Dosimetry system for the irradiation of thin biological samples with therapeutic proton beams.

Abstract:

:The design and performance of a dosimetric system for the irradiation of thin biological samples with therapeutic proton beams is reported. Protons with initial energies between 40 MeV and 250 MeV are degraded with polystyrene blocks of variable thickness in order to place the sample, an aqueous layer of 10 microm thickness, at various locations on the proton depth-dose curve. The dosimetric system comprises a secondary emission monitor, a Faraday cup and thin ionization chambers, which are located upstream of the sample, and a calcium fluoride scintillator located downstream of the sample for monitoring the position of the sample relative to the Bragg peak. Transverse dose profiles were measured with radiochromic films. System performance was studied and optimized by simulating primary radiation transport through detectors, degrader and sample using the Monte Carlo simulation tool GEANT 3.21. Calculated detector responses and beam profiles agreed well with the measured data. Monte Carlo simulation was also used to evaluate mean values and spectra of linear energy transfer in the sample as a function of initial proton energy and degrader thickness. Long-term experience has shown that the system performance was unchanged after accumulated doses of 10(5) Gy.

journal_name

Phys Med Biol

authors

Bashkirov V,Schulte RW

doi

10.1088/0031-9155/47/3/304

subject

Has Abstract

pub_date

2002-02-07 00:00:00

pages

409-20

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

47

pub_type

杂志文章
  • Power deposition in the head and neck of an anatomically based human body model for plane wave exposures.

    abstract::At certain frequencies, when the human head becomes a resonant structure, the power absorbed by the head and neck, when the body is exposed to a vertically polarized plane wave propagating from front to back, becomes significantly larger than would ordinarily be expected from its shadow cross section. This has possibl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/026

    authors: Tinniswood AD,Furse CM,Gandhi OP

    更新日期:1998-08-01 00:00:00

  • A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations.

    abstract::A photon diffusion model has been developed to calculate the steady-state spatially resolved fluorescence from pencil beam excitation in layered tissue. The model allows the calculation of both the excitation reflectance and the fluorescence escape for an arbitrary continuous depth distribution of tissue optical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/307

    authors: Hyde DE,Farrell TJ,Patterson MS,Wilson BC

    更新日期:2001-02-01 00:00:00

  • Optimization of attenuation correction for positron emission tomography studies of thorax and pelvis using count-based transmission scans.

    abstract::The quality of thorax and pelvis transmission scans and therefore of attenuation correction in PET depends on patient thickness and transmission rod source strength. The purpose of the present study was to assess the feasibility of using count-based transmission scans, thereby guaranteeing more consistent image qualit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/n01

    authors: Boellaard R,van Lingen A,van Balen SC,Lammertsma AA

    更新日期:2004-02-21 00:00:00

  • The assessment of the non-equilibrium effect in the 'Patlak analysis' of Fdopa PET studies.

    abstract::'Patlak analysis' is a common approach used in Fdopa PET studies to calculate the uptake constant (Ki) of the tracer. It is assumed in the Patlak analysis that the reversible compartment of tissue radioactivity used is in effective equilibrium with the tracer in plasma. Therefore, using the data prior to equilibrium i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/7/007

    authors: Yu DC,Huang SC,Barrio JR,Phelps ME

    更新日期:1995-07-01 00:00:00

  • An approach to the surveying of radiation environments for radiation protection purposes.

    abstract::Many of the inadequacies of the system presently used for surveying environments containing penetrating radiation stem from the impossibility of defining a radiation parameter which is additive, measurable and closely related to peak dose equivalent in the body. Many of the present conceptual difficulties would be eli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/6/012

    authors: Harvey JR

    更新日期:1975-11-01 00:00:00

  • A point kernel algorithm for microbeam radiation therapy.

    abstract::Microbeam radiation therapy (MRT) is a treatment approach in radiation therapy where the treatment field is spatially fractionated into arrays of a few tens of micrometre wide planar beams of unusually high peak doses separated by low dose regions of several hundred micrometre width. In preclinical studies, this treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8d63

    authors: Debus C,Oelfke U,Bartzsch S

    更新日期:2017-10-19 00:00:00

  • Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

    abstract::The purpose of this study is to develop an adaptive prior knowledge guided image estimation technique to reduce the scan angle needed in the limited-angle intrafraction verification (LIVE) system for 4D-CBCT reconstruction. The LIVE system has been previously developed to reconstruct 4D volumetric images on-the-fly du...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6913

    authors: Zhang Y,Yin FF,Zhang Y,Ren L

    更新日期:2017-05-07 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • Positron autoradiography for intravascular imaging: feasibility evaluation.

    abstract::Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/4/014

    authors: Shikhaliev PM,Xu T,Ducote JL,Easwaramoorthy B,Mukherjee J,Molloi S

    更新日期:2006-02-21 00:00:00

  • Blood irradiation with accelerator produced electron beams.

    abstract::Blood and blood products are irradiated with gamma rays to reduce the risk of graft versus host disease (GVHD). A simple technique using electron beams produced by a medical linear accelerator has been studied to evaluate irradiation of blood and blood products. Variations in applied doses for a single field 20 MeV el...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/401

    authors: Butson MJ,Cheung T,Yu PK,Stokes MJ

    更新日期:2000-11-01 00:00:00

  • Potential applications of the quantitative susceptibility mapping (QSM) in MR-guided radiation therapy.

    abstract::Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2623

    authors: Nosrati R,Paudel M,Ravi A,Pejovic-Milic A,Morton G,Stanisz GJ

    更新日期:2019-07-16 00:00:00

  • A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging.

    abstract::Quantification in cardiac mouse positron emission tomography (PET) imaging is limited by the imaging spatial resolution. Spillover of left ventricle (LV) myocardial activity into adjacent organs results in partial volume (PV) losses leading to underestimation of myocardial activity. A PV correction method was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4309

    authors: Dumouchel T,Thorn S,Kordos M,DaSilva J,Beanlands RS,deKemp RA

    更新日期:2012-07-07 00:00:00

  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00

  • Effects of body habitus on internal radiation dose calculations using the 5-year-old anthropomorphic male models.

    abstract::Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa75b4

    authors: Xie T,Kuster N,Zaidi H

    更新日期:2017-07-13 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Quantitation in SPECT using an effective model of the scattering.

    abstract::A new method for correcting simultaneously the attenuation, scatter and resolution effects in SPECT has been developed for the case of a homogeneous medium. It is based on an effective model of the scatter process. This model depends on only four parameters which are determined experimentally and remain independent of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/4/005

    authors: Walrand SH,van Elmbt LR,Pauwels S

    更新日期:1994-04-01 00:00:00

  • Quantitative analysis of a micro array anode structured target for hard x-ray grating interferometry.

    abstract::Talbot-Lau interferometry (TLI) provides additional contrast modes for x-ray imaging that are complementary to conventional absorption radiography. TLI is particularly interesting because it is one of the few practical methods for realizing phase contrast with x-rays that is compatible with large-spot high power x-ray...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab6578

    authors: Zan G,Vine DJ,Yun W,Lewis SJY,Wang Q,Wang G

    更新日期:2020-02-04 00:00:00

  • Multiobjective evolutionary optimization of the number of beams, their orientations and weights for intensity-modulated radiation therapy.

    abstract::We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clini...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/007

    authors: Schreibmann E,Lahanas M,Xing L,Baltas D

    更新日期:2004-03-07 00:00:00

  • An edge-on charge-transfer design for energy-resolved x-ray detection.

    abstract::As an x-ray beam goes through the human body, it will collect important information via interaction with tissues. Since this interaction is energy-sensitive, the state-of-the-art spectral CT technologies provide higher quality images of biological tissues with x-ray energy information (or spectral information). With e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4183

    authors: Shi Z,Yang H,Cong W,Wang G

    更新日期:2016-06-07 00:00:00

  • Kinetic filtering of [(18)F]Fluorothymidine in positron emission tomography studies.

    abstract::[(18)F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/010

    authors: Gray KR,Contractor KB,Kenny LM,Al-Nahhas A,Shousha S,Stebbing J,Wasan HS,Coombes RC,Aboagye EO,Turkheimer FE,Rosso L

    更新日期:2010-02-07 00:00:00

  • Exploration of tradeoffs in intensity-modulated radiotherapy.

    abstract::The purpose of this study is to calculate Pareto surfaces in multi-criteria radiation treatment planning and to analyse the dependency of the Pareto surfaces on the objective functions used for the volumes of interest. We develop a linear approach that allows us to calculate truly Pareto optimal treatment plans, and w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/24/007

    authors: Craft D,Halabi T,Bortfeld T

    更新日期:2005-12-21 00:00:00

  • Coupled thermo-electro-mechanical models for thermal ablation of biological tissues and heat relaxation time effects.

    abstract::Thermal ablation is a widely applied electrosurgical process in medical treatment of soft biological tissues. Numerical modeling and simulations play an important role in prediction of temperature distribution and damage volume during the treatment planning stage of associated therapies. In this contribution we report...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4cc5

    authors: Singh S,Melnik R

    更新日期:2019-12-13 00:00:00

  • Classification of movement intention by spatially filtered electromagnetic inverse solutions.

    abstract::We couple standardized low-resolution electromagnetic tomography, an inverse solution for electroencephalography (EEG) and the common spatial pattern, which is here conceived as a data-driven beamformer, to classify the benchmark BCI (brain-computer interface) competition 2003, data set IV. The data set is from an exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/8/002

    authors: Congedo M,Lotte F,Lécuyer A

    更新日期:2006-04-21 00:00:00

  • A novel high-throughput irradiator for in vitro radiation sensitivity bioassays.

    abstract::This paper describes the development and characterization of a fully automated in vitro cell irradiator using an electronic brachytherapy source to perform radiation sensitivity bioassays. This novel irradiator allows complex variable dose and dose rate schemes to be delivered to multiple wells of 96-well culture plat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/6/1459

    authors: Fowler TL,Fulkerson RK,Micka JA,Kimple RJ,Bednarz BP

    更新日期:2014-03-21 00:00:00

  • A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

    abstract::Dynamic PET image reconstruction is a challenging issue due to the low SNR and the large quantity of spatio-temporal data. We propose a robust state-space image reconstruction (SSIR) framework for activity reconstruction in dynamic PET. Unlike statistically-based frame-by-frame methods, tracer kinetic modeling is inco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/010

    authors: Tong S,Alessio AM,Kinahan PE,Liu H,Shi P

    更新日期:2011-04-21 00:00:00

  • Photon penetration and scatter in micro-pinhole imaging: a Monte Carlo investigation.

    abstract::Pinhole SPECT is rapidly gaining popularity for imaging laboratory animals using gamma-emitting molecules. Penetration and scattering of gamma radiation in the pinhole edge material can account for a significant fraction of the total number of photons detected, particularly if the pinholes have small diameters. This s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/8/001

    authors: van der Have F,Beekman FJ

    更新日期:2004-04-21 00:00:00

  • A search for improved technique factors in paediatric fluoroscopy.

    abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/018

    authors: Tapiovaara MJ,Sandborg M,Dance DR

    更新日期:1999-02-01 00:00:00

  • Film dosimetry using a smart device camera: a feasibility study for point dose measurements.

    abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8b36

    authors: Aland T,Jhala E,Kairn T,Trapp J

    更新日期:2017-10-03 00:00:00

  • Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition.

    abstract::Two new detectors (0.015 cm3 ion chamber from PTW, 0.6 mm diameter diode from Scanditronix AB) designed specifically for use in small stereotactic fields were compared against similar, more routine, detectors (0.125 cm3 ion chamber, parallel plate chamber, shielded and unshielded diodes and film). Percentage depth dos...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/9/303

    authors: McKerracher C,Thwaites DI

    更新日期:1999-09-01 00:00:00

  • Optical attenuation characteristics of breast tissues at visible and near-infrared wavelengths.

    abstract::Optical experiments are described for measuring the attenuation characteristics of breast tissues at visible and near-infrared wavelengths. Total attenuation coefficients post mortem were measured directly in thin tissue sections. They are usually within the range from 10 to 30 mm-1, are rather higher in fat than in f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/5/002

    authors: Key H,Davies ER,Jackson PC,Wells PN

    更新日期:1991-05-01 00:00:00