-05 00:00:00

  • Dose rate determination for preclinical total body irradiation.

    abstract::The accuracy of delivered radiation dose and the reproducibility of employed radiotherapy methods are key factors for preclinical radiobiology applications and research studies. In this work, ionization chamber (IC) measurements and Monte Carlo (MC) simulations were used to accurately determine the dose rate for total...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba40f

    authors: Zhong Y,Lai Y,Saha D,Story MD,Jia X,Stojadinovic S

    更新日期:2020-09-08 00:00:00

  • Reply to comment on 'origins of the changing detector response in small megavoltage photon radiation fields'.

    abstract::Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Furt...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aae0e4

    authors: Fenwick JD,Georgiou G,Rowbottom CG,Underwood TSA,Kumar S

    更新日期:2018-10-03 00:00:00

  • Temporal backward projection of optoacoustic pressure transients using fourier transform methods.

    abstract::In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/309

    authors: Köstli KP,Frenz M,Bebie H,Weber HP

    更新日期:2001-07-01 00:00:00

  • Calculation of radiation exposures from patients to whom radioactive materials have been administered.

    abstract::Spreadsheet templates which calculate cumulative exposures to other persons from patients to whom radioactive materials have been administered have been developed by the authors. Calculations can be based on any specified single-, bi- or tri-exponential whole-body clearance rate and a diurnal (or any other periodic) c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/3/003

    authors: Cormack J,Shearer J

    更新日期:1998-03-01 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • Fluence correction factors in plastic phantoms for clinical proton beams.

    abstract::In recent codes of practice for reference dosimetry in clinical proton beams using ionization chambers, it is recommended to perform the measurement in a water phantom. However, in situations where the positioning accuracy is very critical, it could be more convenient to perform the measurement in a plastic phantom. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/17/302

    authors: Palmans H,Symons JE,Denis JM,de Kock EA,Jones DT,Vynckier S

    更新日期:2002-09-07 00:00:00

  • A comparison of direct reconstruction algorithms in proton computed tomography.

    abstract::Several direct algorithms have been proposed to take into account the non-linear path of protons in the reconstruction of a proton CT (pCT) image. This paper presents a comparison between five of them, in terms of spatial resolution and relative stopping power (RSP) accuracy. Our comparison includes (1) a distance-dri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7d53

    authors: Khellaf F,Krah N,Létang JM,Collins-Fekete CA,Rit S

    更新日期:2020-06-01 00:00:00

  • Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy.

    abstract::A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/4/001

    authors: Kezerashvili M,Bednarek DR,Rudin S

    更新日期:1997-04-01 00:00:00

  • Coupled thermo-electro-mechanical models for thermal ablation of biological tissues and heat relaxation time effects.

    abstract::Thermal ablation is a widely applied electrosurgical process in medical treatment of soft biological tissues. Numerical modeling and simulations play an important role in prediction of temperature distribution and damage volume during the treatment planning stage of associated therapies. In this contribution we report...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4cc5

    authors: Singh S,Melnik R

    更新日期:2019-12-13 00:00:00

  • Experimental pencil beam kernels derivation for 3D dose calculation in flattening filter free modulated fields.

    abstract::This paper presents a method to obtain the pencil-beam kernels that characterize a megavoltage photon beam generated in a flattening filter free (FFF) linear accelerator (linac) by deconvolution from experimental measurements at different depths. The formalism is applied to perform independent dose calculations in mod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/50

    authors: Azcona JD,Barbés B,Wang L,Burguete J

    更新日期:2016-01-07 00:00:00

  • The MLC tongue-and-groove effect on IMRT dose distributions.

    abstract::We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/310

    authors: Deng J,Pawlicki T,Chen Y,Li J,Jiang SB,Ma CM

    更新日期:2001-04-01 00:00:00

  • Noninvasive reconstruction of cardiac transmembrane potentials using a kernelized extreme learning method.

    abstract::Non-invasively reconstructing the cardiac transmembrane potentials (TMPs) from body surface potentials can act as a regression problem. The support vector regression (SVR) method is often used to solve the regression problem, however the computational complexity of the SVR training algorithm is usually intensive. In t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3237

    authors: Jiang M,Zhang H,Zhu L,Cao L,Wang Y,Xia L,Gong Y

    更新日期:2015-04-21 00:00:00

  • Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction.

    abstract::Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadc88

    authors: Uzunov NM,Melendez-Alafort L,Bello M,Cicoria G,Zagni F,De Nardo L,Selva A,Mou L,Rossi-Alvarez C,Pupillo G,Di Domenico G,Uccelli L,Boschi A,Groppi F,Salvini A,Taibi A,Duatti A,Martini P,Pasquali M,Loriggiola M,Mare

    更新日期:2018-09-19 00:00:00

  • Comparison of dosimetric standards of USA and France for HDR brachytherapy.

    abstract::A bilateral comparison of national dosimetric standards for high dose rate brachytherapy has been conducted between the Laboratoire National Henri Becquerel and the University of Wisconsin Accredited Dosimetry Calibration Laboratory. A complete overview of the methods that are currently in use to establish the two nat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/50/9/003

    authors: Douysset G,Gouriou J,Delaunay F,DeWerd L,Stump K,Micka J,Laboratoire National Henri Becquerel.,University of Wisconsin Accredited Dosimetry Calibration Laboratory.

    更新日期:2005-05-07 00:00:00