Tumour xenograft detection through quantitative analysis of the metabolic profile of urine in mice.

Abstract:

:The metabolic content of urine from NIH III nude mice (n = 22) was analysed before and after inoculation with human glioblastoma multiforme (GBM) cancer cells. An age- and gender-matched control population (n = 14) was also studied to identify non-tumour-related changes. Urine samples were collected daily for 6 weeks, beginning 1 week before cell injection. Metabolite concentrations were obtained via targeted profiling with Chenomx Suite 5.1, based on nuclear magnetic resonance (NMR) spectra acquired on an Oxford 800 MHz cold probe NMR spectrometer. The Wilcoxon rank sum test was used to evaluate the significance of the change in metabolite concentration between the two time points. Both the metabolite concentrations and the ratios of pairs of metabolites were studied. The complicated inter-relationships between metabolites were assessed through partial least-squares discriminant analysis (PLS-DA). Receiver operating characteristic (ROC) curves were generated for all variables and the area under the curve (AUC) calculated. The data indicate that the number of statistically significant changes in metabolite concentrations was more pronounced in the tumour-bearing population than in the control animals. This was also true of the ratios of pairs of metabolites. ROC analysis suggests that the ratios were better able to differentiate between the pre- and post-injection samples compared to the metabolite concentrations. PLS-DA models produced good separation between the populations and had the best AUC results (all models exceeded 0.937). These results demonstrate that metabolomics may be used as a screening tool for GBM cells grown in xenograft models in mice.

journal_name

Phys Med Biol

authors

Moroz J,Turner J,Slupsky C,Fallone G,Syme A

doi

10.1088/0031-9155/56/3/002

subject

Has Abstract

pub_date

2011-02-07 00:00:00

pages

535-56

issue

3

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)66009-5

journal_volume

56

pub_type

杂志文章
  • A method for photon beam Monte Carlo multileaf collimator particle transport.

    abstract::Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/17/312

    authors: Siebers JV,Keall PJ,Kim JO,Mohan R

    更新日期:2002-09-07 00:00:00

  • Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications.

    abstract::Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, makin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1c37

    authors: Du J,Bai X,Cherry SR

    更新日期:2019-08-07 00:00:00

  • Effect of microscopic modeling of skin in electrical and thermal analysis of transcranial direct current stimulation.

    abstract::Transcranial direct current stimulation (tDCS) is a neuromodulation scheme where a small current is delivered to the brain via two electrodes attached to the scalp. The electrode design is an important topic, not only as regards efficacy, but also from a safety perspective, as tDCS may be related to skin lesions that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8825

    authors: Gomez-Tames J,Sugiyama Y,Laakso I,Tanaka S,Koyama S,Sadato N,Hirata A

    更新日期:2016-12-21 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00

  • Denoising of multi b-value diffusion-weighted MR images using deep image prior.

    abstract::The clinical value of multiple b-value diffusion-weighted (DW) magnetic resonance imaging (MRI) has been shown in many studies. However, DW-MRI often suffers from low signal-to-noise ratio, especially at high b-values. To address this limitation, we present an image denoising method based on the concept of deep image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8105

    authors: Lin YC,Huang HM

    更新日期:2020-05-11 00:00:00

  • Determination of some parameters for pion radiobiology studies.

    abstract::An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this dic 'target' was measured using a s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/3/007

    authors: Nordell B,Baarli J,Sullivan AH,Zielczynski M

    更新日期:1977-05-01 00:00:00

  • Spinal pedicle screw planning using deformable atlas registration.

    abstract::Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device sele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5f42

    authors: Goerres J,Uneri A,De Silva T,Ketcha M,Reaungamornrat S,Jacobson M,Vogt S,Kleinszig G,Osgood G,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-07 00:00:00

  • Simulations of a micro-PET system based on liquid xenon.

    abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/6/1685

    authors: Miceli A,Glister J,Andreyev A,Bryman D,Kurchaninov L,Lu P,Muennich A,Retiere F,Sossi V

    更新日期:2012-03-21 00:00:00

  • Iterative deblurring algorithm for a multiplane tomographic scanner.

    abstract::An iterative algorithm has been developed to reduce blur artefacts in images obtained from the Pho/Con multiplane tomographic scanner. In this technique estimates of the activity distribution are convolved with the detector response function and compared with the original blurred image planes. Successive estimates of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/7/004

    authors: Zenari A,Hooper RH,Osborne N,Scrimger JW

    更新日期:1985-07-01 00:00:00

  • Measurement of total body nitrogen and oxygen by irradiation with cyclotron neutrons and 'delayed' gamma ray counting.

    abstract::Measurement of total body nitrogen is assuming increasing importance in the nutritional evaluation of seriously ill patients. Nitrogen has been previously measured either by counting (i) the annihilation radiation from 13N immediately after neutron irradiation with 14 MeV neutrons or (ii) the 'prompt' gamma rays from ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/4/008

    authors: Spinks TJ,Goode AW,Ranicar AS,Steere E

    更新日期:1984-04-01 00:00:00

  • Dielectric properties of ocular tissues in the supercooled and frozen states.

    abstract::Values of the relative permittivity and conductivity of the rabbit retina and lens have been measured between 10 MHz and 10 GHz over the temperature range 20 to -20 degrees C. As the temperature was lowered from 20 degrees C the dielectric parameters changed smoothly until -9 degrees C where freezing occurred. At this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/9/009

    authors: Gabriel C,Grant EH

    更新日期:1985-09-01 00:00:00

  • Laser shaping of corneal transplants in vitro: area ablation with small overlapping laser spots produced by a pulsed scanning laser beam using an optimizing ablation algorithm.

    abstract::Area laser lathing and trephination of donor corneas is used to produce different types of grafts for human transplantation. 193 nm (ArF excimer) laser radiation is used, since this is known to give a non-thermal laser-tissue interaction with a minimal zone of tissue damage. To guarantee the highest degree of flexibil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/5/005

    authors: Homolka P,Biowski R,Kaminski S,Barisani T,Husinsky W,Bergmann H,Grabner G

    更新日期:1999-05-01 00:00:00

  • Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcdb

    authors: Lee H,Yeom YS,Nguyen TT,Choi C,Han H,Shin B,Zhang X,Kim CH,Chung BS,Zankl M

    更新日期:2019-02-05 00:00:00

  • Coupled radiative transfer equation and diffusion approximation model for photon migration in turbid medium with low-scattering and non-scattering regions.

    abstract::In this paper, a coupled radiative transfer equation and diffusion approximation model is extended for light propagation in turbid medium with low-scattering and non-scattering regions. The light propagation is modelled with the radiative transfer equation in sub-domains in which the assumptions of the diffusion appro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/011

    authors: Tarvainen T,Vauhkonen M,Kolehmainen V,Arridge SR,Kaipio JP

    更新日期:2005-10-21 00:00:00

  • A model for the accurate computation of the lateral scattering of protons in water.

    abstract::A pencil beam model for the calculation of the lateral scattering in water of protons for any therapeutic energy and depth is presented. It is based on the full Molière theory, taking into account the energy loss and the effects of mixtures and compounds. Concerning the electromagnetic part, the model has no free para...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/N102

    authors: Bellinzona EV,Ciocca M,Embriaco A,Ferrari A,Fontana A,Mairani A,Parodi K,Rotondi A,Sala P,Tessonnier T

    更新日期:2016-02-21 00:00:00

  • Reply to Comment: 'A novel method for fast and robust estimation of fluorescence decay dynamics using constrained least-square deconvolution with Laguerre expansion'.

    abstract::In this response we underscore that the instrumentation described in the original publication (Liu et al 2012 Phys. Med. Biol. 57 843-65) was based on pulse-sampling technique, while the comment by Zhang et al is based on the assumption that a time-correlated single photon counting (TCSPC) instrumentation was used. Th...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aa5231

    authors: Ma D,Liu J,Qi J,Marcu L

    更新日期:2017-02-21 00:00:00

  • Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology.

    abstract::We present a new method for automated characterization of atherosclerotic plaque composition in ex vivo MRI. It uses MRI intensities as well as four other types of features: smoothed, gradient magnitude and Laplacian images at several scales, and the distances to the lumen and outer vessel wall. The ground truth for f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/1/241

    authors: van Engelen A,Niessen WJ,Klein S,Groen HC,Verhagen HJ,Wentzel JJ,van der Lugt A,de Bruijne M

    更新日期:2012-01-07 00:00:00

  • Automatic T1 bladder tumor detection by using wavelet analysis in cystoscopy images.

    abstract::Correct classification of cystoscopy images depends on the interpreter's experience. Bladder cancer is a common lesion that can only be confirmed by biopsying the tissue, therefore, the automatic identification of tumors plays a significant role in early stage diagnosis and its accuracy. To our best knowledge, the use...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa3af

    authors: Freitas NR,Vieira PM,Lima E,Lima CS

    更新日期:2018-02-02 00:00:00

  • Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

    abstract::Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registratio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa62c5

    authors: Uneri A,De Silva T,Goerres J,Jacobson MW,Ketcha MD,Reaungamornrat S,Kleinszig G,Vogt S,Khanna AJ,Osgood GM,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-21 00:00:00

  • The distribution of trace elements Ca, Fe, Cu and Zn and the determination of copper oxidation state in breast tumour tissue using muSRXRF and muXANES.

    abstract::A micro beam synchrotron x-ray fluorescence (muSRXRF) technique has been used to determine the localization of metals in primary invasive ductal carcinoma of breast. Nine samples were examined, all of which were formalin fixed tissues arranged as micro arrays of 1.0 mm diameter and 10 microm thickness. Cu was the part...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/11/018

    authors: Farquharson MJ,Al-Ebraheem A,Falkenberg G,Leek R,Harris AL,Bradley DA

    更新日期:2008-06-07 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations.

    abstract::A photon diffusion model has been developed to calculate the steady-state spatially resolved fluorescence from pencil beam excitation in layered tissue. The model allows the calculation of both the excitation reflectance and the fluorescence escape for an arbitrary continuous depth distribution of tissue optical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/307

    authors: Hyde DE,Farrell TJ,Patterson MS,Wilson BC

    更新日期:2001-02-01 00:00:00

  • An analysis of breast motion using high-frequency, dense surface points captured by an optical sensor during radiotherapy treatment delivery.

    abstract::Patient motion is an important factor affecting the quality of external beam radiotherapy in breast patients. We analyse the motion of a dense set of surface points on breast patients throughout their treatment schedule to assess the magnitude and stability of motion, in particular, with respect to breast volume. We u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/21/005

    authors: Price GJ,Sharrock PJ,Marchant TE,Parkhurst JM,Burton D,Jain P,Price P,Moore CJ

    更新日期:2009-11-07 00:00:00

  • Refraction-angle resolution of diffraction enhanced imaging.

    abstract::As a new method, x-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low-Z samples in medical and biological fields. Conventional performance parameters, such as spatial resolution and low-contrast resolution, are not enough to describe the characteristics of a DEI system. This...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/002

    authors: Huang ZF,Kang KJ,Li Z

    更新日期:2006-06-21 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • W values and other transport data on low energy electrons in tissue equivalent gas.

    abstract::The degradation of low energy electrons in a methane based, tissue equivalent gas was studied experimentally by ionization chamber experiments and theoretically by Monte Carlo electron transport simulation in the energy range between 25 eV and 5 keV. From measured ionization yields and calculated ionization and energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/5/008

    authors: Waibel E,Grosswendt B

    更新日期:1992-05-01 00:00:00

  • An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams.

    abstract::The energy dependence of alanine/EPR dosimetry, in terms of absorbed dose-to-water for clinical 6, 10, 25 MV x-rays and 60Co gamma-rays was investigated by measurements and Monte Carlo (MC) calculations. The dose rates were traceable to the NRC primary standard for absorbed dose, a sealed water calorimetry. The electr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/2/006

    authors: Zeng GG,McEwen MR,Rogers DW,Klassen NV

    更新日期:2004-01-21 00:00:00

  • Comparison of recent codes of practice for high-energy photon dosimetry.

    abstract::Absorbed dose values were determined under the reference conditions in a phantom irradiated by high-energy photon beams with quality varying between 60Co gamma rays and 25 MV X-rays, using four commonly employed types of ionisation chamber. The ionisation chamber readings were converted to absorbed dose values applyin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/006

    authors: Mijnheer BJ,Wittkämper FW

    更新日期:1986-04-01 00:00:00

  • Optimization of a depth of interaction encoding PET block detector for a PET/MRI insert.

    abstract::Preclinical positron emission tomography, combined with magnetic resonance imaging (PET/MRI), is increasingly used as a tool to simultaneously characterize functional processes in vivo. Many emerging preclinical applications, however, are limited by PET detection sensitivity, especially when generating short imaging f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef59

    authors: Selfridge AR,Cherry SR,Judenhofer MS

    更新日期:2018-12-06 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00