Abstract:
:The accuracy of delivered radiation dose and the reproducibility of employed radiotherapy methods are key factors for preclinical radiobiology applications and research studies. In this work, ionization chamber (IC) measurements and Monte Carlo (MC) simulations were used to accurately determine the dose rate for total body irradiation (TBI), a classic radiobiologic and immunologic experimental method. Several phantom configurations, including large solid water slab, small water box and rodentomorphic mouse and rat phantoms were simulated and measured for TBI setup utilizing a preclinical irradiator XRad320. The irradiator calibration and the phantom measurements were performed using an ADCL calibrated IC N31010 following the AAPM TG-61 protocol. The MC simulations were carried out using Geant4/GATE to compute absorbed dose distributions for all phantom configurations. All simulated and measured geometries had favorable agreement. On average, the relative dose rate difference was 2.3%. However, the study indicated large dose rate deviations, if calibration conditions are assumed for a given experimental setup as commonly done for a quick determination of irradiation times utilizing lookup tables and hand calculations. In a TBI setting, the reference calibration geometry at an extended source-to-surface distance and a large reference field size is likely to overestimate true photon scatter. Consequently, the measured and hand calculated dose rates, for TBI geometries in this study, had large discrepancies: 16% for a large solid water slab, 27% for a small water box, and 31%, 36%, and 30% for mouse phantom, rat phantom, and mouse phantom in a pie cage, respectively. Small changes in TBI experimental setup could result in large dose rate variations. MC simulations and the corresponding measurements specific to a designed experimental setup are vital for accurate preclinical dosimetry and reproducibility of radiobiological findings. This study supports the well-recognized need for physics consultation for all radiobiological investigations.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Zhong Y,Lai Y,Saha D,Story MD,Jia X,Stojadinovic Sdoi
10.1088/1361-6560/aba40fsubject
Has Abstractpub_date
2020-09-08 00:00:00pages
175018issue
17eissn
0031-9155issn
1361-6560journal_volume
65pub_type
杂志文章abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa6e37
更新日期:2017-07-07 00:00:00
abstract::Compton scatter poses a significant threat to volumetric x-ray computed tomography, bringing cupping and streak artefacts thus impacting qualitative and quantitative imaging procedures. To perform appropriate scatter compensation, it is necessary to estimate the magnitude and spatial distribution of x-ray scatter. The...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/8/010
更新日期:2010-04-21 00:00:00
abstract::Improving the prevention and detection of preinvasive ductal carcinoma in situ (DCIS) is expected to lower both morbidity and mortality from breast cancer. Transgenic mouse models can be used as a 'test bed' to develop new imaging methods and to evaluate the efficacy of candidate preventive therapies. We hypothesized ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/19/014
更新日期:2008-10-07 00:00:00
abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/18/001
更新日期:2008-09-21 00:00:00
abstract::The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast. The conversion factors currently used were obtained by computer simulation of a model breast with a composition of 50% adipose and 50% glandular tissues by ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/11/308
更新日期:2000-11-01 00:00:00
abstract::As automation in radiation oncology becomes more common, it is important to determine which algorithms are equivalent for a given workflow. Often, algorithm comparisons are performed in isolation; however, clinical context can provide valuable insight into the importance of algorithm features and error magnification i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9fc8
更新日期:2020-09-28 00:00:00
abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/12/4364
更新日期:2016-06-21 00:00:00
abstract::To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab5da0
更新日期:2020-01-13 00:00:00
abstract::The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy)...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/2/569
更新日期:2016-01-21 00:00:00
abstract::We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization progra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/20/7300
更新日期:2016-10-21 00:00:00
abstract::A step and shoot sequencer was developed that can be integrated into an IMRT optimization algorithm. The method uses non-uniform fluence steps and is adopted to the constraints of an MLC. It consists of a clustering, a smoothing and a segmentation routine. The performance of the algorithm is demonstrated for eight mat...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/7/319
更新日期:2001-07-01 00:00:00
abstract::The design and performance of a dosimetric system for the irradiation of thin biological samples with therapeutic proton beams is reported. Protons with initial energies between 40 MeV and 250 MeV are degraded with polystyrene blocks of variable thickness in order to place the sample, an aqueous layer of 10 microm thi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/3/304
更新日期:2002-02-07 00:00:00
abstract::Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/7/004
更新日期:1996-07-01 00:00:00
abstract::In this paper, we have investigated the feasibility of imaging the mechanical behavior of poroelastic materials using axial strain elastography. Cylindrical samples obtained from poroelastic materials having different elastic and permeability properties were subjected to a constant compression force (a classical creep...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/11/020
更新日期:2007-06-07 00:00:00
abstract::In order to enable a detailed analysis of radio frequency (RF) absorption in the human middle and inner ear organs, a numerical model of these organs was developed at a spatial resolution of 0.1 mm, based on a real human tissue sample. The dielectric properties of the liquids (perilymph and endolymph) inside the bony ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/7/001
更新日期:2007-04-07 00:00:00
abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...
journal_title:Physics in medicine and biology
pub_type: 评论,杂志文章,信件
doi:10.1088/1361-6560/aa9ea1
更新日期:2018-02-02 00:00:00
abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...
journal_title:Physics in medicine and biology
pub_type: 临床试验,杂志文章
doi:10.1088/0031-9155/49/18/001
更新日期:2004-09-21 00:00:00
abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/5/1375
更新日期:2012-03-07 00:00:00
abstract::The dielectric properties of glycerol, propylene glycol, ethylene glycol and dimethyl sulphoxide have been measured in various aqueous concentrations generally sufficient to allow supercooling rather than freezing. The temperature range investigated is from -80 degrees C to +20 degrees C and the frequency range is 100...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/10/014
更新日期:1996-10-01 00:00:00
abstract::Images of the human retina are routinely used in clinical practice for the diagnosis and management of eye disease. Increased permeability of retinal blood vessels, which is a clinically significant feature, can be visualized with a process known as fluorescein angiography as leakage of fluorescence dye into the surro...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/1/021
更新日期:1999-01-01 00:00:00
abstract::The metabolic content of urine from NIH III nude mice (n = 22) was analysed before and after inoculation with human glioblastoma multiforme (GBM) cancer cells. An age- and gender-matched control population (n = 14) was also studied to identify non-tumour-related changes. Urine samples were collected daily for 6 weeks,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/3/002
更新日期:2011-02-07 00:00:00
abstract::A non-contact approach for diffuse optical tomography (DOT) has been developed for on-demand image updates using surgical navigation technology. A stereoscopic optical tracker provides real-time localization of reflective spheres mounted to a laser diode and near-infrared camera. Standard camera calibration is combine...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1f33
更新日期:2019-07-05 00:00:00
abstract::Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gam...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/4/005
更新日期:1979-07-01 00:00:00
abstract::This work discusses the substitution of a gelatine physical gel matrix with a matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127) in five 3D radiotherapy polymer gel dosimeters: MAGAT, PAGAT, NIPAM, VIPARnd (VIP) and VIPARCT (VIC). The current research outcomes s...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad9d5
更新日期:2018-09-06 00:00:00
abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/13/022
更新日期:2007-07-07 00:00:00
abstract::Histotripsy is a therapeutic ultrasound modality under development to liquefy tissue mechanically via bubble clouds. Image guidance of histotripsy requires both quantification of the bubble cloud activity and accurate delineation of the treatment zone. In this study, magnetic resonance (MR) and diagnostic ultrasound i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab143f
更新日期:2019-05-02 00:00:00
abstract::The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5 cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaba8f
更新日期:2018-05-01 00:00:00
abstract::The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/2/554
更新日期:2016-01-21 00:00:00
abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac09a
更新日期:2018-05-17 00:00:00
abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/22/008
更新日期:2003-11-21 00:00:00